AZETTLER AZ7335 Dielectric strength 5000 vrm Datasheet

AZ7335
DPDT MINIATURE
POWER RELAY
FEATURES
•
•
•
•
•
•
•
•
Dielectric strength 5000 Vrms
Low cost
Epoxy sealed version available
8 Amp switching — double pole contacts
Isolation spacing greater than 8mm
Class F insulation system available
UL, CUR E44211
TUV R50290835
GENERAL DATA
CONTACTS
Arrangement
DPST (2 Form A)
DPDT (2 Form C)
Ratings
Resistive load:
Max. switched power: 240 W or 2000 VA
Max. switched current: 8 A
Max. switched voltage: 30* VDC or 250 VAC
*Note: If switching voltage is greater than 30 VDC, special
precautions must be taken. Please contact the factory.
Rated Load
UL, CUR
Normally Open Contacts (N.O.)
8 A at 250 VAC, Resistive,100k cycles
8 A at 30 VDC, Resistive 100k cycles
Normally Closed Contacts (N.C.)
4 A at 250 VAC, Resistive, 100k cycles
4 A at 30 VDC, Resistive, 100k cycles
TUV
5A NO / 3A NC @ 250VAC / 30VDC, 100k cycles, 85°C
10A NO / 5A NC @ 250VAC / 30VDC, 100k cycles, 85°C
16A NO / 8A NC @ 250VAC / 30VDC, 100k cycles, 85°C
Material
Silver tin oxide
Resistance
100 milliohms max.
(6 V, 1 A voltage drop method)
COIL
Power
At Pickup Voltage
(typical)
Max. Continuous
Dissipation
353 mW(Standard), 300 mW(Sensitive)
1.2 W at 20°C (68°F) ambient (Standard)
0.9 W at 20°C (68°F) ambient (Sensitive)
Temperature Rise
Temperature
40°C (104°F) at nominal coil voltage
Max. 105°C (221°F)
Max. 155°C (311°F) Class F
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 107
1 x 105 at 5 A 250 VAC Res.
Operate Time (max)
15 ms at nominal coil voltage (standard)
20 ms at nominal coil voltage (sensitive)
Release Time (max)
8 ms at nominal coil voltage
(with no coil suppression)
Dielectric Strength
5000 VAC contact to coil
(at sea level for 1 min.) 1000 VAC between open contacts
2500 VAC between contact sets
10,000 V surge contact to coil
Insulation Resistance
1000 megohms min. at 500 VDC
Dropout
Greater than 10% of nominal coil voltage
Ambient Temperature
Operating
Storage
At nominal coil voltage
-40°C (-40°F) to 85°C (185°F)
-40°C (-40°F) to 105°C (221°F)
Vibration
0.059" DA at 10–55 Hz
Shock
Mechanical
Operational
100G
10 G
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy, P.C.
Max. Solder Temp.
270°C (518°F)
Max. Solder Time
5 seconds
Max. Solvent Temp.
80°C (176°F)
Max. Immersion Time
30 seconds
Weight
13 grams
NOTES
1. All values at 23°C (73.4°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
3/13/2015
AZ7335
RELAY ORDERING DATA
COIL SPECIFICATIONS (STANDARD)
Nominal Coil
VDC
3
Must Operate
VDC
2.1
Max. Continuous
VDC
3.9
5
6
9
12
18
24
48
3.5
4.2
6.3
8.4
12.6
16.8
33.6
6.5
7.8
11.7
15.6
23.4
31.2
62.4
ORDER NUMBER*
Coil
Resistance
13 ±10%
Form A
(DPST)
AZ7335–2A–3DK
Form C
(DPDT)
AZ7335–2C–3DK
36
48.5
115
200
450
820
3300
±10%
±10%
±10%
±10%
±10%
±10%
±10%
AZ7335–2A–5DK
AZ7335–2A–6DK
AZ7335–2A–9DK
AZ7335–2A–12DK
AZ7335–2A–18DK
AZ7335–2A–24DK
AZ7335–2A–48DK
AZ7335–2C–5DK
AZ7335–2C–6DK
AZ7335–2C–9DK
AZ7335–2C–12DK
AZ7335–2C–18DK
AZ7335–2C–24DK
AZ7335–2C–48DK
Coil
Resistance
17 ±10%
Form A
(DPST)
AZ7335–2A–3DSK
Form C
(DPDT)
AZ7335–2C–3DSK
48.5
68
155
270
600
1100
4400
AZ7335–2A–5DSK
AZ7335–2A–6DSK
AZ7335–2A–9DSK
AZ7335–2A–12DSK
AZ7335–2A–18DSK
AZ7335–2A–24DSK
AZ7335–2A–48DSK
AZ7335–2C–5DSK
AZ7335–2C–6DSK
AZ7335–2C–9DSK
AZ7335–2C–12DSK
AZ7335–2C–18DSK
AZ7335–2C–24DSK
AZ7335–2C–48DSK
RELAY ORDERING DATA
COIL SPECIFICATIONS (SENSITIVE)
Nominal Coil
VDC
3
Must Operate
VDC
2.25
Max. Continuous
VDC
3.9
5
6
9
12
18
24
48
3.75
4.50
6.75
9.00
13.50
18.00
36.00
6.5
7.8
11.7
15.6
23.4
31.2
62.4
ORDER NUMBER*
±10%
±10%
±10%
±10%
±10%
±10%
±10%
*For epoxy seal add “E” after DK or DSK. For class F insulation system add suffix “F” to part number.
HARDWARE ORDERING DATA
DESCRIPTION
ORDER NUMBER
DESCRIPTION
ORDER NUMBER
Socket (5.0 mm)
ST484–U1
Retainer
ST482–2
3/13/2015
AZ7335
MECHANICAL DATA
0# "/!2$ ,!9/54
&ORM ! AND #
› › 6IEWED TOWARD TERMINALS
$)!
› › › › › › › › $)! &ORM # ONLY
(!2$7!2%
PLACES &ORM !
PLACES &ORM #
34 5
-!8
$)!
7)2).' $)!'2!&ORM !
2ETAINING #LIP
&ORM #
6IEWED TOWARD TERMINALS
$)!
6IEWED TOWARD TERMINALS
34 Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010" unless specified.
3/13/2015