eupec D3041N Netz-gleichrichterdiode rectifier diode Datasheet

Datenblatt / Data sheet
N
Netz-Gleichrichterdiode
Rectifier Diode
Zieldaten
D 3041N
Maßbild
1: Anode/Anode
1
2
2: Kathode/Cathode
Seite/page
3/7
Datenblatt / Data sheet
N
Netz-Gleichrichterdiode
Rectifier Diode
R,t – Werte
R
R,T-Werte
beidseitig
two-sided
anodenseitg
anode-sided
kathodenseitig
cathode-sided
Zieldaten
D 3041N
Analytische Elemente des transienten Wärmewiderstandes Z thJC
Analytical elements of transient thermal impedance Z thJC
Pos. n
1
2
3
4
5
Rthn [°C/W]
0,00295
0,002
0,00154
0,00098
0,00003
τn [s]
0,78008
0,13092
0,02165
0,00514
0,00104
Rthn [°C/W]
0,00804
0,00081
0,00239
0,0016
0,00046
τn [s]
5,11029
0,35916
0,09623
0,01197
0,00332
Rthn [°C/W]
0,0121
0,0004
0,00244
0,00155
0,00071
τn [s]
4,97289
0,48885
0,12071
0,01530
0,00427
Analytische Funktion / Analytical function:
ZthJC =
6
nmax
Σ
n=1
Rthn 1 − e
7
-t
τn
Transienter innerer Wärmewiderstand für DC/ Transient thermal impedance Z thJC = f(t) for DC
Beidseitige Kühlung / Two-sided cooling
Anodenseitige Kühlung / Anode-sided cooling
Kathodenseitige Kühlung / Cathode-sided cooling
Seite/page
4/7
Datenblatt / Data sheet
N
Netz-Gleichrichterdiode
Rectifier Diode
D 3041N
Zieldaten
Diagramme
Diagramme
Durchlasskennlinie
Grenzdurchlaßkennlinie / Limiting on-state characteristic iF = f(vF)
Tvj = Tvj max
Seite/page
5/7
N
Netz-Gleichrichterdiode
Rectifier Diode
Datenblatt / Data sheet
D 3041N
Zieldaten
Tc beidseitig
Sperrverzögerungsladung / Recovered charge Qr = f(-di/dt)
Tvj=Tvjmax, C = 1µF, R = 22Ω
Seite/page
6/7
N
Netz-Gleichrichterdiode
Rectifier Diode
Datenblatt / Data sheet
D 3041N
Zieldaten
Ta bei Sinus
Rückstromspitze / Peak reverse recovery current IRM = f(-di/dt)
Tvj=Tvjmax, C = 1µF, R = 22Ω
Seite/page
7/7
Terms & Conditions of Usage
Attention
The present product data is exclusively subscribed to technically experienced
staff. This Data Sheet is describing the specification of the products for which a
warranty is granted exclusively pursuant the terms and conditions of the supply
agreement. There will be no guarantee of any kind for the product and its
specifications. Changes to the Data Sheet are reserved.
You and your technical departments will have to evaluate the suitability of the
product for the intended application and the completeness of the product data
with respect to such application. Should you require product information in
excess of the data given in the Data Sheet, please contact your local Sales Office
via “www.eupec.com / sales & contact”.
Warning
Due to technical requirements the products may contain dangerous substances.
For information on the types in question please contact your local Sales Office via
“www.eupec.com / sales & contact”.
Similar pages