Mean Well CLG-100-20 100w single output switching power supply Datasheet

CLG-100
100W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency 90%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty (Note.6)
110
F
M
M
SELV
SPECIFICATION
MODEL
DC VOLTAGE
IP67
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
15V
20V
24V
27V
36V
48V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
27 ~ 36V
36 ~ 48V
2.65A
2A
RATED CURRENT
Note.5 5A
5A
4.8A
4A
20.25 ~ 27V
3.55A
RATED POWER
Note.5 60W
75W
96W
96W
95.85W
95.4W
96W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3
3.0%
LINE REGULATION
1.0%
3.0%
SETUP, RISE TIME
1200ms, 80ms / 230VAC
HOLD UP TIME (Typ.)
60ms / 230VAC
VOLTAGE RANGE
3.0%
3.0%
3.0%
2.0%
Note.4 90 ~ 295VAC
1200ms, 80ms / 115VAC at full load
30ms / 115VAC at full load
127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
84.5%
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
LEAKAGE CURRENT
OVER CURRENT (Typ.)
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS Note.8
86.5%
90%
90%
15V:0.9A/115VAC
90%
0.45A/230VAC
90%
20V ~ 48V:1.1A/115VAC
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
39 ~ 48V
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent
CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
301Khrs min. MIL-HDBK-217F (25
222.2*68*38.8mm (L*W*H)
1.0Kg; 12pcs/13Kg/0.58CUFT
PACKING
NOTE
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
EMC
DIMENSION
89%
0.55A/230VAC
95 ~ 102%
SAFETY & WITHSTAND VOLTAGE
OTHERS
2.0%
2.0%
LOAD REGULATION
PROTECTION
( except for 48V )
12V
RIPPLE & NOISE (max.) Note.2 150mVp-p
INPUT
( for 48V only)
CLG-100-12
CONSTANT CURRENT REGION Note.7 9 ~ 12V
OUTPUT
LPS
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
7. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:CLG-100-SPEC 2011-07-28
CLG-100
100W Single Output Switching Power Supply
Mechanical Specification
Case No. 954A
series
Unit:mm
222.2
198.2
12
9.4
9.6
300 20
34.2
300 20
T case
SVT 18AWG 2C
9.4
34
SJTW 18AWG 3C
+V(Red)
-V(Black)
99.1
68
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
4.2 4PL
38.8
T case: Max. Case Temperature.
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
O.L.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-10
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
295
INPUT VOLTAGE (V) 60Hz
File Name:CLG-100-SPEC 2011-07-28
CLG-100
100W Single Output Switching Power Supply
series
Power Factor Characteristic
PF
Constant Current Mode
1
0
0
0
0
0
0
0
0
0
0
0
.0
.9
.9
.9
.9
.9
.8
.8
.8
.8
.8
.7
0
8
6
4
2
0
8
6
4
2
0
8
2 7 7 V ac
2 3 0 V ac
1 1 5 V ac
5 0 %
6 0 %
7 0 %
8 0 %
9 0 %
1 0 0 %
(100W)
LOAD
EFFICIENCY vs LOAD (48V Model)
CLG-100 series possess superior working efficiency that up to 89% can be reached in field applications.
92
88
EFFICIENCY (%)
84
80
277Vac
76
230Vac
72
115Vac
68
64
60
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
Vo(%)
100
(B)
Constant
Current area
(A) Constant
Voltage area
75
(max.)
(C)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:CLG-100-SPEC 2011-07-28