Eon EN29LV641H-90WCP 64 megabit (4096k x 16-bit) flash memory, cmos 3.0 volt-only uniform sector flash memory Datasheet

EN29LV641H/L EN29LV640U
EN29LV641H/L EN29LV640U
64 Megabit (4096K x 16-bit) Flash Memory, CMOS 3.0 Volt-only
Uniform Sector Flash Memory
FEATURES
• Single power supply operation
- Full voltage range: 2.7 to 3.6 volts for read,
erase and program operations
• Low power consumption (typical values at 5
MHz)
- 9 mA typical active read current
- 20 mA typical program/erase current
- Less than 1 µA current in standby or automatic
sleep mode.
• JEDEC standards compatible
- Pinout and software compatible with singlepower supply Flash standard
„
Software features:
• Sector Group Protection
- Provide locking of sectors to prevent program
or erase operations within individual sectors
- Additionally, temporary Sector Group
Unprotect allows code changes in previously
protected sectors.
• Standard DATA# polling and toggle bits
feature
• Unlock Bypass Program command supported
• Sector Erase Suspend / Resume modes:
Read and program another Sector during
Sector Erase Suspend Mode
• Manufactured on 0.18μm process
technology
• Support JEDEC Common Flash Interface
(CFI).
• Flexible Sector Architecture:
- One hundred and twenty-eight 32K-Word
sectors.
„
• Minimum 100K program/erase endurance
cycles.
•
-
High performance for program and erase
Word program time: 8µs typical
Sector Erase time: 500ms typical
Chip Erase time: 64s typical
• Package Options
Hardware features:
• RESET# hardware reset pin
- Hardware method to reset the device to read
mode.
• WP# input pin
- Write Protect (WP#) function allows
protection of first or last 32K-word sector,
regardless of previous sector protect status
• ACC input pin
- Acceleration (ACC) function provides
accelerated program times for higher
throughput for manufacturing.
- 48-pin TSOP
- 63 ball 11mm x 12mm FBGA
GENERAL DESCRIPTION
The EN29LV641H/L / EN29LV640U is a 64-Megabit (4,194,304x16), electrically erasable, read/write
non-volatile flash memory. Any word can be programmed typically in 8µs. This device is entirely
command set compatible with the JEDEC single-power-supply Flash standard.
The EN29LV641H/L / EN29LV640U is designed to allow either single Sector or full Chip erase
operation, where each Sector Group can be protected against program/erase operations or
temporarily unprotected to erase or program. The device can sustain a minimum of 100K
program/erase cycles on each Sector.
This Data Sheet may be revised by subsequent versions
1
or modifications due to changes in technical specifications.
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
PRODUCT SELECTOR GUIDE
Product Number
EN29LV641H/L / EN29LV640U
Regulated Voltage Range: VCC=3.0 – 3.6 V
70R
Speed Option
Full Voltage Range: VCC=2.7 – 3.6 V
90
Max Access Time (ns)
70
90
Max CE# Access Time (ns)
70
90
Max OE# Access Time (ns)
30
35
BLOCK DIAGRAM
RY/BY#
VCC
VSS
RESET#
DQ15-DQ0
Sector Protect Switches
Erase Voltage Generator
Input/Output Buffers
State
Control
WE#
WP#
ACC#
Command
Register
Program Voltage
Generator
Chip Enable
Output Enable
Logic
CE#
OE#
VCC Detector
Timer
Address Latch
STB
STB
Data Latch
Y-Decoder
Y-Gating
X-Decoder
Cell Matrix
A21-A0
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
2
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
CONNECTION DIAGRAMS
Note: No RY/BY# pin for TSOP package , VIO should be tied directly to VCC.
Note: No WP# pin for FBGA package VIO should be tied directly to VCC.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
3
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
TABLE 1. PIN DESCRIPTION
Pin Name
Function
A21-A0
22 Address inputs
DQ15-DQ0
16 Data Inputs/Outputs
LOGIC DIAGRAM
A21 – A0
DQ15 – DQ0
CE#
Chip Enable Input
CE#
OE#
Output Enable Input
OE#
WE#
WE#
Write Enable Input
WP#
WP#
Hardware Write Protect Input
ACC
Acceleration Input
RY/BY#
Ready/Busy status output
RESET#
Hardware Reset Input Pin
Vcc
Supply Voltage (2.7-3.6V)
VIO
Output Buffer Power Supply this pin
should be tied directly to VCC
Vss
Ground
NC
Not Connected to anything
ACC
RESET#
VIO
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Note: WP# pins are for EN29LV641H/L only.
RY/BY# is available for EN29LV640U only.
4
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
RY/BY#
EN29LV641H/L EN29LV640U
ORDERING INFORMATION
EN29LV641
H
─
90
T
I
P
PACKAGING CONTENT
(Blank) = Conventional
P = Pb Free
TEMPERATURE RANGE
I = Industrial (-40°C to +85°C)
C = Commercial (0°C to +70°C)
PACKAGE
T = 48-pin TSOP
W= 63-Ball Fine Pitch Ball Grid Array (FBGA)
0.80mm pitch, 11mm x 12mm package
SPEED OPTION
See Product Selector Guide and Valid Combinations
SECTOR for WRITE PROTECT (WP#=0)
H = highest address sector protected
L = lowest address sector protected
BASE PART NUMBER
EN29LV641 / EN29LV640U
64 Megabit(4M x 16-Bit) Uniform Sector Flash
Optional Data I/O voltage
3V Read, Erase and Program
PRODUCT SELECTOR GUIDE
Valid Combinations for TSOP Packages
EN29LV641H–90
EN29LV641L–90
EN29LV641H–70R,
EN29LV641L–70R
Vcc
Vcc = 2.7V-3.6V
TI, TC
Vcc = 3.0V-3.6V
Valid Combinations for FBGA Packages
EN29LV640U–90
EN29LV640U–70R
Vcc
Vcc = 2.7V-3.6V
WI, WC
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Vcc = 3.0V-3.6V
5
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Table 2. Sector (Group) Address Tables
Sector Group
Protect/Unprotect
Sector
Group
SG0
SG1
SG2
SG3
SG4
SG5
SG6
SG7
A21-A17
Sector Address Range for Sector Erase
Sector
A21
A20
A19
A18
A17
A16
A15
Address Range
(hexadecimal)
SA0
0
0
0
0
0
0
0
000000–007FFF
SA1
0
0
0
0
0
0
1
008000–00FFFF
SA2
0
0
0
0
0
1
0
010000–017FFF
SA3
0
0
0
0
0
1
1
018000–01FFFF
SA4
0
0
0
0
1
0
0
020000–027FFF
SA5
0
0
0
0
1
0
1
028000–02FFFF
SA6
0
0
0
0
1
1
0
030000–037FFF
SA7
0
0
0
0
1
1
1
038000–03FFFF
SA8
0
0
0
1
0
0
0
040000–047FFF
SA9
0
0
0
1
0
0
1
048000–04FFFF
SA10
0
0
0
1
0
1
0
050000–057FFF
SA11
0
0
0
1
0
1
1
058000–05FFFF
SA12
0
0
0
1
1
0
0
060000–067FFF
SA13
0
0
0
1
1
0
1
068000–06FFFF
SA14
0
0
0
1
1
1
0
070000–077FFF
SA15
0
0
0
1
