Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: • AC-DC Constant Current or Constant Voltage LED Driver • Input range 90-305VAC/47-440Hz • High Efficiency up to 89% • Operating temperature -40 to 85°C • Dimmable via analog / 0-10V dimming ② Models Single output Model Output Voltage ③ Range (V) AMEPR60-50120AZ AMEPR60-36170AZ AMEPR60-24250AZ Output Current ③ (A) Input Voltage (VAC/Hz) Input Voltage (VDC) 90-305/47-440 120-430 36-50 0-1.27 24-36 0-1.77 90-305/47-440 120-430 12-24 0-2.55 90-305/47-440 120-430 5-12 0-5.2 90-305/47-440 AMEPR60-12500AZ 120-430 • • • • • Over Temperature Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Mode of Operation Constant Current Constant Voltage ② Constant Current Constant Voltage ② Constant Current Constant Voltage ② Constant Current Constant Voltage ② Max Output Power (W) ① Efficiency (%) 60 89 63.8 86 59.8 88 63.7 86 60 87 61 85 60 85 62 82 Exceeding the maximum output power will permanently damage the converter The dimming feature is not supported when units are used in Constant Voltage mode only. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. ① ② Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor External fuse Start up time Surge voltage Output Specifications Parameters Current accuracy (CC Mode) Voltage accuracy (CV Mode) Line regulation Load regulation Ripple & Noise ④ www.aimtec.com F 052.1e R3.R Conditions Typical 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 30 50 0.5 0.7 0.73 0.33 250 2sec Conditions Typical ±3 ±3 ±1 ±3 75 LL-HL 0-100% load 20MHz Bandwidth Tel: +1 514 620 2722 1 of 12 Maximum Units A mA A 0.97 0.93 250V/1.5A 440 ms V Maximum Units % % % % mV p-p Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Output Specifications (continued) Parameters Conditions Typical Maximum Units Conditions Typical Rated Units Hold-up time 90 Current adjustment range 100-0 Minimum Load Voltage See the models table ④ Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end. Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Isolation Capacitance 3 sec/3.5mA 500VDC General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF >1000 1000 Conditions ms % 3000 VAC MΩ pF Typical Maximum 130 95-110% of Iout 110% of Vout Continuous Auto recovery >105°C -40 to +85 With derating over 55°C Units KHz o 100 -40 to +95 ±0.02 Free air convection Plastic Epoxy (IP67 rated) UL1015 18AWG *20CM 350 5.30 x 2.27 x 1.59 inches 134.80 x 57.68 x 40.50 mm >400,000 hrs (MIL-HDBK-217F at +25°C) 95 C C o C % / oC o % RH g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.R cULus, CE UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Surge Immunity IEC 61000-4-5 RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimensions End View 40.50 (1.59) Top View 16.75 (0.66) 137.33 (5.41) 60.00 (2.36) 32.00 60.00 (1.26) (2.36) Side View 200.00 (8.00) 200.00 (8.00) 40.50 (1.59) Input/Output Wires are 18 AWG 20cm 2.30 (0.09) 161.30 (6.35) Analog (resistive) Dimming Application Circuit AC BROWN L GREEN +Vout AMEPR60-AZ BLUE N F 052.1e R3.R 1 1st LED -Vout 1 BLUE WHITE www.aimtec.com Model Number RED AMEPR60-50120AZ AMEPR60-36170AZ AMEPR60-24250AZ AMEPR60-12500AZ Maximum Pot Value (kΩ) 26.00 16.95 26.10 34.10 BLACK Pot Tel: +1 514 620 2722 3 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter 0-10V Dimming Application Circuit U1 +Vs (Blue) 0-10Vdc Pin 1 -Vs (White) Pin 2 R28 1K5, 0805 LTV-817C GND Temperature Graph Free Air Convection 55 º C Output Power % 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 4 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency Vs. Input Voltage & Output Current (Constant Current Mode) AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 5 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency Vs. Input Voltage & Output Current (Constant Current Mode) Continued AMEPR60-24250AZ AMEPR60-12500AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 6 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter PFC Value vs. Output Load Current (Constant Current Mode) AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 7 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter PFC Value vs. Output Load Current (Constant Current Mode) Continued AMEPR60-24250AZ AMEPR60-12500AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 8 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current vs. Constant Voltage Mode AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 9 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current vs. Constant Voltage Mode Continued AMEPR60-24250AZ AMEPR60-12500AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 10 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimming Control (Output Current vs. Radj) AMEPR60-50120AZ AMEPR60-36170AZ www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 11 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimming Control (Output Current vs. Radj) Continued AMEPR60-24250AZ AMEPR60-12500AZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 12 of 12 Toll free: + 1 888 9 AIMTEC (924 6832) North America only