ON CAT5221WI00 Dual digitally programmable potentiometer (dppâ ¢) with 64 taps and i2c interface Datasheet

CAT5221
Dual Digitally Programmable Potentiometer (DPP™) with
64 Taps and I2C Interface
FEATURES
DESCRIPTION
„ Two linear-taper digitally programmable
potentiometers
„ 64 resistor taps per potentiometer
„ End to end resistance 2.5 kΩ, 10 kΩ, 50 kΩ or
100 kΩ
„ Potentiometer control and memory access via
I2C interface
„ Low wiper resistance, typically 80 Ω
„ Nonvolatile memory storage for up to four
wiper settings for each potentiometer
„ Automatic recall of saved wiper settings at
power up
„ 2.5 to 6.0 volt operation
„ Standby current less than 1µA
„ 1,000,000 nonvolatile WRITE cycles
„ 100 year nonvolatile memory data retention
„ 20-lead SOIC and TSSOP packages
„ Industrial temperature range
The CAT5221 is two Digitally Programmable
Potentiometers (DPPs™) integrated with control logic
and 16 bytes of NVRAM memory. Each DPP consists
of a series of 63 resistive elements connected
between two externally accessible end points. The tap
points between each resistive element are connected
to the wiper outputs with CMOS switches. A separate
6-bit control register (WCR) independently controls
the wiper tap switches for each DPP. Associated with
each wiper control register are four 6-bit non-volatile
memory data registers (DR) used for storing up to four
wiper settings. Writing to the wiper control register or
2
any of the non-volatile data registers is via a I C serial
bus. On power-up, the contents of the first data
register (DR0) for each of the four potentiometers is
automatically loaded into its respective wiper control
register (WCR).
The CAT5221 can be used as a potentiometer or as a
two terminal, variable resistor. It is intended for circuit
level or system level adjustments in a wide variety of
applications.
For Ordering Information details, see page 15.
PIN CONFIGURATION
FUNCTIONAL DIAGRAM
SOIC 20 Lead (W)
TSSOP 20 Lead (Y)
RW0
1
20
VCC
RL0
2
19
NC
RH0
3
18
NC
A0
4
17
NC
A2
5 CAT 16
6 5221 15
A1
RW1
RL1
7
14
SCL
RH1
8
13
NC
SDA
9
12
NC
GND
10
11
NC
RH0
SCL
SDA
I2C
INTERFACE
WIPER
CONTROL
REGISTERS
RW0
RW1
A3
A0
A1
A2
A3
CONTROL
LOGIC
NONVOLATILE
DATA
REGISTERS
RL0
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
RH1
1
RL1
Doc. No. MD-2113 Rev. M
CAT5221
PIN DESCRIPTION
Pin (SOIC)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Name
RW0
RL0
RH0
A0
A2
RW1
RL1
RH1
SDA
GND
NC
NC
NC
SCL
A3
A1
NC
NC
NC
VCC
Function
Wiper Terminal for Potentiometer 0
Low Reference Terminal for Potentiometer 0
High Reference Terminal for Potentiometer 0
Device Address, LSB
Device Address
Wiper Terminal for Potentiometer 1
Low Reference Terminal for Potentiometer 1
High Reference Terminal for Potentiometer 1
Serial Data Input/Output
Ground
No Connect
No Connect
No Connect
Bus Serial Clock
Device Address
Device Address
No Connect
No Connect
No Connect
Supply Voltage
PIN DESCRIPTION
DEVICE OPERATION
SCL: Serial Clock
The CAT5221 serial clock input pin is used to clock
all data transfers into or out of the device.
The CAT5221 is two resistor arrays integrated with I2C
serial interface logic, two 6-bit wiper control registers
and eight 6-bit, non-volatile memory data registers.
