TI1 ADS130E08 Analog front-end for power monitoring, control, and protection Datasheet

ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
Analog Front-End for Power Monitoring, Control, and Protection
Check for Samples: ADS131E04, ADS131E06 , ADS131E08
FEATURES
1
•
•
23
•
•
•
•
•
•
•
•
Eight Differential Current and Voltage Inputs
Outstanding Performance:
– Exceeds Class 0.1 Performance
– Dynamic Range at 1 kSPS: 118 dB
– Crosstalk: –110 dB
– THD: –90 dB at 50 Hz and 60 Hz
Supply Range:
– Analog:
– +3 V to +5 V (Unipolar)
– ±2.5 V (Bipolar, allows dc coupling)
– Digital: +1.8 V to +3.6 V
Low Power: 2 mW per Channel
Data Rates: 1, 2, 4, 8, 16, 32, and 64 kSPS
Programmable Gains (1, 2, 4, 8, and 12)
Fault Detection and Device Testing Capability
SPI™ Data Interface and Four GPIOs
Package: TQFP-64 (PAG)
Operating Temperature Range:
–40°C to +105°C
APPLICATIONS
•
The ADS131E0x incorporate features commonly
required in industrial power monitoring, control, and
protection applications. The ADS131E0x inputs can
be independently and directly interfaced with a
resistor-divider network or a transformer to measure
voltage. The inputs can also be interfaced to a
current transformer or Rogowski coil to measure
current. With high integration levels and exceptional
performance, the ADS131E0x family enables the
creation of scalable industrial power systems at
significantly reduced size, power, and low overall
cost.
The ADS131E0x have a flexible input multiplexer per
channel that can be independently connected to the
internally-generated signals for test, temperature, and
fault detection. Fault detection can be implemented
internal to the device, using the integrated
comparators with digital-to-analog converter (DAC)controlled trigger levels. The ADS131E0x can operate
at data rates as high as 64 kSPS.
These complete analog front-end (AFE) solutions are
packaged in a TQFP-64 package and are specified
over the industrial temperature range of –40°C to
+105°C.
Current
Sensing
Channel 1
PGA
û
ADC
Voltage
Sensing
Channel 2
PGA
û
ADC
Current
Sensing
Channel 3
PGA
û
ADC
Channel 4
PGA
û
ADC
Line A
Industrial Power Applications:
– Energy Metering
– Monitoring, Control, and Protection
Line B
DESCRIPTION
The ADS131E0x are a family of multichannel,
simultaneous sampling, 24- and 16-bit, delta-sigma
(ΔΣ), analog-to-digital converters (ADCs) with a builtin programmable gain amplifier (PGA), internal
reference, and an onboard oscillator.
Voltage
Sensing
EMI
Filters
and
Input
MUX
Device
Voltage
Reference
Oscillator
Control
and
SPI Interface
Channel 5
PGA
û
ADC
Voltage
Sensing
Channel 6
PGA
û
ADC
Fault
Detection
Current
Sensing
Channel 7
PGA
û
ADC
Test
Channel 8
PGA
û
ADC
Current
Sensing
Line C
Line N
Voltage
Sensing
Op
Amp
1
2
3
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
SPI is a trademark of Motorola.
All other trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2012, Texas Instruments Incorporated
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
FAMILY AND ORDERING INFORMATION (1)
(1)
MAXIMUM SAMPLE
RATE (kSPS)
OPERATING
TEMPERATURE
RANGE
PRODUCT
PACKAGE OPTION
NUMBER OF
CHANNELS
ADS130E08
TQFP-64
8
Class 1.0
8
–40°C to +105°C
ADS131E04
TQFP-64
4
Class 0.1
64
–40°C to +105°C
ADS131E06
TQFP-64
6
Class 0.1
64
–40°C to +105°C
ADS131E08
TQFP-64
8
Class 0.1
64
–40°C to +105°C
ACCURACY
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or visit the
device product folder at www.ti.com.
ABSOLUTE MAXIMUM RATINGS (1)
Over operating free-air temperature range, unless otherwise noted.
VALUE
UNIT
AVDD to AVSS
–0.3 to +5.5
V
DVDD to DGND
–0.3 to +3.9
V
AGND to DGND
–0.3 to +0.3
V
Analog input to AVSS
AVSS – 0.3 to AVDD + 0.3
V
Digital input to DVDD
DVSS – 0.3 to DVDD + 0.3
V
±10
mA
Momentary
±100
mA
Continuous
±10
mA
Operating, industrial-grade devices only
–40 to +85
°C
Storage
Input current to any pin except supply pins (2)
Input current
Temperature
Electrostatic discharge
(ESD) ratings
(1)
(2)
2
–60 to +150
°C
Maximum junction, TJ
+150
°C
Human body model (HBM)
JEDEC standard 22, test method A114-C.01, all pins
±1000
V
Charged device model (CDM)
JEDEC standard 22, test method C101, all pins
±500
V
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
Input terminals are diode-clamped to the power-supply rails. Input signals that can swing beyond the supply rails must be current limited
to 10 mA or less.
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
ELECTRICAL CHARACTERISTICS
Minimum and maximum specifications apply from –40°C to +105°C. Typical specifications are at +25°C. All specifications are
at DVDD = 1.8 V, AVDD = 3 V, AVSS = 0 V, VREF = 2.4 V, external fCLK = 2.048 MHz, data rate = 8 kSPS, and gain = 1,
unless otherwise noted.
ADS131E0x
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
ANALOG INPUTS
Full-scale differential input voltage
(AINP – AINN)
±VREF / gain
See the Input Common-Mode Range
subsection of the PGA Settings and
Input Range section
Input common-mode range
Ci
Input capacitance
IIB
Input bias current
V
PGA output in normal range
DC input impedance
20
pF
5
nA
200
MΩ
PGA PERFORMANCE
BW
Gain settings
1, 2, 4, 8, 12
Bandwidth
See Table 3
ADC PERFORMANCE
Resolution
DR
Data rate
Data rates up to 16 kSPS
24
32- and 64-kSPS data rate
16
fCLK = 2.048 MHz
Bits
Bits
1
64
kSPS
CHANNEL PERFORMANCE (DC Performance)
INL
Integral nonlinearity
Full-scale, best fit
G=1
Dynamic range
EO
EG
Gain settings other than 1
10
ppm
105
dB
See Noise Measurements section
Offset error
350
μV
Offset error drift
0.65
μV/°C
Gain error
Excluding voltage reference error
Gain drift
Excluding voltage reference drift
0.1
Gain match between channels
%
3
ppm/°C
0.2
% of FS
CHANNEL PERFORMANCE (AC Performance)
CMRR
Common-mode rejection ratio
fCM = 50 Hz and 60 Hz (1)
–110
dB
PSRR
Power-supply rejection ratio
fPS = 50 Hz and 60 Hz
–80
dB
Crosstalk
fIN = 50 Hz and 60 Hz
–110
dB
Accuracy
1:3000 dynamic range with a 1-second
measurement (VRMS / IRMS)
0.1
%
SNR
Signal-to-noise ratio
fIN = 50 Hz and 60 Hz, gain = 1
107
dB
THD
Total harmonic distortion
10 Hz, –0.5 dBFs
–93
dB
±30
mV
AVDD = 3 V, VREF = (VREFP – VREFN)
2.5
V
AVDD = 5 V, VREF = (VREFP – VREFN)
4
V
AVSS
V
FAULT DETECT AND ALARM
Comparator threshold accuracy
EXTERNAL REFERENCE
Reference input voltage
VREFN
Negative input
VREFP
Positive input
AVSS + 2.5
Input impedance
(1)
6
V
kΩ
CMRR is measured with a common-mode signal of (AVSS + 0.3 V) to (AVDD – 0.3 V). The values indicated are the minimum of the
eight channels.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
3
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
Minimum and maximum specifications apply from –40°C to +105°C. Typical specifications are at +25°C. All specifications are
at DVDD = 1.8 V, AVDD = 3 V, AVSS = 0 V, VREF = 2.4 V, external fCLK = 2.048 MHz, data rate = 8 kSPS, and gain = 1,
unless otherwise noted.
ADS131E0x
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
OPERATIONAL AMPLIFIER
Integrated noise
0.1 Hz to 250 Hz
Noise density
2 kHz
GBP
Gain bandwidth product
50 kΩ || 10-pF load
100
kHz
SR
Slew rate
50 kΩ || 10-pF load
0.25
V/µs
Load current
9
µVRMS
120
nV/√Hz
50
THD
Total harmonic distortion
CMIR
Common-mode input range
fIN = 100 Hz
µA
70
AVSS + 0.7
Quiescent power consumption
dB
AVDD – 0.3
V
20
µA
CONFIG2.VREF_4V = 0
2.4
V
CONFIG2.VREF_4V = 1
4
V
±0.2
%
INTERNAL REFERENCE
VO
Output voltage
VREF accuracy
0°C ≤ TA ≤ +70°C
30
ppm/°C
–40°C ≤ TA ≤ +105°C
40
ppm/°C
150
ms
Analog
2
%
Digital
2
%
150
ms
Temperature drift
Start-up time
Settled to 0.2%
SYSTEM MONITORS
Supply reading error
From power-up to DRDY low
Device wake up
STANDBY mode
Temperature sensor Voltage
reading
Coefficient
TA = +25°C
31.25
µs
145
mV
490
μV/°C
SELF-TEST SIGNAL
Signal frequency
fCLK / 221
See Register Map section for settings
Signal voltage
See Register Map section for settings
Accuracy
Hz
fCLK / 220
Hz
±1
mV
±2
mV
±2
%
CLOCK
Nominal frequency
Internal oscillator clock frequency
2.048
TA = +25°C
MHz
±0.5
–40°C ≤ TA ≤ +105°C
2.5
Internal oscillator start-up time
External clock input frequency
%
μs
20
Internal oscillator power consumption
%
μW
120
CLKSEL pin = 0, AVDD = 3 V
1.7
2.048
2.25
MHz
CLKSEL pin = 0, AVDD = 5 V
0.7
2.048
2.25
MHz
DIGITAL INPUT AND OUTPUT (DVDD = 1.8 V to 3.6 V)
VIH
Logic level,
input voltage
High
0.8 DVDD
DVDD + 0.1
V
Low
–0.1
0.2 DVDD
V
IOH = –500 µA
VOL
Logic level,
output voltage
High
Low
IOL = +500 µA
IIN
Input current
VIL
VOH
0 V < VDigitalInput < DVDD
0.9 DVDD
V
–10
0.1 DVDD
V
+10
μA
POWER-SUPPLY REQUIREMENTS
AVDD
Analog supply
DVDD
Digital supply
AVDD – AVSS
AVDD – DVDD
4
2.7
3
5.25
V
1.8
1.8
3.6
V
3.6
V
–2.1
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
ELECTRICAL CHARACTERISTICS (continued)
Minimum and maximum specifications apply from –40°C to +105°C. Typical specifications are at +25°C. All specifications are
at DVDD = 1.8 V, AVDD = 3 V, AVSS = 0 V, VREF = 2.4 V, external fCLK = 2.048 MHz, data rate = 8 kSPS, and gain = 1,
unless otherwise noted.
