ETC2 C211120006 Timers symmetrical recycler Datasheet

Timers
Symmetrical Recycler
Types C 101, C 201, C 108, C 208, C 111, C 211, C 118, C 218
• Time ranges: 0.15 s to 600 s
• Automatic start
• C .0.: Starts with OFF-time
C .1.: Starts with ON-time
• Knob-adjustable time within range
• Oscillator-controlled time circuit
• Repeatability deviation: ≤ 1%
• Output: 10 A SPDT or 8 A DPDT relay
• Plug-in type module
• Scantimer housing
• LED-indication for relay on
• AC or DC power supply
Product Description
Ordering Key
Mono-function, plug-in, symmetrical, ON/OFF miniature
recyclers up to 600 s (10 min)
covering 3 individual time
ranges. Optional ON- or OFF-
Function
Output
Type
Power supply
Time range
time period first. This economical relay is often used in
lighting systems such as advertising signs, etc.
C 108 024 600
Type Selection, OFF-Time Period First
Plug
Output
Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
8 pin
SPDT
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 108 024 006
C 108 024 060
C 108 024 600
C 108 120 006
C 108 120 060
C 108 120 600
C 108 220 006
C 108 220 060
C 108 220 600
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 101 024 006
C 101 024 060
C 101 024 600
C 101 120 006
C 101 120 060
C 101 120 600
C 101 220 006
C 101 220 060
C 101 220 600
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 208 024 006
C 208 024 060
C 208 024 600
C 208 120 006
C 208 120 060
C 208 120 600
C 208 220 006
C 208 220 060
C 208 220 600
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 201 024 006
C 201 024 060
C 201 024 600
C 201 120 006
C 201 120 060
C 201 120 600
C 201 220 006
C 201 220 060
C 201 220 600
Circular
11 pin
Circular
8 pin
DPDT
Circular
11 pin
Type Selection, ON-Time Period First
Plug
Output
Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
8 pin
SPDT
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 118 024 006
C 118 024 060
C 118 024 600
C 118 120 006
C 118 120 060
C 118 120 600
C 118 220 006
C 118 220 060
C 118 220 600
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 111 024 006
C 111 024 060
C 111 024 600
C 111 120 006
C 111 120 060
C 111 120 600
C 111 220 006
C 111 220 060
C 111 220 600
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 218 024 006
C 218 024 060
C 218 024 600
C 218 120 006
C 218 120 060
C 218 120 600
C 218 220 006
C 218 220 060
C 218 220 600
0.15- 6 s
1.5 - 60 s
15 - 600 s
C 211 024 006
C 211 024 060
C 211 024 600
C 211 120 006
C 211 120 060
C 211 120 600
C 211 220 006
C 211 220 060
C 211 220 600
Circular
11 pin
Circular
8 pin
Circular
11 pin
DPDT
Specifications are subject to change without notice (25.10.99)
1
C 108, C 208, C 118, C 218
C 101, C 201, C 111, C 211
Time Specifications
Time ranges
Time range accuracy
0.15- 6 s
1.5 - 60 s
15.0 - 600 s
0 to +10% on max.
min. actual time ≤ min.
set time
Repeatability deviation
Time variation
Within rated power supply
and ambient temperature
Reset
Time and/or relay
≤ 1%
≤ 0.05%/V
≤ 0.2%/°C
Power supply interruption min.
250 ms
Output Specifications
Output
Basic electrical insulation
Contact ratings (AgCdO)
Resistive loads
AC 1
DC 1
or
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
AC 1
Operating frequency
Insulation voltages
Rated insulation voltage
Rated transient protection volt.
C 108, C 101, C 118, C 111
C 208, C 201, C 218, C 211
SPDT relay
250 VAC (rms) (contact/electronics)
µ (micro gap)
10 A/250 VAC (2500 VA)
1 A/250 VDC (250 W)
10 A/25 VDC (250 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
≤ 7200 operations/h
DPDT relay
250 VAC (rms) (contacts/elec., contact/contact)
µ (micro gap)
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
≤ 7200 operations/h
≥ 2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
≥ 2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
Supply Specifications
General Specifications
Power supply AC types
Rated operational voltage
through pins 2 & 10
220
or pins 2 & 7
120
Installation cat. III (IEC 60664)
Indication for
Output ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Weight
Approvals
Rated insulation voltage
Rated transient protection volt.
Consumption
AC supply
DC supply
Power ON delay
Power OFF delay
None
800 V (1.2/50 µs)
60 mA @ 50 Hz/70 mA @ 60 Hz
1W
≤ 200 ms
≥ 250 ms
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
024
24 VAC + 15/- 20%,
45 to 65 Hz
Dropout tolerance
≥ 10 ms
Rated insulation voltage
None
Rated transient protection volt. 4 kV (1.2/50 µs) @ 220 VAC
2.5 kV (1.2/50 µs) @ 120 VAC
800 V (1.2/50 µs) @ 24 VAC
(line/neutral)
Power supply DC type
Installation cat. III (IEC 60664)
Rated operational volt. 024
24 VDC + 15/- 20% (pin 2 pos.)
2
LED. red
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
85 g
UL, CSA
Specifications are subject to change without notice (25.10.99)
C 108, C 208, C 118, C 218
C 101, C 201, C 111, C 211
Mode of Operation
Example 1
(Types C .0.)
OFF-time period first
The time period starts when
power supply is applied.
At the end of the first set time
period, the relay operates. At
the end of the second set
time period (equal to the first),
the relay releases.
This sequence is repeated until power supply is interrupted.
If power supply is disconnected, the time is reset and a recovery period of 250 ms should be allowed before the recycler is ready for reactivation.
Wiring Diagrams
Example 2
(Types C .1.)
ON-time period first
The relay operates and the
time period starts immediately
when power supply is applied.
At the end of the first set time
period, the relay releases. At
the end of the second set
time period (equal to the first),
the relay operates again.
Power supply
C 108, C 118
C 208, C 218
Power supply
C 101, C 111
C 201, C 211
This sequence is repeated
with equal intervals until power supply is interrupted. If
power supply is interrupted,
the time is reset and a recovery period of 250 ms should be
allowed before the recycler is
ready for reactivation.
Time Setting
Accessories
Knob-adjustable on scale in
seconds.
Sockets◊
Hold down spring◊
Mounting rack
Socket cover
Potentiometer lock
S 408, S 411
HF
SM 13
BB4
PL 1
For further information refer to "Accessories".
Operation Diagram
Power supply
Example 1: Relay on
Example 2: Relay on
Specifications are subject to change without notice (25.10.99)
3
Similar pages