Vicor CRCW20100000Z0EF Vi brickâ® ac front end evaluation board Datasheet

user Guide
VI BRICK® AC Front End
Evaluation Board
November 2012
Contents
Page
Features
1
Introduction
1
Set Up
3
Bill of Materials
5
Recommended
Hardware
6
Thermals
6
Ordering Info
6
Features
> Oscilloscope probe jack for output voltage and ripple measurements
> Simple to use
> Ring lug, screw terminal, and solder connection options
> Replaceable fuse (5A, 216 Littelfuse recommended)
IMPORTANT NOTICE:
Please read this user guide before operating evaluation board.
Introduction
The VI BRICK AC Front End Evaluation Board offers a convenient means to evaluate
the performance of Vicor’s VI BRICK AC Front End module and has been optimized
for user convenience. Refer to the table below for operating conditions and limits.
This product contains an input line filter. It is important to remember the response
of the AC line filter is dependent upon the wiring connected to the evaluation board.
Care should be exercised to minimize stray source impedances in order to fully
exercise the features of the converter.
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2
Page 1
Figure 1
VI BRICK AC Front End
Evaluation Board layout and
dimensional drawing,
component side.
(Click on drawing to view larger.)
Basic Specifications and Operating Limits
Please use the following table for operating limits:
Table 1
Operating Limits
Description
SpecificationNotes
Input Range
Output voltage
Output Power
Operating temperature
Output capacitance
85 – 264 Vac Universal input
48 Vdc Partially Regulated, SELV
330 W Over entire input range
-40 to 100 °C Case temperature
6,000 to 12,000μF 63V rating
Please refer to Figure 1 for locations of the input and output connections as viewed
from the component side. Wires may be soldered directly to the pads instead of ring
lugs if desired to minimize circuit impedances.
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2
Page 2
DANGER! HIGH VOLTAGE!
DANGER! HOT SURFACE!
The VI BRICK AC Front End Evaluation Board contains exposed hazardous voltages.
These voltages are within the area marked by the hashed line on the board.
The VI BRICK AC Front End Evaluation Board may be operated at surface
temperatures which may pose a thermal hazard to the operator. Because of the
thermal and voltage hazards, be careful not to touch any exposed surface unless the
power is disconnected and the evaluation board has been given sufficient time to cool.
The evaluation board is not intended for use in end item equipment.
Set Up
The Customer Evaluation Board should be set up as follows:
Note: Care should be taken to avoid reversing polarities if connecting to the opposite
(solder) side of the board.
AC Input Connections (J01)
DANGER! HIGH VOLTAGE!
J01, the screw terminal connector, is for connection of AC input to the AC-DC
converter evaluation board. The interconnect leads should be appropriate for the
current and voltage supplied to the board.
For single phase power, connect LINE to the pin marked L, NEUTRAL to the pin
marked N and earth ground to the pin marked EARTH. Corresponding wires in an IEC
cable are brown, blue, and yellow with a green stripe.
The board can be used with three phase power. Connect LINE1 to L and LINE2 to N.
Earth ground should still be connected to the EARTH terminal of J1.
+OUT, –OUT
There are several connections available on the VI BRICK AC Front End Evaluation
Board. Table 1 lists the available connectors and their current rating. Do not exceed
the rating of the connector or the module.
Table 2
Output Connector Ratings
Recommended
Connector
Rating
Connection
J02
10 A Hold-up capacitor
Mating PRM and BCM eval
J03
12 A (3 A/contact)
boards
Ring Lugs
100 A General Purpose
H03 (+OUT) & H07 (-OUT)
12 A Hold-up capacitor
Output bulk (electrolytic) capacitance must be attached across the output of the VI
BRICK AC Front End Evaluation Board. Refer to table 1 from previous page for the
appropriate range of output capacitance.
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2
Page 3
The load should be connected to +OUT and –OUT terminals of the evaluation board
with short leads of suitable gauge to carry the output current and minimize losses.
A sufficient number of terminal connections should be used to ensure that no
terminal sees more than its maximum rated current. The evaluation board can be
connected directly to the application for which the module is intended. However
the interconnect impedances between the evaluation board and the application
can greatly affect the transient response. For applications where transient response
is critical, the user should consider mounting the VI BRICK AC Front End module
directly to the target application PCB. Test points TP12 (–OUT) and TP07 (+OUT) can
be used to monitor the output and are located on the PCB adjacent to the output
terminals of the AC Front End module.
Earth Connections
There are several earth connections available on the board. Earth must be connected
via a low impedance connection in order for the internal line filter to function. These
earth connections also provide a safety ground for the baseplate of the module.
Earth may optionally be connected to either of the VI BRICK AC Front End outputs in
order to provide a positive or negative voltage rail with respect to earth.
Output Voltage Measurement Jack (J12)
This connector is provided to make accurate measurements of the output ripple
voltage of the VI BRICK AC Front End. Many types of scope probes may be directly
connected to this point if the probe is equipped with a removable plastic sheath.
To avoid creating ground loops when making measurements of the output or input
voltage, these measurements should be made separately.
