CLG-100 100W Single Output Switching Power Supply series Features : Universal AC input / Full range (up to 295VAC) Built-in active PFC function High efficiency 90% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Pass LPS 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty (Note.6) 110 F M M SELV SPECIFICATION MODEL DC VOLTAGE IP67 CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48 15V 20V 24V 27V 36V 48V 11.25 ~ 15V 15 ~ 20V 18 ~ 24V 27 ~ 36V 36 ~ 48V 2.65A 2A RATED CURRENT Note.5 5A 5A 4.8A 4A 20.25 ~ 27V 3.55A RATED POWER Note.5 60W 75W 96W 96W 95.85W 95.4W 96W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE Fixed. Can be modified between 0% ~ -15% rated output voltage CURRENT ADJ. RANGE Fixed. Can be modified between 3% ~ -25% rated output current VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 1.0% 3.0% SETUP, RISE TIME 1200ms, 80ms / 230VAC HOLD UP TIME (Typ.) 60ms / 230VAC VOLTAGE RANGE 3.0% 3.0% 3.0% 2.0% Note.4 90 ~ 295VAC 1200ms, 80ms / 115VAC at full load 30ms / 115VAC at full load 127 ~ 417VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) EFFICIENCY (Typ.) 84.5% AC CURRENT (Typ.) INRUSH CURRENT(max.) 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT OVER CURRENT (Typ.) SHORT CIRCUIT OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.8 86.5% 90% 90% 15V:0.9A/115VAC 90% 0.45A/230VAC 90% 20V ~ 48V:1.1A/115VAC <0.75mA / 240VAC Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 90 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved I/P-O/P:3.75KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A MTBF 301Khrs min. MIL-HDBK-217F (25 222.2*68*38.8mm (L*W*H) 1.0Kg; 12pcs/13Kg/0.58CUFT PACKING NOTE 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover EMC DIMENSION 89% 0.55A/230VAC 95 ~ 102% SAFETY & WITHSTAND VOLTAGE OTHERS 2.0% 2.0% LOAD REGULATION PROTECTION ( except for 48V ) 12V RIPPLE & NOISE (max.) Note.2 150mVp-p INPUT ( for 48V only) CLG-100-12 CONSTANT CURRENT REGION Note.7 9 ~ 12V OUTPUT LPS I/P-FG:1.88KVAC O/P-FG:0.5KVAC ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 . 7. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:CLG-100-SPEC 2011-07-28 CLG-100 100W Single Output Switching Power Supply Mechanical Specification Case No. 954A series Unit:mm 222.2 198.2 12 9.4 9.6 300 20 34.2 300 20 T case SVT 18AWG 2C 9.4 34 SJTW 18AWG 3C +V(Red) -V(Black) 99.1 68 AC/L(Brown) AC/N(Blue) FG (Green/Yellow) 4.2 4PL 38.8 T case: Max. Case Temperature. Block Diagram Fosc : 100KHz EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING +V -V O.L.P. FG O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 230VAC Input only 70 LOAD (%) LOAD (%) 60 40 20 -30 -25 -10 0 15 30 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 295 INPUT VOLTAGE (V) 60Hz File Name:CLG-100-SPEC 2011-07-28 CLG-100 100W Single Output Switching Power Supply series Power Factor Characteristic PF Constant Current Mode 1 0 0 0 0 0 0 0 0 0 0 0 .0 .9 .9 .9 .9 .9 .8 .8 .8 .8 .8 .7 0 8 6 4 2 0 8 6 4 2 0 8 2 7 7 V ac 2 3 0 V ac 1 1 5 V ac 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % (100W) LOAD EFFICIENCY vs LOAD (48V Model) CLG-100 series possess superior working efficiency that up to 89% can be reached in field applications. 92 88 EFFICIENCY (%) 84 80 277Vac 76 230Vac 72 115Vac 68 64 60 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)]. Vo(%) 100 (B) Constant Current area (A) Constant Voltage area 75 (max.) (C) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:CLG-100-SPEC 2011-07-28