Merrimac ARC-1 Variable attenuators, manual Datasheet

ARC Series
VARIABLE ATTENUATORS, MANUAL
DC to 400 MHz / 0 to 20 dB Range / Broadband / Panel Mountable / 50
& 75
/ BNC & SMA
PRINCIPAL SPECIFICATIONS
Frequency Performance Attenuation Flatness,
Model Range,
Band,
Range,
Pk-Pk,
Number
MHz
MHz
dB, Min. dB, Typ.
Insertion
Loss,
VSWR,
dB, Max. Max.
Impedance,
Nom.
ARC-1
DC - 400
DC - 50
DC - 200
DC - 400
0 - 20
0 - 13
0-8
(See
Graph
Below)
1.0
1.5
2.5
1.5:1
1.8:1
2.2:1
50 Ω
ARC-2
DC - 400
DC - 50
DC - 200
DC - 400
0 - 20
0 - 13
0-8
(See
Graph
Below)
1.0
1.5
2.5
1.5:1
1.8:1
2.2:1
50 Ω
ARC-3
DC - 400
DC - 50
DC - 200
DC - 400
0 - 20
0 - 13
0- 8
(See
Graph
Below)
1.0
1.5
2.5
1.5:1
1.8:1
2.2:1
50 Ω
ARC-4
DC - 400
DC - 50
DC - 200
DC - 400
0 - 20
0 - 13
0- 8
(See
Graph
Below)
1.0
1.5
2.5
1.5:1
1.8:1
2.2:1
50 Ω
Typical Performance
Mechanical
Configuration
& Connector
Panel-Screw Drive/SMA
Panel-Screw Drive/SMA
w/Knob
Panel-Screw Drive/BNC
Panel-Screw Drive/BNC
w/Knob
GENERAL SPECIFICATIONS
Resetability (Granularity):
Average Power:
Weight, nominal:
Operating Temperature:
0.2 dB typ.
0.5 Watts max.
2 oz. (56 g)
-- 55° to +85°C
General Notes:
1. The ARC series consists of continuously variable
attenuators utilizing compensated Bridged Tee
Networks to vary signal power. These constant
impedance, very broadband attenuators are designed
to cover frequencies from DC to 400 MHz. Similar units
are available with electronic control of attenuation in the
ARE and ARES series.
2. All Merrimac Attenuators are designed for high
reliability in accordance with applicable paragraphs of
MIL-A-24215 and can be supplied screened to meet
specific military and space applications.
28Jun02
For further information contact MERRIMAC / 41 Fairfield Pl., West Caldwell, NJ, 07006 / 973-575-1300 / FAX 973-575-0531
ARC Series
VARIABLE ATTENUATORS, MANUAL
DC to 400 MHz / 0 to 20 dB Range / Broadband / Panel Mountable / 50
& 75
/ BNC & SMA
ARC-1 (& ARC-3) Package Outline
NOTES:
1. Tolerance on 3 place decimals ±0.020(.51) except as noted.
2. Dimensions in inches over millimeters.
3. ARC-3 as ARC-1 but with BNC connectors
ARC-2 (& ARC-4, ARC-7) Package Outlines
NOTES:
1. Tolerance on 3 place decimals ±0.020 (0.51) except as noted.
2. Dimensions in inches over millimeters.
3. Knob is shipped to customer loose.
4. Secure knob with (2) #4 screws supplied with knob.
5. ARC-4 and ARC-7 as ARC-2 but with BNC connectors.
26Feb96
ForfurtherinformationcontactM ERRIM AC /41 Fairfield Pl.,W estCaldw ell,NJ,07006 / 973-575-1300 /FAX 973-575-0531