ADS131E0x
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
SUPPLY CURRENT (Operational Amplifier Turned Off)
IAVDD
Normal mode
IDVDD
AVDD – AVSS = 3 V
5.1
mA
AVDD – AVSS = 5 V
5.8
mA
DVDD = 3.3 V
1
mA
DVDD = 1.8 V
0.4
mA
Normal mode
9.3
Power-down mode
10
µW
2
mW
POWER DISSIPATION (Analog Supply = 3 V)
ADS131E04
Standby mode
Normal mode
Quiescent power
dissipation
ADS131E06
ADS131E08
12.7
Power-down mode
10.2
13.5
mW
mW
10
µW
Standby mode
2
mW
Normal mode
16
Power-down mode
10
µW
Standby mode
2
mW
Normal mode
18
mW
Power-down mode
20
µW
Standby mode
4.2
mW
Normal mode
24.3
mW
17.6
mW
POWER DISSIPATION (Analog Supply = 5 V)
ADS131E04
Quiescent power
dissipation
ADS131E06
ADS131E08
Power-down mode
20
µW
Standby mode
4.2
mW
Normal mode
29.7
mW
Power-down mode
20
µW
Standby mode
4.2
mW
TEMPERATURE
TA
TJ
Temperature range
Tstg
Specified
–40
+105
°C
Operating
–40
+105
°C
Storage
–60
+150
°C
THERMAL INFORMATION
ADS131E0x
THERMAL METRIC
(1)
PAG (TQFP)
UNITS
64 PINS
θJA
Junction-to-ambient thermal resistance
35
θJCtop
Junction-to-case (top) thermal resistance
31
θJB
Junction-to-board thermal resistance
26
ψJT
Junction-to-top characterization parameter
0.1
ψJB
Junction-to-board characterization parameter
NA
θJCbot
Junction-to-case (bottom) thermal resistance
NA
(1)
°C/W
For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
5
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
PARAMETER MEASUREMENT INFORMATION
NOISE MEASUREMENTS
The ADS131E0x noise performance can be optimized by adjusting the data rate and PGA setting. As the
averaging is increased by reducing the data rate, the noise drops correspondingly. Increasing the PGA value
reduces the input-referred noise, which is particularly useful when measuring low-level signals. Table 1
summarizes the ADS131E0x noise performance with a 3-V analog power supply. Table 2 summarizes the
ADS131E0x noise performance with a 5-V analog power supply. The data are representative of typical noise
performance at TA = +25°C. The data shown are the result of averaging the readings from multiple devices and
are measured with the inputs shorted together. A minimum of 1000 consecutive readings are used to calculate
the RMS and peak-to-peak noise for each reading. For the two highest data rates, the noise is limited by ADC
quantization noise and does not have a Gaussian distribution. Table 1 and Table 2 show measurements taken
with an internal reference. The data are also representative of the ADS131E0x noise performance when using a
low-noise external reference, such as the REF5025.
Table 1. Input-Referred Noise, 3-V Analog Supply, and 2.4-V Reference (1)
PGA GAIN
DR BITS
(CONFIG1
Register)
OUTPUT
DATA
RATE
(kSPS)
–3-dB
BANDWIDTH
(Hz)
DYNAMIC
RANGE (dB)
000
64
16768
74.1
001
32
8384
010
16
011
(1)
x1
x2
ENOB
DYNAMIC
RANGE (dB)
12.31
74.1
89.6
14.89
4192
102.8
8
2096
100
4
101
110
x4
ENOB
DYNAMIC
RANGE (dB)
12.30
74.0
89.6
14.88
17.07
102.3
108.2
18.0
1048
111.4
2
524
1
262
x8
ENOB
DYNAMIC
RANGE (dB)
12.29
74.0
89.4
14.85
16.99
100.6
107.4
17.9
18.6
109.4
114.6
19.1
117.7
19.6
x12
ENOB
DYNAMIC
RANGE (dB)
ENOB
12.29
73.9
12.27
88.6
14.71
87.6
14.55
16.72
97.1
16.12
94.2
15.65
105.2
17.5
101.6
16.9
98.9
16.5
18.4
107.4
18.1
103.5
17.4
100.5
17.0
113.7
19.0
111.4
18.6
107.7
18.0
104.9
17.5
116.8
19.5
114.5
19.1
110.7
18.5
108.0
18.0
At least 1000 consecutive readings were used to calculate the peak-to-peak noise values in this table.
Table 2. Input-Referred Noise, 5-V Analog Supply, and 4-V Reference
PGA GAIN
6
DR BITS
(CONFIG1
Register)
OUTPUT
DATA
RATE
(kSPS)
–3-dB
BANDWIDTH
(Hz)
DYNAMIC
RANGE (dB)
000
64
16768
74.7
001
32
8384
010
16
011
x1
x2
ENOB
DYNAMIC
RANGE (dB)
12.41
74.7
90.3
15.01
4192
104.3
8
2096
100
4
101
110
x4
ENOB
DYNAMIC
RANGE (dB)
12.41
74.7
90.3
15.00
17.33
104.0
112.3
18.7
1048
116.0
2
524
1
262
x8
ENOB
DYNAMIC
RANGE (dB)
12.41
74.7
90.2
14.99
17.28
103.1
111.6
18.6
19.3
115.2
119.1
19.8
122.1
20.4
Submit Documentation Feedback
x12
ENOB
DYNAMIC
RANGE (dB)
ENOB
12.41
74.6
12.39
89.9
14.93
89.4
14.85
17.12
100.5
16.70
98.1
16.30
109.7
18.3
106.3
17.7
103.8
17.3
19.2
113.1
18.8
109.5
18.3
106.9
17.8
118.2
19.7
116.2
19.4
112.6
18.8
109.9
18.3
121.3
20.2
119.1
19.9
115.6
19.3
112.9
18.8
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
TIMING CHARACTERISTICS
tCLK
CLK
t CSSC
1
2
8
3
t DIHD
t DIST
t SPWL
t SPWH
t SCLK
SCLK
t CSH
t SDECODE
CS
1
2
t SCCS
3
t DOHD
8
t DOST
DIN
t CSDOZ
t CSDOD
DOUT
Hi-Z
Hi-Z
NOTE: SPI settings are CPOL = 0 and CPHA = 1.
Figure 1. Serial Interface Timing
tDISCK2ST
DAISY_IN
SCLK
1
tDISCK2HT
LSB
MSB
2
3
n
n+1
n+3
n+2
tDOST
DOUT
MSB
LSB
0
MSB
(1) n = Number of channels × resolution + 24 bits. Number of channels is 4, 6, or 8; resolution is 16-bit or 24-bit.
Figure 2. Daisy-Chain Interface Timing
Timing Requirements For Figure 1 and Figure 2 (1)
2.7 V ≤ DVDD ≤ 3.6 V
PARAMETER
DESCRIPTION
tCLK
Master clock period
tCSSC
CS low to first SCLK: setup time
tSCLK
tSPWH,
1.7 V ≤ DVDD ≤ 2.0 V
MIN
MAX
MIN
MAX
UNIT
444
588
444
588
ns
6
17
ns
SCLK period
50
66.6
ns
SCLK pulse width, high and low
15
25
ns
tDIST
DIN valid to SCLK falling edge: setup time
10
10
ns
tDIHD
Valid DIN after SCLK falling edge: hold time
10
11
ns
tDOHD
SCLK falling edge to invalid DOUT: hold time
10
10
ns
tDOST
SCLK rising edge to DOUT valid: setup time
tCSH
CS high pulse
tCSDOD
CS low to DOUT driven
tSCCS
tSDECODE
tCSDOZ
CS high to DOUT Hi-Z
tDISCK2ST
Valid DAISY_IN to SCLK rising edge: setup time
10
10
ns
tDISCK2HT
Valid DAISY_IN after SCLK rising edge: hold time
10
10
ns
(1)
L
17
32
ns
2
2
tCLKs
10
20
ns
Eighth SCLK falling edge to CS high
4
4
tCLKs
Command decode time
4
4
10
tCLKs
20
ns
Specifications apply from –40°C to +105°C, unless otherwise noted. Load on DOUT = 20 pF || 100 kΩ.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
7
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
PIN CONFIGURATIONS
AVSS
AVSS
AVDD
VCAP3
AVDD1
AVSS1
CLKSEL
DGND
DVDD
58
57
56
55
54
53
52
51
50
49 DGND
OPAMPP
AVDD
59
OPAMPN
61
60
NC
62
63 OPAMPOUT
64
NC
PAG PACKAGE
TQFP-32
(TOP VIEW)
DAISY_IN
IN4N
9
40
SCLK
IN4P 10
39
CS
IN3N 11
38
START
IN3P 12
37
CLK
IN2N 13
36
RESET
IN2P 14
35
PWDN
IN1N 15
34
DIN
IN1P 16
33
DGND
AVSS 32
41
31
8
RESV1
IN5P
30
GPIO1
VCAP2
42
29
7
NC
IN5N
VCAP1
DOUT
28
43
27
6
NC
IN6P
26
GPIO2
VCAP4
44
25
5
VREFN
IN6N
24
GPIO3
VREFP
45
23
4
AVSS
IN7P
AVDD
GPIO4
22
46
21
3
AVDD
IN7N
20
DRDY
AVSS
47
19
2
AVDD
IN8P
18
DVDD
TESTN
48
17
1
TESTP
IN8N
PIN ASSIGNMENTS
8
NAME
TERMINAL
FUNCTION
DESCRIPTION
AVDD
19, 21, 22, 56, 59
Supply
Analog supply
AVDD1
54
Supply
Charge pump analog supply
AVSS
20, 23, 32, 57, 58
Supply
Analog ground
AVSS1
53
Supply
Charge pump analog ground
CS
39
Digital input
SPI chip select; active low
CLK
37
Digital input
Master clock input
CLKSEL
52
Digital input
Master clock select
DAISY_IN
41
Digital input
Daisy-chain input
DGND
33, 49, 51
Supply
DIN
34
Digital input
DOUT
43
Digital output
SPI data out
DRDY
47
Digital output
Data ready; active low
DVDD
48, 50
Supply
Submit Documentation Feedback
Digital ground
SPI data in
Digital power supply
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
PIN ASSIGNMENTS (continued)
NAME
TERMINAL
FUNCTION
GPIO1
42
Digital input/output
General-purpose input/output pin
GPIO2
44
Digital input/output
General-purpose input/output pin
GPIO3
45
Digital input/output
General-purpose input/output pin
GPIO4
46
Digital input/output
General-purpose input/output pin
(1)
15
Analog input
Differential analog negative input 1
IN1P (1)
16
Analog input
Differential analog positive input 1
IN2N (1)
13
Analog input
Differential analog negative input 2
(1)
14
Analog input
Differential analog positive input 2
IN3N (1)
11
Analog input
Differential analog negative input 3
IN3P (1)
12
Analog input
Differential analog positive input 3
IN4N (1)
9
Analog input
Differential analog negative input 4
IN4P
(1)
10
Analog input
Differential analog positive input 4
IN5N
(1)
7
Analog input
Differential analog negative input 5
(ADS131E06 and ADS131E08 only)
IN5P (1)
8
Analog input
Differential analog positive input 5 (ADS131E06 and ADS131E08 only)
(1)
5
Analog input
Differential analog negative input 6
(ADS131E06 and ADS131E08 only)
IN6P (1)
6
Analog input
Differential analog positive input 6 (ADS131E06 and ADS131E08 only)
(1)
3
Analog input
Differential analog negative input 7 (ADS131E08 only)
IN7P (1)
4
Analog input
Differential analog positive input 7 (ADS131E08 only)
IN8N (1)
1
Analog input
Differential analog negative input 8 (ADS131E08 only)
Differential analog positive input 8 (ADS131E08 only)
IN1N
IN2P
IN6N
IN7N
IN8P
(1)
2
Analog input
NC
27, 29, 62, 64
—
OPAMPN
61
Analog
No connection, leave floating
Op amp inverting input
OPAMPP
60
—
OPAMPOUT
63
Analog
PWDN
35
Digital input
Power-down; active low
RESET
36
Digital input
System reset; active low
RESV1
31
Digital input
Reserved for future use; must tie to logic low (DGND)
SCLK
40
Digital input
SPI clock
START
38
Digital input
Start conversion
(1)
18
Analog input/output
Internal test signal, negative signal
TESTP (1)
17
Analog input/output
Internal test signal, positive signal
VCAP1
28
Analog input/output
Analog bypass capacitor
VCAP2
30
—
Analog bypass capacitor
VCAP3
55
—
Analog bypass capacitor
VCAP4
26
Analog output
Analog bypass capacitor
VREFN
25
Analog input
Negative reference voltage
VREFP
24
Analog input/output
Positive reference voltage
TESTN
(1)
DESCRIPTION
Op amp noninverting input
Op amp output
Connect unused terminals to AVDD.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
9
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
TYPICAL CHARACTERISTICS
All plots are at TA = +25°C, AVDD = 3 V, AVSS = 0 V, DVDD = 1.8 V, internal VREFP = 2.4 V, VREFN = AVSS, external
clock = 2.048 MHz, data rate = 8 kSPS, and gain = 1, unless otherwise noted.
INPUT-REFERRED NOISE
NOISE HISTOGRAM
10
2200
Data Rate = 1 kSPS
Gain = 1
6
1800
4
1600
2
0
−2
−4
1400
1200
1000
800
600
−6
400
−8
200
0
1
2
3
4
5
6
Time (s)
7
8
9
0
10
−9
−8
−7
−6
−5
−4
−3
−2
−1
0
1
2
3
4
5
6
7
8
9
−10
Data Rate = 1 kSPS
Gain = 1
2000
Occurences
Input−Referred Noise (µV)
8
G003
Input−Referred Noise (µV)
G004
Figure 3.
Figure 4.
