CUI EPS090066 Switching power supply Datasheet

date 09/2010
page 1 of 4
a division of CUI INC
SERIES:
DESCRIPTION:
6 W WALL PLUG
SWITCHING POWER SUPPLY
FEATURES
•Level V (efficient design)
•100 ~ 130 V ac input voltage
•regulated output voltage
•short circuit, over load protection
•meets EISA / efficiency level IV regulations
•custom designs available
RoHS
MODEL
output voltage
output wattage
ripple*
nominal
(V dc)
output current
min
(A)
max
(A)
max
(W)
max.
(mVp-p)
efficiency level
cord length
EPS030100
3
0
1
3
100
IV
1800 ±100
EPS033100
3.3
0
1
3.3
100
IV
1800 ±100
EPS036100
3.6
0
1
3.6
100
IV
1800 ±100
EPS045100
4.5
0
1
4.5
100
V
1800 ±100
EPS050100
5
0
1
5
100
V
1800 ±100
EPS060100
6
0
1
6
100
V
1800 ±100
EPS075080
7.5
0
0.8
6
100
V
1800 ±100
EPS090066
9
0
0.66
6
100
V
1800 ±100
EPS100060
10
0
0.6
6
100
V
1800 ±100
EPS120050
12
0
0.5
6
120
V
1800 ±100
EPS135044
13.5
0
0.44
6
135
V
1800 ±100
EPS150040
15
0
0.4
6
150
V
1800 ±100
EPS180033
18
0
0.33
6
180
V
1800 ±100
EPS240025
24
0
0.25
6
240
IV
1800 ±100
(mm)
*at full load, 100 ~ 130 V ac input, measured at 20MHz bandwidth with a 10 uF electrolytic cap and a 0.1 uF ceramic cap on the output
PART NUMBER KEY
EPS030100 - PXXXX - SZ - CXX
Base Number
Reserved for
custom orders
example of 3 V dc, 1 A
DC Plug type:
see output plug options
on page 4
20050 SW 112th Ave. Tualatin, Oregon 97062
Factory
Designation
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com
date 09/2010
page 2 of 4
a division of CUI INC
SERIES:
6 W WALL PLUG
DESCRIPTION:
SWITCHING POWER SUPPLY
INPUT
parameter
conditions/description
rated input voltage
min
nom
max
units
100
120
130
V ac
rated frequency
50
60
Hz
frequency range
47
63
Hz
inrush current
120 V ac, inrush lasts no longer than 0.5 ms before
settling to steady state current
40
A
no load power consumption
Input: 100 ~ 120 V ac
0.5
W
max
units
OUTPUT
parameter
conditions/description
min
line regulation
load regulation
nom
±2
full load to no load, > 5 V
full load to no load, < 5 V
%
±5
-5%
over/undershoot
at turn-on and turn-off
temp. coefficient
0 ~ 40°C, full load, after initial 1 hour warm-up
start-up time
time needed to reach regulation
%
+0.25 V
0
%
±0.02
%/°C
3
10
s
hold-up time
at 115 V ac, full load
output power limit
primary power limited
ms
overload protection
Fold-back current limiting starts at 105 ~ 160% of the rated output current. Auto-recovery. Long term
exposure to overload condition may reduce product reliability.
short circuit protection
Continuous, auto-recovery upon removal of short
SAFETY & EMI
parameter
conditions/description
min
HI-POT
input to output at 10 mA for 1 second
insulation resistance
input to output at 500 V dc
safety approvals
UL/cUL 1310
EMI standard
FCC part 15 class B
leakage current
at 120 V ac
RoHS compliant
yes
class 2 power supply
yes
nom
max
units
3000
V ac
100
M
0.5
mA
max
units
40
°C
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
nom
0
operating humidity
10
90
%
storage temperature
-20
85
°C
storage humidity
10
90
%
max
units
RELIABILITY
parameter
conditions/description
MTBF
at 25°C, per MIL-HDBK-217E
20050 SW 112th Ave. Tualatin, Oregon 97062
min
nom
240,000
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com
hours
date 09/2010
page 3 of 4
a division of CUI INC
SERIES:
DESCRIPTION:
6 W WALL PLUG
SWITCHING POWER SUPPLY
MECHANICAL DRAWING
17.0
43.3
1.0
26.6
1.0
12.7
63
1.0
22.3X18.0
1800 100
Units: mm
6.3
Tolerance:
X.X ±0.5mm
X.XX ±0.03mm
NOTE 1: THIS POWER UNIT IS INTENDED TO
BE CORRECTLY ORIENTED IN A VERTICAL
OR FLOOR MOUNT POSITION.
3.0
(TYP)
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com
date 09/2010
page 4 of 4
a division of CUI INC
SERIES:
DESCRIPTION:
6 W WALL PLUG
SWITCHING POWER SUPPLY
OUTPUT PLUG OPTIONS
˄ˇʳ̈́˃ˁˈ
΋ˆˁˈʳʾ˃˂ˀ˃ˁ˄
΋ˆˁˈʳʾ˃˂ˀ˃ˁ˄
3.5 mm Phono Plug
˄ˇʳ̈́˃ˁˈ
*Tip positive
P1
P1R
Standard DC Plug
˖
Standard PX
P5/P5R
P6/P6R
P7/P7R
P8/P8R
P9/P9R
˕
˔
˕
˔
˖
Right Angle PXR
A
5.5
5.5
3.5
3.8
3.8
B
2.1
2.5
1.3
1.35
1.05
C
9.5
9.5
9.5
9.5
9.5
Unit
mm
mm
mm
mm
mm
Locking DC Plug
˖
˔
˕
P10
P11
A
5.5
5.5
B
2.1
2.5
C
9.5
9.5
Unit
mm
mm
EIAJ Plugs
EIAJ
A
B
P12/P12R EIAJ-1 2.35 0.7
P13/P13R EIAJ-2 4.0 1.7
P14/P14R EIAJ-3 4.75 1.7
˕
˔
˕
˔
˖
C
9.5
9.5
9.5
D
NA
5.0
5.0
Unit
mm
mm
mm
˖
Standard PXX
Right Angle PXXR
˗
Stripped and Tinned
˅ˈ̈́ˈ
DC PLUG TYPE
ST
PXX X X
stripped and tinned
Plug type
Plug angle:
“blank” = standard
R = right angle
*Contact CUI for additional output plug options.
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
Plug polarity:
“blank” = N/A
P = center positive
N = center negative
fax 503.612.2382 www.v-infinity.com