Delta DNL10S0A0S16PFD Non-isolated point of load dc/dc power modules: 8.3-14vin, 0.75-5.0v/20a out Datasheet

FEATURES
High efficiency: 92% @ 12Vin, 3.3V/20A out
Š
Small size and low profile: (SMD)
Š
33.0x 13.5x 8.8mm (1.30” x 0.53” x 0.35”)
Š
Standard footprint
Š
Voltage and resistor-based trim
Š
Pre-bias startup
Š
Output voltage tracking
Š
No minimum load required
Output voltage programmable from
Š
0.75Vdc to 5.0Vdc via external resistor
Š
Fixed frequency operation (300KHz)
Š
Input UVLO, output OTP, OCP
Š
Remote ON/OFF
Š
Remote sense
Š
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS 18001 certified manufacturing
facility
UL/cUL 60950-1 (US & Canada), and TUV
Š
(EN60950-1) - pending
Delphi DNL10, Non-Isolated Point of Load
DC/DC Power Modules: 8.3-14Vin, 0.75-5.0V/20A out
OPTIONS
The Delphi series DNL10, 8.3~14V input, single output, 20A non-isolated
point of load DC/DC converter in surface mounted package is the latest
offering from a world leader in power systems technology and
manufacturing ― Delta Electronics, Inc. The DNL10 series provides a
programmable output voltage from 0.75V to 5.0V through an external
trimming resistor. The DNL10 converters have flexible and programmable
tracking and sequencing features to enable a variety of sequencing and
tracking between several point of load power modules. This product
family is available in a surface mount or SIP package and provides up to
APPLICATIONS
20A of output current in an industry standard footprint and pinout. With
Š
Telecom / DataCom
creative design technology and optimization of component placement,
Š
Distributed power architectures
Š
Servers and workstations
Š
LAN / WAN applications
Š
Data processing applications
these converters possess outstanding electrical and thermal performance
and extremely high reliability under highly stressful operating conditions.
PRELIMINARY DATASHEET
DS_DNL10SMD20_07182012
TECHNICAL SPECIFICATIONS
TA = 25°C, airflow rate = 300 LFM, Vin = 8.3Vdc and 14Vdc, nominal Vout unless otherwise noted.
PARAMETER
NOTES and CONDITIONS
DNL10S0A0S20 (Standard)
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Tracking Voltage
Operating Temperature
Storage Temperature
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Maximum Input Current
No-Load Input Current
Off Converter Input Current
Inrush Transient
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Adjustable Range
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Output Current Range
Output Voltage Over-shoot at Start-up
Output DC Current-Limit Inception
Output Short-Circuit Current (Hiccup mode)
DYNAMIC CHARACTERISTICS
Dynamic Load Response
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time to 10% of Peak Deviation
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Output Voltage Rise Time
Output Capacitive Load
EFFICIENCY
Vo=0.75V
Vo=1.0V
Vo=1.2V
Vo=1.5V
Vo=1.8V
Vo=2.0V
Vo=2.5V
Vo=3.3V
Vo=5.0V
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, (Negative logic)
Logic Low Voltage
Logic High Voltage
Logic Low Current
Logic High Current
ON/OFF Control, (Positive Logic)
Logic High Voltage
Logic Low Voltage
Logic High Current
Logic Low Current
Tracking Slew Rate Capability
Tracking Delay Time
Tracking Accuracy
Remote Sense Range
GENERAL SPECIFICATIONS
MTBF
Weight
Over-Temperature Shutdown
DS_DNL10SMD_07182012
Typ.
0
0
-40
-55
Vo,set≦3.63Vdc
Vo,set>3.63Vdc
8.3
8.3
12
12
Max.
Units
15
Vin,max
85
+125
Vdc
Vdc
°C
°C
14
13.2
7.9
7.8
Vin=Vin,min to Vin,max, Io=Io,max
0.4
15
V
V
A
mA
mA
A2S
A
+2.0
5
% Vo,set
V
+3.5
% Vo,set
% Vo,set
% Vo,set
% Vo,set
14
100
2
Vin= Vin,min to Vin,max, Io=Io,min to Io,max
Vin=12V, Io=Io,max
Vin=Vin,min to Vin,max
Io=Io,min to Io,max
Ta= -40℃ to 85℃
Over sample load, line and temperature
5Hz to 20MHz bandwidth
Vin=min to max, Io=min to max.1µF ceramic, 100uF ceramic.
Vin=min to max, Io=min to max.1µF ceramic, 100uF ceramic.
-2.0
0.7525
Vo,set
0.3
0.4
0.4
-2.5
35
10
150
3
mV
mV
A
% Vo,set
% Io
Adc
150
150
60
mVpk
mVpk
µs
0
Vout=3.3V
Io,s/c
470uF poscap & 100µF+1uF ceramic load cap, 5A/µs,
50% Io, max to 100% Io, max
100% Io, max to 50% Io, max
Io=Io.max
Von/off, Vo=10% of Vo,set
Vin=Vin,min, Vo=10% of Vo,set
Time for Vo to rise from 10% to 90% of Vo,set
Full load; ESR ≧1mΩ
Full load; ESR ≧10mΩ, Vin<9.0V
Full load; ESR ≧10mΩ, Vin≧9.0V
5
5
4
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Vin=12V, Io=Io,max
Module On, Von/off
Module Off, Von/off
Module On, Ion/off
Module Off, Ion/off
Module On, Von/off
Module Off, Von/off
Module On, Ion/off
Module Off, Ion/off
Delay from Vin.min to application of tracking voltage
Power-up, subject to 2V/mS
Power-down, subject to 1V/mS
Io=80%Io, max, Ta=25℃
Refer to Figure 39 for the measuring point
V
V
75
20
20
1
6
1000
3500
5000
ms
ms
ms
µF
µF
µF
78
82
84
86
88
89
90
92
94
%
300
kHz
-0.2
2.5
0.2
-0.2
0.2
0.1
10
100
200
TBD
9
130
%
%
%
%
%
%
0.3
Vin,max
10
1
V
V
uA
mA
Vin,max
0.3
10
1
2
V
V
uA
mA
V/ms
ms
mV
mV
V
200
400
0.1
M hours
grams
°C
2
90
95
85
90
EFFICIENCY(%)
EFFICIENCY(%)
ELECTRICAL CHARACTERISTICS CURVES
80
75
Vin=8.3V
70
Vin=12V
65
Vin=14V
60
80
Vin=8.3V
75
Vin=12V
70
Vin=14V
65
2
4
6
8
10
12
LOAD (A)
14
16
18
20
2
4
6
8
12
14
16
18
20
Figure 2: Converter efficiency vs. output current
(1.2V output voltage)
(0.75V output voltage)
100
90
95
EFFICIENCY(%)
95
85
80
Vin=8.3V
75
Vin=12V
70
Vin=14V
90
85
Vin=8.3V
Vin=12V
80
Vin=14V
65
75
2
4
6
8
10
12
14
16
18
20
2
4
6
8
LOAD (A)
10
12
14
16
18
20
LOAD (A)
Figure 3: Converter efficiency vs. output current
(1.8V output voltage)
Figure 4: Converter efficiency vs. output current
(2.5V output voltage)
100
100
95
EFFICIENCY(%)
EFFICIENCY(%
10
LOAD (A)
Figure 1: Converter efficiency vs. output current
EFFICIENCY(%)
85
90
85
V in=8.3V
V in=12V
80
95
90
Vin=8.3V
Vin=12V
85
Vin=14V
V in=14V
75
2
4
6
8
10
12
14
16
LOA D (A )
Figure 5: Converter efficiency vs. output current
(3.3V output voltage)
DS_DNL10SMD_07182012
18
20
80
2
4
6
8
10
12
14
16
18
20
LOAD (A)
Figure 6: Converter efficiency vs. output current
(5.0V output voltage)
3
ELECTRICAL CHARACTERISTICS CURVES
Figure 7: Output ripple & noise at 12Vin,
0.7525V/20A out
Figure 8: Output ripple & noise at 12Vin,
1.2V/20A out
Figure 9: Output ripple & noise at 12Vin,
2.5V/20A out
Figure 10: Output ripple & noise at 12Vin,
5.0V/20A out
Vin
Remote On/Off
Vo
Vo
Figure 11: Turn on delay from 12vin, 5.0V/20A out
DS_DNL10SMD_07182012
Figure 12: Turn on delay by Remote On/Off,
5.0V/20A out
4
Vin
Vo
Figure 13: Turn on at 12Vin, with external capacitors
(Co= 5000 µF), 5.0V/20A out
Remote On/Off
Vo
Figure 14: Turn on Using Remote On/Off with external
capacitors (Co= 5000 µF), 5.0V/16A out
Figure 15: Typical transient response to step load
change at 5A/µS from 50% to 100% of Io,
max at 12Vin, 0.75V out (Cout = 1uF+
100uF ceramic, 470uF poscap).
Figure 16: Typical transient response to step load
change at 5A/µS from 100% to 50% of Io,
max at 12Vin, 0.75V out (Cout = 1uF+
100uF ceramic, 470uF poscap).
Figure 17: Typical transient response to step load
change at 5A/µS from 50% to 100% of Io,
max at 12Vin, 1.2V out (Cout = 1uF+ 100uF
ceramic, 470uF poscap).
Figure 18: Typical transient response to step load
change at 5A/µS from 100% to 50% of Io,
max at 12Vin, 1.2V out (Cout = 1uF+
100uF ceramic, 470uF poscap).
DS_DNL10SMD_07182012
5
Figure 19: Typical transient response to step load
change at 5A/µS from 50% to 100% of Io,
max at 12Vin, 2.5V out (Cout = 1uF+ 100uF
ceramic, 470uF poscap).
Figure 20: Typical transient response to step load
change at 5A/µS from 100% to 50% of Io,
max at 12Vin, 2.5V out (Cout = 1uF+ 100uF
ceramic, 470uF poscap).
Figure 21: Typical transient response to step load change
at 5A/µS from 50% to 100% of Io, max at 12Vin, 5.0V out
(Cout = 1uF+ 100uF ceramic, 470uF poscap).
Figure 22: Typical transient response to step load
change at 5A/µS from 100% to 50% of Io,
max at 12Vin, 5.0V out (Cout = 1uF+ 100uF
ceramic, 470uF poscap).
Remote On/Off
Vo
Figure 23: Output short circuit current 12Vin, 0.75Vout
(10A/div)
DS_DNL10SMD_07182012
Figure 24: Turn on with Prebias 12Vin, 5V/0A out,
Vbias =3.3Vdc
6
DESIGN CONSIDERATIONS
TEST CONFIGURATIONS
Input Source Impedance
TO OSCILLOSCOPE
L
VI(+)
4 × 47uF
BATTERY
ceramic
VI(-)
Note: Input reflected-ripple current is measured with a
simulated source inductance. Current is
measured at the input of the module.
To maintain low-noise and ripple at the input voltage, it is
critical to use low ESR capacitors at the input to the
module. The models using 4x47 uF very low ESR
ceramic
capacitors
(MURATA
P/N:
GRM32ER61C476ME15L, 47uF/16V or equivalent) for
example.
The input capacitance should be able to handle an AC
ripple current of at least:
Irms = Iout
Figure 25: Input reflected-ripple test setup
Vout 
Vout 

1 −
Vin 
Vin 
Arms
CO PPER STRIP
Vo
1uF
100uF
SCOPE
ceramic ceram ic
Resistive
Load
GND
Input Ripple Voltage (mVp-p)
450
400
350
300
250
200
150
100
Ceramic
50
0
0
1
2
3
4
5
6
Output Voltage (Vdc)
Note: Use a 100µF and 1µF ceramic capacitor. Scope
measurement should be made using a BNC
connector.
Figure 28: Input ripple voltage vs. output models, Io = 20A
(Cin = 4x22uF ceramic capacitors at the input)
Figure 26: Peak-peak output noise and startup transient
measurement test setup
CONTACT AND
DISTRIBUTION LOSSES
VI
Vo
Io
I
LOAD
SUPPLY
GND
CONTACT RESISTANCE
Figure 27: Output voltage and efficiency measurement test
setup
Note: All measurements are taken at the module
terminals. When the module is not soldered (via
socket), place Kelvin connections at module
terminals to avoid measurement errors due to
contact resistance.
η =(
Vo × Io
) × 100 %
Vi × Ii
DS_DNL10SMD_07182012
7
DESIGN CONSIDERATIONS (CON.)
FEATURES DESCRIPTIONS
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the module. An
input capacitance must be placed close to the modules
input pins to filter ripple current and ensure module
stability in the presence of inductive traces that supply
the input voltage to the module.
Remote On/Off
Safety Considerations
For safety-agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power module
has extra-low voltage (ELV) outputs when all inputs are
ELV.
The input to these units is to be provided with a
maximum 15A of glass type fast-acting fuse in the
ungrounded lead.
The DNL series power modules have an On/Off pin for
remote On/Off operation. Both positive and negative
On/Off logic options are available in the DNL series
power modules.
For positive logic module, connect an open collector
(NPN) transistor or open drain (N channel) MOSFET
between the On/Off pin and the GND pin (see figure 32).
Positive logic On/Off signal turns the module ON during
the logic high and turns the module OFF during the logic
low. When the positive On/Off function is not used, leave
the pin floating or tie to Vin (module will be On).
For negative logic module, the On/Off pin is pulled high
with an external pull-up resistor (see figure 33) Negative
logic On/Off signal turns the module OFF during logic
high and turns the module ON during logic low. If the
negative On/Off function is not used, leave the pin
floating or tie to GND. (module will be On)
Vo
Vin
ION/OFF
RL
On/Off
GND
Figure 29: Positive remote On/Off implementation
Vo
Vin
Rpull-up
ION/OFF
On/Off
RL
GND
Figure 30: Negative remote On/Off implementation
Over-Current Protection
To provide protection in an output over load fault
condition, the unit is equipped with internal over-current
protection. When the over-current protection is
triggered, the unit enters hiccup mode. The units
operate normally once the fault condition is removed.
DS_DNL10SMD_07182012
8
FEATURES DESCRIPTIONS (CON.)
Over-Temperature Protection
The over-temperature protection consists of circuitry
that provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold
the module will shut down. The module will try to restart
after shutdown. If the over-temperature condition still
exists during restart, the module will shut down again.
This restart trial will continue until the temperature is
within specification
Remote Sense
The DNL provide Vo remote sensing to achieve proper
regulation at the load points and reduce effects of
distribution losses on output line. In the event of an
open remote sense line, the module shall maintain local
sense regulation through an internal resistor. The
module shall correct for a total of 0.1V of loss. The
remote sense line impedance shall be < 10Ω.
Distribution Losses
Distribution Losses
Vin
Vo
For example, to program the output voltage of the DNL
module to 3.3Vdc, Rtrim is calculated as follows:
 10500 − 1000  ⋅ Ω
 2.5475

Rtrim := 
Rtrim = 3.122 kΩ
DNL can also be programmed by applying a voltage
between the TRIM and GND pins (Figure 36). The
following equation can be used to determine the value of
Vtrim needed for a desired output voltage Vo:
Vtrim := 0.7 − ( Vo − 0.7525) ⋅ 0.0667
Vtrim is the external voltage in V
Vo is the desired output voltage
For example, to program the output voltage of a DNL
module to 3.3 Vdc, Vtrim is calculated as follows
Vtrim := 0.7 − ( 2.5475⋅ 0.0667)
Vtrim = 0.530V
Sense
RL
GND
Distribution Losses
Distribution Losses
Figure 31: Effective circuit configuration for remote sense
operation
Output Voltage Programming
The output voltage of the DNL can be programmed to
any voltage between 0.75Vdc and 5.0Vdc by
connecting one resistor (shown as Rtrim in Figure 35)
between the TRIM and GND pins of the module.
Without this external resistor, the output voltage of the
module is 0.7525 Vdc. To calculate the value of the
resistor Rtrim for a particular output voltage Vo, please
use the following equation:
 10500 − 1000  ⋅ Ω
 Vo − 0.7525

Figure 32: Circuit configuration for programming output voltage
using an external resistor
Rtrim := 
Rtrim is the external resistor in Ω
Vo is the desired output voltage
DS_DNL10SMD_07182012
Figure 33: Circuit Configuration for programming output voltage
using external voltage source
9
FEATURE DESCRIPTIONS (CON.)
Table 1 provides Rtrim values required for some common
output voltages, while Table 2 provides values of external
voltage source, Vtrim, for the same common output
voltages. By using a 1% tolerance trim resistor, set point
tolerance of ±2% can be achieved as specified in the
electrical specification.
Table 1
VO (V)
0.7525
1.0
1.2
1.5
1.8
2.0
2.5
3.3
5.0
Rtrim (KΩ)
Open
41.424
22.464
13.047
9.024
7.416
5.009
3.122
1.472
Table 2
VO (V)
0.7525
1.0
1.2
1.5
1.8
2.0
2.5
3.3
5.0
Vtrim (V)
Open
0.6835
0.670
0.650
0.630
0.6168
0.583
0.530
0.4167
The amount of power delivered by the module is the
voltage at the output terminals multiplied by the output
current. When using the trim feature, the output voltage
of the module can be increased, which at the same
output current would increase the power output of the
module. Care should be taken to ensure that the
maximum output power of the module must not exceed
the maximum rated power (Vo.set x Io.max ≤ P max).
Voltage Margining
Output voltage margining can be implemented in the DNL
modules by connecting a resistor, R margin-up, from the Trim
pin to the ground pin for margining-up the output voltage
and by connecting a resistor, Rmargin-down, from the Trim pin
to the output pin for margining-down. Figure 37 shows
the circuit configuration for output voltage margining. If
unused, leave the trim pin unconnected. A calculation
tool is available from the evaluation procedure, which
computes the values of Rmargin-up and Rmargin-down for a
specific output voltage and margin percentage.
Vin
Vo
Rmargin-down
Q1
On/Off
Trim
Rmargin-up
Rtrim
Q2
GND
Figure 34: Circuit configuration for output voltage margining
Voltage Tracking
The DNL family was designed for applications that have
output voltage tracking requirements during power-up
and power-down. The devices have a TRACK pin to
implement three types of tracking method: sequential
start-up, simultaneous and ratio-metric. TRACK simplifies
the task of supply voltage tracking in a power system by
enabling modules to track each other, or any external
voltage, during power-up and power-down.
By connecting multiple modules together, customers can
get multiple modules to track their output voltages to the
voltage applied on the TRACK pin.
DS_DNL10SMD_07182012
10
FEATURE DESCRIPTIONS (CON.)
The output voltage tracking feature (Figure 35 to Figure
37) is achieved according to the different external
connections. If the tracking feature is not used, the
TRACK pin of the module can be left unconnected or tied
to Vin.
For proper voltage tracking, input voltage of the tracking
power module must be applied in advance, and the
remote on/off pin has to be in turn-on status. (Negative
logic: Tied to GND or unconnected. Positive logic: Tied to
Vin or unconnected)
PS1
PS1
PS2
PS2
Sequential Start-up
Sequential start-up (Figure 35) is implemented by placing
an On/Off control circuit between VoPS1 and the On/Off pin
of PS2.
PS2
PS1
Vin
Vin
VoPS1
VoPS2
R3
On/Off
R1
Q1
On/Off
R2
C1
Simultaneous
Simultaneous tracking (Figure 36) is implemented by
using the TRACK pin. The objective is to minimize the
voltage difference between the power supply outputs
during power up and down.
Figure 35: Sequential start-up
PS1
PS1
PS2
PS2
The simultaneous tracking can be accomplished by
connecting VoPS1 to the TRACK pin of PS2. Please note
the voltage apply to TRACK pin needs to always higher
than the VoPS2 set point voltage.
PS2
PS1
Vin
Vin
VoPS1
TRACK
Figure 36: Simultaneous
On/Off
+△V
VoPS2
PS1
PS1
PS2
PS2
On/Off
Figure 37: Ratio-metric
DS_DNL10SMD_07182012
11
FEATURE DESCRIPTIONS (CON.)
Ratio-Metric
Ratio–metric (Figure 37) is implemented by placing the
voltage divider on the TRACK pin that comprises R1 and
R2, to create a proportional voltage with VoPS1 to the
Track pin of PS2.
For Ratio-Metric applications that need the outputs of
PS1 and PS2 reach the regulation set point at the same
time
The following equation can be used to calculate the value
of R1 and R2.
The suggested value of R2 is 10kΩ.
Vo, PS 2
Vo, PS1
=
R2
R1 + R2
PS2
PS1
Vin
Vin
VoPS1
VoPS2
R1
TRACK
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The height of this fan duct is constantly kept
at 25.4mm (1’’).
R2
On/Off
On/Off
Thermal Derating
The high for positive logic
The low for negative logic
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power
module should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
PWB
FANCING PWB
MODULE
50.8(2.00")
AIR VELOCITY
AND AMBIENT
TEMPERATURE
SURED BELOW
THE MODULE
AIR F LOW
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 38: Wind tunnel test setup
DS_DNL10SMD_07182012
12
THERMAL CURVES
DNL10S0A0S20 series Output Current vs. Ambient Temperature and Air Velocity
@ Vin =12V, Vout =1.8V (Worse orientation)
25
Output Current (A)
20
15
Natural
Convection
10
100LFM
300LFM
200LFM
400LFM
5
0
25
Figure 39: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 125℃.
45
55
65
75
85
Ambient Temperature (℃)
Figure 42: DNL10S0A0S20(Standard) Output current vs.
ambient temperature and air velocity @ Vin=12V, Vo=1.8V(Either
Orientation)
DNL10S0A0S20 series Output Current vs. Ambient Temperature and Air Velocity
@ Vin =12V, Vout =5V (Worse orientation)
25
35
DNL10S0A0S20 series Output Current vs. Ambient Temperature and Air Velocity
@ Vin =12V, Vout =0.75V (Worse orientation)
Output Current (A)
25
Output Current (A)
20
20
Natural
Convection
15
15
400LFM
100LFM
10
Natural
Convection
200LFM
100LFM
300LFM
10
200LFM
500LFM
300LFM
600LFM
5
5
0
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 40: DNL10S0A0S20 (Standard) Output current vs.
ambient temperature and air velocity @ Vin=12V,
Vo=5.0V(Either Orientation)
0
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 43: DNL10S0A0S20 (Standard) Output current vs.
ambient temperature and air velocity @ Vin=12V,
Vo=0.75V(Either Orientation)
DNL10S0A0S20 series Output Current vs. Ambient Temperature and Air Velocity
@ Vin =12V, Vout =3.3V (Worse orientation)
25
Output Current (A)
20
15
10
Natural
Convection
300LFM
100LFM
400LFM
200LFM
500LFM
5
0
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 41: DNL10S0A0S20 (Standard)Output current vs.
ambient temperature and air velocity @ Vin=12V, Vo=3.3V(Either
Orientation)
DS_DNL10SMD_07182012
13
PICK AND PLACE LOCATION
SURFACE-MOUNT TAPE & REEL
LEADED (Sn/Pb) PROCESS RECOMMEND TEMPERATURE PROFILE
Temperature (°C )
250
200
150
Ramp-up temp.
0.5~3.0°C /sec.
2nd Ramp-up temp. Peak temp.
210~230°C 5sec.
1.0~3.0°C /sec.
Pre-heat temp.
140~180°C 60~120 sec.
Cooling down rate <3°C /sec.
100
Over 200°C
40~50sec.
50
0
60
120
Time ( sec. )
180
240
300
Note: All temperature refers to assembly application board, measured on the land of assembly application board.
LEAD FREE (SAC) PROCESS RECOMMEND TEMPERATURE PROFILE
Temp.
Peak Temp. 240 ~ 245 ℃
220℃
Ramp down
max. 4℃ /sec.
200℃
150℃
Preheat time
90~120 sec.
Time Limited 75 sec.
above 220℃
Ramp up
max. 3℃ /sec.
25℃
Time
Note: All temperature refers to assembly application board, measured on the land of assembly application board.
DS_DNL10SMD_07182012
14
MECHANICAL DRAWING
SMD PACKAGE
DS_DNL10SMD_07182012
SIP PACKAGE (OPTIONAL)
15
PART NUMBERING SYSTEM
DNL
Product
Series
DNL - 16A
DNM -10A
10
0A0
S
20
N
Output
Voltage
Package
Type
Output
Current
On/Off
logic
0A0 Programmable
R - SIP
S - SMD
20 - 20A
16 -16A
N- Negative
(Default)
10 -10A
06 - 6A
P- positive
S
Numbers of
Input Voltage
Outputs
04 - 2.8~5.5V
10 - 8.3~14V
S - Single
DNS - 6A
F
D
Option Code
F- RoHS 6/6
(Lead Free)
D - Standard Functions
MODEL LIST
Model Name
Packaging
Input
Voltage
Output Voltage
DNL10S0A0S20NFD
SMD
8.3 ~ 14Vdc
0.75 V~ 5.0Vdc
Efficiency
Output Current On/Off logic 12Vin @ 100% load
20A
Negative
92.0%
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107 ext 6220
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta
for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license
is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these
specifications at any time, without notice.
DS_DNL10SMD_07182012