CMRR vs FREQUENCY
THD vs FREQUENCY
−90
−75
CMRR (dB)
−100
−105
Total Harmonic Distortion (dB)
Gain = 1
Gain = 2
Gain = 4
Gain = 8
Gain = 12
−95
−110
−115
−120
Data Rate = 4 kSPS
AIN = AVDD − 0.3 V to AVSS + 0.3 V
−125
−130
10
100
Frequency (Hz)
−80
−85
−90
−95
1000
Gain = 1
Gain = 2
Gain = 4
Gain = 8
Gain = 12
10
100
Frequency (Hz)
G005
Figure 5.
PSRR vs FREQUENCY
INL vs PGA GAIN
G=4
G=8
G = 12
Integral Nonlinearity (ppm)
Power−Supply Rejection Ratio (dB)
G=1
G=2
100
95
90
85
80
10
100
Frequency (Hz)
1000
G007
14
12
10
8
6
4
2
0
−2
−4
−6
−8
−10
−12
−14
Gain = 1
Gain = 2
Gain = 4
Gain = 8
Gain = 12
−1
−0.8 −0.6 −0.4 −0.2 0
0.2 0.4 0.6
Input (Normalized to Full−Scale)
Figure 7.
10
Submit Documentation Feedback
G006
Figure 6.
110
105
1000
0.8
1
G008
Figure 8.
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
TYPICAL CHARACTERISTICS (continued)
All plots are at TA = +25°C, AVDD = 3 V, AVSS = 0 V, DVDD = 1.8 V, internal VREFP = 2.4 V, VREFN = AVSS, external
clock = 2.048 MHz, data rate = 8 kSPS, and gain = 1, unless otherwise noted.
INL vs TEMPERATURE
THD FFT PLOT
0
−40°C
+105°C
+25°C
16
PGA Gain = 1
THD = −97 dB
SNR = 117 dB
Data Rate = 1 kSPS
−20
−40
Amplitude (dBFS)
Integral Nonlinearity (ppm)
24
8
0
−8
−60
−80
−100
−120
−140
−16
−160
−24
−1
−0.8 −0.6 −0.4 −0.2 0
0.2 0.4 0.6
Input (Normalized to Full−Scale)
0.8
−180
1
0
100
200
300
Frequency (Hz)
G009
Figure 9.
500
G010
Figure 10.
FFT PLOT
OFFSET vs PGA GAIN (Absolute Value)
0
600
PGA Gain = 1
THD = −96 dB
SNR = 74 dB
Data Rate = 64 kSPS
−20
−40
AVDD = 3 V
AVDD = 5 V
500
−60
400
Offset (µV)
Amplitude (dBFS)
400
−80
−100
−120
300
200
−140
100
−160
−180
0
2
4
6
0
8 10 12 14 16 18 20 22 24 26 28 30 32
Frequency (kHz)
G011
1
2
3
4
5
Figure 11.
OFFSET DRIFT vs PGA GAIN
9
10
11
12
G012
ADS131E08 CHANNEL POWER
32
AVDD = 3 V
AVDD = 5 V
800
AVDD = 3 V
AVDD = 5 V
28
700
24
600
Power (mW)
Offset Drift (nV/°C)
8
Figure 12.
900
500
400
300
20
16
12
200
8
100
4
0
6
7
PGA Gain
1
2
3
4
5
6
7
PGA Gain
8
9
10
11
12
G013
0
0
1
2
3
4
5
6
Number of Channels Disabled
Figure 13.
Copyright © 2012, Texas Instruments Incorporated
7
8
G014
Figure 14.
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
11
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
OVERVIEW
The ADS131E0x are low-power, multichannel, simultaneously-sampling, 24- and 16-bit delta-sigma (ΔΣ), analogto-digital converters (ADCs) with an integrated programmable gain amplifier (PGA). This functionality makes
these devices well-suited for smart-grid and other industrial power monitor, control, and protection applications.
The ADS131E0x have a highly-programmable multiplexer that allows for temperature, supply, and input short
measurements. The PGA gain can be chosen from one of five settings (1, 2, 4, 8, and 12). The ADCs in the
device offer data rates of 1, 2, 4, 8, 16, 32, and 64 kSPS. Device communication is accomplished using an SPIcompatible interface. The device provides four general-purpose I/O (GPIO) pins for general use. Multiple devices
can be synchronized using the START pin.
The internal reference can be programmed to either 2.4 V or 4 V. The internal oscillator generates a 2.048-MHz
clock. Open-circuit detection can be accomplished by using the integrated comparators, with programmable
trigger-point settings. A detailed diagram of the ADS131E0x is shown in Figure 15.
AVDD AVDD1
DVDD
VREFP VREFN
Test Signal
Temperature
Fault Detect
Supply Check
Refer ence
DRDY
IN1P
EMI
Filter
∆Σ
ADC1
PGA1
IN1N
SPI
IN2P
EMI
Filter
PGA2
∆Σ
ADC2
EMI
Filter
PGA3
∆Σ
ADC3
PGA4
∆Σ
ADC4
PGA5
∆Σ
ADC5
CS
SCLK
DIN
DOUT
IN2N
IN3P
IN3N
CLKSEL
IN4P
EMI
Filter
IN4N
Control
Oscillator
MUX
GPIO1
IN5P
EMI
Filter
ADS131E06/8
CLK
GPIO2
GPIO3
IN5N
GPIO4
IN6P
EMI
Filter
∆Σ
ADC6
PGA6
IN6N
PWDN
ADS131E08
IN7P
EMI
Filter
PGA7
EMI
Filter
PGA8
∆Σ
ADC7
RESET
IN7N
START
IN8P
∆Σ
ADC8
IN8N
Operational
Amplifi er
OPAMPOUT
AVSS AVSS1
OPAMPN
OPAMPP
DGND
Figure 15. Functional Block Diagram
12
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
THEORY OF OPERATION
This section contains details of the ADS131E0x internal functional elements. The analog blocks are discussed
first, followed by the digital interface. Information on implementing power monitoring specific applications is
covered towards the end of this document.
Throughout this document, fCLK denotes the signal frequency at the CLK pin, tCLK denotes the signal period at the
CLK pin, fDR denotes the output data rate, tDR denotes the output data time period, and fMOD denotes the
frequency at which the modulator samples the input.
EMI FILTER
An RC filter at the input acts as an EMI filter on all channels. The –3-dB filter bandwidth is approximately
3 MHz.
INPUT MULTIPLEXER
The ADS131E0x input multiplexers are very flexible and provide many configurable signal switching options.
Figure 16 shows a diagram of the multiplexer on a single channel of the device. VINP and VINN are separate for
each of the eight blocks. This flexibility allows for significant device and sub-system diagnostics, calibration, and
configuration. Switch settings for each channel are selected by writing the appropriate values to the CHnSET
register (see the CHnSET Register in the Register Map section for details.)
Device
MUX
INT_TEST
TESTP
INT_TEST
MUX[2:0] = 101
TestP
MUX[2:0] = 100
TempP
MvddP
MUX[2:0] = 011
(1)
MUX[2:0] = 000
VINP
MUX[2:0] = 001
EMI
Filter
(VREFP + VREFN)
2
MUX[2:0] = 000
VINN
MvddN
To PgaP
MUX[2:0] = 001
To PgaN
MUX[2:0] = 011
(1)
MUX[2:0] = 100
TempN
MUX[2:0] = 101
TestN
INT_TEST
TESTN
INT_TEST
(1) MVDD monitor voltage supply depends on channel number; see the Supply Measurements (MVDDP, MVDDN) section.
Figure 16. Input Multiplexer Block for One Channel
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
13
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
Device Noise Measurements
Setting CHnSET[2:0] = 001 sets the common-mode voltage of [(VREFP + VREFN) / 2] to both channel inputs.
This setting can be used to test inherent device noise in the user system.
Test Signals (TestP and TestN)
Setting CHnSET[2:0] = 101 provides internally-generated test signals for use in sub-system verification at powerup. Test signals are controlled through register settings (see the CONFIG2: Configuration Register 2 subsection
in the Register Map section for details). TEST_AMP controls the signal amplitude and TEST_FREQ controls
switching at the required frequency. The test signals are multiplexed and transmitted out of the device at the
TESTP and TESTN pins. A bit register (CONFIG2.INT_TEST = 0) deactivates the internal test signals so that the
test signal can be driven externally. This feature allows the calibration of multiple devices with the same signal.
Temperature Sensor (TempP, TempN)
The ADS131E0x contain an on-chip temperature sensor. This sensor uses two internal diodes with one diode
having a current density 16x that of the other, as shown in Figure 17. The difference in diode current densities
yields a difference in voltage that is proportional to absolute temperature.
As a result of the low thermal resistance of the package to the printed circuit board (PCB), the internal device
temperature tracks the PCB temperature closely. Note that self-heating of the ADS131E0x causes a higher
reading than the temperature of the surrounding PCB.
The scale factor of Equation 1 converts the temperature reading to °C. Before using this equation, the
temperature reading code must first be scaled to μV.
Temperature (°C) =
Temperature Reading (mV) - 168,000 mV
394 mV/°C
+ 25°C
(1)
Temperature Sensor Monitor
AVDD
1x
2x
To MUX TempP
To MUX TempN
8x
1x
AVSS
Figure 17. Temperature Sensor Measurement in the Input
Supply Measurements (MVDDP, MVDDN)
Setting CHnSET[2:0] = 011 sets the channel inputs to different device supply voltages. For channels 1, 2, 5, 6, 7,
and 8, (MVDDP – MVDDN) is [0.5(AVDD – AVSS)]; for channels 3 and 4, (MVDDP – MVDDN) is
DVDD / 4. Note that to avoid saturating the PGA while measuring power supplies, the gain must be set to '1'.
14
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
ANALOG INPUT
The ADS131E0x analog input is fully differential. Assuming PGA = 1, the differential input (INP – INN) can span
between –VREF to +VREF. Refer to Table 5 for an explanation of the correlation between the analog input and
digital codes. There are two general methods of driving the ADS131E0x analog input: single-ended or
differential, as shown in Figure 18 and Figure 19, respectively. Note that INP and INN are 180°C out-of-phase in
the differential input method. When the input is single-ended, the INN input is held at the common-mode voltage,
preferably at mid-supply. The INP input swings around the same common voltage and the peak-to-peak
amplitude is (common-mode + 1/2 VREF) and (common-mode – 1/2 VREF). When the input is differential, the
common-mode is given by [(INP + INN) / 2]. Both INP and INN inputs swing from (common-mode + 1/2 VREF to
common-mode – 1/2 VREF). For optimal performance, it is recommended that the ADS131E0x be used in a
differential configuration.
1/2 VREF
to
+1/2 VREF
VREF
Peak-to-Peak
Device
Device
Common
Voltage
Common
Voltage
VREF
Peak-to-Peak
a) Single-Ended Input
b) Differential Input
Figure 18. Methods of Driving the ADS131E0x: Single-Ended or Differential
CM + 1/2 VREF
+1/2 VREF
INP
CM Voltage
CM
1/2 VREF
1/2 VREF
INN = CM Voltage
t
Single-Ended Inputs
CM + 1/2 VREF
INP
+VREF
CM Voltage
CM
1/2 VREF
VREF
INN
t
Differential Inputs
Common-Mode Voltage (Differential Mode) =
(INP) + (INN)
, Common-Mode Voltage (Single-Ended Mode) = INN
2
Input Range (Differential Mode) = (AINP – AINN) = 2 VREF
Figure 19. Using the ADS131E0x in Single-Ended and Differential Input Modes
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
15
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
PGA SETTINGS AND INPUT RANGE
The PGA is a differential input and output amplifier, as shown in Figure 20. It has five gain settings (1, 2, 4, 8,
and 12) that can be set by writing to the CHnSET register (see the CHnSET Register in the Register Map section
for details). The ADS131E0x have CMOS inputs and therefore have negligible current noise. Table 3 shows the
typical bandwidth values for various gain settings. Note that Table 3 shows small-signal bandwidth. For large
signals, performance is limited by PGA slew rate.
The PGA resistor string that implements the gain has 120 kΩ of resistance for a gain of 2. This resistance
provides a current path across the PGA outputs in the presence of a differential input signal. This current is in
addition to the quiescent current specified for the device in the presence of a differential signal at the input.
