AIMTEC AM30EW-4812DZ 30 watt | dc-dc converter Datasheet

Series AM30EW-Z
30 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Ultra Wide 4:1 input range
Efficiency up to 91%
Soft start
Continuous short circuit protection
•
•
•
•
Remote on/off control
Input/Output Isolation 1600VDC
Operating temperature -40ºC to + 75ºC
RoHS compliant
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
3.3
5
5.1
12
15
3.3
5
5.1
12
15
7.5
6
6
2.5
2
7.5
6
6
2.5
2
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±3
±1.25
±1
±3
±1.25
±1
AM30EW-2403SZ
AM30EW-2405SZ
AM30EW-2405.1SZ
AM30EW-2412SZ
AM30EW-2415SZ
AM30EW-4803SZ
AM30EW-4805SZ
AM30EW-4805.1SZ
AM30EW-4812SZ
AM30EW-4815SZ
Models
Dual output
Model
AM30EW-2405DZ
AM30EW-2412DZ
AM30EW-2415DZ
AM30EW-4805DZ
AM30EW-4812DZ
AM30EW-4815DZ
Models
Triple output
Maximum
Capacitive Load
(uF)
Efficiency
(%)
20000
14000
14000
2000
2000
20000
14000
14000
2000
2000
86
88
88
89
89
86
88
88
90
91
Maximum
Capacitive Load
(uF)
Efficiency
(%)
±3000
±1300
±1300
±3000
±1300
±1300
88
87
87
88
88
88
Model
Input
Voltage (V)
Output
Voltage (V)
Output
Auxiliary
Voltage (V)
Output Current
max (A)
Maximum
Capacitive
Load (uF)
Efficiency
(%)
AM30EW-240312TZ
AM30EW-240315TZ
AM30EW-240512TZ
AM30EW-240515TZ
AM30EW-480312TZ
AM30EW-480315TZ
AM30EW-480512TZ
AM30EW-480515TZ
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
3.3
3.3
5
5
3.3
3.3
5
5
±12
±15
±12
±15
±12
±15
±12
±15
5 / ±0.42
5 / ±0.33
4 / ±0.42
4 / ±0.33
5 / ±0.42
5 / ±0.33
4 / ±0.42
4 / ±0.33
15000 / ±220
15000 / ±220
8000 / ±220
8000 / ±220
15000 / ±220
15000 / ±220
8000 / ±220
8000 / ±220
88
88
90
90
88
88
90
90
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R11.J
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Input Specifications
Parameters
Nominal
24
48
Voltage range
Filter
Start up time
24
48
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
Vin 9~36
Vin 36~75
24V ON/OFF
48V ON/OFF
No Load Input Current
Under voltage lockout
Input reflected current
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Case/Input tested voltage
Resistance
Capacitance
3 sec
3 sec
Output Specifications
Parameters
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Thermal Shutdown
Line voltage regulation (Single)
Line voltage regulation (Dual)
Line voltage regulation (Triple)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Load voltage regulation (Triple)
Temperature coefficient
Ripple & Noise (Single and Dual)
Ripple & Noise (Triple)
Voltage adjustment range (single)
Minimum Load Current
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
www.aimtec.com
F 051e R11.J
Maximum
9-36
36-75
π (Pi) Network
30
-0.7 ~ 50
-0.7 ~ 100
VDC
ms
VDC
Typical
Rated
1600
1000
1500
Typical
±1
±1 / ±5
±5
100% load
Derating above 50
Typical
330
-40 to +125
Tel: +1 514 620 2722
2 of 6
ms
mA
VDC
mAp-p
Units
1600
VDC
VDC
MOhm
pF
Maximum
Main / Auxiliary
25% load on one output - 100% load on
second load
Main 100%, 25% load on Aux1 and 100%
±5
on Aux2
Zener diode clamp
120
Continuous
Auto-Recovery
Case temp
115
HL-LL
±0.2
HL-LL
±0.2
HL-LL Main / Auxiliary
±1 / ±5
0-100% load
±0.5
Balanced load
±1
10~100% Main / Auxiliary
±1 / ±5
±0.02
100
20MHz bandwidth, 3.3V/5V/5.1V/±5V
150
20MHz bandwidth, 12V/15V/±12V/±15V
20MHz bandwidth Main / Auxiliary
50 / 75
±10
10
Conditions
Units
100
ON: 3 ~12VDC or open circuit
OFF: 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3
100
50
8.8 / 7.9
17.8 / 16
20
Conditions
Voltage accuracy (Single and Dual)
Voltage accuracy (Triple)
Cross Regulation (Triple)
Typical
Units
%
%
%
o
C
%
%
%
%
%
%
%/oC
mV p-p
mV p-p
%
% of Max
Maximum
-40 to +75
105
Units
KHz
o
C
o
C
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Typical
Maximum
Units
%/ oC
2
Free Air Convection
95
% RH
Nickel coated Copper
30
g
2.00 x 1.00 x 0.4 inches
50.80 x 25.40 x 10.17 mm
Single & Dual: >450000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)
Triple: >320000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)
o
1.5mm from case for 10 sec
260
C
250
uS
±3
%
Safety Specifications
Parameters
Agency Approval
CE
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Standards
Pin Out Specifications
Pin
1
2
3
4
5
6
7
Single
+ V Input
- V Input
On/Off Control
+ V Output
-V Output
Trim
No Pin
Dual
+ V Input
- V Input
On/Off Control
+ V Output
Common
- V Output
No Pin
Triple
+ V Input
- V Input
On/Off Control
+ Vaux Output
- Vaux Output
Common
+ V Output
Dimensions
4
1
5
Bottom View
3
Diameter 1.00
(0.04)
www.aimtec.com
F 051e R11.J
5.08
(0.20)
10.16
(0.40)
2.54
(0.10)
6
10.16
(0.40)
25.40
(1.00)
2
10.16
(0.40)
2.54
(0.10)
5.08
(0.20)
5.08
(0.20)
50.80
(2.00)
10.16
(0.40)
Single and Dual Output Models
2.54
(0.10)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
7.64
(0.30)
5
2
25.40
(1.00)
7.64
(0.30)
4
1
Bottom View
6
3
7
2.54
(0.10)
2.54
(0.10)
10.16
(0.40)
5.08
(0.20)
2.54
(0.10)
50.80
(2.00)
5.08
(0.20)
5.08
(0.20)
10.16
(0.40)
Triple Output Models
5.08
(0.20)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
Trimming
Derating
Free Air Convection
50 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
75
80
100
Ambient Temperature º C
On/Off Control
+V input
On/Off
Control
4
DC/DC
Converter
5
6
-V input
7
Positive logic turns on the module during high logic and off during low logic.
Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be
either open collector or open drain.
www.aimtec.com
F 051e R11.J
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Recommended Circuits
C1
100uF, 100V
L
12uH
C2
1206, 470pF, 2KV
Conducted/Radiated Emissions
Single Output
L
+V output
+V input
C1
DC/DC
Converter
-V input
Load
-V output
C2
Conducted/Radiated Emissions
Dual Output
L
+V output
+V input
C1
DC/DC
Converter
Load
-V output
-V input
Load
Common
C2
Conducted/Radiated Emissions
Triple Output
L
+V input
C1
Load
+Vaux
Output
DC/DC
Converter
-Vaux
Output
+V output
-V input
Load
Load
Common
C2
www.aimtec.com
F 051e R11.J
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Surge/EFT
C1
220uF, 100V
Su ge/
+V input
4
DC/DC
Converter
C1
5
6
-V input
7
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.J
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages