Series 1 - 110/125A 120/240, 480 Vac • AC Output • Zero Voltage and Random Turn-On Switching • Panel Mount • Internal Snubber A24110 D24110 A24125 D24125 HA48110 HD48110 HA48125 HD48125 24-280 24-280 48-530 48-530 Max. Load Current ➂ [Arms] 110 125 110 125 Min. Load Current, [mArms] 150 150 150 150 Transient Overvoltage [Vpk] 600 600 1200 1200 1500 1750 1500 1750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (RθJC) [˚C/W] .25 .22 .25 .22 9,340 12,700 9,340 12,700 10 10 10 10 500 500 500 500 MODEL NUMBERS AC CONTROL D C C ONTROL Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9002 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Surge Current, (16.6ms) [Apk] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ Max. Turn-On Time ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec (AC Control) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ 0.5 0.5 0.5 DC CONTROL AC CONTROL AC CONTROL (D PREFIX) (A PREFIX) (E SUFFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms Nominal Input Impedance 1500 Ohms (120/240V Models) ➄ 60K Ohms 9.0K Ohms Typical Input Current 3.4mA @ 5 Vdc, 20mA @ 28Vdc➄ 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms GENERAL NOTES ©1998 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25ºC unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). ➄ Input circuitry for 480V models incorporates active current limiter with 2mA typical input current.. FastFax Document No. 152 110/125.040898, PAGE 1 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany 9002 Series 1 - 110/125A 120/240, 480 Vac • AC Output GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted AVAILABLE OPTIONS E 24 Vac Input (18-36 Vac) Example: A24110E -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: D24110-10 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 8-32 TERMINAL (2 PLACES ) OUTPUT 1 1.87 (47.5) 2 SOLID-STATE RELAY -- + 4 Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. 2.30 (58.4) 1.70 (43.2) 3 INPUT 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) All dimensions are in inches (millimeters) .78 (19.8) .90 (22.9) 6-32 TERMINAL (2 PLACES) CURRENT DERATING CURVES 110A 125A 160 120 .5ºC/W 100 80 1ºC/W 110 40 90 .4ºC/W Power Dissipation Power Dissipation .2ºC/W Base Plate Temp [ºC] 90 .4ºC/W 120 .5ºC/W .2ºC/W 100 80 1ºC/W 110 40 120 0 Base Plate Temp [ºC] 160 120 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [ºC] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [ºC] ©1998 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116950 FastFax Document No. 152 110/125.040898, PAGE 2 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany 9002