From MuxP
PgaP
R2
30 kΩ
R1
60 kΩ
(for Gain = 2)
PgaN
To ADC
R2
30 kΩ
From MuxN
Figure 20. PGA Implementation
Table 3. PGA Gain versus Bandwidth
16
GAIN
NOMINAL BANDWIDTH AT ROOM TEMPERATURE (kHz)
1
237
2
146
4
96
8
48
12
32
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
Input Common-Mode Range
The usable input common-mode range of the analog front-end depends on various parameters, including the
maximum differential input signal, supply voltage, and PGA gain. This range is described in Equation 2:
Gain VMAX_DIFF
Gain VMAX_DIFF
AVDD - 0.3 > CM > AVSS + 0.3 +
2
2
where:
VMAX_DIFF = maximum differential signal at the PGA input
CM = common-mode range
(2)
For example:
If VDD = 3.3 V, gain = 2, and VMAX_DIFF = 1000 mV,
Then 1.3 V < CM < 2.0 V
Input Differential Dynamic Range
The differential (INP – INN) signal range depends on the analog supply and reference used in the system. This
range is shown in Equation 3.
VREF
±VREF 2 VREF
Max (INP - INN) <
;
Full-Scale Range =
=
Gain
Gain
Gain
(3)
For higher dynamic range, a 5-V supply with a 4-V reference (set by the VREF_4V bit of the CONFIG3 register)
can be used to increase the differential dynamic range.
ADC ΔΣ Modulator
Power Spectral Density (dB)
Each ADS131E0x channel has a ΔΣ ADC. This converter uses a second-order modulator optimized for lowpower applications. The modulator samples the input signal at the rate of [fMOD = fCLK / 2]. As in the case of any
ΔΣ modulator, the ADS131E0x noise is shaped until fMOD / 2, as shown in Figure 21. The on-chip digital
decimation filters also provide antialias filtering. This ΔΣ converter feature drastically reduces the complexity of
the analog antialiasing filters typically required with nyquist ADCs.
0
−10
−20
−30
−40
−50
−60
−70
−80
−90
−100
−110
−120
−130
−140
−150
−160
0.001
0.01
0.1
Normalized Frequency (fIN/fMOD)
1
G001
Figure 21. Modulator Noise Spectrum Up To 0.5 × fMOD
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
17
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
DIGITAL DECIMATION FILTER
The digital filter receives the modulator output and decimates the data stream. By adjusting the amount of
filtering, tradeoffs can be made between resolution and data rate: filter more for higher resolution, filter less for
higher data rates. Higher data rates are typically used in power applications that implement software phase
adjustment.
The digital filter on each channel consists of a third-order sinc filter. The decimation ratio on the sinc filters can
be adjusted by the DR bits in the CONFIG1 register (see the Register Map section for details). This setting is a
global setting that affects all channels and, therefore, all channels operate at the same data rate in the device.
Sinc Filter Stage (sinx / x)
The sinc filter is a variable decimation rate, third-order, low-pass filter. Data are supplied to this section of the
filter from the modulator at the rate of fMOD. The sinc filter attenuates the high-frequency modulator noise, then
decimates the data stream into parallel data. The decimation rate affects the overall converter data rate.
Equation 4 shows the scaled sinc filter Z-domain transfer function.
½H(z)½ =
1 - Z- N
3
1 - Z- 1
(4)
The sinc filter frequency domain transfer function is shown in Equation 5.
3
sin
½H(f)½ =
Npf
fMOD
N ´ sin
pf
fMOD
where:
N = decimation ratio
18
(5)
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
The sinc filter has notches (or zeroes) that occur at the output data rate and multiples thereof. At these
frequencies, the filter has infinite attenuation. Figure 22 shows the sinc filter frequency response and Figure 23
shows the sinc filter roll-off. With a step change at the input, the filter takes 3 tDR to settle. After a rising edge of
the START signal, the filter takes tSETTLE time to output settled data. The filter settling times at various data rates
are discussed in the START subsection of the SPI Interface section. Figure 24 and Figure 25 show the filter
transfer function until fMOD / 2 and fMOD / 16, respectively, at different data rates. Figure 26 shows the transfer
function extended until 4 fMOD. It can be seen that the ADS131E0x passband repeats itself at every fMOD. The
input R-C antialiasing filters in the system should be chosen such that any interference in frequencies around
multiples of fMOD are attenuated sufficiently.
0
0
-20
-0.5
-1
Gain (dB)
Gain (dB)
-40
-60
-80
-1.5
-2
-100
-2.5
-120
-3
-140
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0
0.05
Normalized Frequency (fIN/fDR)
0.1
0.15
0.3
0.35
Figure 23. Sinc Filter Roll-Off
0
0
DR[2:0] = 110
DR[2:0] = 110
-20
DR[2:0] = 000
-40
DR[2:0] = 000
-40
Gain (dB)
Gain (dB)
0.25
Normalized Frequency (fIN/fDR)
Figure 22. Sinc Filter Frequency Response
-20
0.2
-60
-80
-60
-80
-100
-100
-120
-120
-140
-140
0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5
0
0.01
Normalized Frequency (fIN/fMOD)
Figure 24. Transfer Function of On-Chip
Decimation Filters Until fMOD / 2
10
0.02
0.03
0.04
0.05
0.06
0.07
Normalized Frequency (fIN/fMOD)
Figure 25. Transfer Function of On-Chip
Decimation Filters Until fMOD / 16
DR[2:0] = 000
DR[2:0] = 110
-10
Gain (dB)
-30
-50
-70
-90
-110
-130
0
0.5
1
1.5
2
2.5
3
3.5
4
Normalized Frequency (fIN/fMOD)
Figure 26. Transfer Function of On-Chip Decimation Filters
Until 4 fMOD for DR[2:0] = 000 and DR[2:0] = 110
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
19
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
REFERENCE
Figure 27 shows a simplified block diagram of the internal ADS131E0x reference. The reference voltage is
generated with respect to AVSS. When using the internal voltage reference, connect VREFN to AVSS.
22 F
VCAP1
R1
(1)
Bandgap
2.4 V or 4 V
R3
VREFP
(1)
10 F
R2
(1)
VREFN
AVSS
To ADC Reference Inputs
(1) For VREF = 2.4 V: R1 = 12.5 kΩ, R2 = 25 kΩ, and R3 = 25 kΩ. For VREF = 4 V: R1 = 10.5 kΩ, R2 = 15 kΩ, and R3 = 35 kΩ.
Figure 27. Internal Reference
The external band-limiting capacitors determine the amount of reference noise contribution. For high-end
systems, the capacitor values should be chosen such that the bandwidth is limited to less than 10 Hz, so that the
reference noise does not dominate the system noise. When using a 3-V analog supply, the internal reference
must be set to 2.4 V. In case of a 5-V analog supply, the internal reference can be set to 4 V by setting the
VREF_4V bit in the CONFIG2 register.
Alternatively, the internal reference buffer can be powered down and VREFP can be driven externally. Figure 28
shows a typical external reference drive circuitry. Power-down is controlled by the PD_REFBUF bit in the
CONFIG3 register. This power-down is also used to share internal references when two devices are cascaded.
By default, the device wakes up in external reference mode.
100 kΩ
10 pF
+5 V
0.1 µF
100 Ω
OPA211
100 Ω
+5 V
VIN
22 µF
REF5025
TRIM
To VREFP Pin
10 µF
OUT
0.1 µF
100 µF
22 µF
Figure 28. External Reference Driver
20
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
CLOCK
The ADS131E0x provide two different device clocking methods: internal and external. Internal clocking is ideally
suited for low-power, battery-powered systems. The internal oscillator is trimmed for accuracy at room
temperature. Accuracy varies over the specified temperature range; refer to the Electrical Characteristics for
details. Clock selection is controlled by the CLKSEL pin and the CLK_EN register bit.
The CLKSEL pin selects either the internal or external clock. The CLK_EN bit in the CONFIG1 register enables
and disables the oscillator clock to be output in the CLK pin. A truth table for these two pins is shown in Table 4.
The CLK_EN bit is useful when multiple devices are used in a daisy-chain configuration. It is recommended that
during power-down the external clock be shut down to save power.
Table 4. CLKSEL Pin and CLK_EN Bit
CLKSEL PIN
CONFIG1.CLK_EN
BIT
CLOCK SOURCE
CLK PIN STATUS
0
X
External clock
Input: external clock
1
0
Internal clock oscillator
3-state
1
1
Internal clock oscillator
Output: internal clock oscillator
DATA FORMAT
The ADS131E0x output resolution is dependent upon the DR[2:0] bit setting in the CONFIG1 register. When
DR[2:0] = 000 or 001, the 16 bits of data per channel are sent in binary twos complement format, MSB first. The
LSB has a weight of VREF / (215 – 1). A positive full-scale input produces an output code of 7FFFh and the
negative full-scale input produces an output code of 8000h. The output clips at these codes for signals exceeding
full-scale. Table 5 summarizes the ideal output codes for different input signals. All 16 bits toggle when the
analog input is at positive or negative full-scale.
Table 5. Ideal Output Code versus Input Signal, LSB Weight = VREF / (215 – 1)
INPUT SIGNAL, VIN
(AINP – AINN)
IDEAL OUTPUT CODE (1) (2)
≥ VREF
7FFFh
15
+VREF / (2
(1)
(2)
– 1)
0001h
0
0000h
–VREF / (215 – 1)
FFFFh
≤ –VREF (215 / 215 – 1)
8000h
Assumes gain = 1.
Excludes effects of noise, linearity, offset, and gain error.
When DR[2:0] = 010, 011, 100, 101, or 110, the ADS131E0x outputs 24 bits of data per channel in binary twos
complement format, MSB first. The LSB has a weight of VREF / (223 – 1). A positive full-scale input produces an
output code of 7FFFFFh and the negative full-scale input produces an output code of 800000h. The output clips
at these codes for signals exceeding full-scale. Table 6 summarizes the ideal output codes for different input
signals.
Table 6. Ideal Output Code versus Input Signal, LSB Weight = VREF / (223 – 1)
INPUT SIGNAL, VIN
(AINP – AINN)
IDEAL OUTPUT CODE
≥ VREF
7FFFFFh
23
+VREF / (2
– 1)
000001h
0
000000h
–VREF / (223 – 1)
FFFFFFh
≤ –VREF (223 / 223 – 1)
800000h
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
21
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
SPI INTERFACE
The SPI-compatible serial interface consists of four signals: CS, SCLK, DIN, and DOUT. The interface reads
conversion data, reads and writes registers, and controls the ADS131E0x operation. The DRDY output is used
as a status signal to indicate when data are ready. DRDY goes low when new data are available.
Chip Select (CS)
Chip select (CS) selects the ADS131E0x for SPI communication. CS must remain low for the entire serial
communication duration. After the serial communication is finished, four or more tCLK cycles must elapse before
taking CS high. When CS is taken high, the serial interface is reset, SCLK and DIN are ignored, and DOUT
enters a high-impedance state. DRDY asserts when data conversion is complete, regardless of whether CS is
high or low.
Serial Clock (SCLK)
SCLK is the serial peripheral interface (SPI) serial clock. It is used to shift in commands and shift out data from
the device. The serial clock (SCLK) features a Schmitt-triggered input and clocks data on the DIN and DOUT
pins into and out of the ADS131E0x.
Care should be taken to prevent glitches on SCLK while CS is low. Glitches as small as 1 ns wide could be
interpreted as a valid serial clock. After eight serial clock events, the ADS131E0x assume an instruction must be
interrupted and executed. If it is suspected that instructions are being interrupted erroneously, toggle CS high
and back low to return the chip to normal operation. It is also recommended to issue serial clocks in multiples of
eight. The absolute maximum SCLK limit is specified in the Serial Interface Timing table.
For a single device, the minimum speed needed for SCLK depends on the number of channels, number of bits of
resolution, and output data rate. (For multiple cascaded devices, see the Standard Mode subsection of the
Multiple Device Configuration section.) The SCLK rate limitation, as described by Equation 6, applies to RDATAC
mode.
tSCLK < (tDR – 4 tCLK) / (NBITSNCHANNELS + 24)
(6)
For example, if the ADS131E0x is used in an 8-kSPS mode (eight channels, 24-bit resolution), the minimum
SCLK speed is 1.72 MHz.
Data retrieval can be done either by putting the device in RDATAC mode or by issuing an RDATA command for
data on demand. The SCLK rate limitation, as described by Equation 6, applies to RDATAC mode. For the
RDATA command, the limitation applies if data must be read in between two consecutive DRDY signals. The
above calculation assumes that there are no other commands issued in between data captures.
Data Input (DIN)
The data input pin (DIN) is used along with SCLK to communicate with the ADS131E0x (opcode commands and
register data). The device latches data on DIN on the SCLK falling edge.
22
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
Data Output (DOUT)
The data output pin (DOUT) is used with SCLK to read conversion and register data from the ADS131E0x. Data
on DOUT are shifted out on the SCLK rising edge. DOUT goes to a high-impedance state when CS is high. In
read data continuous mode (see the SPI Command Definitions section for more details), the DOUT output line
also indicates when new data are available. This feature can be used to minimize the number of connections
between the device and system controller.
Figure 29 shows the ADS131E0x data output protocol.
DRDY
CS
SCLK
N SCLKS
DOUT
STAT
CH1
CH2
CH3
CH4
CH5
CH6
CH7
24-Bit
n-Bit
n-Bit
n-Bit
n-Bit
n-Bit
n-Bit
n-Bit
CH8
n-Bit
DIN
NOTE: N SCLKs = (N bits)(N channels) + 24 bits. N-bit is dependent upon the DR[2:0] registry bit settings (N = 16 or 24).
Figure 29. ADS131E0x SPI Bus Data Output (Eight Channels)
Data Retrieval
Data retrieval can be accomplished in one of two methods. The read data continuous command (see the
RDATAC: Read Data Continuous section) can be used to set the device in a mode to read the data continuously
without sending opcodes. The read data command (see the RDATA: Read Data section) can be used to read
just one data output from the device (see the SPI Command Definitions section for more details). The conversion
data are read by shifting the data out on DOUT. The MSB of the data on DOUT is clocked out on the first SCLK
rising edge. DRDY returns to high on the first SCLK falling edge. DIN should remain low for the entire read
operation.
The number of bits in the data output depends on the number of channels and the number of bits per channel.
For the ADS131E0x with 32- and 64-kSPS data rates, the number of data outputs is [(24 status bits + 16 bits × 8
channels) = 152 bits]. The format of the 24 status bits is (1100 + FAULT_STATP + FAULT_STATN + GPIO[7:4]).
The data format for each channel data are twos complement and MSB first. When channels are powered down
using the user register setting, the corresponding channel output is set to '0'. However, the sequence of channel
outputs remains the same. The last four (ADS131E04) or two (ADS131E06) channel outputs shown in Figure 29
are '0's.
The ADS131E0x also provide a multiple readback feature. The data can be read out multiple times by simply
giving more SCLKs, in which case the MSB data byte repeats after reading the last byte. The DAISY_IN bit in
the CONFIG1 register must be set to '1' for multiple readbacks.
Data Ready (DRDY)
DRDY is an output. When it transitions low, new conversion data are ready. The CS signal has no effect on the
data ready signal. DRDY behavior is determined by whether the device is in RDATAC mode or the RDATA
command is being used to read data on demand. (See the RDATAC: Read Data Continuous and RDATA: Read
Data subsections of the SPI Command Definitions section for further details).
When reading data with the RDATA command, the read operation can overlap the next DRDY occurrence
without data corruption.
The START pin or the START command is used to place the device either in normal data capture mode or pulse
data capture mode.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
23
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
Figure 30 shows the relationship between DRDY, DOUT, and SCLK during data retrieval (in case of an
ADS131E0x with a selected data rate that gives 16-bit resolution). DOUT is latched out at the SCLK rising edge;
DRDY is pulled high at the SCLK falling edge. Note that DRDY goes high on the first SCLK falling edge
regardless of whether data are being retrieved from the device or a command is being sent through the DIN pin.
For 24-bit resolution, the data starts from bit 215.
DRDY
DOUT
Bit 71
Bit 70
Bit 69
SCLK
Figure 30. DRDY with Data Retrieval (CS = 0)
GPIO
The ADS131E0x have a total of four general-purpose digital I/O (GPIO) pins available in the normal mode of
operation. The digital I/O pins are individually configurable as either inputs or outputs through the GPIOC bits
register. The GPIOD bits in the GPIO register control the level of the pins. When reading the GPIOD bits, the
data returned are the logic level of the pins, whether they are programmed as inputs or outputs. When the GPIO
pin is configured as an input, a write to the corresponding GPIOD bit has no effect. When configured as an
output, a write to the GPIOD bit sets the output value.
If configured as inputs, these pins must be driven (do not float). The GPIO pins are set as inputs after power-on
or after a reset. Figure 31 shows the GPIO port structure. The pins should be shorted to DGND if not used.
GPIO Data (Read)
GPIO Pin
GPIO Data (Write)
GPIO Control
Figure 31. GPIO Port Pin
Power-Down (PWDN)
When PWDN is pulled low, all on-chip circuitry is powered down. To exit power-down mode, take the PWDN pin
high. Upon exiting from power-down mode, the internal oscillator and the reference require time to wake up. It is
recommended that during power-down the external clock is shut down to save power.
Reset (RESET)
There are two methods to reset the ADS131E0x: pull the RESET pin low, or send the RESET opcode command.
When using the RESET pin, take it low to force a reset. Make sure to follow the minimum pulse width timing
specifications before taking the RESET pin back high. The RESET command takes effect on the eighth SCLK
falling edge of the opcode command. On reset it takes 18 tCLK cycles to complete initialization of the configuration
registers to the default states and start the conversion cycle. Note that an internal RESET is automatically issued
to the digital filter whenever the CONFIG1 register is set to a new value with a WREG command.
24
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
START
The START pin must be set high (for a minimum of 2 tCLKs) or the START command sent to begin conversions.
When START is low, or if the START command has not been sent, the device does not issue a DRDY signal
(conversions are halted).
When using the START opcode to control conversion, hold the START pin low. In multiple device configurations
the START pin is used to synchronize devices (see the Multiple Device Configuration subsection of the SPI
Interface section for more details).
Settling Time
The settling time (tSETTLE) is the time it takes for the converter to output fully-settled data when the START signal
is pulled high. Once START is pulled high, DRDY is also pulled high. The next DRDY falling edge indicates that
data are ready. Figure 32 shows the timing diagram and Table 7 shows the settling time for different data rates.
The settling time depends on fCLK and the decimation ratio (controlled by the DR[2:0] bits in the CONFIG1
register). Table 5 shows the settling time as a function of tCLK. Note that when START is held high and there is a
step change in the input signal, it takes 3 tDR for the filter to settle to the new value. Settled data are available on
the fourth DRDY pulse.
t SETTLE
START Pin
or
DIN
START Opcode
t DR
4/f CLK
DRDY
Figure 32. Settling Time
Table 7. Settling Time for Different Data Rates
DR[2:0]
SETTLING TIME
UNIT
000
152
tCLK
001
296
tCLK
010
584
tCLK
011
1160
tCLK
100
2312
tCLK
101
4616
tCLK
110
9224
tCLK
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
25
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
Continuous Mode
Conversions begin when the START pin is taken high or when the START opcode command is sent. As seen in
Figure 33, the DRDY output goes high when conversions are started and then goes low when data are ready.
Conversions continue indefinitely until the START pin is taken low or the STOP opcode command is transmitted.
When the START pin is pulled low or the stop command is issued, the conversion in progress is allowed to
complete. Figure 34 and Table 8 show the required DRDY timing to the START pin and the START and STOP
opcode commands when controlling conversions in this mode. To keep the converter running continuously, the
START pin can be permanently tied high.
START Pin
or
DIN
or
START(1)
Opcode
STOP(1)
Opcode
tDR
tSETTLE
DRDY
(1)
START and STOP opcode commands take effect on the seventh SCLK falling edge.
Figure 33. Continuous Conversion Mode
tSDSU
DRDY and DOUT
tDSHD
START Pin
or
STOP Opcode
(1)
STOP(1)
STOP(1)
START and STOP commands take effect on the seventh SCLK falling edge at the end of the opcode transmission.
Figure 34. START to DRDY Timing
Table 8. Timing Characteristics for Figure 34 (1)
SYMBOL
(1)
26
DESCRIPTION
MIN
UNIT
tSDSU
START pin low or STOP opcode to DRDY setup time
to halt further conversions
16
1/2 fMOD
tDSHD
START pin low or STOP opcode to complete current
conversion
16
1/2 fMOD
START and STOP commands take effect on the seventh SCLK falling edge at the end of the opcode transmission.
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
MULTIPLE DEVICE CONFIGURATION
The ADS131E0x are designed to provide configuration flexibility when multiple devices are used in a system.
The serial interface typically needs four signals: DIN, DOUT, SCLK, and CS. With one additional chip select
signal per device, multiple devices can be connected together. The number of signals needed to interface n
devices is 3 + n.
To use the internal oscillator in a daisy-chain configuration, one device must be set as the master for the clock
source with the internal oscillator enabled (CLKSEL pin = 1) and the internal oscillator clock brought out of the
device by setting the CLK_EN register bit to '1'. This master device clock is used as the external clock source for
the other devices.
When using multiple devices, the devices can be synchronized with the START signal. The delay from START to
the DRDY signal is fixed for a fixed data rate (see the START subsection of the SPI Interface section for more
details on the settling times). Figure 35 shows the behavior of two devices when synchronized with the START
signal.
There are two ways to connect multiple devices with an optimal number of interface pins: standard mode and
daisy-chain mode. Refer to the Standard Mode and Daisy-Chain Mode sections for details.
Device
START
CLK
START1
DRDY
DRDY1
CLK
Device
START2
DRDY
DRDY2
CLK
CLK
START
DRDY1
DRDY2
Figure 35. Synchronizing Multiple Converters
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
27
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
Standard Mode
Figure 36a shows a configuration with two devices cascaded together. Both devices are an ADS131E0x (eightchannel) device. Together, they create a system with 16 channels. DOUT, SCLK, and DIN are shared. Each
device has its own chip select. When a device is not selected by the corresponding CS being driven to logic 1,
the DOUT of this device is high-impedance. This structure allows the other device to take control of the DOUT
bus. This configuration method is suitable for the majority of applications.
Daisy-Chain Mode
Daisy-chain mode is enabled by setting the DAISY_IN bit in the CONFIG1 register. Figure 36b shows the daisychain configuration. In this mode SCLK, DIN, and CS are shared across multiple devices. The DOUT pin of
device 1 is connected to the DAISY_IN of device 0, thereby creating a daisy-chain for the data. One extra SCLK
must be issued between each data set. Also, when using daisy-chain mode, the multiple readback feature is not
available. Short the DAISY_IN pin to digital ground if not used. Figure 2 describes the required ADS131E0x
timing shown in Figure 36. Data from the ADS131E0x appear first on DOUT, followed by a don’t care bit, and
finally by the status and data words from the second ADS131E0x device.
When all devices in the chain operate in the same register setting, DIN can be shared as well and thereby
reduce the SPI communication signals to four, regardless of the number of devices. Furthermore, an external
clock must be used.
START(1)
CLK
START
CLK
INT
DRDY
CS
GPO0
START(1)
CLK
START
CLK
INT
DRDY
CS
GPO
GPO1
ADS13xE0x
(Device 0)
SCLK
SCLK
DIN
MOSI
DOUT0
MISO
ADS13xE0x
(Device 0)
DAISY_IN0
SCLK
SCLK
DIN
MOSI
DOUT0
MISO
Host Processor
START
CLK
DOUT1
DRDY
CS
START
SCLK
ADS13xE0x
(Device 1)
Host Processor
CS
SCLK
CLK
DIN
DRDY
DIN
ADS13xE0x
(Device 1)
DAISY_IN1
DOUT1
a) Standard Configuration
0
b) Daisy-Chain Configuration
(1) To reduce pin count, set the START pin low and use the START serial command to synchronize and start conversions.
Figure 36. Multiple Device Configurations
28
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
Note that from Figure 2, the SCLK rising edge shifts data out of the ADS131E0x on DOUT. The SCLK rising
edge is also used to latch data into the device DAISY_IN pin down the chain. This architecture allows for a faster
SCLK rate speed, but it also makes the interface sensitive to board-level signal delays. The more devices in the
chain, the more challenging it could become to adhere to setup and hold times. A star-pattern connection of
SCLK to all devices, minimizing length of DOUT, and other printed circuit board (PCB) layout techniques helps.
Placing delay circuits (such as buffers) between DOUT and DAISY_IN also helps mitigate this challenge. One
other option is to insert a D flip-flop between DOUT and DAISY_IN clocked on an inverted SCLK. Also note that
daisy-chain mode requires some software overhead to recombine data bits spread across byte boundaries.
Figure 37 shows a timing diagram for daisy-chain mode.
DOUT1
MSB1
DAISY_IN0
1
CLKS
DOUT
0
LSB1
2
3
n
n+1
LSB0
MSB0
n+2
XX
Data From First Device (ADS131E04/6/8)
n+3
MSB1
LSB1
Data From Second Device (ADS131E04/6/8)
NOTE: n = (number of channels) × (resolution) + 24 bits. The number of channels is 4, 6, or 8. Resolution is 16-bit or 24-bit.
Figure 37. Daisy-Chain Timing
The maximum number of devices that can be daisy-chained depends on the data rate at which the device is
operated at. The maximum number of devices can be approximately calculated with Equation 7.
fSCLK
NDEVICES =
fDR (NBITS)(NCHANNELS) + 24
where:
NBITS = device resolution (depends on RDR[1:0] setting),
and NCHANNELS = number of channels in the device (4, 6, or 8).
(7)
For example, when the ADS131E08 (eight-channel version) is operated at a 24-bit, 8-kSPS data rate with fSCLK =
10 MHz, up to six devices can be daisy-chained together.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
29
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
SPI COMMAND DEFINITIONS
The ADS131E0x provide flexible configuration control. The opcode commands, summarized in Table 9, control
and configure device operation. The opcode commands are stand-alone, except for the register read and register
write operations that require a second command byte plus data. CS can be taken high or held low between
opcode commands but must stay low for the entire command operation (especially for multibyte commands).
System opcode commands and the RDATA command are decoded by the ADS131E0x on the seventh SCLK
falling edge. The register read and write opcodes are decoded on the eighth SCLK falling edge. Be sure to follow
SPI timing requirements when pulling CS high after issuing a command.
Table 9. Command Definitions
COMMAND
DESCRIPTION
FIRST BYTE
SECOND BYTE
System Commands
WAKEUP
Wake-up from standby mode
0000 0010 (02h)
STANDBY
Enter standby mode
0000 0100 (04h)
RESET
Reset the device
0000 0110 (06h)
START
Start or restart (synchronize) conversions
0000 1000 (08h)
STOP
Stop conversion
0000 1010 (0Ah)
OFFSETCAL
Channel offset calibration
0001 1010 (1Ah)
Data Read Commands
RDATAC
Enable Read Data Continuous mode.
This mode is the default mode at power-up. (1)
0001 0000 (10h)
SDATAC
Stop Read Data Continuously mode
0001 0001 (11h)
RDATA
Read data by command; supports multiple read back.
0001 0010 (12h)
Register Read Commands
RREG
WREG
(1)
(2)
Read n nnnn registers starting at address r rrrr
001r rrrr (2xh) (2)
000n nnnn (2)
Write n nnnn registers starting at address r rrrr
(2)
000n nnnn (2)
010r rrrr (4xh)
When in RDATAC mode, the RREG command is ignored.
n nnnn = number of registers to be read or written – 1. For example, to read or write three registers, set n nnnn = 0 (0010). r rrrr =
starting register address for read and write opcodes.
WAKEUP: Exit STANDBY Mode
This opcode exits low-power standby mode; see the STANDBY: Enter STANDBY Mode subsection of the SPI
Command Definitions section. Be sure to allow enough time for all circuits in shutdown mode to power up (see
the Electrical Characteristics for details). There are no SCLK rate restrictions for this command and it can be
issued at any time. Any following command must be sent after 4 tCLK cycles.
STANDBY: Enter STANDBY Mode
This opcode command enters low-power standby mode. All parts of the circuit are shut down except for the
reference section. The standby mode power consumption is specified in the Electrical Characteristics. There are
no SCLK rate restrictions for this command and it can be issued at any time. Do not send any other
command other than the wakeup command after the device enters standby mode.
RESET: Reset Registers to Default Values
This command resets the digital filter cycle and returns all register settings to default values. See the Reset
(RESET) subsection of the SPI Interface section for more details. There are no SCLK rate restrictions for this
command and it can be issued at any time. It takes 18 tCLK cycles to execute the RESET command. Avoid
sending any commands during this time.
30
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
START: Start Conversions
This opcode starts data conversions. Tie the START pin low to control conversions by command. If conversions
are in progress, this command has no effect. The STOP opcode command is used to stop conversions. If the
START command is immediately followed by a STOP command, then have a gap of 4 tCLK cycles between them.
When the START opcode is sent to the device, keep the START pin low until the STOP command is issued.
(See the START subsection of the SPI Interface section for more details.) There are no SCLK rate restrictions
for this command and it can be issued at any time.
STOP: Stop Conversions
This opcode stops conversions. Tie the START pin low to control conversions by command. When the STOP
command is sent, the conversion in progress completes and further conversions are stopped. If conversions are
already stopped, this command has no effect. There are no SCLK rate restrictions for this command and it
can be issued at any time.
OFFSETCAL: Channel Offset Calibration
This command is used to cancel the channel offset. OFFSETCAL must be executed every time there is a change
in PGA gain settings.
RDATAC: Read Data Continuous
This opcode enables the conversion data output on each DRDY without the need to issue subsequent read data
opcodes. This mode places the conversion data in the output register and may be shifted out directly. The read
data continuous mode is the default mode of the device and the device defaults in this mode on power-up.
RDATAC mode is cancelled by the Stop Read Data Continuous command. If the device is in RDATAC mode, an
SDATAC command must be issued before any other commands can be sent to the device. There are no SCLK
rate restrictions for this command. However, subsequent data retrieval SCLKs or the SDATAC opcode
command should wait at least 4 tCLK cycles for the command to execute. RDATAC timing is shown in Figure 38.
As Figure 38 shows, there is a keep out zone of 4 tCLK cycles around the DRDY pulse where this command
cannot be issued in. If no data are retrieved from the device, DOUT and DRDY behave similarly in this mode. To
retrieve data from the device after the RDATAC command is issued, make sure either the START pin is high or
the START command is issued. Figure 38 shows the recommended way to use the RDATAC command.
RDATAC is ideally-suited for applications such as data loggers or recorders where registers are set once and do
not need to be reconfigured.
START
DRDY
(1)
t UPDATE
CS
SCLK
RDATAC Opcode
DIN
Hi-Z
DOUT
Status Register + n-Channel Data
Next Data
(1) tUPDATE = 4 / fCLK. Do not read data during this time.
Figure 38. RDATAC Usage
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
31
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
SDATAC: Stop Read Data Continuous
This opcode cancels the Read Data Continuous mode. There are no SCLK rate restrictions for this command,
but the following command must wait for 4 tCLK cycles to execute.
RDATA: Read Data
Issue this command after DRDY goes low to read the conversion result (in Stop Read Data Continuous mode).
There are no SCLK rate restrictions for this command, and there is no wait time needed for subsequent
commands or data retrieval SCLKs. To retrieve data from the device after the RDATA command is issued, make
sure either the START pin is high or the START command is issued. When reading data with the RDATA
command, the read operation can overlap the next DRDY occurrence without data corruption. Figure 39 shows
the recommended way to use the RDATA command. RDATA is best suited for systems where register settings
must be read or changed often between conversion cycles.
START
DRDY
CS
SCLK
RDATA Opcode
DIN
RDATA Opcode
Hi-Z
DOUT
Status Register + n-Channel Data (216 Bits)
Figure 39. RDATA Usage
Sending Multibyte Commands
The ADS131E0x serial interface decodes commands in bytes and requires 4 tCLK cycles to decode and execute.
Therefore, when sending multibyte commands, a 4-tCLK period must separate the end of one byte (or opcode)
and the next.
Assuming SCLK is 2.048 MHz, then tSDECODE (4 tCLK) is 1.96 µs. When SCLK is 16 MHz, one byte can be
transferred in 500 ns. This byte transfer time does not meet the tSDECODE specification; therefore, a delay must be
inserted so the end of the second byte arrives 1.46 µs later. If SCLK is 4 MHz, one byte is transferred in 2 µs.
Because this transfer time exceeds the tSDECODE specification, the processor can send subsequent bytes without
delay. In this later scenario, the serial port can be programmed to move from single-byte transfers per cycle to
multiple bytes.
32
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
RREG: Read From Register
This opcode reads register data. The Register Read command is a two-byte opcode followed by the register data
output. The first byte contains the command opcode and the register address. The second opcode byte specifies
the number of registers to read – 1.
First opcode byte: 001r rrrr, where r rrrr is the starting register address.
Second opcode byte: 000n nnnn, where n nnnn is the number of registers to read – 1.
The 17th SCLK rising edge of the operation clocks out the MSB of the first register, as shown in Figure 40. When
the device is in read data continuous mode, an SDATAC command must be issued before the RREG command
can be issued. The RREG command can be issued at any time. However, because this command is a multibyte
command, there are SCLK rate restrictions depending on how the SCLKs are issued. See the Serial Clock
(SCLK) subsection of the SPI Interface section for more details. Note that CS must be low for the entire
command.
CS
1
9
17
25
SCLK
DIN
OPCODE 1
OPCODE 2
REG DATA
DOUT
REG DATA + 1
Figure 40. RREG Command Example: Read Two Registers Starting from Register 00h (ID Register)
(OPCODE 1 = 0010 0000, OPCODE 2 = 0000 0001)
WREG: Write to Register
This opcode writes register data. The Register Write command is a two-byte opcode followed by the register data
input. The first byte contains the command opcode and the register address.
The second opcode byte specifies the number of registers to write – 1.
First opcode byte: 010r rrrr, where r rrrr is the starting register address.
Second opcode byte: 000n nnnn, where n nnnn is the number of registers to write – 1.
After the opcode bytes, the register data follows (in MSB-first format), as shown in Figure 41. The WREG
command can be issued at any time. However, because this command is a multibyte command, there are SCLK
rate restrictions depending on how the SCLKs are issued. See the Serial Clock (SCLK) subsection of the SPI
Interface section for more details. Note that CS must be low for the entire command.
CS
1
9
17
25
SCLK
DIN
OPCODE 1
OPCODE 2
REG DATA 1
REG DATA 2
DOUT
Figure 41. WREG Command Example: Write Two Registers Starting from 00h (ID Register)
(OPCODE 1 = 0100 0000, OPCODE 2 = 0000 0001)
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
33
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
REGISTER MAP
Table 10 describes the various ADS131E0x registers.
Table 10. Register Assignments (1)
ADDRESS
RESET
VALUE
(Hex)
REGISTER
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
xx
REV_ID2
REV_ID1
REV_ID0
1
0
0
NU_CH2
NU_CH1
Device Settings (Read-Only Registers)
00h
ID
Global Settings Across Channels
01h
CONFIG1
91
1
DAISY_IN
CLK_EN
1
0
DR2
DR1
DR0
02h
CONFIG2
E0
1
1
1
INT_TEST
0
TEST_AMP0
TEST_FREQ1
TEST_FREQ0
03h
CONFIG3
40
PDB_REFBUF
1
VREF_4V
0
OPAMP_REF
PDB_OPAMP
0
0
04h
FAULT
00
COMP_TH2
COMP_TH1
COMP_TH0
0
0
0
0
0
Channel-Specific Settings
05h
CH1SET
10
PD1
GAIN12
GAIN11
GAIN10
0
MUX12
MUX11
MUX10
06h
CH2SET
10
PD2
GAIN22
GAIN21
GAIN20
0
MUX22
MUX21
MUX20
07h
CH3SET
10
PD3
GAIN32
GAIN31
GAIN30
0
MUX32
MUX31
MUX30
08h
CH4SET
10
PD4
GAIN42
GAIN41
GAIN40
0
MUX42
MUX41
MUX40
09h
CH5SET
10
PD5
GAIN52
GAIN51
GAIN50
0
MUX52
MUX51
MUX50
0Ah
CH6SET
10
PD6
GAIN62
GAIN61
GAIN60
0
MUX62
MUX61
MUX60
0Bh
CH7SET
10
PD7
GAIN72
GAIN71
GAIN70
0
MUX72
MUX71
MUX70
0Ch
CH8SET
10
PD8
GAIN82
GAIN81
GAIN80
0
MUX82
MUX81
MUX80
Fault Detect Status Registers (Read-Only Registers)
12h
FAULT_STATP
00
IN8P_FAULT
IN7P_FAULT
IN6P_FAULT
IN5P_FAULT
IN4P_FAULT
IN3P_FAULT
IN2P_FAULT
IN1P_FAULT
13h
FAULT_STATN
00
IN8N_FAULT
IN7N_FAULT
IN6N_FAULT
IN5N_FAULT
IN4N_FAULT
IN3N_FAULT
IN2N_FAULT
IN1N_FAULT
0F
GPIOD4
GPIOD3
GPIOD2
GPIOD1
GPIOC4
GPIOC3
GPIOC2
GPIOC1
GPIO and Other Registers
14h
(1)
GPIO
Registers 0Dh, 0Eh, 0Fh, 10h, and 11h must be written to all 0's.