1
1
1
078000–07FFFF
SA16
0
0
1
0
0
0
0
080000–087FFF
SA17
0
0
1
0
0
0
1
088000–08FFFF
SA18
0
0
1
0
0
1
0
090000–097FFF
SA19
0
0
1
0
0
1
1
098000–09FFFF
SA20
0
0
1
0
1
0
0
0A0000–0A7FFF
SA21
0
0
1
0
1
0
1
0A8000–0AFFFF
SA22
0
0
1
0
1
1
0
0B0000–0B7FFF
SA23
0
0
1
0
1
1
1
0B8000–0BFFFF
SA24
0
0
1
1
0
0
0
0C0000–0C7FFF
SA25
0
0
1
1
0
0
1
0C8000–0CFFFF
SA26
0
0
1
1
0
1
0
0D0000–0D7FFF
SA27
0
0
1
1
0
1
1
0D8000–0DFFFF
SA28
0
0
1
1
1
0
0
0E0000–0E7FFF
SA29
0
0
1
1
1
0
1
0E8000–0EFFFF
SA30
0
0
1
1
1
1
0
0F0000–0F7FFF
SA31
0
0
1
1
1
1
1
0F8000–0FFFFF
00000
00001
00010
00011
00100
00101
00110
00111
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
6
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Sector
Group
SG8
SG9
SG10
SG11
SG12
SG13
SG14
SG15
A21-A17
Sector
A21
A20
A19
A18
A17
A16
A15
Address Range
(hexadecimal)
SA32
0
1
0
0
0
0
0
100000–107FFF
SA33
0
1
0
0
0
0
1
108000–10FFFF
SA34
0
1
0
0
0
1
0
110000–117FFF
SA35
0
1
0
0
0
1
1
118000–11FFFF
SA36
0
1
0
0
1
0
0
120000–127FFF
SA37
0
1
0
0
1
0
1
128000–12FFFF
SA38
0
1
0
0
1
1
0
130000–137FFF
SA39
0
1
0
0
1
1
1
138000–13FFFF
SA40
0
1
0
1
0
0
0
140000–147FFF
SA41
0
1
0
1
0
0
1
148000–14FFFF
SA42
0
1
0
1
0
1
0
150000–157FFF
SA43
0
1
0
1
0
1
1
158000–15FFFF
SA44
0
1
0
1
1
0
0
160000–167FFF
SA45
0
1
0
1
1
0
1
168000–16FFFF
SA46
0
1
0
1
1
1
0
170000–177FFF
SA47
0
1
0
1
1
1
1
178000–17FFFF
SA48
0
1
1
0
0
0
0
180000–187FFF
SA49
0
1
1
0
0
0
1
188000–18FFFF
SA50
0
1
1
0
0
1
0
190000–197FFF
SA51
0
1
1
0
0
1
1
198000–19FFFF
SA52
0
1
1
0
1
0
0
1A0000–1A7FFF
SA53
0
1
1
0
1
0
1
1A8000–1AFFFF
SA54
0
1
1
0
1
1
0
1B0000–1B7FFF
SA55
0
1
1
0
1
1
1
1B8000–1BFFFF
SA56
0
1
1
1
0
0
0
1C0000–1C7FFF
SA57
0
1
1
1
0
0
1
1C8000–1CFFFF
SA58
0
1
1
1
0
1
0
1D0000–1D7FFF
SA59
0
1
1
1
0
1
1
1D8000–1DFFFF
SA60
0
1
1
1
1
0
0
1E0000–1E7FFF
SA61
0
1
1
1
1
0
1
1E8000–1EFFFF
SA62
0
1
1
1
1
1
0
1F0000–1F7FFF
SA63
0
1
1
1
1
1
1
1F8000–1FFFFF
01000
01001
01010
01011
01100
01101
01110
01111
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
7
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Sector
Group
SG16
SG17
SG18
SG19
SG20
SG21
SG22
SG23
A21-A17
Sector
A21
A20
A19
A18
A17
A16
A15
Address Range
(hexadecimal)
SA64
1
0
0
0
0
0
0
200000–207FFF
SA65
1
0
0
0
0
0
1
208000–20FFFF
SA66
1
0
0
0
0
1
0
210000–217FFF
SA67
1
0
0
0
0
1
1
218000–21FFFF
SA68
1
0
0
0
1
0
0
220000–227FFF
SA69
1
0
0
0
1
0
1
228000–22FFFF
SA70
1
0
0
0
1
1
0
230000–237FFF
SA71
1
0
0
0
1
1
1
238000–23FFFF
SA72
1
0
0
1
0
0
0
240000–247FFF
SA73
1
0
0
1
0
0
1
248000–24FFFF
SA74
1
0
0
1
0
1
0
250000–257FFF
SA75
1
0
0
1
0
1
1
258000–25FFFF
SA76
1
0
0
1
1
0
0
260000–267FFF
SA77
1
0
0
1
1
0
1
268000–26FFFF
SA78
1
0
0
1
1
1
0
270000–277FFF
SA79
1
0
0
1
1
1
1
278000–27FFFF
SA80
1
0
1
0
0
0
0
280000–287FFF
SA81
1
0
1
0
0
0
1
288000–28FFFF
SA82
1
0
1
0
0
1
0
290000–297FFF
SA83
1
0
1
0
0
1
1
298000–29FFFF
SA84
1
0
1
0
1
0
0
2A0000–2A7FFF
SA85
1
0
1
0
1
0
1
2A8000–2AFFFF
SA86
1
0
1
0
1
1
0
2B0000–2B7FFF
SA87
1
0
1
0
1
1
1
2B8000–2BFFFF
SA88
1
0
1
1
0
0
0
2C0000–2C7FFF
SA89
1
0
1
1
0
0
1
2C8000–2CFFFF
SA90
1
0
1
1
0
1
0
2D0000–2D7FFF
SA91
1
0
1
1
0
1
1
2D8000–2DFFFF
SA92
1
0
1
1
1
0
0
2E0000–2E7FFF
SA93
1
0
1
1
1
0
1
2E8000–2EFFFF
SA94
1
0
1
1
1
1
0
2F0000–2F7FFF
SA95
1
0
1
1
1
1
1
2F8000–2FFFFF
10000
10001
10010
10011
10100
10101
10110
10111
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
8
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Sector
Group
SG24
SG25
SG26
SG27
SG28
SG29
SG30
SG31
A21-A17
Sector
A21
A20
A19
A18
A17
A16
A15
Address Range
(hexadecimal)
SA96
1
1
0
0
0
0
0
300000–307FFF
SA97
1
1
0
0
0
0
1
308000–30FFFF
SA98
1
1
0
0
0
1
0
310000–317FFF
SA99
1
1
0
0
0
1
1
318000–31FFFF
SA100
1
1
0
0
1
0
0
320000–327FFF
SA101
1
1
0
0
1
0
1
328000–32FFFF
SA102
1
1
0
0
1
1
0
330000–337FFF
SA103
1
1
0
0
1
1
1
338000–33FFFF
SA104
1
1
0
1
0
0
0
340000–347FFF
SA105
1
1
0
1
0
0
1
348000–34FFFF
SA106
1
1
0
1
0
1
0
350000–357FFF
SA107
1
1
0
1
0
1
1
358000–35FFFF
SA108
1
1
0
1
1
0
0
360000–367FFF
SA109
1
1
0
1
1
0
1
368000–36FFFF
SA110
1
1
0
1
1
1
0
370000–377FFF
SA111
1
1
0
1
1
1
1
378000–37FFFF
SA112
1
1
1
0
0
0
0
380000–387FFF
SA113
1
1
1
0
0
0
1
388000–38FFFF
SA114
1
1
1
0
0
1
0
390000–397FFF
SA115
1
1
1
0
0
1
1
398000–39FFFF
SA116
1
1
1
0
1
0
0
3A0000–3A7FFF
SA117
1
1
1
0
1
0
1
3A8000–3AFFFF
SA118
1
1
1
0
1
1
0
3B0000–3B7FFF
SA119
1
1
1
0
1
1
1
3B8000–3BFFFF
SA120
1
1
1
1
0
0
0
3C0000–3C7FFF
SA121
1
1
1
1
0
0
1
3C8000–3CFFFF
SA122
1
1
1
1
0
1
0
3D0000–3D7FFF
SA123
1
1
1
1
0
1
1
3D8000–3DFFFF
SA124
1
1
1
1
1
0
0
3E0000–3E7FFF
SA125
1
1
1
1
1
0
1
3E8000–3EFFFF
SA126
1
1
1
1
1
1
0
3F0000–3F7FFF
SA127
1
1
1
1
1
1
1
3F8000–3FFFFF
11000
11001
11010
11011
11100
11101
11110
11111
Note: The sizes of all sectors are 32K-word.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
9
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
USER MODE DEFINITIONS
TABLE 3. BUS OPERATIONS
Operation
CE#
OE#
WE#
RESET#
WP#
ACC
A21-A0
DQ15-DQ0
Read
L
L
H
H
X
X
AIN
DOUT
Write
L
H
L
H
(Note 1)
X
AIN
Accelerated
Program
L
H
L
H
(Note 1)
VHH
Vcc ±
0.3V
X
X
Vcc ±
0.3V
X
H
X
High-Z
TTL Standby
H
X
X
H
X
H
X
High-Z
Output Disable
L
H
H
H
X
X
X
High-Z
Hardware Reset
X
X
X
L
X
X
X
High-Z
CMOS Standby
B
B
B
B
B
Sector Group
Protect
L
H
L
VID
H
X
Sector Group
Unprotect
L
H
L
VID
H
X
Temporary
Sector
Group
Unprotect
X
X
X
VID
H
X
B
B
B
B
B
B
B
B
B
(Note 3)
B
B
B
AIN
B
(Note 3)
B
B
B
SA,
A6=L,
A1=H,
A0=L
SA,
A6=H,
A1=H,
A0=L
AIN
B
B
B
(Note 3)
(Note 3)
(Note 3)
L=logic low= VIL, H=Logic High= VIH, VID = VHH = 11 ± 0.5V = 10.5 ─ 11.5V, X=Don’t Care (either
L or H, but not floating!), SA=Sector Addresses (A21-A15), DIN=Data In, DOUT=Data Out,
AIN=Address In
B
B
B
B
B
B
B
B
B
B
B
B
Notes:
1. If the system asserts VIL on the WP# pin, the device disables program and erase functions in
the first or last sector independent of whether those sectors were protected or unprotected; if
the system asserts VIH on the WP# pin, the device reverts to whether the first or last sector was
previously protected or unprotected. If ACC = VHH, all sectors will be unprotected.
B
B
B
B
2. Please refer to “Sector Group Protection & Unprotection”, Flowchart 6a and Flowchart 6b.
3. DIN or DOUT as required by command sequence, data polling, or sector protect algorithm.
Read Mode
The device is automatically set to reading array data after device power-up or hardware reset. No
commands are required to retrieve data. The device is also ready to read array data after completing an
Embedded Program or Embedded Erase algorithm
After the device accepts an Sector Erase Suspend command, the device enters the Sector Erase
Suspend mode. The system can read array data using the standard read timings, except that if it reads
at an address within erase-suspended sectors, the device outputs status data. After completing a
programming operation in the Sector Erase Suspend mode, the system may once again read array
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
10 ©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
data with the same exception. See “Sector Erase Suspend/Resume Commands” for more additional
information.
The system must issue the reset command to re-enable the device for reading array data if DQ5 goes
high or while in the autoselect mode. See the “Reset Command” for additional details.
Output Disable Mode
When the OE# pin is at a logic high level (VIH), the output from the device is disabled. The output pins
are placed in a high impedance state.
B
B
Standby Mode
The device has a CMOS-compatible standby mode, which reduces the current to < 1µA (typical). It is
placed in CMOS-compatible standby when the CE# pin is at VCC ± 0.5. RESET# and BYTE# pin must
also be at CMOS input levels. The device also has a TTL-compatible standby mode, which reduces the
maximum VCC current to < 1mA. It is placed in TTL-compatible standby when the CE# pin is at VIH.
When in standby modes, the outputs are in a high-impedance state independent of the OE# input.
B
B
B
B
B
B
B
Automatic Sleep Mode
The device has an automatic sleep mode, which minimizes power consumption. The devices will enter
this mode automatically when the states of address bus remain stable for tacc + 30ns. ICC4 in the DC
Characteristics table shows the current specification. With standard access times, the device will output
new data when addresses change.
Writing Command Sequences
To write a command or command sequence to program data to the device or erase data, the system
has to drive WE# and CE# to VIL, and OE# to VIH.
B
B
B
The device has an Unlock Bypass mode to facilitate faster programming. Once the device enters the
Unlock Bypass mode, only two write cycles are required to program a word, instead of four.
The system can also read the autoselect codes by entering the autoselect mode, which need the
autoselect command sequence to be written. Please refer to the “Command Definitions” for all the
available commands.
Autoselect Identification Mode
The autoselect mode provides manufacturer and device identification, and sector protection verification,
through identifier codes output on DQ15–DQ0. This mode is primarily intended for programming
equipment to automatically match a device to be programmed with its corresponding programming
algorithm. However, the autoselect codes can also be accessed in-system through the command
register.
When using programming equipment, the autoselect mode requires VID (10.5 V to 11.5 V) on address
pin A9. Address pins A6, A1, and A0 must be as shown in Autoselect Codes table. In addition, when
verifying sector group protection, the sector group address must appear on the appropriate highest
order address bits. Refer to the corresponding Sector Address Tables. The “Command Definitions”
table shows the remaining address bits that are don’t-care. When all necessary bits have been set as
required, the programming equipment may then read the corresponding identifier code on DQ15–DQ0.
B
B
To access the autoselect codes in-system; the host system can issue the autoselect command via the
command register, as shown in the Command Definitions table. This method does not require VID. See
“Command Definitions” for details on using the autoselect mode. Note that a Reset command is
required to return to read mode when the device is in the autoselect mode.
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
11 ©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
B
EN29LV641H/L EN29LV640U
TABLE 4. Autoselect Codes (Using High Voltage, VID)
B
Description
CE#
OE#
WE#
Manufacturer ID:
Eon
L
L
H
Autoselect
Device ID
L
A21
to
A15
A14
to
A10
A9
X
VID
2
P
P
A8
B
A7
A6
A5
to
A2
A1
A0
X
L
X
L
L
1
H
P
X
B
B
XX1Ch
P
L
L
H
X
X
VID
B
B
X
DQ15 to DQ0
XX7Fh
X
L
X
L
H
22D7h
XX01h
Sector Protection
Verification
L
L
H
SA
X
VID
B
B
X
X
L
X
H
L
(Protected)
XX00h
(Unprotected)
L=logic low= VIL, H=Logic High= VIH, VID =11 ± 0.5V, X=Don’t Care (either L or H, but not floating!), SA=Sector
Addresses
B
B
B
B
B
B
Note:
1. A8=H is recommended for Manufacturing ID check. If a manufacturing ID is read with A8=L, the chip will output a
configuration code 7Fh.
2. A9 = VID is for HV A9 Autoselect mode only. A9 must be ≤ Vcc (CMOS logic level) for Command Autoselect
Mode.
B
B
ACC: Accelerated Program Operation
The device offers accelerated program operation which enables the programming in higher speed.
When ACC is raised to VHH, the memory automatically enters the Unlock Bypass mode (please refer to
“Command Definitions”), temporarily unprotects every protected sector groups, and reduces the
time required for program operation. The system would use a two-cycle program command sequence
as required by the Unlock Bypass mode. When ACC returns to VIH or VIL, normal operation resumes.
The transitions from VIH or VIL to VHH and from VHH to VIH or VIL must be slower than tVHH, see Figure 5.
Note that the ACC pin must not be left floating or unconnected. In addition, ACC pin must not be at VHH
for operations other than accelerated program. It could cause the device to be damaged. Never raise
this pin to VHH from any mode except Read mode; otherwise the memory may be left in an
indeterminate state.
A 0.1µF capacitor should be connected between the ACC pin and the VSS Ground pin to decouple the
current surges from the power supply. The PCB track widths must be sufficient to carry the currents
required during Unlock Bypass Program.
RESET#: Hardware Reset
When RESET# is driven low for tRP, all output pins are tristates. All commands written in the internal
state machine are reset to reading array data.
B
B
Please refer to timing diagram for RESET# pin in “AC Characteristics”.
Sector Group Protection & Unprotection
The hardware sector group protection feature disables both program and erase operations in any sector
group. The hardware chip unprotection feature re-enables both program and erase operations in previously
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
12 ©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
protected sector group. A sector group consists of four adjacent sectors that would be protected at the
same time. Please see Table 2 which show the organization of sector groups.
There are two methods to enable this hardware protection circuitry. The first one requires only that the
RESET# pin be at VID and then standard microprocessor timings can be used to enable or disable this
feature. See Flowchart 6a and 6b for the algorithm and Figure 11 for the timings.
When doing Sector Group Unprotect, all the unprotected sector groups must be protected prior to any
unprotect write cycle.
The second method is for programming equipment. This method requires VID to be applied to both OE#
and A9 pins and non-standard microprocessor timings are used. This method is described in a
separate document, the Datasheet Supplement of EN29LV641H/L / EN29LV640U, which can be
obtained by contacting a representative of Eon Silicon Solution, Inc.
U
WP#: Write Protect
The Write Protect function provides a hardware method to protect the first or last sector against erase
and program without using VID.
When WP# is Low, the device protects the first or last sector regardless of whether these sectors were
previously protected or unprotected using the method described in “Sector Group Protection &
Unprotection”, Program and Erase operations in these sectors are ignored.
When WP# is High, the device reverts to the previous protection status of the first or last sector.
Program and Erase operations can now modify the data in those sectors unless the sector is protected
using Sector Group Protection.
Note that the WP# pin must not be left floating or unconnected.
Temporary Sector Group Unprotect
Start
This feature allows temporary unprotection of previously protected
sector groups to change data while in-system. The Temporary
Sector Group Unprotect mode is activated by setting the RESET#
pin to VBID.B During this mode, formerly protected sector groups can
be programmed or erased by simply selecting the sector group
addresses. Once VBIDB is removed from the RESET# pin, all the
previously protected sector groups are protected again. See
accompanying flowchart and timing diagrams in Figure 10 for more
details.
Notes:
1. All protected sector groups are unprotected. (If
WP#=VIL, the first or last sector will remain
protected.)
2. Previously protected sector groups are protected
again.
B
Reset#=VID (note 1)
B
B
B
B
Perform Erase or Program
Operations
RESET#=VIH
B
B
Temporary Sector Group
Unprotect Completed (note 2)
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
13 ©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
COMMON FLASH INTERFACE (CFI)
The common flash interface (CFI) specification outlines device and host systems software
interrogation handshake, which allows specific vendor-specified software algorithms to be used for
entire families of devices. Software support can then be device-independent, JEDEC IDindependent, and forward- and backward-compatible for the specified flash device families. Flash
vendors can standardize their existing interfaces for long-term compatibility.
This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to
address 55h, any time the device is ready to read array data.
The system can read CFI information at the addresses given in Tables 5-8.The upper address bits
(A7–MSB) must be all zeros. To terminate reading CFI data, the system must write the reset
command.
The system can also write the CFI query command when the device is in the autoselect mode. The
device enters the CFI query mode and the system can read CFI data at the addresses given in
Tables 5–8. The system must write the reset command to return the device to the autoselect mode.
Table 5. CFI Query Identification String
Addresses
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
Data
0051h
0052h
0059h
0002h
0000h
0040h
0000h
0000h
0000h
0000h
0000h
Description
Query Unique ASCII string “QRY”
Primary OEM Command Set
Address for Primary Extended Table
Alternate OEM Command set (00h = none exists)
Address for Alternate OEM Extended Table (00h = none exists)
Table 6. System Interface String
Addresses
1Bh
1Ch
1Dh
1Eh
1Fh
20h
21h
22h
23h
24h
25h
26h
Data
0027h
0036h
0000h
0000h
0003h
0000h
000Ah
0000h
0005h
0000h
0002h
0000h
Description
Vcc Min (write/erase)
DQ7-DQ4: volt, DQ3 –DQ0: 100 millivolt
Vcc Max (write/erase)
DQ7-DQ4: volt, DQ3 –DQ0: 100 millivolt
Vpp Min. voltage (00h = no Vpp pin present)
Vpp Max. voltage (00h = no Vpp pin present)
Typical timeout per single byte/word write 2N µS
Typical timeout for Min, size buffer write 2N µS (00h = not supported)
Typical timeout per individual block erase 2N ms
Typical timeout for full chip erase 2N ms (00h = not supported)
Max. timeout for byte/word write 2N times typical
Max. timeout for buffer write 2N times typical
Max. timeout per individual block erase 2N times typical
Max timeout for full chip erase 2N times typical (00h = not supported)
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Table 7. Device Geometry Definition
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
14 ©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Addresses
27h
28h
29h
2Ah
2Bh
2Ch
2Dh
2Eh
2Fh
30h
31h
32h
33h
34h
35h
36h
37h
38h
39h
3Ah
3Bh
3Ch
Data
0017h
0001h
0000h
0000h
0000h
0002h
0007h
0000h
0020h
0000h
007Eh
0000h
0000h
0001h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
Description
Device Size = 2N bytes
P
P
Flash Device Interface description (refer to CFI publication 100)
Max. number of byte in multi-byte write = 2N
(00h = not supported)
Number of Erase Block Regions within device
P
P
Erase Block Region 1 Information
(refer to the CFI specification of CFI publication 100)
Erase Block Region 2 Information
Erase Block Region 3 Information
Erase Block Region 4 Information
Table 8. Primary Vendor-specific Extended Query
Addresses
40h
41h
42h
43h
44h
Data
0050h
0052h
0049h
0031h
0033h
45h
0004h
46h
0002h
47h
0004h
48h
0001h
49h
0004h
4Ah
0000h
4Bh
0000h
4Ch
0000h
4Dh
00A5h
4Eh
00B5h
4Fh
00XXh
Description
Query-unique ASCII string “PRI”
Major version number, ASCII
Minor version number, ASCII
Address Sensitive Unlock
0 = Required, 1 = Not Required
Erase Suspend
0 = Not Supported, 1 = To Read Only, 2 = To Read & Write
Sector Protect
0 = Not Supported, X = Number of sectors in per group
Sector Temporary Unprotect
00 = Not Supported, 01 = Supported
Sector Protect/Unprotect scheme
01 = 29F040 mode, 02 = 29F016 mode,
03 = 29F400 mode, 04 = 29LV800A mode
Simultaneous Operation
00 = Not Supported, 01 = Supported
Burst Mode Type
00 = Not Supported, 01 = Supported
Page Mode Type
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page
Minimum ACC (Acceleration) Supply Voltage
00 = Not Supported, DQ7-DQ4 : Volts, DQ3-DQ0 : 100mV
Maximum ACC (Acceleration) Supply Voltage
00 = Not Supported, DQ7-DQ4 : Volts, DQ3-DQ0 : 100mV
00h = Uniform Sector Devices
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
15
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Hardware Data protection
The command sequence requirement of unlock cycles for programming or erasing provides data
protection against inadvertent writes as seen in the Command Definitions table. Additionally, the
following hardware data protection measures prevent accidental erasure or programming, which
might otherwise be caused by false system level signals during Vcc power up and power down
transitions, or from system noise.
Low VCC Write Inhibit
B
B
When VCC is less than VLKO, the device does not accept any write cycles. This protects data during
VCC power up and power down. The command register and all internal program/erase circuits are
disabled, and the device resets. Subsequent writes are ignored until VCC is greater than VLKO. The
system must provide the proper signals to the control pins to prevent unintentional writes when VCC
is greater than VLKO.
B
B
B
B
B
B
Write Pulse “Glitch” protection
Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.
Logical Inhibit
Write cycles are inhibited by holding any one of OE# = VIL, CE# = VIH, or WE# = VIH. To initiate a
write cycle, CE# and WE# must be a logical zero while OE# is a logical one. If CE#, WE#, and OE#
are all logical zero (not recommended usage), it will be considered a read.
B
B
B
B
B
B
Power-up Write Inhibit
During power-up, the device automatically resets to READ mode and locks out write cycles. Even
with CE# = VIL, WE#= VIL and OE# = VIH, the device will not accept commands on the rising edge of
WE#.
B
B
B
B
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
16
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
COMMAND DEFINITIONS
The operations of the device are selected by one or more commands written into the command
register. Commands are made up of data sequences written at specific addresses via the
command register. The sequences for the specified operation are defined in the Command
Definitions table (Table 9). Incorrect addresses, incorrect data values or improper sequences will
reset the device to Read Mode.
Table 9. EN29LV641H/L / EN29LV640U Command Definitions
Cycles
Bus Cycles (Note 1-2)
Command
Sequence
st
1 Cycle
P
P
Addr
Data
nd
2
rd
th
3 Cycle
4 Cycle
Cycle
Addr
Data
Addr
Data
Addr
P
P
P
P
P
P
Data
th
5 Cycle
P
P
th
6 Cycle
P
P
Addr
Data
Addr
Data
1
RA
RD
Reset
1
xxx
F0
Manufacturer ID
4
555
AA
2AA
55
555
90
000
100
7F
1C
Device ID
4
555
AA
2AA
55
555
90
X01
22D7
Sector Protect
Verify (Note 4)
4
555
AA
2AA
55
555
90
(SA)
X02
XX00
XX01
Program
4
555
AA
2AA
55
555
A0
PA
PD
Unlock Bypass
3
555
AA
2AA
55
555
20
Unlock Bypass
Program
2
XXX
A0
PA
PD
Unlock Bypass Reset
2
XXX
90
XXX
00
Chip Erase
6
555
AA
2AA
55
555
80
555
AA
2AA
55
555
10
Sector Erase
6
555
AA
2AA
55
555
80
555
AA
2AA
55
SA
30
Sector Erase Suspend
1
BA
B0
Sector Erase Resume
1
BA
30
CFI Query
1
55
98
Autoselect
Read (Note 3)
Address and Data values indicated are in hex. Unless specified, all bus cycles are write cycles
RA = Read Address: address of the memory location to be read. This is a read cycle.
RD = Read Data: data read from location RA during Read operation. This is a read cycle.
PA = Program Address: address of the memory location to be programmed. X = Don’t-Care
PD = Program Data: data to be programmed at location PA
SA = Sector Address: address of the Sector to be erased or verified (in Autoselect mode).
Address bits A21-A15 uniquely select any Sector.
Notes:
1. Data bits DQ15-DQ8 are don’t care in command sequences, except for RD and PD.
2. Unless otherwise noted, address bits A21-A15 are don’t cares.
3. No unlock or command cycles required when device is in read mode.
4. The data is 00h for an unprotected sector group and 01h for a protected sector group.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
17
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Reading Array Data
The device is automatically set to reading array data after power up. No commands are required to
retrieve data. The device is also ready to read array data after completing an Embedded Program or
Embedded Erase algorithm.
Following an Sector Erase Suspend command, Sector Erase Suspend mode is entered. The system
can read array data using the standard read timings from sectors other than the one which is being
erase-suspended. If the system reads at an address within erase-suspended sectors, the device
outputs status data. After completing a programming operation in the Sector Erase Suspend mode,
the system may once again read array data with the same exception.
The Reset command must be issued to re-enable the device for reading array data if DQ5 goes high
during an active program or erase operation or while in the autoselect mode. See next section for
details on Reset.
Reset Command
Writing the reset command to the device resets the device to reading array data. Address bits are
don’t-care for this command.
The reset command may be written between the cycle sequences in an erase command sequence
before erasing begins. This resets the device to reading array data. Once erasure begins, however,
the device ignores reset commands until the operation is complete. The reset command may be
written between the cycle sequences in a program command sequence before programming begins.
This resets the device to reading array data (also applies to programming in Sector Erase Suspend
mode). Once programming begins, however, the device ignores reset commands until the operation
is complete.
The reset command may be written between the cycle sequences in an autoselect command
sequence. Once in the autoselect mode, the reset command must be written to return to reading
array data.
If DQ5 goes high during a program or erase operation, writing the reset command returns the device
to reading array data (also applies in Sector Erase Suspend mode).
Autoselect Command Sequence
The autoselect command sequence allows the host system to access the manufacturer and devices
ID codes, and determine whether or not a sector group is protected. The Command Definitions table
shows the address and data requirements. This is an alternative to the method that requires VID on
address bit A9 and is intended for commercial programmers.
B
B
Two unlock cycles followed by the autoselect command initiate the autoselect command sequence.
Autoselect mode is then entered and the system may read at addresses shown in Table 9 any
number of times, without needing another command sequence.
The system must write the reset command to exit the autoselect mode and return to reading array
data.
Word Programming Command
Programming is performed by using a four-bus-cycle operation (two unlock write cycles followed by
the Program Setup command and Program Data Write cycle). When the program command is
executed, no additional CPU controls or timings are necessary. An internal timer terminates the
program operation automatically. Address is latched on the falling edge of CE# or WE#, whichever is
last; data is latched on the rising edge of CE# or WE#, whichever is first.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
18
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Any commands written to the device during the program operation are ignored. Programming status
can be checked by sampling data on DQ7 (DATA# polling) or on DQ6 (toggle bit). When the
program operation is successfully completed, the device returns to read mode and the user can read
the data programmed to the device at that address. Note that data can not be programmed from a
“0” to a “1”. Attempting to do so may halt the operation and set DQ5 to “1”, or cause the Data#
Polling algorithm to indicate the operation was successful. However, a succeeding read will show
that the data is still “0”. Only erase operations can convert a “0” to a “1”. When programming time
limit is exceeded, DQ5 will produce a logical “1” and a Reset command can return the device to
Read mode.
Programming is allowed in any sequence across sector boundaries.
Unlock Bypass
To speed up programming operation, the Unlock Bypass Command may be used. Once this feature
is activated, the shorter two-cycle Unlock Bypass Program command can be used instead of the
normal four-cycle Program Command to program the device. During the unlock bypass mode, only
the Unlock Bypass Program and Unlock Bypass Reset command can be accepted. This mode is
exited after issuing the Unlock Bypass Reset Command. The device powers up with this feature
disabled
The device provides accelerated program operations through the ACC pin. When ACC is asserted
to VHH, the device automatically enters the Unlock Bypass mode. The system may then write the
two-cycle Unlock Bypass Program command sequence.
B
B
Chip Erase Command
Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing
two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then
followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The
device does not require the system to preprogram prior to erase. The Embedded Erase algorithm
automatically preprograms and verifies the entire memory for an all zero data pattern prior to
electrical erase. The system is not required to provide any controls or timings during these
operations. The Command Definitions table shows the address and data requirements for the chip
erase command sequence.
Any commands written to the chip during the Embedded Chip Erase algorithm are ignored.
The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. See “Write
Operation Status” for information on these status bits. When the Embedded Erase algorithm is
complete, the device returns to reading array data and addresses are no longer latched.
Sector Erase Command Sequence
Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by
writing two un-lock cycles, followed by a set-up command. Two additional unlock write cycles are
then followed by the address of the sector to be erased, and the sector erase command. The
Command Definitions table shows the address and data requirements for the sector erase
command sequence.
Once the sector erase operation has begun, only the Erase Suspend command is valid. All other
commands are ignored. If there are several sectors to be erased, Sector Erase Command
sequences must be issued for each sector. That is, only a sector address can be specified for
each Sector Erase command. Users must issue another Sector Erase command for the next
sector to be erased after the previous one is completed.
When the Embedded Erase algorithm is complete, the device returns to reading array data and
addresses are no longer latched. The system can determine the status of the erase operation by
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
19
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
using DQ7, DQ6, or DQ2. Refer to “Write Operation Status” for information on these status bits.
Flowchart 4 illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations
tables in the “AC Characteristics” section for parameters, and to the Sector Erase Operations Timing
diagram for timing waveforms.
Sector Erase Suspend / Resume Command
The Sector Erase Suspend command allows the system to interrupt a sector erase operation and
then read data from, or program data to, any sector not selected for erasure. This command is valid
only during the sector erase operation. The Sector Erase Suspend command is ignored if written
during the chip erase operation or Embedded Program algorithm. Addresses are don’t-cares when
writing the Sector Erase Suspend command.
When the Sector Erase Suspend command is written during a sector erase operation, the device
requires a maximum of 20 µs to suspend the erase operation.
After the erase operation has been suspended, the system can read array data from or program
data to any sector not selected for erasure. Normal read and write timings and command definitions
apply. Please note that Autoselect command sequence can not be accepted during Sector
Erase Suspend.
Reading at any address within erase-suspended sectors produces status data on DQ7–DQ0. The
system can use DQ7, or DQ6 and DQ2 together, to determine if a sector is actively erasing or is
erase-suspended. See “Write Operation Status” for information on these status bits.
After an erase-suspended program operation is complete, the system can once again read array
data within non-suspended sectors. The system can determine the status of the program operation
using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation
Status” for more information. The Autoselect command is not supported during Sector Erase
Suspend Mode.
The system must write the Sector Erase Resume command (address bits are don’t-care) to exit the
sector erase suspend mode and continue the sector erase operation. Further writes of the Resume
command are ignored. Another Sector Erase Suspend command can be written after the device has
resumed erasing.
WRITE OPERATION STATUS
DQ7: DATA# Polling
The device provides DATA# polling on DQ7 to indicate the status of the embedded operations. The
DATA# Polling feature is active during the Programming, Sector Erase, Chip Erase, and Sector
Erase Suspend. (See Table 10)
When the embedded programming is in progress, an attempt to read the device will produce the
complement of the data written to DQ7. Upon the completion of the programming operation, an
attempt to read the device will produce the true data written to DQ7. DATA# polling is valid after the
rising edge of the fourth WE# or CE# pulse in the four-cycle sequence for program.
When the embedded Erase is in progress, an attempt to read the device will produce a “0” at the
DQ7 output. Upon the completion of the embedded Erase, the device will produce the “1” at the DQ7
output during the read cycles. For Chip Erase or Sector Erase, DATA# polling is valid after the rising
edge of the last WE# or CE# pulse in the six-cycle sequence.
DATA# Polling must be performed at any address within a sector that is being programmed or
erased and not a protected sector. Otherwise, DATA# polling may give an inaccurate result if the
address used is in a protected sector.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
20
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Just prior to the completion of the embedded operations, DQ7 may change asynchronously when
the output enable (OE#) is low. This means that the device is driving status information on DQ7 at
one instant of time and valid data at the next instant of time. Depending on the time the system
samples the DQ7 output, it may read the status of valid data. Even if the device has completed the
embedded operation and DQ7 has a valid data, the data output on DQ0-DQ6 may be still invalid.
The valid data on DQ0-DQ7 should be read on the subsequent read attempts.
The flowchart for DATA# Polling (DQ7) is shown on Flowchart 4. The DATA# Polling (DQ7) timing
diagram is shown in Figure 6.
RY/BY#: Ready/Busy Status output
The RY/BY# is a dedicated, open-drain output pin that indicates whether an Embedded Algorithm is
in progress or completed. The RY/BY# status is valid after the rising edge of the final WE# pulse in
the command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied
together in parallel with a pull-up resistor to VCC.
In the output-low period, signifying Busy, the device is actively erasing or programming. This
includes programming in the Erase Suspend mode. If the output is high, signifying the Ready, the
device is ready to read array data (including during the Erase Suspend mode), or is in the standby
mode.
DQ6: Toggle Bit I
The device provides a “Toggle Bit” on DQ6 to indicate the status of the embedded programming and
erase operations. (See Table 10)
During an embedded Program or Erase operation, successive attempts to read data from the device
at any address (by active OE# or CE#) will result in DQ6 toggling between “zero” and “one”. Once
the embedded Program or Erase operation is completed, DQ6 will stop toggling and valid data will
be read on the next successive attempts. During Programming, the Toggle Bit is valid after the rising
edge of the fourth WE# pulse in the four-cycle sequence. During Erase operation, the Toggle Bit is
valid after the rising edge of the sixth WE# pulse for sector erase or chip erase.
In embedded programming, if the sector being written to is protected, DQ6 will toggles for about 2 µs,
then stop toggling without the data in the sector having changed. In Sector Erase or Chip Erase, if all
selected sectors are protected, DQ6 will toggle for about 100 µs. The chip will then return to the read
mode without changing data in all protected sectors.
The flowchart for the Toggle Bit (DQ6) is shown in Flowchart 5. The Toggle Bit timing diagram is
shown in Figure 7.
DQ5: Exceeded Timing Limits
DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count
limit. Under these conditions DQ5 produces a “1.” This is a failure condition that indicates the
program or erase cycle was not successfully completed. Since it is possible that DQ5 can become a
1 when the device has successfully completed its operation and has returned to read mode, the user
must check again to see if the DQ6 is toggling after detecting a “1” on DQ5.
The DQ5 failure condition may appear if the system tries to program a “1” to a location that is
previously programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under
this condition, the device halts the operation, and when the operation has exceeded the timing limits,
DQ5 produces a “1.” Under both these conditions, the system must issue the reset command to
return the device to reading array data.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
21
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
DQ3: Sector Erase Timer
After writing a sector erase command sequence, the output on DQ3 can be checked to determine
whether or not an erase operation has begun. (The sector erase timer does not apply to the chip
erase command.) When sector erase starts, DQ3 switches from “0” to “1”. This device does not
support multiple sector erase (continuous sector erase) command sequences so it is not very
meaningful since it immediately shows as a “1” after the first 30h command. Future devices may
support this feature.
DQ2: Erase Toggle Bit II
The “Toggle Bit” on DQ2, when used with DQ6, indicates whether a particular sector is actively
erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erasesuspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command
sequence. DQ2 toggles when the system reads at addresses within those sectors that have been
selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2
cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6, by
comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot
distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and
mode information. Refer to the following table to compare outputs for DQ2 and DQ6.
Flowchart 6 shows the toggle bit algorithm, and the section “DQ2: Toggle Bit” explains the algorithm.
See also the “DQ6: Toggle Bit I” subsection. Refer to the Toggle Bit Timings figure for the toggle bit
timing diagram. The DQ2 vs. DQ6 figure shows the differences between DQ2 and DQ6 in graphical
form.
Reading Toggle Bits DQ6/DQ2
Refer to Flowchart 5 for the following discussion. Whenever the system initially begins reading
toggle bit status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is
toggling. Typically, a system would note and store the value of the toggle bit after the first read. After
the second read, the system would compare the new value of the toggle bit with the first. If the
toggle bit is not toggling, the device has completed the program or erase operation. The system can
read array data on DQ7–DQ0 on the following read cycle.
However, after the initial two read cycles, the system determines that the toggle bit is still toggling.
And the system also should note whether the value of DQ5 is high (see the section on DQ5). If it is,
the system should then determine again whether the toggle bit is toggling, since the toggle bit may
have stopped toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has
successfully completed the program or erase operation. If it is still toggling, the device did not
complete the operation successfully, and the system must write the reset command to return to
reading array data.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
22
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Write Operation Status
Operation
Standard
Mode
Sector
Erase
Suspend
Mode
DQ7
DQ6
DQ5
DQ3
DQ2
RY/BY#
Embedded Program
Algorithm
DQ7#
Toggle
0
N/A
No
toggle
0
Embedded Erase Algorithm
0
Toggle
0
1
Toggle
0
1
No
Toggle
0
N/A
Toggle
1
Data
Data
Data
Data
Data
1
DQ7#
Toggle
0
N/A
N/A
0
Reading within Erase
Suspended Sector
Reading within Non-Erase
Suspended Sector
Erase-Suspend Program
Table 10. Status Register Bits
DQ
Name
Logic Level
‘1’
7
DATA#
POLLING
‘0’
DQ7
DQ7#
‘-1-0-1-0-1-0-1-’
6
TOGGLE BIT
DQ6
‘-1-1-1-1-1-1-1-‘
5
3
2
ERROR BIT
SECTOR
ERASE TIME
BIT
TOGGLE BIT
Definition
Erase Complete or erased sector in Sector Erase
Suspend
Erase On-Going
Program Complete or data of non-erased sector
during Sector Erase Suspend
Program On-Going
Erase or Program On-going
Read during Sector Erase Suspend
Erase Complete
‘1’
Program or Erase Error
‘0’
Program or Erase On-going
‘1’
Erase operation start
‘0’
Erase timeout period on-going
‘-1-0-1-0-1-0-1-’
DQ2
Chip Erase, Sector Erase or Read within EraseSuspended sector. (When DQ5=1, Erase Error due
to currently addressed Sector or Program on
Erase-Suspended sector
Read on addresses of non Erase-Suspend sectors
Notes:
DQ7: DATA# Polling: indicates the P/E status check during Program or Erase, and on completion before checking bits DQ5
for Program or Erase Success.
DQ6: Toggle Bit: remains at constant level when P/E operations are complete or erase suspend is acknowledged.
Successive reads output complementary data on DQ6 while programming or Erase operation are on-going.
DQ5: Error Bit: set to “1” if failure in programming or erase
DQ3: Sector Erase Command Timeout Bit: Operation has started. Only possible command is Erase suspend (ES).
DQ2: Toggle Bit: indicates the Erase status and allows identification of the erased Sector.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
23
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
EMBEDDED ALGORITHMS
Flowchart 1. Embedded Chip Erase
START
Write Data AAh to Address 555h
Write Data 55h to Address 2AAh
Write Data 80h to Address 555h
Write Data AAh to Address 555h
Write Data 55h to Address 2AAh
Write Data 10h to Address 555h
Data Poll from System
No
DATA = FFh?
Embedded
Chip Erase
in progress
Yes
Erasure Completed
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
24
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Flowchart 2. Embedded Sector Erase
START
Write Data AAh to Address 555h
Write Data 55h to Address 2AAh
Write Data 80h to Address 555h
Write Data AAh to Address 555h
Write Data 55h to Address 2AAh
Write Data 30h to Sector Address
Data Poll from System
DATA = FFh?
No
Embedded
Sector Erase
in progress
Yes
No
Last Sector to Erase?
Yes
Erasure Completed
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
25
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Flowchart 3. Embedded Program
START
Write Data AAh to Address 555h
Write Data 55h to Address 2AAh
Write Data A0h to Address 555h
Write Programmed Data to Destination Address
Data Poll from System
No
Verify OK?
Embedded
Program
in progress
Yes
Increment Address
No
Last Address?
Yes
Program Completed
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
26
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Flowchart 4. DATA# Polling Algorithm
Start
Read DQ7-DQ0
Adr = VA
DQ7 = Data?
Yes
No
No
DQ5 = 1?
Notes:
1. VA = Valid address for programming.
During a sector erase operation, a valid
address is any sector address within the
sector being erased. During chip erase, a
valid address is any non-protected sector
address.
2. DQ7 should be re-checked even if DQ5 =
“1” in case the first set of reads was done
at the exact instant when the status data
was in transition.
Yes
Read DQ7-DQ0
Adr = VA
Yes
DQ7 = Data?
No
Fail
Pass
Flowchart 5. Toggle Bit Algorithm
Start
Read DQ7-DQ0 twice
No
DQ6 = Toggle?
Yes
No
DQ5 = 1?
Yes
Notes:
1. The system should be re-checked the toggle
bit even if DQ5 = “1” in case the first set of
reads was done at the exact instant when
the status data was in transition.
Read DQ7-DQ0
No
DQ6 = Toggle?
Yes
Fail
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
27
Pass
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Flowchart 6a. In-System Sector Group Protect Flowchart
START
PLSCNT = 1
RESET# = VID
Wait 1 µs
Temporary Sector
Group Unprotect Mode
No
First Write
Cycle =
60h?
Yes
Set up sector
group address
To Protect: Write 60h to
sector group addr with
A6 = 0, A1 = 1, A0 = 0
Wait 150 µs
To Verify: Write 40h to
sector group address
with
A6 = 0, A1 = 1, A0 = 0
Increment
PLSCNT
Reset
PLSCNT = 1
Wait 0.4 µs
Read from sector
address with
A6 = 0, A1 = 1, A0
No
PLSCNT = 25?
No
Data = 01h?
Yes
Yes
Device failed
Protect another
sector?
Yes
No
Remove VID
from RESET#
Write reset
command
Sector Group Protect Algorithm
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Sector Group
Protect complete
28
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Flowchart 6b. In-System Sector Group Unprotect Flowchart
START
PLSCNT = 1
Protect all sector
groups: The
indicated portion of
the sector group
protect algorithm
must be performed
for all unprotected
sectors prior to
issuing the first
sector unprotect
address (see
Diagram 6a.)
RESET# = VID
Wait 1 µS
No
Temporary Sector
Group Unprotect Mode
First Write
Cycle = 60h?
Yes
No
All sectors
protected?
Yes
Set up first sector
group address
Unprotect: Write 60H to sector
address with A6 = 1,
A1 = 1, A0 = 0
Wait 15 ms
Verify Unprotect: Write 40h
to sector address with A6 =
1, A1 = 1, A0 =0
Increment
PLSCNT
Wait 0.4 µS
No
PLSCCNT =
1000?
Read from sector group address
with A6 = 1, A1 = 1, A0 = 0
No
Yes
Yes
Device failed
Set up next sector
group address
Data = 00h?
Last sector
group
verified?
No
Yes
Remove VID from
RESET#
Write reset
command
Sector Group
Unprotect complete
Sector Group Unprotect Algorithm
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
29
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
ABSOLUTE MAXIMUM RATINGS
Parameter
Value
Unit
Storage Temperature
-65 to +125
°C
Plastic Packages
-65 to +125
°C
Ambient Temperature
With Power Applied
-55 to +125
°C
200
mA
VCC
-0.5 to 4.0
V
VIO
-0.5 to 5.5
V
-0.5 to +11.5
V
0.5 to VCC + 0.5
V
Output Short Circuit Current1
P
Voltage with
Respect to Ground
P
A9, OE#, ACC and
RESET# 2
P
P
All other pins 3
P
P
Notes:
1.
No more than one output shorted at a time. Duration of the short circuit should not be greater than one second.
2.
Minimum DC input voltage on A9, OE#, RESET# and WP#/ACC pins is –0.5V. During voltage transitions, A9, OE#,
RESET# and WP#/ACC pins may undershoot Vss to –1.0V for periods of up to 50ns and to –2.0V for periods of up to 20ns.
See figure below. Maximum DC input voltage on A9, OE#, and RESET# is 11.5V which may overshoot to 12.5V for periods
up to 20ns.
3.
Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, inputs may undershoot Vss to –1.0V for
periods of up to 50ns and to –2.0 V for periods of up to 20ns. See figure below. Maximum DC voltage on output and I/O
pins is Vcc + 0.5 V. During voltage transitions, outputs may overshoot to Vcc + 1.5 V for periods up to 20ns. See figure
below.
4.
Stresses above the values so mentioned above may cause permanent damage to the device. These values are for a stress
rating only and do not imply that the device should be operated at conditions up to or above these values. Exposure of the
device to the maximum rating values for extended periods of time may adversely affect the device reliability.
B
B
B
B
B
B
RECOMMENDED OPERATING RANGES1
P
Operating Supply Voltage
VCC
B
P
Parameter
Ambient Operating Temperature
Commercial Devices
Industrial Devices
B
Value
Unit
0 to 70
-40 to 85
Full Voltage Range:2.7 to
3.6V
Regulated Voltage Range:3.0
to 3.6V
°C
V
1.Recommended Operating Ranges define those limits between which the functionality of the device is guaranteed.
Maximum Negative Overshoot
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Maximum Positive Overshoot
30
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Waveform
Waveform
DC Characteristics
Table 11. DC Characteristics
Symbol
ILI
B
Parameter
Test Conditions
Max
Unit
0V≤ VIN ≤ VCC
±5
µA
A9 = 11.5V
35
µA
0V≤ VOUT ≤ VCC
±5
µA
9
16
mA
20
30
mA
1
5.0
µA
1
5.0
mA
1
5.0
uA
Input Leakage Current
B
B
ILIT
A9, ACC Input Load Current
ILO
Output Leakage Current
B
B
B
B
B
B
B
CE# = VIL ; OE# =
B
B
VIH ; f = 5MHZ
B
B
CE# = VIL, OE# =
B
ICC2
Supply Current (Program or Erase)
B
B
Supply Current (Standby - CMOS)
ICC3
B
ICC4
B
B
B
B
RESET# = VSS ± 0.3V
Reset Current
B
B
VIH , WE# = VIL
CE# = BYTE# =
RESET# = VCC ±
0.3V
(Note 1)
B
Typ
B
B
Supply Current (read)
ICC1
Min
VIH = VCC ± 0.3V
B
ICC5
B
VIL = VSS ± 0.3V,
Automatic Sleep Mode
B
B
B
B
WP# = VIH
B
VIL
B
Input Low Voltage
B
Input High Voltage
VIH
B
B
Voltage for ACC Program Acceleration
Voltage for Autoselect or Temporary
Sector Unprotect
Output Low Voltage
VHH
B
B
VID
B
B
VOL
B
B
B
B
B
B
V
V
10.5
11.5
V
10.5
11.5
V
0.45
V
B
IOH = -2.0 mA
Output High Voltage CMOS
IOH = -100 µA,
B
B
B
VLKO
0.8
Vcc ±
0.3
IOL = 4.0 mA
Output High Voltage TTL
VOH
-0.5
0.7 x
VCC
B
B
Supply voltage (Erase and Program
lock-out)
0.85 x
VCC
VCC 0.4V
2.3
V
V
2.5
Notes:
1. Maximum ICC specifications are tested with VCC = VCC max.
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
31
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
V
EN29LV641H/L EN29LV640U
Test Conditions
3.3 V
2.7 kΩ
Device under Test
CL
6.2 kΩ
Note: Diodes are IN3064 or equivalent
Test Specifications
Test Conditions
70R
Output Load
90
Unit
1 TTL Gate
Output Load Capacitance, CL
B
30
30
pF
5
5
ns
0.0-3.0
0.0-3.0
V
1.5
1.5
V
0.5VIO
0.5VIO
V
B
Input Rise and Fall times
Input Pulse Levels
Input timing measurement reference levels
Output timing measurement reference levels
.
Key to Switching Waveforms
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
32
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
AC CHARACTERISTICS
Table 13. Read-only Operations Characteristics
Parameter Symbols
Standard
Description
tAVAV
tRC
Read Cycle Time
B
B
B
tAVQV
B
B
tACC
B
B
70R
90
Unit
Min
70
90
ns
Max
70
90
ns
Max
70
90
ns
Output Enable to Output Delay
Max
30
35
ns
CE# = VIL
OE# = VIL
B
Address to Output Delay
B
B
tELQV
B
tCE
B
B
Chip Enable To Output Delay
B
Speed Options
Test
Setup
JEDEC
B
B
B
B
OE# = VIL
B
B
B
B
B
tGLQV
tOE
tEHQZ
tDF
Chip Enable to Output High Z
Max
20
20
ns
tGHQZ
tDF
Output Enable to Output High Z
Max
20
20
ns
tAXQX
tOH
Output Hold Time from
Addresses, CE# or OE#,
whichever occurs first
Min
0
0
ns
Read
Min
0
0
ns
Toggle and
Data# Polling
Min
10
10
ns
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
tOEH
B
B
Output Enable
Hold Time
Figure 2. AC Waveforms for READ Operations
tRC
Addresses Stable
Addresses
tACC
CE#
tDF
tOE
OE#
tOEH
WE#
tCE
tOH
Outputs
Output Valid
HIGH Z
Reset#
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
33
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
AC CHARACTERISTICS
Hardware Reset (RESET#)
Table 12. Hardware Reset Operations Characteristics
Parameter
Description
All Speed options
Uni
t
tREADY
RESET# Pin Low to Read or Write
Embedded Algorithms
Max
20
µs
tREADY
RESET# Pin Low to Read or Write
Non Embedded Algorithms
Max
500
nS
RESET# Pulse Width
Min
500
nS
RESET# High Time Before Read
Min
50
nS
B
B
B
B
tRP
B
B
tRH
B
B
Figure 1. AC Waveforms for RESET#
Reset# Timings
CE#
OE#
tRH
RESET#
tRP
tREADY
Reset Timings NOT During Automatic Algorithms
tREADY
CE#
OE#
RESET#
tRP
tRH
Reset Timings during Automatic Algorithms
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
34
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
AC CHARACTERISTICS
Table 14. Write (Erase/Program) Operations
Parameter
Symbols
Speed Options
JEDEC
Standard
tAVAV
tWC
B
B
tWLAX
B
90
ns
Address Setup Time
Min
0
0
ns
tAH
Address Hold Time
Min
40
40
ns
tDS
Data Setup Time
Min
40
40
ns
Data Hold Time
Min
0
0
ns
Min
20
20
ns
Min
0
0
ns
CE# Setup Time
Min
0
0
ns
CE# Hold Time
Min
0
0
ns
Write Pulse Width
Min
30
30
ns
Write Pulse Width High
Min
25
25
ns
Programming Operation
Typ
8
8
µs
Accelerated Programming
Operation
Typ
5
5
µs
Sector Erase Operation
Typ
0.5
0.5
s
Chip Erase Operation
Typ
64
64
s
tVHH
VHH Rise and Fall Time
Min
250
250
ns
tVCS
VCC Setup Time
Min
50
50
µs
B
B
B
B
B
B
B
B
tWHDX
B
tDH
B
B
B
B
Output Enable Hold Time
during Toggle and DATA#
Polling
Read Recovery Time before
Write (OE# High to WE# Low)
tOEH
B
tGHWL
B
tELWL
B
B
tGHWL
B
B
B
B
B
tCH
B
B
B
tWLWH
tWP
tWHDL
tWPH
B
B
B
B
B
B
tWHWH1
B
B
tWHWH1
B
B
tWHWH2
B
tWHWH1
B
B
B
B
B
tWHWH2
B
tWHWH3
B
B
tWHWH1
B
B
tCS
B
tWHEH
Unit
70
B
tDVWH
90
Min
B
tAS
B
70R
Write Cycle Time
B
tAVWL
Description
tWHWH3
B
B
B
B
B
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
35
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
AC CHARACTERISTICS
Table 15. Write (Erase/Program) Operations
Alternate CE# Controlled Writes
Parameter
Symbols
Speed Options
JEDEC
Standard
tAVAV
tWC
tAVEL
tAS
tELAX
70R
90
Unit
Write Cycle Time
Min
70
90
ns
Address Setup Time
Min
0
0
ns
tAH
Address Hold Time
Min
40
40
ns
tDVEH
tDS
Data Setup Time
Min
40
40
ns
tEHDX
tDH
Data Hold Time
Min
0
0
ns
tGHEL
tGHEL
Read Recovery Time before
Write (OE# High to CE# Low)
Min
0
0
ns
WE# Setup Time
Min
0
0
ns
WE# Hold Time
Min
0
0
ns
CE# Pulse Width
Min
35
45
ns
CE# Pulse Width High
Min
20
20
ns
Programming Operation
Typ
8
8
µs
Accelerated Programming
Operation
Typ
5
5
µs
Sector Erase Operation
Typ
0.5
0.5
s
B
B
B
B
B
B
B
B
B
B
B
B
B
B
tWS
B
tEHWH
B
B
B
B
tWLEL
B
B
B
B
B
B
B
B
tWH
B
B
B
tCP
tEHEL
tCPH
B
B
B
B
tWHWH1
B
B
B
B
tWHWH1
B
tWHWH1
B
B
B
B
B
tWHWH1
B
tWHWH2
B
B
tELEH
B
B
Description
tWHWH2
B
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
36
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
AC CHARACTERISTICS
Figure 3. AC Waveforms for Chip/Sector Erase Operations Timings
Erase Command Sequence (last 2 cycles)
Addresses
tWC
tAS
0x2AA
SA
Read Status Data (last two cycles)
tAH
VA
VA
0x555 for chip
erase
CE#
TGHWL
OE#
tCH
tWP
WE#
tCS
tWPH
tWHWH2 or tWHWH3
Data
0x55
tDS
0x30
tDH
Status
tBUSY
DOUT
tRB
RY/BY#
VCC
tVCS
Notes:
