ETC1 CX480D5 5amp 120/240, 380, 480 vac ac output sip Datasheet

Series CX
5Amp • 120/240, 380, 480 Vac • AC Output SIP
• SCR Output
• Ultra High Surge Rating
• Crydom’s Patented Design
Crydom's family of SPST-NO relays
achieves the highest power switching
capability in a PC-mounted air-cooled
package. Advanced features include
exceptional steady state current, plus
ultra-high surge ratings. Models are
available to switch up to 660 Vrms with
AC or DC control, and either zero-cross
or random turn-on ("R") switching versions. Pinout is compatible with Series
6 and OAC type I/O modules.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
AC CONTROL (120Vac)
(24Vac)
CX240A5
CXE240A5
(5Vdc)
(24Vdc)
CX240D5
CXE240D5
CX380D5
CXE380D5
CX480D5
CXE480D5
12-280
48-530
48-660
Load Current Range [Arms]
.06-5
.06-5
.06-5
Transient Overvoltage [Vpk]
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
250
250
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.4
1.4
1.4
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
260
260
Max. Off-State Leakage Current @ Rated Voltage [mArms]
0.1
0.1
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
500
500
500
MODEL NUMBERS
DC CONTROL
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Turn-On Time ➂
1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time
1/2 Cycle (DC Control), 40.0 msec (AC Control)
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
Nominal Voltage
0.5
DC CONTROL
5Vdc
5Vdc
CX240D5
Control Voltage Range
0.5
AC CONTROL
120Vac
24Vac
CX380D5
CX480D5
24Vdc
CXE240D5
CXE380D5
CXE480D5
CX240A5
CXE240A5
3-15 Vdc
4-15 Vdc
15-32 Vdc
90-140 Vrms
18-36 Vrms
Max. Turn-On Voltage
3.0 Vdc
4.0 Vdc
15.0 Vdc
90.0 Vrms
18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
10.0 Vrms
2.0 Vrms
Nominal Input Impedance
300 Ohm
240 Ohm
1500 Ohm
14.1k Ohm
4.2k Ohm
Typical Input Current @ Nominal Voltage
15 mAdc
15 mAdc
15 mAdc
10 mArms
5 mArms
MODEL NUMBERS
©2001 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models).
FastFax Document No.107
SERIES CX.
Rev. 012402
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506
Series CX
5Amp • 120/240, 380, 480 Vac • AC Output SIP
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-30 to 80ºC
Ambient Storage Temperature Range
-30 to 125ºC
M ECHANICAL SPECIFICATIONS
Weight: (typical)
0.4 oz. (11g)
Thermally Conductive Epoxy
Encapsulation:
CURRENT DERATING CURVE
.300 (7.6)
AC CONTROL
PIN
PIN
PIN
PIN
LOAD CURRENT [AMPS]
6.0
1.00
MAX.
(25.4)
5.0
4.0
CONTROL
3.0
.300 TYP.
(7.6)
2.0
.200
(5.1)
1.0
0
20
40
60
AMBIENT TEMPERATURE [˚C]
Max. Load Current vs. Temp.
80
1:
2:
3:
4:
AC
AC
AC
AC
LOAD
LOAD
CONTROL
CONTROL
LOAD
DC CONTROL
4
3
2
.700
(17.8)
1.70
(43.1)
1
.050
TYP.
(1.3)
1.100
(27.9)
.100
(2.5)
PIN
PIN
PIN
PIN
1:
2:
3:
4:
AC LOAD
AC LOAD
+DC CONTROL
-DC CONTROL
.040 (1.0) DIA.
(4 PLACES)
All dimensions are in inches (millimeters)
©2001 CRYDOM CORP, Specifications subject to change without notice.
AVAILABLE OPTIONS
R
Random Turn-On Switching
Example: CX240D5 R, CX240A5 R
APPROVALS
UL
E116949
CSA LR81689
VDE 70938
UG (240V, 380V, DC Control Only)
FastFax Document No.107
SERIES CX.
Rev. 012402
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506