Each resistor array contains 63 separate resistive
elements connected in series. The physical ends of
each array are equivalent to the fixed terminals of a
mechanical potentiometer (RH and RL). RH and RL are
symmetrical and may be interchanged. The tap
positions between and at the ends of the series resis–
tors are connected to the output wiper terminals (RW) by
a CMOS transistor switch. Only one tap point for each
potentiometer is connected to its wiper terminal at a
time and is determined by the value of the wiper control
register. Data can be read or written to the wiper control
registers or the non-volatile memory data registers via
the I2C bus. Additional instructions allow data to be
transferred between the wiper control registers and
each respective potentiometer's non-volatile data
registers. Also, the device can be instructed to operate
in an "increment/decrement" mode.
SDA: Serial Data
The CAT5221 bidirectional serial data pin is used to
transfer data into and out of the device. The SDA pin
is an open drain output and can be wire-Or'd with
the other open drain or open collector outputs.
A0, A1, A2, A3: Device Address Inputs
These inputs set the device address when
addressing multiple devices. A total of sixteen
devices can be addressed on a single bus. A match
in the slave address must be made with the address
input in order to initiate communication with the
CAT5221.
RH, RL: Resistor End Points
The two sets of RH and RL pins are equivalent to the
terminal connections on a mechanical potentiometer.
RW: Wiper
The two RW pins are equivalent to the wiper terminal
of a mechanical potentiometer.
Doc. No. MD-2113 Rev. M
2
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
ABSOLUTE MAXIMUM RATINGS(1)
Parameter
Temperature Under Bias
Storage Temperature
Voltage on any Pin with Respect to VSS(2)
VCC with Respect to Ground
Package Power Dissipation Capability (TA = 25°C)
Lead Soldering Temperature (10s)
Wiper Current
Ratings
-55 to +125
-65 to +150
Units
°C
°C
-2.0 to +VCC +2.0
V
-2.0 to +7.0
1.0
300
±12
V
W
°C
mA
Ratings
-40 to +85
Units
°C
RECOMMENDED OPERATING CONDITIONS
Vcc = +2.5 V to +6 V
Parameter
Operating Ambient Temperature (Industrial)
POTENTIOMETER CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
RPOT
RPOT
RPOT
RPOT
IW
RW
RW
VTERM
VN
TCRPOT
TCRATIO
CH/CL/CW
fc
Potentiometer Resistance (-00)
Potentiometer Resistance (-50)
Potentiometer Resistance (-10)
Potentiometer Resistance (-2.5)
Potentiometer Resistance Tolerance
RPOT Matching
Power Rating
Wiper Current
Wiper Resistance
Wiper Resistance
Voltage on any RH or RL Pin
Noise
Resolution
Absolute Linearity (5)
Relative Linearity (6)
Temperature Coefficient of RPOT
Ratiometric Temp. Coefficient
Potentiometer Capacitances
Frequency Response
Test Conditions
Min
Typ
Max
100
50
10
2.5
25°C, each pot
IW = +3 mA @ VCC =3 V
IW = +3 mA @ VCC = 5 V
VSS = 0 V
(4)
RW(n)(actual) - R(n)(expected)(8)
RW(n+1) - [RW(n)+LSB](8)
(4)
(4)
(4)
RPOT = 50 kΩ
80
GND
±20
1
50
±6
300
150
VCC
TBD
1.6
±1
±0.2
±300
20
10/10/25
0.4
Units
kΩ
kΩ
kΩ
kΩ
%
%
mW
mA
Ω
Ω
nV/√Hz
%
LSB(7)
LSB(7)
ppm/°C
ppm/°C
pF
MHz
Notes:
(1) Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions outside of those listed in the operational sections of this
specification is not implied. Exposure to any absolute maximum rating for extended periods may affect device performance and reliability.
(2) The minimum DC input voltage is –0.5 V. During transitions, inputs may undershoot to –2.0 V for periods of less than 20 ns. Maximum
DC voltage on output pins is VCC +0.5 V, which may overshoot to VCC +2.0 V for periods of less than 20 ns.
(3) Latch-up protection is provided for stresses up to 100 mA on address and data pins from –1 V to VCC + 1 V.
(4) This parameter is tested initially and after a design or process change that affects the parameter.
