Diodes BAT40VC Surface mount schottky barrier diode array Datasheet

BAT40VC
SURFACE MOUNT SCHOTTKY BARRIER DIODE ARRAYS
Features
Mechanical Data
•
•
•
•
•
•
•
•
•
Low Forward Voltage Drop
Fast Switching
Ultra-Small Surface Mount Package
PN Junction Guard Ring for Transient and ESD Protection
Lead Free by Design/RoHS Compliant (Note 1)
"Green" Device (Note 2)
Qualified to AEC-Q101 Standards for High Reliability
•
•
•
•
Case: SOT-563
Case Material: Molded Plastic, "Green" Molding Compound. UL
Flammability Classification Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminal Connections: See Diagram
Terminals: Finish – Matte Tin annealed over Copper
leadframe. Solderable per MIL-STD-202, Method 208
Weight: 0.003 grams (approximate)
Bottom View
Top View
C1
NC
C2
A1
NC
A2
Device Schematic
Ordering Information (Note 3)
Part Number
BAT40VC-7
Notes:
Case
SOT-563
Packaging
3000/Tape & Reel
1. No purposefully added lead.
2. Diodes Inc's "Green" policy can be found on our website at http://www.diodes.com.
3. For packaging details, go to our website at http://www.diodes.com.
Marking Information
AXK YM
Date Code Key
Year
2004
AXK = Product Type Marking Code
YM = Date Code Marking
Y = Year (ex: R = 2004)
M = Month (ex: 9 = September)
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
Code
R
S
T
U
V
W
X
Y
Z
A
B
C
Month
Code
Jan
1
Feb
2
Mar
3
Apr
4
May
5
Jun
6
Jul
7
Aug
8
Sep
9
Oct
O
Nov
N
Dec
D
BAT40VC
Document number: DS30637 Rev. 6 - 2
1 of 4
www.diodes.com
October 2010
© Diodes Incorporated
BAT40VC
Maximum Ratings @TA = 25°C unless otherwise specified
Characteristic
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
Symbol
VRRM
VRWM
VR
IF
IFRM
IFSM
Forward Continuous Current (Note 4)
Repetitive Peak Forward Current (Note 4)
Forward Surge Current (Note 4) @tp =10ms
Value
Unit
40
V
200
350
750
mA
mA
mA
Thermal Characteristics
Characteristic
Power Dissipation (Note 4)
Thermal Resistance, Junction to Ambient Air (Note 4)
Operating and Storage Temperature Range
Electrical Characteristics
Value
150
833
-65 to +125
Symbol
V(BR)R
VF
Min
40
Typ
⎯
Max
⎯
Unit
V
⎯
⎯
330
420
800
1000
mV
Reverse Leakage Current (Note 5)
Total Capacitance
IR
CT
⎯
⎯
⎯
⎯
500
10
nA
pF
Reverse Recovery Time
trr
⎯
⎯
5.0
ns
Notes:
Unit
mW
°C/W
°C
@TA = 25°C unless otherwise specified
Characteristic
Reverse Breakdown Voltage (Note 5)
Forward Voltage
Symbol
PD
RθJA
TJ, TSTG
Test Condition
IR = 100μA
IF = 2.0mA
IF = 15mA
IF = 100mA
IF = 200mA
VR = 25V
VR = 1.0V, f = 1.0MHz
IF = 10mA through IR = 10mA
to IR = 1.0mA, RL = 100Ω
4. Device mounted on FR-4 PCB, 1 inch x 0.85 inch x 0.062 inch; pad layout as shown on Diodes Inc. suggested pad layout document AP02001, which
can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. TA = 25°C.
5. Short duration pulse test used to minimize self-heating effect.
BAT40VC
Document number: DS30637 Rev. 6 - 2
2 of 4
www.diodes.com
October 2010
© Diodes Incorporated
1
IR, INSTANTANEOUS REVERSE CURRENT (µA)
IF, INSTANTANEOUS FORWARD CURRENT (A)
BAT40VC
0.1
0.01
0.001
0.0001
0.4
1.0
0.2
0.8
0
0.6
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Typical Forward Characteristics
100
10
1
0.1
0.01
0.001
0
250
12
10
PD, POWER DISSIPATION (mW)
CT, TOTAL CAPACITANCE (pF)
20
30
5
10
15
25
VR, INSTANTANEOUS REVERSE VOLTAGE (V)
Fig. 2 Typical Reverse Characteristics
8
6
4
2
200
150
0
0
100
50
0
-50
10
15
20
25
5
30
VR, DC REVERSE VOLTAGE (V)
Fig. 3 Total Capacitance vs. Reverse Voltage
100
0
50
TA, AMBIENT TEMPERATURE (°C)
Fig. 4 Derating Curve - Total
150
Package Outline Dimensions
A
B
C
D
G
M
K
SOT-563
Dim Min
Max
Typ
A
0.15 0.30 0.20
B
1.10 1.25 1.20
C
1.55 1.70 1.60
D
0.50
G
0.90 1.10 1.00
H
1.50 1.70 1.60
K
0.55 0.60 0.60
L
0.10 0.30 0.20
M
0.10 0.18 0.11
All Dimensions in mm
H
L
BAT40VC
Document number: DS30637 Rev. 6 - 2
3 of 4
www.diodes.com
October 2010
© Diodes Incorporated
BAT40VC
Suggested Pad Layout
E
Z
E
Dimensions Value (in mm)
Z
2.2
G
1.2
X
0.375
Y
0.5
C
1.7
E
0.5
C
G
Y
X
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2010, Diodes Incorporated
www.diodes.com
BAT40VC
Document number: DS30637 Rev. 6 - 2
4 of 4
www.diodes.com
October 2010
© Diodes Incorporated
Similar pages