Figure 2
VI BRICK AC Front End
Output capacitor (C29) can be
added to reduce switching frequency
voltage ripple at the probe.
(Click on drawing to view larger.)
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2
Page 4
Table 3
Bill of Materials
Ref.
Description
Desc.
Digi-Key
Digi-Key
Future
Future
Manufacturer
Part #
Manufacturer
Part #
CAP X7R 2200pF
Murata
490-3480-2-ND Murata
GA355QR7GF222KW01L
10% 250V 2220
CAPY X7R 4700pF
C12
Murata
490-3482-2-ND Murata
GA355DR7GF472KW01L
10% 250V 2220
C13
C29
C30
C31
NOT APPLIED
NOT APPLIED
NOT APPLIED
NOT APPLIED
NOT APPLIED
C32
C33
C34
C35
C01
C36
C37
C38
C39
F01
H03 &
H07
J01
J02
J03
J05
JP02
JP03
L01
L05
PS01
R01
R09
R10
Z01
CAP X7R .1uF
10% 25V 0805
CAP ALUM 100UF
63V 20% RADIAL
FUSE HOLDER,
SMD, 5x20
CAP ALEL 6800uF
Murata
490-1673-2-ND
Murata
Nichicon
UVY1J101MPD-ND Nichicon
UVY1J101MPD
Wickmann
F4546-ND
31.8225
Schurter
GRM21BR71E104KA01L
Kemet
493-1135-ND
Nichicon
UVZ1J682MRD
20% 63V 25X50
CON 3CKT TERM
No Stock
No Stock
Weco
140-A-126-SMD/03
BLK SMD
CON 2 CKT TERM
No Stock
No Stock
Weco
140-A-126-SMD/02
BLK SMD
CONN 10POS
Sullins
Sullins
90DEG THRUHOLE
S5519-ND
PPTC052LJBN-RC
Electronics
Electronics
FEMALE 0.1SPC
CONN 5POS
SINGLE ROW
Molex
WM1893-ND
TE Connectivity 1445057-5
RIGHT ANGLE
RES 0 OHM 3/4W
Vishay Dale
541-0.0WTR-ND Vishay Dale
CRCW20100000Z0EF
5% 2010
NOT APPLIED
NOT APPLIED
NOT APPLIED
NOT APPLIED
NOT APPLIED
IND 15.0uH
Stocked by Mouser, part#: MLF2012C150KT
10% 5mA 0805
IND COM MODE
Stocked by Vicor, part#: 37052-601
600uH 30% 10A
Model Specific
Vicor
Model Specific
Vicor
Model Specific
RES 6.81 OHM
Vishay Dale
541-6.81CCTRND Vishay Dale
CRCW08056R81FKEA
1/8W 1% 0805
RES 2.2 OHM
Vishay Dale
541-2.20FFTRND Vishay Dale
CRCW12062R20FKEA
1/4W 1% 1206
NOT APPLIED
NOT APPLIED
NOT APPLIED
NOT APPLIED
NOT APPLIED
VAR MOV, 300V TMOV20RP30
10KA 20mm
Littelfuse
Littelfuse
TMOV20RP300E
0EL2T7-ND
DIA RADIAL
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2
Page 5
Input Current Measurement
A current probe can be passed around either input lead connected to the VI BRICK AC
Front End Evaluation Board. Note that an input capacitor on the evaluation board is
downstream of this measurement point.
Enable (EN)
DANGER! HIGH VOLTAGE!
The EN pin can be used to disable the VI BRICK AC Front End module. Connecting EN
to the –IN-PFM pin will disable the module. This will also clear any latching output OVP
fault if one has occurred. Note that the EN pin is referenced to the primary (hazardous
voltage) side of the converter. Warning: The EN Pin, or the –IN PFM Pin must not be
connected to line or output of the VIBRICK AC Front End.
Efficiency Measurement
As the VI BRICK AC Front End module can deliver and consume large currents, the effect of the PCB must be considered when making an efficiency measurement. Be certain
to accurately measure the voltage using test points TP08 (LINE1) , TP14 (LINE2/NEUTRAL), TP18 (–OUT), and TP01 (+OUT). Using these test points will more closely represent the efficiency of the VI BRICK AC Front End module.
Hardware
The hardware kit provided with the evaluation board includes the following:
> (10) #10 internal tooth lock washers
> (10) #10-32 hex nuts
> (10) #10 external tooth lock washers
> (4) F-F standoffs
> (10) #10-32 screws
> (8) M3 x 5 mm screws
> (4) Rubber feet
Ring lugs are also recommended for making output connections.
Thermals
For most lab environments a fan blowing across the evaluation board is recommended.
See VI BRICK Thermal Management Application Note at:
vicorpower.com/documents/application_notes/AN_Vibrick%20%20thermManage.pdf
or contact Vicor Applications Engineering for assistance (800) 927-9474.
Ordering Information
The evaluation board is specified by replacing the “–00” suffix with “–CB” on the VI
BRICK AC Front End model number (FE175D480C033FP-CB).
The Power Behind Performance
12/2012
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2
Page 6
Similar pages