(5) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
(6) Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
(7) LSB = RTOT / 63 or (RH - RL) / 63, single pot
(8) n = 0, 1, 2, ..., 63
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
3
Doc. No. MD-2113 Rev. M
CAT5221
D.C. OPERATING CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
Test Conditions
Min
Typ
Max
Units
fSCL = 400 kHz
1
mA
VIN = GND or VCC; SDA Open
1
µA
VIN = GND to VCC
10
µA
VOUT = GND to VCC
10
µA
ICC
Power Supply Current
ISB
Standby Current (VCC = 5.0 V)
ILI
Input Leakage Current
ILO
Output Leakage Current
VIL
Input Low Voltage
-1
VCC x 0.3
V
VIH
Input High Voltage
VCC x 0.7
VCC + 1.0
V
VOL1
Output Low Voltage (VCC = 3.0 V)
0.4
V
IOL = 3 mA
CAPACITANCE
TA = 25°C, f = 1.0 MHz, VCC = 5 V
Symbol
Parameter
Max
Units
CI/O(1)
Input/Output Capacitance (SDA)
VI/O = 0 V
8
pF
Input Capacitance (A0, A1, A2, A3, SCL)
VIN = 0 V
6
pF
CIN
(1)
Test Conditions
Min
Typ
A.C. CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol
fSCL
(1)
TI
tAA
tBUF
(1)
Parameter
Min
Typ
Max
Units
Clock Frequency
400
kHz
Noise Suppression Time Constant at SCL, SDA Inputs
50
ns
SLC Low to SDA Data Out and ACK Out
0.9
µs
Time the Bus Must Be Free Before a New Transmission Can Start
1.2
µs
Start Condition Hold Time
0.6
µs
tLOW
Clock Low Period
1.2
µs
tHIGH
Clock High Period
0.6
µs
tSU:STA
Start Condition Setup Time (For a Repeated Start Condition)
0.6
µs
tHD:DAT
Data in Hold Time
0
ns
tSU:DAT
Data in Setup Time
100
ns
tHD:STA
(1)
tR
(1)
tF
tSU:STO
tDH
SDA and SCL Rise Time
0.3
SDA and SCL Fall Time
300
µs
ns
Stop Condition Setup Time
0.6
µs
Data Out Hold Time
50
ns
POWER UP TIMING (1)
Over recommended operating conditions unless otherwise stated.
Symbol
Parameter
tPUR
tPUW
Min
Typ
Max
Units
Power-up to Read Operation
1
ms
Power-up to Write Operation
1
ms
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
Doc. No. MD-2113 Rev. M
4
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
WRITE CYCLE LIMITS
Over recommended operating conditions unless otherwise stated.
Symbol
Parameter
tWR
Min
Typ
Max
Units
5
ms
Write Cycle Time
The write cycle is the time from a valid stop condition of a write sequence to the end of the internal program/erase
cycle. During the write cycle, the bus interface circuits are disabled, SDA is allowed to remain high, and the
device does not respond to its slave address.
RELIABILITY CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol
Parameter
Reference Test Method
(1)
Endurance
MIL-STD-883, Test Method 1033
1,000,000
Cycles/Byte
Data Retention
MIL-STD-883, Test Method 1008
100
Years
ESD Susceptibility
MIL-STD-883, Test Method 3015
2000
Volts
Latch-Up
JEDEC Standard 17
100
mA
NEND
TDR
(1)
(1)
VZAP
ILTH
(1)(2)
Min
Typ
Max
Units
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
(2) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated.
Figure 1. Bus Timing
tF
tHIGH
tLOW
tR
tLOW
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA IN
tAA
tBUF
tDH
SDA OUT
Figure 2. Write Cycle Timing
SCL
8TH BIT
BYTE n
SDA
ACK
tWR
STOP
CONDITION
START
CONDITION
ADDRESS
Figure 3. Start/Stop Timing
SDA
SCL
START BIT
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
STOP BIT
5
Doc. No. MD-2113 Rev. M
CAT5221
of the particular slave device it is requesting. The four
most significant bits of the 8-bit slave address are
fixed as 0101 for the CAT5221 (see Figure 5). The
next four significant bits (A3, A2, A1, A0) are the
device address bits and define which device the
Master is accessing. Up to sixteen devices may be
individually addressed by the system. Typically, +5V
and ground are hard-wired to these pins to establish
the device's address.
SERIAL BUS PROTOCOL
The following defines the features of the I2C bus
protocol:
(1) Data transfer may be initiated only when the bus
is not busy.
(2) During a data transfer, the data line must remain
stable whenever the clock line is high. Any
changes in the data line while the clock is high will
be interpreted as a START or STOP condition.
After the Master sends a START condition and the
slave address byte, the CAT5221 monitors the bus
and responds with an acknowledge (on the SDA line)
when its address matches the transmitted slave
address.
The device controlling the transfer is a master,
typically a processor or controller, and the device
being controlled is the slave. The master will always
initiate data transfers and provide the clock for both
transmit and receive operations. Therefore, the
CAT5221 will be considered a slave device in all
applications.
Acknowledge
After a successful data transfer, each receiving device
is required to generate an acknowledge. The
Acknowledging device pulls down the SDA line during
the ninth clock cycle, signaling that it received the 8
bits of data.
START Condition
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of
SDA when SCL is HIGH. The CAT5221 monitors the
SDA and SCL lines and will not respond until this
condition is met.
The CAT5221 responds with an acknowledge after
receiving a START condition and its slave address. If
the device has been selected along with a write
operation, it responds with an acknowledge after
receiving each 8-bit byte.
STOP Condition
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must
end with a STOP condition.
When the CAT5221 is in a READ mode it transmits 8
bits of data, releases the SDA line, and monitors the
line for an acknowledge. Once it receives this
acknowledge, the CAT5221 will continue to transmit
data. If no acknowledge is sent by the Master, the
device terminates data transmission and waits for a
STOP condition.
DEVICE ADDRESSING
The bus Master begins a transmission by sending a
START condition. The Master then sends the address
Figure 4. Acknowledge Timing
SCL FROM
MASTER
1
8
9
DATA OUTPUT
FROM TRANSMITTER
DATA OUTPUT
FROM RECEIVER
ACKNOWLEDGE
START
Doc. No. MD-2113 Rev. M
6
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
Acknowledge Polling
The disabling of the inputs can be used to take
advantage of the typical write cycle time. Once the
stop condition is issued to indicate the end of the
host's write operation, the CAT5221 initiates the
internal write cycle. ACK polling can be initiated
immediately. This involves issuing the start condition
followed by the slave address. If the CAT5221 is still
busy with the write operation, no ACK will be returned.
If the CAT5221 has completed the write operation, an
ACK will be returned and the host can then proceed
with the next instruction operation.
WRITE OPERATION
In the Write mode, the Master device sends the
START condition and the slave address information to
the Slave device. After the Slave generates an
acknowledge, the Master sends the instruction byte
that defines the requested operation of CAT5221. The
instruction byte consist of a four-bit opcode followed
by two register selection bits and two pot selection
bits. After receiving another acknowledge from the
Slave, the Master device transmits the data to be
written into the selected register. The CAT5221
acknowledges once more and the Master generates
the STOP condition, at which time if a nonvolatile data
register is being selected, the device begins an
internal programming cycle to non-volatile memory.
While this internal cycle is in progress, the device will
not respond to any request from the Master device.
Figure 5. Slave Address Bits
CAT5221
*
0
1
0
1
A3
A2
A1
A0
A0, A1, A2 and A3 correspond to pin A0, A1, A2 and A3 of the device.
** A0, A1, A2 and A3 must compare to its corresponding hard wired input pins.
Figure 6. Write Timing
BUS ACTIVITY:
MASTER
SDA LINE
S
T
A
R
T
INSTRUCTION
BYTE
SLAVE/DPP
ADDRESS
Fixed
Variable
op code
DR WCR DATA
S
P
A
C
K
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
Pot/WCR Data Register
Address
Address
S
T
O
P
A
C
K
7
A
C
K
Doc. No. MD-2113 Rev. M
CAT5221
INSTRUCTIONS AND REGISTER
DESCRIPTION
INSTRUCTION BYTE
The next byte sent to the CAT5221 contains the
instruction and register pointer information. The four
most significant bits used provide the instruction
opcode I [3:0]. The P0 bit points to one of the Wiper
Control Registers. The least two significant bits, R1
and R0, point to one of the four data registers of each
associated potentiometer. The format is shown in
Table 2.
INSTRUCTIONS
SLAVE ADDRESS BYTE
The first byte sent to the CAT5221 from the master/
processor is called the Slave/DPP Address Byte. The
most significant four bits of the slave address are a
device type identifier. These bits for the CAT5221 are
fixed at 0101[B] (refer to Table 1).
Data Register Selection
The next four bits, A3 - A0, are the internal slave
address and must match the physical device address
which is defined by the state of the A3 - A0 input pins
for the CAT5221 to successfully continue the com–
mand sequence. Only the device which slave address
matches the incoming device address sent by the
master executes the instruction. The A3 - A0 inputs
can be actively driven by CMOS input signals or tied
to VCC or VSS.
Data Register Selected
R1
R0
DR0
0
0
DR1
0
1
DR2
1
0
DR3
1
1
Table 1. Identification Byte Format
Device Type
Identifier
Slave Address
ID3
ID2
ID1
ID0
0
1
0
1
A3
A2
A1
A0
(MSB)
(LSB)
Table 2. Instruction Byte Format
Instruction
Opcode
I3
(MSB)
Doc. No. MD-2113 Rev. M
I2
WCR/Pot Selection
I1
0
I0
8
P0
Data Register
Selection
R1
R0
(LSB)
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
four Data Registers and the associated Wiper Control
Register. Any data changes in one of the Data
Registers is a non-volatile operation and will take a
maximum of 5ms.
WIPER CONTROL AND DATA REGISTERS
Wiper Control Register (WCR)
The CAT5221 contains two 6-bit Wiper Control
Registers, one for each potentiometer. The Wiper
Control Register output is decoded to select one of 64
switches along its resistor array. The contents of the
WCR can be altered in four ways: it may be written by
the host via Write Wiper Control Register instruction; it
may be written by transferring the contents of one of
four associated Data Registers via the XFR Data
Register instruction, it can be modified one step at a
time by the Increment/decrement instruction (see
Instruction section for more details). Finally, it is
loaded with the content of its data register zero (DR0)
upon power-up.
If the application does not require storage of multiple
settings for the potentiometer, the Data Registers can
be used as standard memory locations for system
parameters or user preference data.
Instructions
Four of the nine instructions are three bytes in length.
These instructions are:
— Read Wiper Control Register – read the current
wiper position of the selected potentiometer in
the WCR
— Write Wiper Control Register – change current
wiper position in the WCR of the selected
potentiometer
The Wiper Control Register is a volatile register that
loses its contents when the CAT5221 is powereddown. Although the register is automatically loaded
with the value in DR0 upon power-up, this may be
different from the value present at power-down.