User Register Description
ID: ID Control Register (Factory-Programmed, Read-Only)
Address = 00h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REV_ID2
REV_ID1
REV_ID0
1
0
0
NU_CH2
NU_CH1
This register is programmed during device manufacture to indicate device characteristics.
Bits[7:5]
REV_ID[2:0]: Device family identification
These bits indicate the device family.
000, 001, 010, 011, 100, 101 = Reserved
110 = ADS131E08
111 = Reserved
Bit 4
Must be set to '1'
This bit reads high.
Bits[3:2]
Must be set to '0'
These bits read low.
Bits[1:0]
NU_CH[2:1]: Factory-programmed device identification bits (read-only)
These bits indicate the device version.
00
01
10
11
34
= 4-channel device
= 6-channel device
= 8-channel device
= Reserved
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
CONFIG1: Configuration Register 1
Address = 01h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
1
DAISY_IN
CLK_EN
1
0
DR2
DR1
DR0
This register configures each ADC channel sample rate.
Bit 7
Must be set to '1'
Bit 6
DAISY_IN: Daisy-chain and multiple read-back mode
This bit determines which mode is enabled.
0 = Daisy-chain mode (default)
1 = Multiple read-back mode
Bit 5
CLK_EN: CLK connection (1)
This bit determines if the internal oscillator signal is connected to the CLK pin when the CLKSEL pin = 1.
0 = Oscillator clock output disabled (default)
1 = Oscillator clock output enabled
Bit 4
Must be set to '1'
Bit 3
Must be set to '0'
Bits[2:0]
DR[2:0]: Output data rate
These bits determine the output data rate and resolution. See Table 11 for details.
Modulator clock fMOD = fCLK / 2. Where fMOD = 1.024 MHz.
(1)
Additional power is consumed when driving external devices.
Table 11. Data Rate Settings
DR{2:0]
RESOLUTION
000
16-bit output
64
001
16-bit output
32 (default)
010
24-bit output
16
011
24-bit output
8
100
24-bit output
4
101
24-bit output
2
110
24-bit output
1
111
Do not use
NA
Copyright © 2012, Texas Instruments Incorporated
DATA RATE (kSPS)
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
35
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
CONFIG2: Configuration Register 2
Address = 02h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
1
1
1
INT_TEST
0
TEST_AMP0
TEST_FREQ1
TEST_FREQ0
This register configures the test signal generation. See the Input Multiplexer section for more details.
Bits[7:5]
Must be set to '1'
Bit 4
INT_TEST: Test source
This bit determines the source for the Test signal.
0 = Test signals are driven externally (default)
1 = Test signals are generated internally
Bit 3
Must be set to '0'
Bit 2
TEST_AMP: Test signal amplitude
These bits determine the Calibration signal amplitude.
0 = 1 × –(VREFP – VREFN) / 2.4 mV (default)
1 = 2 × –(VREFP – VREFN) / 2.4 mV
Bits[1:0]
TEST_FREQ[1:0]: Test signal frequency
These bits determine the calibration signal frequency.
00
01
10
11
36
= Pulsed at fCLK / 221 (default)
= Pulsed at fCLK / 220
= Not used
= At dc
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
CONFIG3: Configuration Register 3
Address = 03h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PDB_REFBUF
1
VREF_4V
0
OPAMP_REF
PDB_OPAMP
0
0
This register configures the multireference operation.
Bit 7
PDB_REFBUF: Power-down reference buffer
This bit determines the power-down reference buffer state.
0 = Power-down internal reference buffer (default)
1 = Enable internal reference buffer
Bit 6
Must be set to '1'
Default is '1' at power-up.
Bit 5
VREF_4V: Reference voltage
This bit determines the reference voltage, VREFP.
0 = VREFP is set to 2.4 V (default)
1 = VREFP is set to 4 V (use only with a 5-V analog supply)
Bit 4
Must be set to '0'
Bit 3
OPAMP_REF: Op amp reference
This bit determines whether the op amp noninverting input connects to the OPAMPP pin or to the internally-derived 1/2
supply (AVDD + AVSS) / 2.
0 = Noninverting input connected to the OPAMPP pin (default)
1 = Noninverting input connected to (AVDD + AVSS) / 2
Bit 2
PDB_OPAMP: Op amp power down
This bit determines the power-down reference buffer state.
0 = Power-down op amp (default)
1 = Enable op amp
Bits[1:0]
Must be set to '0'
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
37
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
FAULT: Fault Detect Control Register
Address = 04h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
COMP_TH2
COMP_TH1
COMP_TH0
0
0
0
0
0
This register configures the fault detection operation.
Bits[7:5]
COMP_TH[2:0]: Fault detect comparator threshold
These bits determine the fault detect comparator threshold level setting. See the Fault Detection section for a detailed
description.
Comparator high-side threshold
000 = 95% (default)
001 = 92.5%
010 = 90%
011 = 87.5%
100 = 85%
101 = 80%
110 = 75%
111 = 70%
Comparator low-side threshold
000 = 5% (default)
001 = 7.5%
010 = 10%
011 = 12.5%
100 = 15%
101 = 20%
110 = 25%
111 = 30%
Bits[4:0]
38
Must be set to '0'
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
CHnSET: Individual Channel Settings (n = 1 to 8)
Address = 05h to 0Ch
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PDn
GAINn2
GAINn1
GAINn0
0
MUXn2
MUXn1
MUXn0
This register configures the power mode, PGA gain, and multiplexer settings channels. See the Input Multiplexer
section for details. CH[2:8]SET are similar to CH1SET, corresponding to the respective channels (refer to
Table 10).
Bit 7
PDn: Power-down (n = individual channel number)
This bit determines the channel power mode for the corresponding channel.
0 = Normal operation (default)
1 = Channel power-down
Bits[6:4]
GAINn[2:0]: PGA gain (n = individual channel number)
These bits determine the PGA gain setting.
000 = Do not use
001 = 1 (default)
010 = 2
011 = Do not use
100 = 4
101 = 8
110 = 12
111 = Do not use
Bit 3
Must be set to '0'
Bits[2:0]
MUXn[2:0]: Channel input (n = individual channel number)
These bits determine the channel input selection.
000 = Normal input (default)
001 = Input shorted (for offset or noise measurements)
010 = Do not use
011 = MVDD for supply measurement
100 = Temperature sensor
101 = Test signal
110 = Do not use
111 = Do not use
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
39
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
FAULT_STATP: Fault Detect Positive Input Status
Address = 12h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
IN8P_FAULT
IN7P_FAULT
IN6P_FAULT
IN5P_FAULT
IN4P_FAULT
IN3P_FAULT
IN2P_FAULT
IN1P_FAULT
This register stores the status of whether the positive input on each channel has a fault or not. See the Fault
Detection section for details. Ignore the FAULT_STATP values if the corresponding FAULT_SENSP bits are not
set to '1'.
FAULT_STATN: Fault Detect Negative Input Status
Address = 13h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
IN8N_FAULT
IN7N_FAULT
IN6N_FAULT
IN5N_FAULT
IN4N_FAULT
IN3N_FAULT
IN2N_FAULT
IN1N_FAULT
This register stores the status of whether the negative input on each channel has a fault or not. See the Fault
Detection section for details. Ignore the FAULT_STATN values if the corresponding FAULT_SENSN bits are not
set to '1'.
GPIO: General-Purpose IO Register
Address = 14h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
GPIOD4
GPIOD3
GPIOD2
GPIOD1
GPIOC4
GPIOC3
GPIOC2
GPIOC1
This register controls the action of the three GPIO pins.
Bits[7:4]
GPIOD[4:1]: GPIO data
These bits are used to read and write data to the GPIO ports.
When reading the register, the data returned correspond to the state of the GPIO external pins, whether they are
programmed as inputs or outputs. As outputs, a write to the GPIOD sets the output value. As inputs, a write to the GPIOD
has no effect.
Bits[1:0]
GPIOC[4:1]: GPIO control (corresponding to GPIOD)
These bits determine if the corresponding GPIOD pin is an input or output.
0 = Output
1 = Input (default)
40
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
POWER MONITORING SPECIFIC APPLICATIONS
All channels of the ADS131E0x family of devices are exactly identical, yet independently configurable, thus
giving the user the flexibility of selecting any channel for voltage or current monitoring. An overview of this
system is illustrated in Figure 42. Also, the simultaneously sampling capability of the device allows the user to
monitor both the current and the voltage at the same time. The full-scale differential input voltage of each
channel is determined by the PGA gain setting (see the CHnSET: Individual Channel Settings section) for the
respective channel and VREF (see the CONFIG3: Configuration Register 3 section). Table 12 summarizes the fullscale differential input voltage range for an internal VREF.
Table 12. Full-Scale Differential Input Voltage Summary
VREF
2.4 V
4.0 V
PGA GAIN
FULL-SCALE DIFFERENTIAL INPUT
VOLTAGE, FSDI (VPP)
RMS VOLTAGE [= FSDI / (2√2)] (VRMS)
1
4.8
1.698
2
2.4
0.849
4
1.2
0.424
8
0.6
0.212
12
0.4
0.141
1
8
2.828
2
4
1.414
4
2
0.707
8
1
0.354
12
0.66
0.236
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
41
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
Neutral
Phase C
Phase B
Phase A
+1.5 V
+1.8 V
AVDD
DVDD
INP1
A
N
INN1
INP2
INN2
B
INP3
INN3
N
INP4
Device
INN4
INP5
C
INN5
N
INP6
INN6
INN8
INN7
INP8
INP7
AVSS
1.5 V
Figure 42. Overview of Power Monitoring System
42
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
CURRENT SENSING
Figure 43 shows a simplified diagram of typical configurations used for current sensing with a Rogowski coil,
current transformer (CT), or an air coil that outputs a current or voltage. In the case of the current output
transformers, the burden resistors (R1) are used for current-to-voltage conversion. The output of the burden
resistors is connected to the ADS131E0x INP and INN inputs through an antialiasing RC filter for current
sensing. In the case of the voltage output transformers (such as certain types of Rogowski coils), the output
terminals of the transformers are directly connected to the ADS131E0x INP and INN inputs through an
antialiasing RC filter for current sensing. The common-mode bias voltage (AVDD + AVSS) / 2, can be obtained
from the ADS131E0x by either configuring the internal op amp in a unity-gain configuration using the RF resistor
and setting bit 3 of the CONFIG3 register, or it can be generated externally with a simple resistor divider network
between the positive and negative supplies.
The value of resistor R1 for the current output transformer and turns ratio of the transformer should be selected
so as not to exceed the ADS131E0x full-scale differential input voltage (FSDI) range. Likewise, the output
voltage (V) for the voltage output transformer should be selected to not exceed the FSDI. In addition, the
selection of resistor (R) and turns ratio should not saturate the transformer over the full operating dynamic range
of the energy meter. Figure 43a shows differential input current sensing and Figure 43b shows single-ended
input sensing.
Device
N
Device
L
N
I
R2
L
R2
INP
R1
EMI
Filter
C
To PGA
V
INP
EMI
Filter
C
To PGA
R1
R2
I
INN
INN
OPAMPOUT
Rf
OPAMPN
OPAMPP
OPAMP_REF (AVDD + AVSS)
OPAMPOUT
2
Rf
+
+
OPAMP_REF (AVDD + AVSS)
2
OPAMPN
OPAMPP
(a) Current Output CT with Differential Input
(b) Voltage Output CT with Single-Ended Input
Figure 43. Simplified Current Sensing Connections
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
43
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
VOLTAGE SENSING
Figure 44 shows a simplified diagram of commonly-used differential and single-ended methods of voltage
sensing. A resistor divider network is used to step down the line voltage within the acceptable ADS131E0x input
range and then directly connect to the inputs (INP and INN) through an antialiasing RC filter formed by resistor
R3 and capacitor C. The common-mode bias voltage (AVDD + AVSS) / 2, can be obtained from the ADS131E0x
by either configuring the internal op amp in a unity-gain configuration using the RF resistor and setting bit 3 of the
CONFIG3 register, or it can be generated externally by using a simple resistor divider network between the
positive and negative supplies.
