FE5A AC-DC Front End Data Sheet Three-Phase Input, 5000 Watts Features • Three-phase Ac input • High efficiency: 90% at full load • 11.8 Watts/cubic inch power density • Power factor corrected • No minimum load required • Single-wire current sharing • Current limit and over-voltage protection • Full power up to 50º C • Compact size: 5” x 5” x 17” • LED supply status indicators • TUV, cTUVus & CB report Model Number FE5A-1D-0 FE5A-1E-0 FE5A-1F-0 FE5A-1G-0 FE5A-1H-0 FE5A-1J-0 Output Rating 12V/400A 15V/330A 24V/208A 28V/180A 36V/140A 48V/104A Options O = M (Output power good – TTL high); N (Power fail – TTL high); R (Reverse airflow) Description The ultra-compact FE5A Series Front-End Power Supply provides a single isolated output of up to 5000-Watts with inputs ranging from 365 Vac to 528 Vac, 3 phase, and can handle frequencies from 47 Hz to 63 Hz. Designed for high current applications requiring a compact size. The FE5A series operates either as a standalone unit or as part of rack-mounted power systems. The supply provides true front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. Input Specifications Output Specifications Input voltage range: 380 to 498 Vac, 480 Vac Nominal, Three Phase, 47 to 63 Hz. Power Factor: >0.95 at full load and nominal line Inrush Current: 40 A peak hot and cold start Input Protection: 15A internal fuse per line is provided Output Power: 5000 W maximum Output Voltage & Current Ratings: See chart shown above Overshoot/Undershoot: Less than 1% at turn-on or turn-off. Less than 2% for 50% to 100% load step. Start-Up Time: Less than 3 seconds Efficiency: 90% typical measured at full load, nominal input Hold-up Time: 20 ms minimum at full load and low line Overcurrent Protection: Set to 105-130% of full rated load with automatic recovery Overtemperature Protection: Automatic shutdown with auto recovery. Remote Sense: Compensates for voltage drop of up to 0.5 V to the load. Shorted sense lead protection. Overvoltage Protection: Set at 120%-130% of nominal; reset by cycling input power. Output Noise and Ripple: PARD: 1% of output voltage measured at 20 Mhz bandwidth. Single Wire Current Share: 5% full load rating Load Regulation: 0.5% with remote sense, 2% without Line Regulation: 0.2% over entire operating range Minimum Load: No minimum load required Signals and Controls LED Output Good Indicator: Front panel green LED indicates power supply is good; amber indicates fault. LED AC Good Indicator: Front panel green LED indicates Ac input voltage is present and above minimum level. Output Good Signal*: TTL compatible signal, normally high. Goes low when power supply is out of specified range. Power Fail Signal*: TTL compatible signal, normally high (indicating Vin is present and above minimum level). Enable*: Normally TTL High, drive low to enable. *All interface signals are TTL compatible Nov 7, 2006 Page 1 of 3 www.power-one.com FE5A AC-DC Front End Data Sheet Three-Phase Input, 5000 Watts Safety & Environmental Safety & Environmental (continued) Temperature Range: Operating: 0 to 50°C Storage: -40°C to +85°C Operating Humidity: Maximum 95% RH non-condensing Operating Altitude: 10,000 feet Non-operating Altitude: 40,000 feet Temperature Coefficient: 0.01% per °C within rated load Safety Agency Compliance: TUV, cTUVus & CB report EMI: Meets EN55022, Class A Harmonic Suppression: Meets EN6100-3-2 Input Transient Protection: Electrostatic Discharge: EN61000-4-2, Criteria B Radiated, Radio-Frequency, Electromagnetic Field: EN61000-4-3, Criteria A Electrical Fast Transients/Burst: EN61000-4-4, Criteria B Voltage Fluctuations and Flickers: EN61000-3-3, Criteria B Surge Test: EN61000-4-5, Criteria B Conducted Immunity: EN61000-4-6, Criteria A Dielectric Withstand: Input-to-ground: 2121 Vdc Input-to-output: 4242 Vdc Output-to-case: 50 Vdc Ac Leakage Current: 2mA maximum at 480 Vac, 60 Hz Mechanical Specifications Size: 5” H x 5” W x 17” D Input/Output Connector: Elcon Double Drawer male connector Mating Connector: Elcon Double Drawer female connector MTBF: 100,000 hours calculated at 50°C, Bellcore Standard Warranty: Two years from date of shipment, standard product only Specifications are subject to change without notice. Outline Drawing and Dimensions Nov 7, 2006 Page 2 of 3 www.power-one.com FE5A AC-DC Front End Data Sheet Three-Phase Input, 5000 Watts Connector Pin Descriptions Pin Number 1 2 3 4 9 17 18 19 Signal Name Output (+) Output (+) Output (-) Output (-) Chassis Ground I_Share_M Remote Sense S+ DC_Enable (See Note 1) 20 26 27 28 37 38 39 PF_HI (See Note 2) Remote Sense SLogic_Rtn Pwr_OK (See Note 3) Input Line A Input Line B Input Line C Notes 1. To turn on output, short Dc-Enable pin # 19 to Logic_Rtn, Pin #27 and short pin 29 to pin 21 2. Ac Good: PF_Hi Pin #20 ref. to Logic_Rtn Pin #27 3. Output Good: Pwr_OK Hi Pin #28 ref. to Logic_Rtn Pin #27 NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Nov 7, 2006 Page 3 of 3 www.power-one.com