1. SA=Sector Address (for sector erase), VA=Valid Address for reading status, Dout =true data at read address.
2. Vcc is shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command
sequence.
B
B
B
B
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
37
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Figure 4. Program Operation Timings
Program Command Sequence (last 2 cycles)
Addresses
tWC
tAS
0x555
PA
Program Command Sequence (last 2 cycles)
tAH
PA
PA
CE#
tGHWL
OE#
tCH
tWP
WE#
tWPH
tWHWH1
tCS
Data
PD
OxA0
Status
DOUT
tDS
tRB
tBUSY
tDH
RY/BY#
tVCS
VCC
Notes:
1. PA=Program Address, PD=Program Data, DOUT is the true data at the program address.
2. VCC shown in order to illustrate tVCS measurement references. It cannot occur as shown during a valid
command sequence.
B
B
B
B
B
B
Figure 5. Accelerated Program Timing Diagram
VHH
B
B
ACC
0 or 3 V
0 or 3 V
tVHH
B
tVHH
B
B
B
CE#
WE#
tRSP
B
B
AC CHARACTERISTICS
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
38
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Figure 6. AC Waveforms for /DATA Polling During Embedded Algorithm
Operations
tRC
Addresses
VA
VA
VA
tACC
tCH
tCE
CE#
tOE
OE#
tOEH
tDF
WE#
tOH
Complement
Complement
DQ[7]
DQ[6:0]
Status
Data
Status Data
True
Valid Data
True
Valid Data
TBUSY
RY/BY#
Notes:
1. VA = Valid Address for reading Data# Polling status data
2. This diagram shows the first status cycle after the command sequence, the last status read cycle and the array data read cycle.
Figure 7. AC Waveforms for Toggle Bit During Embedded Algorithm
Operations
tRC
Addresses
VA
VA
VA
VA
tACC
tCH
tCE
CE#
tOE
OE#
tOEH
WE#
tDF
tOH
Valid Status
DQ6, DQ2
tBUSY
(first read)
Valid Status
(second
d)
Valid Status
Valid Data
(stops toggling)
RY/BY#
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
39
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Figure 8. Alternate CE# Controlled Write Operation Timings
PA for Program
SA for Sector Erase
0x555 for Chip Erase
0x555 for Program
0x2AA for Erase
Addresses
VA
tAS
tWC
tAH
WE#
tWH
tGHEL
OE#
tCP
tCPH
tWS
tCWHWH1 / tCWHWH2 / tCWHWH3
CE#
tDS
tBUSY
tDH
Data
Status
DOUT
PD for Program
0x30 for Sector Erase
0x10 for Chip Erase
0xA0 for
Program
RY/BY#
tRH
Reset#
Notes:
PA = address of the memory location to be programmed.
PD = data to be programmed at byte address.
VA = Valid Address for reading program or erase status
Dout = array data read at VA
Shown above are the last two cycles of the program or erase command sequence and the last status read cycle
RESETt# shown to illustrate tRH measurement references. It cannot occur as shown during a valid command
sequence.
B
B
B
B
Figure 9. DQ2 vs. DQ6
Enter
Embedded
Erase
WE#
Enter Erase
Suspend
Program
Erase
Suspend
Erase
Enter
Suspend
Read
Erase
Resume
Enter
Suspend
Program
Erase
Suspend
Read
Erase
DQ6
DQ2
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
40
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
Erase
Complete
EN29LV641H/L EN29LV640U
AC CHARACTERISTICS
Temporary Sector Group Unprotect
Parameter
Std
Description
tVIDR
VID Rise and Fall Time
VHH Rise and Fall Time
RESET# Setup Time for Temporary
Sector Unprotect
B
tVIHH
B
B
B
B
B
tRSP
B
B
B
B
Speed Option
70R
90
Unit
Min
500
Ns
Min
500
Ns
Min
4
µs
Figure 10. Temporary Sector Group Unprotect Timing Diagram
VID
RESET#
0 or 3 V
0 or 3 V
tVIDR
tVIDR
CE#
WE#
tRSP
AC CHARACTERISTICS
Figure 11. Sector Group Protect and Unprotect Timing Diagram
VID
RESET#
Vcc
0V
0V
tVIDR
tVIDR
SA,
A6,A1,A0
Data
60h
Valid
Valid
Valid
60h
40h
Status
Sector Protect/Unprotect
Verify
CE#
>0.4µS
WE#
>1µS
Protect: 150 uS
Unprotect: 15 mS
OE#
Notes:
Use standard microprocessor timings for this device for read and write cycles.
For Sector Group Protect, use A6=0, A1=1, A0=0. For Sector Group Unprotect, use A6=1, A1=1, A0=0.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
41
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
ERASE AND PROGRAM PERFORMANCE
Typ
Limits
Max
Unit
Sector Erase Time
0.5
10
Sec
Chip Erase Time
64
Word Programming Time
8
300
µS
Accelerated Word Program Time
5
120
µS
Chip Programming Time
20
60
Sec
Parameter
Erase/Program Endurance
Comments
Excludes 00h programming prior to
erasure
Sec
100K
Excludes system level overhead
Minimum 100K cycles
Cycles
Note: Typical Conditions are room temperature, 3V and checkboard pattern programmed.
LATCH UP CHARACTERISTICS
Parameter Description
Min
Max
Input voltage with respect to Vss on all pins except I/O pins
(including A9, Reset and OE#)
-1.0 V
12.0 V
Input voltage with respect to Vss on all I/O Pins
-1.0 V
VCC + 1.0 V
VCC Current
-100 mA
100 mA
B
B
B
B
Note: These are latch up characteristics and the device should never be put under these conditions. Refer to
Absolute Maximum ratings for the actual operating limits.
48-PIN TSOP PACKAGE CAPACITANCE
Parameter Symbol
Parameter Description
Test Setup
Typ
Max
Unit
Input Capacitance
VIN = 0
6
7.5
pF
COUT
Output Capacitance
VOUT = 0
8.5
12
pF
CIN2
Control Pin Capacitance
VIN = 0
7.5
9
pF
CIN
B
B
B
B
B
B
B
B
B
B
B
B
Note: Test conditions are Temperature = 25°C and f = 1.0 MHz.
DATA RETENTION
Parameter Description
Test Conditions
Min
Unit
150°C
10
Years
125°C
20
Years
Minimum Pattern Data Retention Time
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
42
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
FIGURE 12. TSOP 12mm x 20mm
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
43
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
44
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
FIGURE 13. 63-TFBGA 11mm x 12mm package outline
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
45
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27
EN29LV641H/L EN29LV640U
Revisions History
Revision No
Description
Date
A
Initial Release
1. VIO input should be tied to VCC only not supporting to 1.8V output
2. revise the package code for 63 balls TFBGA from “B” to “W” at
2005/02/21
B
page 5
3. a typo at tOE specification at page 2 and page 33, it shall be 30 ns
2005/06/27
and 35ns for 70R ns and 90ns product respectively.
4. Icc3 stand by current only reserves the CMOS condition
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
46
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
Rev. B, Issue Date: 2005/06/27