In either of the below cases (Figure 44a for a differential input and Figure 44b for a single-ended input), the line
voltage is divided down by a factor of [R2 / (R1 + R2)]. Values of R1 and R2 must be carefully chosen so that the
voltage across the ADS131E0x inputs (INP and INN) does not exceed the FSDI range of ADS131E0x (see
Table 12) over the full operating dynamic range of the energy meter.
Device
N
Device
L
N
R1
R3
R1
INP
R2
EMI
Filter
C
R2
R1
R3
L
To PGA
R3
R2
INP
EMI
Filter
C
INN
INN
OPAMPOUT
OPAMPN
OPAMP_REF (AVDD + AVSS)
OPAMPOUT
2
+
+
OPAMP_REF (AVDD + AVSS)
RF
To PGA
2
-
RF
OPAMPN
OPAMPP
OPAMPP
(a) Voltage Sensing with Differential Input
(b) Voltage Sensing with Single-Ended Input
Figure 44. Simplified Voltage Sensing Connections
44
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
FAULT DETECTION
The ADS131E0x have integrated comparators that can be used in conjunction with the external pull-up or pulldown resistors (R) to detect various fault conditions. The basic principle is to compare the input voltage with the
one set by the fault comparator 3-bit digital-to-analog converter (DAC), as shown in Figure 45. The comparator
trigger threshold level is set by the COMP_TH[2:0] bits in the FAULT register. Assuming that the ADS131E0x is
powered from ±2.5-V supply and COMP_TH[2:0] = 000 (95% and 5%), the high-side trigger threshold is set at
+2.25 V [equal to AVSS + (AVDD + AVSS) × 95%] and the low-side threshold is set at –2.25 V [equal to AVSS +
(AVDD + AVSS) × 5%]. The threshold calculation formula applies to unipolar as well as bipolar supplies.
A fault condition, such as an input signal going out of a predetermined range, can be detected by setting the
appropriate threshold level using the COMP_TH[2:0] bits. An open-circuit fault at the INP or INN pin can be
detected by using the external pull-up and pull-down resistors, which rail the corresponding input when the input
circuit breaks, causing the fault comparators to trip. To pinpoint which of the inputs is out of range, the status of
the FAULT_STATP and FAULT_STATN registers can be read, which is available as part of the output data
stream; see the Data Output (DOUT) subsection of the SPI Interface section.
3-Bit
DAC(1)
COMP_TH[2:0]
Fault Detect
Control Register
AVDD
FAULT_STATP
R
Voltage
Or
Current
Sensing
+
INP
EMI
Filter
INN
To
ADC
PGA
-
R
FAULT_STATN
AVSS
Device
(1) The configurable 3-bit DAC is common to all channels.
Figure 45. Fault Detect Comparators
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
45
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
QUICK-START GUIDE
PCB LAYOUT
Power Supplies and Grounding
The ADS131E0x have three supplies: AVDD, AVDD1, and DVDD. Both AVDD and AVDD1 should be as quiet as
possible. AVDD1 provides the supply to the charge pump block and has transients at fCLK. Therefore, it is
recommended that AVDD1 and AVSS1 be star-connected to AVDD and AVSS. It is important to eliminate noise
from AVDD and AVDD1 that is non-synchronous with device operation. Each ADS131E0x supply should be
bypassed with 10-μF and a 0.1-μF solid ceramic capacitors. It is recommended to place the digital circuits [such
as digital signal processors (DSPs), microcontrollers, and field-programmable gate arrays (FPGAs)] in the
system such that the return currents on those devices do not cross the ADS131E0x analog return path. The
ADS131E0x can be powered from unipolar or bipolar supplies.
The decoupling capacitors can be surface-mount, low-cost, low-profile multi-layer ceramic. In most cases the
VCAP1 capacitor can also be a multilayer ceramic. However, in systems where the board is subjected to high- or
low-frequency vibration, it is recommend that a non-ferroelectric capacitor (such as a tantalum or class 1
capacitor, C0G or NPO for example) be installed. EIA class 2 and class 3 dielectrics (such as X7R, X5R, and
X8R) are ferroelectric. The piezoelectric property of these capacitors can appear as electrical noise coming from
the capacitor. When using the internal reference, noise on the VCAP1 node results in performance degradation.
Connecting the Device to Unipolar (+3 V or +1.8 V) Supplies
Figure 46 illustrates the ADS131E0x connected to a unipolar supply. In this example, the analog supply (AVDD)
is referenced to analog ground (AVSS) and the digital supplies (DVDD) are referenced to digital ground (DGND).
+3 V
+1.8 V
0.1 µF
1 µF
1 µF
0.1 µF
AVDD AVDD1 DVDD
VREFP
VREFN
0.1 µF
10 µF
VCAP1
RESV1
VCAP2
Device
VCAP3
VCAP4
AVSS1 AVSS
DGND
1 µF
1 µF
0.1 µF
1 µF
22 µF
NOTE: Place the supply, reference, and VCAP1 to VCAP4 capacitors as close to the package as possible.
Figure 46. Single-Supply Operation
46
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
Connecting the Device to Bipolar (±1.5 V or 1.8 V) Supplies
Figure 47 illustrates the ADS131E0x connected to a bipolar supply. In this example, the analog supplies connect
to the device analog supply (AVDD). This supply is referenced to the device analog return (AVSS), and the
digital supply (DVDD) is referenced to the device digital ground return (DGND).
+1.5 V
+1.8 V
1 µF
0.1 µF
0.1 µF
1 µF
AVDD AVDD1 DVDD
VREFP
VREFN
0.1 µF
10 µF
1.5 V
VCAP1
Device
VCAP2
RESV1
VCAP3
VCAP4
AVSS1 AVSS
DGND
1 µF
1 µF
1 µF
0.1 µF
1 µF
22 µF
0.1 µF
1.5 V
NOTE: Place the capacitors for supply, reference, and VCAP1 to VCAP4 as close to the package as possible.
Figure 47. Bipolar Supply Operation
Shielding Analog Signal Paths
As with any precision circuit, careful PCB layout ensures the best performance. It is essential to make short,
direct interconnections and avoid stray wiring capacitance—particularly at the analog input pins and AVSS.
These analog input pins are high-impedance and extremely sensitive to extraneous noise. The AVSS pin should
be treated as a sensitive analog signal and connected directly to the supply ground with proper shielding.
Leakage currents between the PCB traces can exceed the ADS131E0x input bias current if shielding is not
implemented. Digital signals should be kept as far as possible from the analog input signals on the PCB.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
47
ADS131E04
ADS131E06
ADS131E08
SBAS561 – JUNE 2012
www.ti.com
POWER-UP SEQUENCING
Before device power-up, all digital and analog inputs must be low. At power-up, these signals should remain low
until the power supplies have stabilized, as shown in Figure 48. Once the supply voltages have reached the final
value, the digital power-on reset (tPOR) executes to set the digital portion of the chip. The reset pin, or reset
command, should be issued after tPOR and when the VCAP1 voltage is greater than 800 mV. The VCAP1 pin
charge time is set by RC time constant; see Figure 27. If the VCAP1 capacitor is 22 µF, a reset can be issued
within 400 ms after power up. After releasing RESET, the configuration register must be programmed (see the
CONFIG1: Configuration Register 1 subsection of the Register Map section for details). The power-up sequence
timing is shown in Table 13.
tPOR
Power Supplies
tRST
RESET
Start Using the Device
18 tCLK
Figure 48. Power-Up Timing Diagram
Table 13. Power-Up Sequence Timing
SYMBOL
DESCRIPTION
MIN
tPOR
Wait after power-up until reset
216
TYP
MAX
UNIT
tCLK
tRST
Reset low width
1
tCLK
SETTING THE DEVICE FOR BASIC DATA CAPTURE
This section outlines the procedure to configure the device in a basic state and capture data. This procedure is
intended to put the device in a data sheet condition to check if the device is working properly in the user system.
It is recommended that this procedure be followed initially to get familiar with the device settings. When this
procedure is verified, the device can be configured as needed. For details on the timings for commands refer to
the appropriate sections in the data sheet. The flow chart of Figure 49 details the initial ADS131E0x configuration
and setup.
48
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
ADS131E04
ADS131E06
ADS131E08
www.ti.com
SBAS561 – JUNE 2012
Analog or Digital
Set CLKSEL Pin = 0
and Provide External Clock
f = 2.048 MHz
YES
// Follow Power-Up Sequencing
External
Set CLKSEL Pin = 1,
Wait for Internal
Oscillator to Start Up
// If START is tied high, after this step
// DRDY toggles at fCLK / 64
NO
Set PWDN = 1
Set RESET = 1
Wait for 1 s
Issue Reset Pulse,
Wait for 18 tCLKs
Set PDB_REFBUF = 1
and Wait for Internal
Reference
NO
// Delay for Power-On Reset and Oscillator Start-Up
// Activate DUT
// CS can be Either Tied Permanently Low
// Or Selectively Pulled Low Before Sending
// Commands or Reading and Sending Data from or to the Device
Send SDATAC
Command
// Device Wakes Up in RDATAC Mode, so Send
// SDATAC Command so Registers can be Written
SDATAC
External
Reference
// If Using Internal Reference, Send This Command
WREG CONFIG3 C0h
YES
Write Certain
Registers,
Including Input
// Set Device for DR = fMOD / 32
WREG CONFIG1 91h
WREG CONFIG2 E0h
// Set All Channels to Input Short
WREG CHnSET 01h
Set START = 1
// Activate Conversion
// After This Point DRDY Should Toggle at
// fCLK / 64
RDATAC
// Put the Device Back in RDATAC Mode
RDATAC
Capture Data
and Check Noise
// Look for DRDY and Issue 24 + n u 24 SCLKs
Set Test Signals
// Activate a (1 mV / 2.4 V) Square-Wave Test Signal
// On All Channels
SDATAC
WREG CONFIG2 F0h
WREG CHnSET 05h
RDATAC
Capture Data
and Test Signal
// Look for DRDY and Issue 24 + n u 24 SCLKs
Figure 49. Initial Flow at Power-Up
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): ADS131E04 ADS131E06 ADS131E08
49
PACKAGE OPTION ADDENDUM
www.ti.com
17-Jul-2012
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package
Drawing
Pins
Package Qty
Eco Plan
(2)
Lead/
Ball Finish
MSL Peak Temp
(3)
(Requires Login)
ADS131E04IPAG
ACTIVE
TQFP
PAG
64
160
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-3-260C-168 HR
ADS131E04IPAGR
ACTIVE
TQFP
PAG
64
1500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-3-260C-168 HR
ADS131E06IPAG
ACTIVE
TQFP
PAG
64
160
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-3-260C-168 HR
ADS131E06IPAGR
ACTIVE
TQFP
PAG
64
1500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-3-260C-168 HR
ADS131E08IPAG
ACTIVE
TQFP
PAG
64
160
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-3-260C-168 HR
ADS131E08IPAGR
ACTIVE
TQFP
PAG
64
1500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-3-260C-168 HR
COMBOSMARTMETER
ACTIVE
0
TBD
Call TI
Samples
Call TI
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
17-Jul-2012
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
14-Jul-2012
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
ADS131E04IPAGR
TQFP
PAG
64
1500
330.0
24.4
13.0
13.0
1.5
16.0
24.0
Q2
ADS131E06IPAGR
TQFP
PAG
64
1500
330.0
24.4
13.0
13.0
1.5
16.0
24.0
Q2
ADS131E08IPAGR
TQFP
PAG
64
1500
330.0
24.4
13.0
13.0
1.5
16.0
24.0
Q2
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
14-Jul-2012
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
ADS131E04IPAGR
TQFP
PAG
64
1500
367.0
367.0
45.0
ADS131E06IPAGR
TQFP
PAG
64
1500
367.0
367.0
45.0
ADS131E08IPAGR
TQFP
PAG
64
1500
367.0
367.0
45.0
Pack Materials-Page 2
MECHANICAL DATA
MTQF006A – JANUARY 1995 – REVISED DECEMBER 1996
PAG (S-PQFP-G64)
PLASTIC QUAD FLATPACK
0,27
0,17
0,50
48
0,08 M
33
49
32
64
17
0,13 NOM
1
16
7,50 TYP
Gage Plane
10,20
SQ
9,80
12,20
SQ
11,80
0,25
0,05 MIN
1,05
0,95
0°– 7°
0,75
0,45
Seating Plane
0,08
1,20 MAX
4040282 / C 11/96
NOTES: A. All linear dimensions are in millimeters.
B. This drawing is subject to change without notice.
C. Falls within JEDEC MS-026
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46C and to discontinue any product or service per JESD48B. Buyers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All
semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time
of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Mobile Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated