Mean Well DCW05B-05 5w dc-dc regulated dual output converter Datasheet

DCW05
5W DC-DC Regulated Dual Output Converter
series
Features :
2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
3000VDC I/O isolation(option)
Built-in EMI filter
Protections: Short circuit / Overload
Cooling by free air convection
Five-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
DCW05A-05 DCW05B-05 DCW05C-05 DCW05A-12 DCW05B-12 DCW05C-12 DCW05A-15 DCW05B-15 DCW05C-15
DC VOLTAGE
5V
12V
CURRENT RANGE
100 ~ 500mA
46 ~ 230mA
RATED POWER
OUTPUT
5W
RIPPLE & NOISE (max.) Note.2 50mVp-p
LINE REGULATION
Note.3 0.5%
LOAD REGULATION
Note.4
VOLTAGE ACCURACY
38 ~ 190mA
5.5W
5.7W
60mVp-p
60mVp-p
0.5%
2.0%
SWITCHING FREQUENCY
INPUT
15V
50KHz min.
VOLTAGE RANGE
A: 9 ~ 18VDC
EFFICIENCY (Typ.)
75%
DC CURRENT
FILTER
B: 18 ~ 36VDC
77%
C: 36 ~ 72VDC
77%
80%
Full load A: 586mA B: 286mA
C: 139mA
No load
C: 12mA
A: 41mA
B: 21mA
83%
82%
81%
85%
83%
Pi network
Fuse recommended
150 ~ 250% rated output load
Protection type : Shunt down o/p voltage, re-power on to recover
All output equipped with over current protection
PROTECTION
OVERLOAD
PROTECTION
SHORT CIRCUIT
Protection type : Shun down o/p voltage, re-power on to recover
-40 ~ +71 (refer to output load derating curve)
WORKING TEMP.
20% ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
-40 ~ +105
, 10 ~ 95% RH
0.03% /
(0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
EMC
ISOLATION CAPACITANCE
(Note. 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
EMS IMMUNITY
MTBF
900khrs min. MIL-HDBK-217F (25 )
OTHERS
DIMENSION
80pF max.
31.8*20.3*12.2mm (L*W*H) or 1.25"*0.80"*0.48" inch (L*W*H)
15g
PACKING
Derating Curve
Pin Configuration
Mechanical Specification
Unit:mm(inch)
22
3
BOTTOM VIEW
16
9
14
11
2.5( 0.10 )
5.0( 0.20 )
Pin No.
Output
2&3
9
11
14
16
22 & 23
- Vi n
COM
- Vo u t
+ Vo u t
COM
+ Vi n
100
LOAD (%)
2
3.8(0.15)
17.8(0.70)
23
31.8(1.25)
4.6(0.18)
20.3(0.80)
80
-40
15.2(0.60)
0.6+ 0.1/-0(0.024)
0
25
50 60 71
Ta (
NOTE
100
12.2(0.48)
)
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:DCW05-SPEC 2011-03-14
Similar pages