— Read Data Register – read the contents of the
selected Data Register
— Write Data Register – write a new value to the
selected Data Register
Data Registers (DR)
Each potentiometer has four 6-bit non-volatile Data
Registers. These can be read or written directly by the
host. Data can also be transferred between any of the
The basic sequence of the three byte instructions is
illustrated in Figure 8. These three-byte instructions
Table 3. Instruction Set
Instruction Set
WCR0/
P0
R1
R0
1 0 0 1 0
1/0
0
0
1 0 1 0 0
1/0
0
0
Read Data Register
1 0 1 1 0
1/0
1/0
1/0
Write Data Register
1 1 0 0 0
1/0
1/0
1/0
XFR Data Register to
Wiper Control Register
1 1 0 1 0
1/0
1/0
1/0
XFR Wiper Control
Register to Data Register
1 1 1 0 0
1/0
1/0
1/0
Global XFR Data Registers
0 0 0 1 0
to Wiper Control Registers
0
1/0
1/0
Global XFR Wiper Control
Registers to Data Register
1 0 0 0 0
0
1/0
1/0
Increment/Decrement
Wiper Control Register
0 0 1 0 0
1/0
0
0
Instruction
Read Wiper Control
Register
Write Wiper Control
Register
I3
I2
I1
I0
0
Operation
Read the contents of the Wiper Control
Register pointed to by P0
Write new value to the Wiper Control Register
pointed to by P0
Read the contents of the Data Register
pointed to by P0 and R1-R0
Write new value to the Data Register pointed
to by P0 and R1-R0
Transfer the contents of the Data Register
pointed to by P0 and R1-R0 to its associated
Wiper Control Register
Transfer the contents of the Wiper Control
Register pointed to by P0 to the Data
Register pointed to by R1-R0
Transfer the contents of the Data Registers
pointed to by R1-R0 of all four pots to their
respective Wiper Control Registers
Transfer the contents of both Wiper Control
Registers to their respective data Registers
pointed to by R1-R0 of all four pots
Enable Increment/decrement of the Control
Latch pointed to by P0
Note: 1/0 = data is one or zero
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
9
Doc. No. MD-2113 Rev. M
CAT5221
exchange data between the WCR and one of the Data
Registers. The WCR controls the position of the wiper.
The response of the wiper to this action will be
delayed by tWRL. A transfer from the WCR (current
wiper position), to a Data Register is a write to nonvolatile memory and takes a maximum of tWR to
complete. The transfer can occur between one of the
four potentiometers and one of its associated
registers; or the transfer can occur between all
potentiometers and one associated register.
— Global XFR Data Register to Wiper Control
Register
This transfers the contents of all specified Data
Registers to the associated Wiper Control
Registers.
Four instructions require a two-byte sequence to
complete, as illustrated in Figure 7. These instructions
transfer data between the host/processor and the
CAT5221; either between the host and one of the data
registers or directly between the host and the Wiper
Control Register. These instructions are:
INCREMENT/DECREMENT COMMAND
— Global XFR Wiper Counter Register to Data
Register
This transfers the contents of all Wiper Control
Registers to the specified associated Data
Registers.
The final command is Increment/Decrement (Figure 5
and 9). The Increment/Decrement command is
different from the other commands. Once the
command is issued and the CAT5221 has responded
with an acknowledge, the master can clock the
selected wiper up and/or down in one segment steps;
thereby providing a fine tuning capability to the host.
For each SCL clock pulse (tHIGH) while SDA is HIGH,
the selected wiper will move one resistor segment
towards the RH terminal. Similarly, for each SCL clock
pulse while SDA is LOW, the selected wiper will move
one resistor segment towards the RL terminal.
— XFR Data Register to Wiper Control Register
This transfers the contents of one specified Data
Register to the associated Wiper Control Register.
— XFR Wiper Control Register to Data Register
This transfers the contents of the specified Wiper
Control Register to the specified associated Data
Register.
See Instructions format for more detail.
