AIMTEC AME2-5SNJZ 2 watt i ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AME2-NJZ
2 Watt | AC-DC / DC-DC Converter
FEATURES:
Picture coming soon
Models
Single output
Model
Input Voltage
(VAC/Hz)
AME2-5SNJZ
AME2-12SNJZ
AME2-24SNJZ
165-264/47-63
165-264/47-63
165-264/47-63
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Minimum load
Ripple & Noise
Hold up time
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
General Specifications
Parameters
Switching frequency
Over Current protection
Short circuit protection
Operating temperature*
Storage temperature
Temperature coefficient
Maximum Case temperature
Humidity
Case material
Weight
Cooling
Dimensions (L x W x H)
MTBF









I/O Isolation 3000VAC
Operating Temp: -40°C to +70°C
Input: 165-264VAC, 47-63Hz, or 233-370 VDC
No internal electrolytic capacitors
Longer product life
Class II Power supply
Low no load consumption ≤ 0.3W
Continuous Short Circuit Protection
Over current Protection
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(mA)
Maximum
capacitive
Load
(µF)
Efficiency
(%)
233-370
233-370
233-370
-40 to +70
-40 to +70
-40 to +70
5
12
24
400
167
83
3000
1000
220
70
76
78
Conditions
Typical
165 VAC
230 VAC
165 VAC
230 VAC
230VAC/50Hz, rms
Recommended slow blow type
30
25
Typical
Full Load
LL-HL, Full Load
10% - 100% load, nominal input
±2
±1
±1
10
50
8
16
Conditions
Typical
60 sec
Auto recovery
No derating
Typical
Units
Maximum
Units
150
%
%
%
%
mV p-p
ms
Rated
Units
3000
VAC
MΩ
>1000
Conditions
VAC
mA
mA
A
A
mA
A
6
10
0.1
2
Conditions
20MHz bandwidth
165VAC
230VAC
Maximum
230
Maximum
115
≥110
Hiccup, Auto recovery, Continuous
-40 to +70
-40 to +105
±0.01
Units
KHz
% of Iout
100
Non condensing
95
Plastic resin (flammability to UL 94V-0)
25
Free air convection
1.46 x 0.96 x 0.71 (37.00 x 24.50 x 18.00mm)
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
°C
°C
%/°C
°C
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
* Sufficient air space around is needed.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME2-NJZ
2 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Pin Out Specifications
Pin
Single
Dimensions
5.08
(0.20)
37.00
(1.46)
AC Input (L)
AC Input (N)
-V Output
+V Output
+V Cap
-V Cap
1
24.50
(0.97)
1
3
14
16
20
22
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2, Contact:±6KV/Air:±8KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B, with application circuit
IEC 61000-4-5, ±1KV/±2KV, Criteria B, with application circuit
IEC 61000-4-6, 10Vrms, Criteria A
IEC 61000-4-8, 10A/m, Criteria A
IEC 61000-4-11, 0-70%, Criteria B
3
17.78
(0.70)
Standards
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity(1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Bottom View
22
5.08
(0.20)
20
16
10.16
(0.40)
14
5.08
(0.20)
18.00
(0.71)
Printed Face
All dimensions are typical: millimeters (inches)
Pin Diameter: 0.60 ± 0.10 (0.02 ± 0.004)
Case Tolerance: ± 0.5 (±0.02)
4.10
(0.16)
0.60
(0.02)
Application circuit for Vin: 165-264VAC
Single Output
FUSE
1A/250V
AC L
AC L
20
22
AC N
AC
AC N
+ Vout
+ Vout
DC
+
TVS
C1
C2
1µF/50V
‐ Vout
‐ Vout
*GND connection not allowed
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME2-NJZ
2 Watt | AC-DC / DC-DC Converter
Application circuit for Vin: 85-264VAC
Single Output
FUSE
1A/250V
+ Vout
+ Vout
AC L
AC L
20
+
C3
AC
+
DC
C1
C2
1µF/50V
22
AC N
AC N
TVS
‐ Vout
‐ Vout
*GND connection not allowed
Model
5 Vout
12 Vout
24 Vout
C2
100 µF / 35V
68 µF / 35V
47 µF / 35V
C3
4.7 µF / 400V
TVS
7V
20V
30V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages