APT5024BFLL APT5024SFLL 500V 22A 0.240W POWER MOS 7TM FREDFET BFLL D3PAK Power MOS 7TM is a new generation of low loss, high voltage, N-Channel enhancement mode power MOSFETS. Both conduction and switching losses are addressed with Power MOS 7TM by significantly lowering RDS(ON) and Qg. Power MOS 7TM combines lower conduction and switching losses along with exceptionally fast switching speeds inherent with APT's patented metal gate structure. • Lower Input Capacitance • Lower Miller Capacitance • Lower Gate Charge, Qg VDSS ID SFLL D • Increased Power Dissipation • Easier To Drive • TO-247 or Surface Mount D3PAK Package • FAST RECOVERY BODY DIODE MAXIMUM RATINGS Symbol TO-247 G S All Ratings: TC = 25°C unless otherwise specified. APT5024 Parameter UNIT L A C I N H C N E T O I E T C MA N A OR V AD INF 500 Drain-Source Voltage Volts 22 Continuous Drain Current @ TC = 25°C 1 Amps IDM Pulsed Drain Current VGS Gate-Source Voltage Continuous ±30 Gate-Source Voltage Transient ±40 Total Power Dissipation @ TC = 25°C 265 Watts Linear Derating Factor 2.12 W/°C VGSM PD TJ,TSTG 88 -55 to 150 Operating and Storage Junction Temperature Range TL Lead Temperature: 0.063" from Case for 10 Sec. IAR Avalanche Current 1 22 1 Repetitive Avalanche Energy EAS Single Pulse Avalanche Energy °C 300 (Repetitive and Non-Repetitive) EAR Volts Amps 30 4 mJ 960 STATIC ELECTRICAL CHARACTERISTICS RDS(on) IDSS IGSS VGS(th) Drain-Source Breakdown Voltage (VGS = 0V, I D = 250µA) 500 Volts 22 Amps On State Drain Current 2 (VDS > I D(on) x R DS(on) Max, VGS = 10V) Drain-Source On-State Resistance 2 (VGS = 10V, 0.5 ID[Cont.]) TYP MAX 0.240 UNIT Ohms Zero Gate Voltage Drain Current (VDS = VDSS, VGS = 0V) 250 Zero Gate Voltage Drain Current (VDS = 0.8 VDSS, VGS = 0V, TC = 125°C) 1000 Gate-Source Leakage Current (VGS = ±30V, VDS = 0V) ±100 nA 5 Volts Gate Threshold Voltage (VDS = VGS, ID = 1mA) 3 µA CAUTION: These Devices are Sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed. APT Website - http://www.advancedpower.com USA 405 S.W. Columbia Street Bend, Oregon 97702 -1035 Phone: (541) 382-8028 FAX: (541) 388-0364 EUROPE Chemin de Magret F-33700 Merignac - France Phone: (33) 5 57 92 15 15 FAX: (33) 5 56 47 97 61 10-2001 ID(on) MIN Rev - BVDSS Characteristic / Test Conditions 050-7131 Symbol APT5024 BFLL - SFLL DYNAMIC CHARACTERISTICS Symbol Characteristic Test Conditions MIN TYP Ciss Input Capacitance VGS = 0V 1910 Coss Output Capacitance VDS = 25V 390 Crss Reverse Transfer Capacitance f = 1 MHz 30 Qg Total Gate Charge VGS = 10V 48 Q gs Gate-Source Charge VDD = 0.5 VDSS Q gd Gate-Drain ("Miller ") Charge ID = ID [Cont.] @ 25°C 13 22 VGS = 15V 12 t d(on) 3 L A C I N H C N E T O I E T C MA N A OR V AD INF Turn-on Delay Time tr VDD = 0.5 VDSS 10 ID = ID [Cont.] @ 25°C 30 RG = 1.6W 7 Rise Time t d(off) Turn-off Delay Time tf Fall Time MAX UNIT pF nC ns SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS Symbol Characteristic / Test Conditions TYP Continuous Source Current (Body Diode) IS ISM Pulsed Source Current VSD Diode Forward Voltage dv/ MIN Peak Diode Recovery dt 1 (Body Diode) 2 dv/ dt (VGS = 0V, IS = -ID [Cont.]) 5 MAX 22 UNIT Amps 88 1.3 Volts 15 V/ns t rr Reverse Recovery Time (IS = -ID [Cont.], di/dt = 100A/µs) Tj = 25°C 250 Tj = 125°C 400 Qrr Reverse Recovery Charge (IS = -ID [Cont.], di/dt = 100A/µs) Tj = 25°C 1.9 Tj = 125°C 6 IRRM Peak Recovery Current (IS = -ID [Cont.], di/dt = 100A/µs) Tj = 25°C 15 Tj = 125°C 26 ns µC Amps THERMAL CHARACTERISTICS Symbol Characteristic RqJC Junction to Case RqJA Junction to Ambient MIN TYP MAX UNIT 0.47 °C/W 40 1 Repetitive Rating: Pulse width limited by maximum junction temperature. 2 Pulse Test: Pulse width < 380 µs, Duty Cycle < 2% 3 See MIL-STD-750 Method 3471 4 Starting T = +25°C, L = 3.97mH, R = 25W, Peak I = 22A j G L 5 dv/ numbers reflect the limitations of the test circuit rather than the dt device itself. IS £ -ID[Cont.] di/dt £ 700A/µs VR £ VDSS TJ £ 150°C APT Reserves the right to change, without notice, the specifications and information contained herein. 3 TO-247 Package Outline 15.49 (.610) 16.26 (.640) 6.15 (.242) BSC Drain Drain (Heat Sink) 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) D PAK Package Outline 5.38 (.212) 6.20 (.244) 4.98 (.196) 5.08 (.200) 1.47 (.058) 1.57 (.062) 15.95 (.628) 16.05 (.632) Revised 4/18/95 20.80 (.819) 21.46 (.845) 1.04 (.041) 1.15 (.045) 13.79 (.543) 13.99 (.551) 13.41 (.528) 13.51 (.532) Revised 8/29/97 11.51 (.453) 11.61 (.457) 3.50 (.138) 3.81 (.150) 0.46 (.018) 0.56 (.022) {3 Plcs} 050-7131 Rev - 10-2001 4.50 (.177) Max. 0.40 (.016) 0.79 (.031) 1.65 (.065) 2.13 (.084) 19.81 (.780) 20.32 (.800) 1.01 (.040) 1.40 (.055) 2.21 (.087) 2.59 (.102) 0.020 (.001) 0.178 (.007) 2.67 (.105) 2.84 (.112) 2.87 (.113) 3.12 (.123) 1.27 (.050) 1.40 (.055) 1.22 (.048) 1.32 (.052) 5.45 (.215) BSC {2 Plcs.} Gate Drain Source Source Drain Gate Dimensions in Millimeters (Inches) 5.45 (.215) BSC 2-Plcs. Dimensions in Millimeters and (Inches) APT's devices are covered by one or more of the following U.S.patents: 1.98 (.078) 2.08 (.082) 4,895,810 5,256,583 5,045,903 4,748,103 5,089,434 5,283,202 5,182,234 5,231,474 5,019,522 5,434,095 5,262,336 5,528,058 3.81 (.150) 4.06 (.160) (Base of Lead) Heat Sink (Drain) and Leads are Plated