Figure 7. Two-Byte Instruction Sequence
SDA
0
1
0
1
S ID3 ID2 ID1 ID0 A3
T
A
R
Device ID
T
A2 A1 A0
A I3
C
K
Internal
Address
I2
I1
0 P0 R1 R0
I0
Instruction
Opcode
Pot/WCR Register
Address Address
A
C
K
S
T
O
P
Figure 8. Three-Byte Instruction Sequence
SDA
0
1
0
1
S ID3 ID2 ID1 ID0 A3
T
A
Device ID
R
T
A2
A0 A I3
C
K
Internal
Address
A1
I2
I1 I0
R1 R0 A
C
K
Pot/WCR Data
Address Register
Address
0 P0
Instruction
Opcode
D7 D6 D5 D4 D3 D2 D1 D0
A
C
K
WCR[7:0]
or
Data Register D[7:0]
S
T
O
P
Figure 9. Increment/Decrement Instruction Sequence
0
SDA
S
T
A
R
T
1
0
1
ID3 ID2 ID1 ID0
Doc. No. MD-2113 Rev. M
Device ID
A3
A2 A1 A0
Internal
Address
A
C
K
I3
I2
I1
Instruction
Opcode
10
I0
0
P0
R1 R0
Pot/WCR Data
Address Register
Address
A
C
K
I
N
C
1
I
N
C
2
I
N
C
n
D
E
C
1
D
E
C
n
S
T
O
P
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
Figure 10. Increment/Decrement Timing Limits
INC/DEC
Command
Issued
tWRID
SCL
SDA
Voltage Out
RW
INSTRUCTION FORMAT
Read Wiper Control Register (WCR)
S
T
A
R
T
DEVICE ADDRESSES
0 1 0 1 A3 A2 A1 A0
A
C
K
INSTRUCTION
1 0 0 1 0 P0 0 0
A
C
K
DATA
7 6 5 4 3 2 1 0
A
C
K
S
T
O
P
A
C
K
S
T
O
P
Write Wiper Control Register (WCR)
S
T
A
R
T
DEVICE ADDRESSES
0 1 0 1 A3 A2 A1 A0
A
C
K
INSTRUCTION
1 0 1 0 0 P0 0 0
A
C
K
DATA
7 6 5 4 3 2 1 0
Read Data Register (DR)
S
T
A
R
T
DEVICE ADDRESSES
0 1 0 1 A3 A2 A1 A0
A
C
K
INSTRUCTION
1 0 1 1 0 P0 R1 R0
A
C
K
DATA
A S
7 6 5 4 3 2 1 0 C T
K O
P
Write Data Register (DR)
S
T
A
R
T
DEVICE ADDRESSES
0 1 0 1 A3 A2 A1 A0
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
A
C
K
INSTRUCTION
1 1 0 0 0 P0 R1 R0
11
A
C
K
DATA
A S
7 6 5 4 3 2 1 0 C T
K O
P
Doc. No. MD-2113 Rev. M
CAT5221
Global Transfer Data Register (DR) to Wiper Control Register (WCR)
S
T
A
R
T
DEVICE ADDRESSES
0 1 0 1 A3 A2 A1 A0
A
C
K
INSTRUCTION
A
0 0 0 1 0 0 R1 R0 C
K
S
T
O
P
Global Transfer Wiper Control Register (WCR) to Data Register (DR)
S
T
A
R
T
DEVICE ADDRESSES
0 1 0 1 A3 A2 A1 A0
A
C
K
INSTRUCTION
A
1 0 0 0 0 0 R1 R0 C
K
S
T
O
P
Transfer Wiper Control Register (WCR) to Data Register (DR)
S
T
A
R
T
DEVICE ADDRESSES
A
0 1 0 1 A3 A2 A1 A0 C
K
INSTRUCTION
A S
1 1 1 0 0 P0 R1 R0 C T
K O
P
Transfer Data Register (DR) to Wiper Control Register (WCR)
S
T
A
R
T
DEVICE ADDRESSES
A
0 1 0 1 A3 A2 A1 A0 C
K
INSTRUCTION
A S
1 1 0 1 0 P0 R1 R0 C T
K O
P
Increment (I)/Decrement (D) Wiper Control Register (WCR)
S
T
A
R
T
DEVICE ADDRESSES
A
0 1 0 1 A3 A2 A1 A0 C
K
INSTRUCTION
0 0 1 0 0 P0 0 0
A
C
K
DATA
I/D I/D
...
S
I/D I/D T
O
P
Notes:
(1) Any write or transfer to the Non-volatile Data Registers is followed by a high voltage cycle after a STOP has been issued.
Doc. No. MD-2113 Rev. M
12
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
PACKAGING OUTLINE DRAWINGS
SOIC 20-Lead 300 mil Wide (W) (1)(2)
E1
SYMBOL
MIN
NOM
MAX
A
2.36
2.49
2.64
A1
0.10
0.30
A2
2.05
2.55
b
0.31
0.41
0.51
c
0.20
0.27
0.33
D
12.60
12.80
13.00
E
10.01
10.30
10.64
E1
7.40
7.50
7.60
E
e
b
e
PIN#1 IDENTIFICATION
1.27 BSC
h
0.25
0.75
L
0.40
θ
0°
0.81
1.27
8°
θ1
5°
15°
TOP VIEW
D
h
A2
A
h
θ1
θ
θ1
L
A1
SIDE VIEW
c
END VIEW
Notes:
(1) All dimensions are in millimeters.
(2) Complies with JEDEC specification MS-013.
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
13
Doc. No. MD-2113 Rev. M
CAT5221
TSSOP 20-Lead (Y) (1)(2)
b
SYMBOL
MIN
NOM
A
E1
E
MAX
1.20
A1
0.05
0.15
A2
0.80
1.05
b
0.19
0.30
c
0.09
D
6.40
6.50
E
6.30
6.40
6.50
E1
4.30
4.40
4.50
e
L
0.65 BSC
0.45
L1
θ1
0.20
6.60
0.60
0.75
1.00 REF
0°
8°
e
TOP VIEW
D
c
A2
A
θ1
L
A1
L1
SIDE VIEW
END VIEW
Notes:
(1) All dimensions are in millimeters. Angles in degree.
(2) Complies with JEDEC specification MO-153.
Doc. No. MD-2113 Rev. M
14
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
CAT5221
EXAMPLE OF ORDERING INFORMATION (1)
Prefix
Device #
CAT
5221
Suffix
W
Optional
Company ID
I
-10
Temperature Range
I = Industrial (-40ºC to 85ºC)
Product
Number
5221
Package
W: SOIC
Y: TSSOP
T1
Tape & Reel
T: Tape & Reel
1: 1,000/Reel – SOIC
2: 2,000/Reel – TSSOP
Resistance
-25: 2.5 kΩ
-10: 10 kΩ
-50: 50 kΩ
-00: 100 kΩ
ORDERING INFORMATION
Orderable Part Number
Resistance (kΩ)
CAT5221WI-25-T1
2.5
CAT5221WI-10-T1
10
CAT5221WI-50-T1
50
CAT5221WI-00-T1
100
CAT5221YI-25-T2
2.5
CAT5221YI-10-T2
10
CAT5221YI-50-T2
50
CAT5221YI-00-T2
100
CAT5221WI25
2.5
CAT5221WI10
10
CAT5221WI50
50
CAT5221WI00
100
CAT5221YI25
2.5
CAT5221YI10
10
CAT5221YI50
50
CAT5221YI00
100
Package
Lead Finish
SOIC
TSSOP
Matte-Tin
SOIC
TSSOP
Notes:
(1) All packages are RoHS-compliant (Lead-free, Halogen-free).
(2) The standard lead finish is Matte-Tin.
(3) This device used in the above example is a CAT5221WI-10-T1 (SOIC, Industrial Temperature, 10 kΩ, Tape & Reel, 1,000/Reel)
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
15
Doc. No. MD-2113 Rev. M
CAT5221
REVISION HISTORY
Date
30-Sep-03
Rev.
E
Reason
Deleted WP from Functional Diagram, pg. 1
01-Oct-03
F
Changed designation to Advance
10-Mar-04
G
Added TSSOP package in all areas
25-Mar-04
H
Updated TSSOP package drawing
08-Apr-04
I
Eliminated data sheet designation
Eliminated Commercial temperature range in all areas
Updated Potentiometer Characteristics
23-May-07
J
Updated Example of Ordering Information
Added MD- in front of Document No.
12-Mar-08
K
Updated Package Outline Drawing
01-Dec-08
L
Change logo and fine print to ON Semiconductor
28-Jul-09
M
Update Ordering Information table
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to
any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All
operating parameters, including “Typicals” must be validated for each customer application by customer's technical experts. SCILLC does not convey any license under its patent rights
nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer
purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and
distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated
with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal
Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada
Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada
Email: [email protected]
Doc. No. MD-2113 Rev. M
N. American Technical Support: 800-282-9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center:
Phone: 81-3-5773-3850
16
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
© 2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
Similar pages