EPCOS B41851A2338M002 Aluminum electrolytic capacitor Datasheet

Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type:
B41851, B43851
Date:
January 2009
© EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Single-ended capacitors
B41851, B43851
Standard series 105 °C
General-purpose grade capacitors
Applications
General-purpose applications in the entertainment industry
Semi-professional to professional application range
For filtering, coupling and pulse circuits
Switch-mode power supplies
Features
Compact dimensions
High CV product, i.e. very compact
RoHS-compatible
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent from diameter 6.3 mm
Delivery mode
Terminal configurations and packing:
Bulk
Taped, Ammo pack
Cut
Kinked
PAPR (protection against polarity reversal):
crimped leads, J leads, bent leads
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details and ordering
example.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 36
B41851, B43851
Standard series 105 °C
Specifications and characteristics in brief
Series
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
B41851
6.3 ... 100 V DC
1.15 VR
0.1 ... 10000 µF
±20% M
B43851
160 ... 450 V DC
1.1 VR
0.47 ... 680 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
VR (V DC)
6.3
10
16
25
35
50
63
100 160 ...
450
tan δ (max.)
0.28 0.24 0.20 0.16 0.14 0.12 0.12 0.10 0.20
Leakage current Ileak
(20 °C, 5 min)
Self-inductance ESL
Useful life
105 °C; VR; IAC,R
40 °C; VR; 1.8 IAC,R
40 °C; VR; 2.1 IAC,R
Requirements
Voltage endurance test
105 °C; VR
Post test requirements
or 3 µA, whichever is greater
Diameter (mm) ≤ 6.3
8 ... 12.5
16
18
20 ...
25
ESL (nH)
26
34
40
15
20
> 2000 h
> 250000 h
∆C/C
tan δ
Ileak
> 3000 h
> 250000 h
≤ ±45% of initial value
≤ 3 times initial specified limit
≤ initial specified limit
1000 h
∆C/C
tan δ
Ileak
1000 h
≤ ±30% of initial value
≤ 2 times initial specified limit
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Displacement amplitude 1.5 mm, frequency range 10 ... 2000 Hz,
acceleration max. 20 g, duration 3 × 2 h.
Capacitor rigidly clamped by the aluminum case.
IEC climatic category
To IEC 60068-1:
VR ≤ 250 V: 40/105/56 (40 °C/+105 °C/56 days damp heat test)
VR ≥ 350 V: 25/105/56 (25 °C/+105 °C/56 days damp heat test)
Sectional specification
IEC 60384-4
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 36
B41851, B43851
Standard series 105 °C
Dimensional drawings
With stand-off rubber seal
Diameters (mm):
6.3, 10, 12.5, 16, 18, 22, 25
With flat rubber seal
Diameters (mm):
5, 8, 20
Safety vent for diameter ≥6.3 mm.
Dimensions and weights
Dimensions (mm)
d +0.5
5
6.3
8
10
10
10
12.5
12.5
16
16
16
18
18
18
20
20
22
25
l
11 +1.0
11 +1.0
11.5 +1.5
12.5 +1.0
16 +1.0
20 +2.0
20 +2.0
25 +2.0
20 +2.0
25 +2.0
31.5 +2.0
31.5 +2.0
35 +2.0
40 +2.0
35 +2.0
40 +2.0
40 +2.0
40 +2.0
Please read Cautions and warnings and
Important notes at the end of this document.
a ±0.5
2.0
2.5
3.5
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
7.5
10.0
10.0
10.0
12.5
Page 4 of 36
b
0.50 ±0.05
0.50 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
1.0 ±0.1
1.0 ±0.1
1.0 ±0.1
1.0 ±0.1
Approx. weight
g
0.5
0.7
1.0
1.6
1.9
2.6
3.6
4.5
5.5
7.5
7.8
11.0
13.0
16.0
18.0
20.0
23.0
25.0
B41851
Standard series 105 °C
Overview of available types B41851
Other voltage and capacitance ratings are available upon request.
