Series AM10TW-IZ 10 Watt | DC-DC Converter FEATURES: Short Circuit & OVP Protection 24 Pin DIP Package Wide 4:1 input range Power modules for PCB mounting No minimum load Operating temperature -40oC to + 75oC Regulated output Low ripple and noise Input/output Isolation voltage 1500VDC Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Capacitive Load, max(uf) Ripple & Noise max, (% mV p-p) Efficiency (%) AM10TW-2403SIZ AM10TW-2405SIZ AM10TW-2412SIZ AM10TW-2415SIZ AM10TW-4803SIZ AM10TW-4805SIZ AM10TW-4812SIZ AM10TW-4815SIZ 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 3.3 5 12 15 3.3 5 12 15 2000 2000 830 660 2000 2000 830 660 4200 3200 600 390 4200 3200 600 390 80 80 120 150 80 80 120 150 71 75 78 78 73 83 81 81 Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Capacitive Load, max(uf) Ripple & Noise max, (%) Efficiency (%) AM10TW-2405DIZ AM10TW-2412DIZ AM10TW-2415DIZ AM10TW-4805DIZ AM10TW-4812DIZ AM10TW-4815DIZ 9-36 9-36 9-36 18-75 18-75 18-75 ±5 ±12 ±15 ±5 ±12 ±15 ±1800 ±300 ±200 ±1800 ±300 ±200 80 120 150 80 120 150 75 79 80 77 80 80 Models Dual output ±1000 ±410 ±330 ±1000 ±410 ±330 Input Specifications Parameters Nominal Typical 24 48 9-36 18-75 24 Vin 48 Vin Voltage range Filter Maximum Units VDC Capacitor Absolute Maximum Rating Permissible absolute maximum duration Transient Voltage Deviation 50 100 100 5 VDC ms VDC Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 60 sec Rated Units 1500 VDC MOhm pF Maximum Units > 1000 470 Output Specifications Parameters Conditions Typical Voltage accuracy Short Circuit protection Short Circuit restart www.aimtec.com F 051e R12.A ±2 % Continuous Auto recovery Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM10TW-IZ 10 Watt | DC-DC Converter Output Specifications (continued) Parameters Over voltage protection Over load protection Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Conditions Typical Zener diode clamp Auto recovery HL-LL 0 – 100% full load 0 – 100% full load >110% Over 110% full load ±0.5 ±0.5 ±2 ±0.05 80 mV p-p 1% Vout p-p 3.3 & 5V models 12 & 15V models Ripple & Noise Maximum Units VDC % % % %/oC mV General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz o Operating temperature Derating above +50 oC -40 to +75 C o Storage temperature -55 to +115 C o Case Temperature +95 C Cooling Free air convection Humidity 95 % Case material Nickel coated cooper Weight 18 g Dimensions (L x W x H) Tolerance ±0.02 inch, ±0.5mm 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm MTBF > 700 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Standards Safety UL (pending) EN 55022, class A EN 55024 Pin Out Specifications Dimensions Dual -V Input -V Input N.C. Omitted N.C. +V Output Omitted -V Output +V Input +V Input -V Input -V Input Common Omitted -V Output + V Output Omitted Common +V Input +V Input 2 20.30 (0.80) Single 2 3 9 10 11 14 15 16 22 23 22.80 (0.90) 0.50 (0.02) 3 9 11 Bottom View 23 22 2.50 (0.10) 16 14 5.00 (0.20) Printed Face 3.80 (0.15) 10.20 (0.40) Pin 31.80 (1.25) 15.20 (0.60) Agency approvals www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM10TW-IZ 10 Watt | DC-DC Converter Output Power % Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only