VR (V DC)
6.3
10
16
25
Case dimensions d × l (mm)
CR (µF)
47
5
× 11
68
5
× 11
100
5
× 11
5
6.3 × 11
× 11
8
× 11.5
8
× 11.5
8
10
× 11.5
× 12.5
× 11.5
8
× 11.5
10
× 12.5
× 12.5
10
× 12.5
10
× 16
10
× 12.5
10
× 16
10
× 20
× 16
10
× 20
10
× 20
12.5 × 20
10
× 20
10
× 20
12.5 × 20
12.5 × 25
10
× 20
12.5 × 25
12.5 × 25
16 × 25
16
× 25
220
330
6.3 × 11
470
8
680
8
1000
6.3 × 11
6.3 × 11
8
× 11.5
× 11.5
8
× 11.5
10
10
× 12.5
1500
10
2200
3300
4700
12.5 × 25
16
× 20
16
× 25
16
× 31.5
6800
16
× 25
16
× 31.5
18
× 35
10000
18
× 31.5
18
× 35
20
× 40
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 36
B41851
Standard series 105 °C
VR (V DC)
35
50
63
100
Case dimensions d × l (mm)
CR (µF)
0.10
5
× 11
0.22
5
× 11
0.33
5
× 11
0.47
5
× 11
0.68
5
× 11
1.0
5
× 11
5
× 11
2.2
5
× 11
5
× 11
3.3
5
× 11
5
× 11
4.7
5
× 11
5
× 11
5
× 11
5
× 11
6.3 × 11
5
× 11
5
10
× 11
8
× 11.5
33
5
× 11
6.3 × 11
6.3 × 11
8
10
× 11.5
× 12.5
47
5
× 11
6.3 × 11
6.3 × 11
10
× 12.5
68
6.3 × 11
6.3 × 11
8
× 11.5
10
× 16
100
6.3 × 11
8
× 11.5
8
× 11.5
10
× 20
220
8
× 11.5
10
× 12.5
10
× 16
12.5 × 25
330
10
× 12.5
10
× 16
10
× 20
16
× 25
470
10
× 16
10
× 20
12.5 × 20
16
× 31.5
680
10
× 20
12.5 × 20
16
× 20
18
× 40
1000
12.5 × 20
12.5 × 25
16
× 25
18
× 40
1500
16
× 20
16
× 25
18
× 31.5
2200
16
× 25
16
18
× 31.5
× 35
18
× 35
3300
16
× 31.5
18
× 35
20
× 40
4700
18
× 35
20
× 40
25
× 40
6800
18
× 40
22
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 36
B43851
Standard series 105 °C
Overview of available types B43851
Other voltage and capacitance ratings are available upon request.
VR (V DC)
160
200
250
350
400
450
Case dimensions d × l (mm)
CR (µF)
0.47
6.3 × 11
6.3 × 11
0.68
6.3 × 11
6.3 × 11
1.0
6.3 × 11
6.3 × 11
6.3 × 11
6.3 × 11
2.2
6.3 × 11
6.3 × 11
6.3 × 11
6.3 × 11
8 × 11.5
3.3
6.3 × 11
6.3 × 11
6.3 × 11
8
4.7
6.3 × 11
6.3 × 11
8
× 11.5
8
× 11.5
10
× 12.5
10
8
× 11.5
8
× 11.5
× 11.5
8
× 11.5
10
× 12.5
× 11.5
10
× 12.5
10
× 12.5
× 16
10
× 20
10
× 20
10
8
× 11.5
8
22
10
10
× 12.5
× 16
10
× 16
10
× 20
12.5 × 20
12.5 × 25
33
10
10
× 16
× 20
10
× 20
12.5 × 20
12.5 × 25
16
× 20
16
× 25
47
10 × 20
12.5 × 20
12.5 × 20
12.5 × 25
16
× 25
16
× 25
16
× 31.5
12.5 × 25
68
12.5 × 20
12.5 × 25
16
× 25
16
× 31.5
18
× 31.5
18
× 35
100
12.5 × 25
16 × 25
16
× 25
16
× 31.5
18
× 35
18
× 40
20
× 40
220
16
18
× 31.5
× 31.5
18
× 31.5
18
× 40
330
18
× 35
20
× 35
22
× 40
470
20
× 40
22
× 40
680
25
× 40
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 36
B41851
Standard series 105 °C
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 6.3 V DC
330
6.3 × 11
470
8 × 11.5
680
8 × 11.5
1000
10 × 12.5
1500
10 × 16
2200
10 × 20
3300
10 × 20
4700
12.5 × 25
VR = 10 V DC
100
5 × 11
220
6.3 × 11
330
8 × 11.5
470
8 × 11.5
680
10 × 12.5
1000
10 × 12.5
1500
10 × 20
2200
10 × 20
3300
12.5 × 25
4700
16 × 20
6800
16 × 25
10000
18 × 31.5
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
1.4
1.0
0.68
0.46
0.31
0.23
0.16
0.12
195
265
295
455
525
710
840
1120
275
370
413
635
735
995
1175
1570
B41851A2337M***
B41851B2477M***
B41851F2687M***
B41851A2108M***
B41851F2158M***
B41851A2228M***
B41851A2338M***
B41851A2478M***
4.0
1.8
1.2
0.85
0.59
0.40
0.27
0.20
0.14
0.11
0.08
0.07
105
175
220
280
330
460
510
760
1085
1190
1575
1820
150
245
310
390
460
645
715
1065
1520
1665
2205
2250
B41851A3107M***
B41851A3227M***
B41851B3337M***
B41851A3477M***
B41851A3687M***
B41851A3108M***
B41851A3158M***
B41851A3228M***
B41851A3338M***
B41851A3478M***
B41851F3688M***
B41851F3109M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 36
B41851
Standard series 105 °C
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 16 V DC
100
5 × 11
220
6.3 × 11
330
8 × 11.5
470
8 × 11.5
680
10 × 12.5
1000
10 × 16
1500
10 × 20
2200
12.5 × 20
3300
12.5 × 25
3300
16 × 25
4700
16 × 25
6800
16 × 31.5
10000
18 × 35
VR = 25 V DC
47
5 × 11
68
5 × 11
100
6.3 × 11
220
8 × 11.5
330
8 × 11.5
330
10 × 12.5
470
10 × 12.5
680
10 × 16
1000
10 × 20
1500
12.5 × 20
2200
12.5 × 25
3300
16 × 25
4700
16 × 31.5
6800
18 × 35
10000
20 × 40
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
3.3
1.5
1.0
0.71
0.49
0.33
0.22
0.17
0.12
0.12
0.09
0.07
0.06
115
190
265
315
390
560
650
920
1170
1260
1500
1600
1950
160
265
370
440
545
785
910
1290
1640
1765
2100
2240
2730
B41851A4107M***
B41851F4227M***
B41851B4337M***
B41851K4477M***
B41851F4687M***
B41851A4108M***
B41851F4158M***
B41851F4228M***
B41851F4338M***
B41851A4338M***
B41851A4478M***
B41851F4688M***
B41851F4109M***
5.6
3.9
2.7
1.2
0.80
0.80
0.56
0.39
0.27
0.18
0.14
0.10
0.08
0.06
0.06
83
90
140
240
310
320
380
440
680
770
1090
1400
1700
1850
2050
116
126
195
335
435
450
530
615
950
1080
1525
1960
2380
2590
2870
B41851A5476M***
B41851F5686M***
B41851A5107M***
B41851B5227M***
B41851F5337M***
B41851A5337M***
B41851F5477M***
B41851F5687M***
B41851A5108M***
B41851F5158M***
B41851F5228M***
B41851A5338M***
B41851A5478M***
B41851F5688M***
B41851F5109M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 36
B41851
Standard series 105 °C
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 35 V DC
33
5 × 11
47
5 × 11
68
6.3 × 11
100
6.3 × 11
220
8 × 11.5
330
10 × 12.5
470
10 × 16
680
10 × 20
1000
12.5 × 20
1500
16 × 20
2200
16 × 25
3300
16 × 31.5
4700
18 × 35
6800
18 × 40
VR = 50 V DC
1
5 × 11
2.2
5 × 11
3.3
5 × 11
4.7
5 × 11
10
5 × 11
22
5 × 11
33
6.3 × 11
47
6.3 × 11
68
6.3 × 11
100
8 × 11.5
220
10 × 12.5
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
7.0
4.9
3.4
2.3
1.1
0.70
0.49
0.34
0.23
0.15
0.12
0.09
0.07
0.06
75
93
110
150
270
350
460
590
810
980
1260
1500
1780
2000
105
130
155
210
380
490
645
825
1135
1370
1765
2100
2490
2800
B41851A7336M***
B41851A7476M***
B41851A7686M***
B41851F7107M***
B41851F7227M***
B41851A7337M***
B41851A7477M***
B41851A7687M***
B41851F7108M***
B41851F7158M***
B41851F7228M***
B41851F7338M***
B41851K7478M***
B41851K7688M***
199
90
60
42
20
9.0
6.0
4.2
2.9
2.0
0.90
13
20
25
30
46
67
90
115
150
190
300
18
28
35
42
65
94
126
160
210
265
420
B41851A6105M***
B41851A6225M***
B41851A6335M***
B41851A6475M***
B41851B6106M***
B41851A6226M***
B41851A6336M***
B41851A6476M***
B41851F6686M***
B41851A6107M***
B41851A6227M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 36
B41851
Standard series 105 °C
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 50 V DC
330
10 × 16
470
10 × 20
680
12.5 × 20
1000
12.5 × 25
1500
16 × 25
2200
16 × 31.5
2200
18 × 35
3300
18 × 35
4700
20 × 40
VR = 63 V DC
10
5 × 11
22
5 × 11
33
6.3 × 11
47
6.3 × 11
68
8 × 11.5
100
8 × 11.5
220
10 × 16
330
10 × 20
470
12.5 × 20
680
16 × 20
1000
16 × 25
1500
18 × 31.5
2200
18 × 35
3300
20 × 40
4700
25 × 40
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
0.60
0.42
0.29
0.20
0.13
0.11
0.11
0.08
0.06
410
540
700
950
1260
1410
1540
1770
2100
575
755
980
1330
1765
1975
2155
2480
2940
B41851A6337M***
B41851A6477M***
B41851F6687M***
B41851F6108M***
B41851F6158M***
B41851F6228M***
B41851A6228M***
B41851K6338M***
B41851K6478M***
20
9.0
6.0
4.2
2.9
2.0
0.90
0.60
0.42
0.29
0.20
0.13
0.11
0.08
0.06
46
70
100
120
155
200
335
510
640
770
930
1260
1650
1950
2250
65
100
140
170
220
280
470
715
895
1080
1300
1765
2310
2730
3150
B41851A8106M***
B41851F8226M***
B41851A8336M***
B41851F8476M***
B41851F8686M***
B41851F8107M***
B41851A8227M***
B41851A8337M***
B41851F8477M***
B41851F8687M***
B41851F8108M***
B41851F8158M***
B41851K8228M***
B41851A8338M***
B41851F8478M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 36
B41851
Standard series 105 °C
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 100 V DC
0.1
5 × 11
0.22
5 × 11
0.33
5 × 11
0.47
5 × 11
0.68
5 × 11
1
5 × 11
2.2
5 × 11
3.3
5 × 11
4.7
5 × 11
10
6.3 × 11
22
8 × 11.5
33
8 × 11.5
33
10 × 12.5
47
10 × 12.5
68
10 × 16
100
10 × 20
220
12.5 × 25
330
16 × 25
470
16 × 31.5
680
18 × 40
1000
18 × 40
ESRmax
120 Hz
20 °C
Ω
1658
754
502
353
244
166
75
50
35
17
7.5
5.0
5.0
3.5
2.4
1.7
0.75
0.50
0.35
0.24
0.17
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
1.5
3.4
5.0
7.1
9.1
15
21
29
32
53
98
125
135
160
195
245
435
560
700
770
950
2.1
4.8
7.0
10
13
21
30
41
45
74
137
175
190
225
275
345
610
785
980
1080
1330
B41851A9104M***
B41851A9224M***
B41851A9334M***
B41851A9474M***
B41851A9684M***
B41851A9105M***
B41851A9225M***
B41851A9335M***
B41851A9475M***
B41851A9106M***
B41851B9226M***
B41851F9336M***
B41851A9336M***
B41851B9476M***
B41851A9686M***
B41851A9107M***
B41851A9227M***
B41851A9337M***
B41851A9477M***
B41851F9687M***
B41851F9108M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 36
B43851
Standard series 105 °C
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 160 V DC
1
6.3 × 11
2.2
6.3 × 11
3.3
6.3 × 11
4.7
6.3 × 11
10
8 × 11.5
22
10 × 12.5
22
10 × 16
33
10 × 16
33
10 × 20
47
10 × 20
47
12.5 × 20
68
12.5 × 20
100
12.5 × 25
100
16 × 25
220
16 × 31.5
220
18 × 31.5
330
18 × 35
470
20 × 40
680
25 × 40
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
186
85
56
40
18
13
8.4
7.5
5.6
4.9
4.5
3.0
2.3
1.8
0.95
0.84
0.70
0.42
0.34
16
23
28
35
56
91
108
125
143
150
188
250
300
332
532
560
695
910
1000
27
39
48
60
95
155
184
213
243
255
320
425
510
564
904
952
1182
1547
1700
B43851A1105M***
B43851A1225M***
B43851A1335M***
B43851F1475M***
B43851F1106M***
B43851F1226M***
B43851A1226M***
B43851F1336M***
B43851A1336M***
B43851K1476M***
B43851F1476M***
B43851K1686M***
B43851F1107M***
B43851A1107M***
B43851F1227M***
B43851A1227M***
B43851F1337M***
B43851F1477M***
B43851G1687M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 36
B43851
Standard series 105 °C
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 200 V DC
1
6.3 × 11
2.2
6.3 × 11
3.3
6.3 × 11
4.7
6.3 × 11
10
8 × 11.5
22
10 × 16
33
10 × 20
47
12.5 × 20
68
12.5 × 25
100
16 × 25
220
18 × 31.5
330
20 × 35
470
22 × 40
VR = 250 V DC
0.47
6.3 × 11
0.68
6.3 × 11
1
6.3 × 11
2.2
6.3 × 11
3.3
6.3 × 11
4.7
8 × 11.5
10
10 × 12.5
22
10 × 20
33
12.5 × 20
47
12.5 × 25
68
16 × 25
100
16 × 31.5
220
18 × 40
330
22 × 40
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
186
85
56
40
21
8.4
5.6
4.5
3.3
1.8
0.95
0.65
0.46
16
23
28
35
56
108
144
190
245
332
560
650
760
27
39
48
60
95
184
245
323
417
564
952
1105
1292
B43851A2105M***
B43851A2225M***
B43851A2335M***
B43851G2475M***
B43851G2106M***
B43851K2226M***
B43851B2336M***
B43851R2476M***
B43851K2686M***
B43851A2107M***
B43851B2227M***
B43851R2337M***
B43851R2477M***
395
273
186
85
65
40
23
8.4
5.6
4.3
2.7
1.8
0.84
0.56
11
13
16
23
35
38
66
120
161
203
266
364
476
658
19
22
27
39
60
65
112
204
274
345
452
619
809
1119
B43851F2474M***
B43851F2684M***
B43851F2105M***
B43851F2225M***
B43851K2335M***
B43851P2475M***
B43851K2106M***
B43851F2226M***
B43851K2336M***
B43851G2476M***
B43851F2686M***
B43851K2107M***
B43851F2227M***
B43851F2337M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 36
B43851
Standard series 105 °C
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 350 V DC
0.47
6.3 × 11
0.68
6.3 × 11
1
6.3 × 11
2.2
6.3 × 11
2.2
8 × 11.5
3.3
8 × 11.5
4.7
8 × 11.5
10
10 × 16
22
12.5 × 20
33
12.5 × 25
47
16 × 25
68
16 × 31.5
100
18 × 35
VR = 400 V DC
2.2
8 × 11.5
3.3
8 × 11.5
4.7
10 × 12.5
10
10 × 20
22
12.5 × 25
33
16 × 20
47
16 × 25
68
18 × 31.5
100
18 × 40
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
395
273
186
97
85
65
45
21
9.0
5.6
4.0
3.1
2.3
10
12
15
23
26
30
38
70
140
168
210
290
364
17
20
26
39
44
51
65
119
238
286
357
493
619
B43851A4474M***
B43851A4684M***
B43851A4105M***
B43851F4225M***
B43851B4225M***
B43851F4335M***
B43851F4475M***
B43851F4106M***
B43851F4226M***
B43851F4336M***
B43851F4476M***
B43851F4686M***
B43851F4107M***
97
65
46
18
8.4
5.6
4.0
3.3
1.9
26
36
56
80
140
168
196
294
310
44
61
95
136
238
286
333
500
527
B43851H9225M***
B43851F9335M***
B43851F9475M***
B43851A9106M***
B43851F9226M***
B43851F9336M***
B43851F9476M***
B43851A9686M***
B43851K9107M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 36
B43851
Standard series 105 °C
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
VR = 450 V DC
2.2
8 × 11.5
3.3
10 × 12.5
4.7
10 × 12.5
10
10 × 20
22
12.5 × 25
33
16 × 25
47
16 × 31.5
68
18 × 35
100
20 × 40
ESRmax
120 Hz
20 °C
Ω
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
97
65
45
26
14
7.6
4.8
2.7
1.8
20
28
32
56
100
125
155
193
207
34
48
54
95
170
213
264
328
352
Ordering code
(composition see
below)
B43851F5225M***
B43851F5335M***
B43851K5475M***
B43851F5106M***
B43851F5226M***
B43851F5336M***
B43851F5476M***
B43851A5686M***
B43851A5107M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm)
002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 36
B41851, B43851
Standard series 105 °C
Useful life
depending on ambient temperature TA under ripple current operating conditions1)
VR = 6.3 ... 100 V DC
VR = 160 ... 450 V DC
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 36
B41851, B43851
Standard series 105 °C
Frequency factor of permissible ripple
current IAC versus frequency f
VR ≤ 100 V DC
Please read Cautions and warnings and
Important notes at the end of this document.
Frequency factor of permissible ripple
current IAC versus frequency f
VR ≥ 160 V DC
Page 18 of 36
B41851, B43851
Standard series 105 °C
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 5 to 18 mm as follows:
Lead spacing F = 2.5 mm (∅ d = 5 … 6.3 mm)
Lead spacing F = 3.5 mm (∅ d = 8 mm)
Lead spacing F = 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm)
Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm).
Lead spacing 2.5 mm (∅ d = 5 ... 6.3 mm)
Last 3 digits of ordering code: 007
Dimensions in mm
∅d
5
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0
6.3
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2
ance 0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 19 of 36
B41851, B43851
Standard series 105 °C
Lead spacing 3.5 mm (∅ d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
∅d
8
Tolerance
F
H
W
W0
W1
W2
P
P0
P1
I1
t
∆h
3.5
18.5
18.0
12.5
9.0
1.5
12.7
12.7
4.6
1.0
0.7
1.0
+0.8
±1.0
0.2
±0.5
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 36
D0
4.0
max. ±0.2
B41851, B43851
Standard series 105 °C
Lead spacing 5.0 mm (∅ d = 5 ... 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
∅d
5
6.3
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
5.0
18.5
18.0 5.5
9.0
1.5
16.0
12.7
12.7
3.85
1.0
0.7
1.0
4.0
16.0
12.7
12.7
3.85
18.0 12.5 9.0
1.5
12.7
12.7
3.85
1.0
0.7
1.0
4.0
15.0
15.0
5.0
±1.0
±0.2
±0.5
8
10
20.0
5.0
19.0
12.5
19.0
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5
ance 0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 21 of 36
max. ±0.2 max. ±0.2
B41851, B43851
Standard series 105 °C
Lead spacing 7.5 mm (∅ d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
∅d
16
F
H
W
7.5 18.5 18.0
18 *)
Toler0.5
±0.8
±0.5
ance
+0.75
W0
W1
W2
P
P0
P1
I1
t
∆P
∆h
D0
12.5
9.0
1.5
30.0
15.0
3.75
1.0
0.7
0
0
4.0
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2 ±1.0 ±1.0 ±0.2
*) Available only for case dimensions 18 × 20, 18 × 25 and 18 × 31.5 mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 22 of 36
B41851, B43851
Standard series 105 °C
Packing units and box dimensions
Ammo pack
Please read Cautions and warnings and
Important notes at the end of this document.
Case size
d×l
mm
Dimensions (mm)
Amax
Bmax
Cmax
5 × 11
345
55
240
2000
6.3 × 11
345
55
290
2000
8 × 11.5
345
55
240
1000
10 × 12.5
345
55
280
750
10 × 16
345
60
200
500
10 × 20
345
60
200
500
12.5 × 20
345
65
280
500
12.5 × 25
345
65
280
500
16 × 20
315
65
275
300
16 × 25
315
65
275
300
16 × 31.5
315
65
275
300
18 × 20
315
65
275
250
18 × 25
315
65
275
250
18 × 31.5
315
65
275
250
Page 23 of 36
Packing
units
pcs.
B41851, B43851
Standard series 105 °C
Kinked or cut leads
Single-ended capacitors are available with kinked or cut leads. Other lead configurations also
available upon request.
Kinked leads
Last 3 digits of ordering code: 001
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 24 of 36
Dimensions (mm)
a ±0.5
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
B41851, B43851
Standard series 105 °C
Cut leads
Last 3 digits of ordering code: 002
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 25 of 36
Dimensions (mm)
a ±0.5
10 × 12.5
5.0
10 × 16
5.0
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
20 × 20
10.0
20 × 25
10.0
20 × 30
10.0
20 × 35
10.0
20 × 40
10.0
22 × 30
10.0
22 × 35
10.0
22 × 40
10.0
B41851, B43851
Standard series 105 °C
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 20 mm.
There are three configurations available: Crimped leads, J leads, bent 90° leads
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal
With flat rubber seal
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
B ±0.2
C ±0.5
D ±0.1
E ±0.1
16 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
18 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 35
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 40
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
20 × 20
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 25
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 30
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 35
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 40
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 26 of 36
a ±0.5
∅b
B41851, B43851
Standard series 105 °C
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
J ±0.2
10 × 12.5
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 16
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 25
3.2
0.7
1.2
5.0
0.6 ±0.05
16 × 20
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 25
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.05
18 × 20
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 25
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 35
3.5
0.7
1.6
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 27 of 36
a ±0.5
∅b
B41851, B43851
Standard series 105 °C
Bent 90° leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
F ±0.5
a ±0.5
∅b
16 × 20
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 25
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 31.5
4.0
4.0
12.0
7.5
0.8 ±0.05
18 × 20
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 25
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 31.5
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 35
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 40
4.0
4.0
13.0
7.5
0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 28 of 36
B41851, B43851
Standard series 105 °C
Overview of packing units and code numbers for case sizes 5 × 11 ... 16 × 31.5
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
2000
5 × 11
2000
6.3 × 11
2500
2000
8 × 11.5
1000
1000
10 × 12.5
1000
750
10 × 16
1000
500
1000
10 × 20
500
500
500
500
12.5 × 20
350
500
350
350
12.5 × 25
250
500
500
500
12.5 × 30
200
12.5 × 35
175
12.5 × 40
175
16 × 20
250
300
200
200
200
200
120
16 × 25
250
300
200
200
200
200
120
16 × 31.5
200
300
250
250
344
344
120
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code
006
007
008
009
001
002
003
004
012
F (mm) d (mm)
3.5
2.5
5
7.5
8
5...6.3
5...12.5
16...18
1) Available upon request
Please read Cautions and warnings and
Important notes at the end of this document.
Page 29 of 36
1000
Bent 90°
leads,
blister
pcs.
675
675
500
300
1)
225
1)
B41851, B43851
Standard series 105 °C
Overview of packing units and code numbers for case sizes 18 × 20 ... 25 × 40
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
Bent 90°
leads,
blister
pcs.
18 × 20
175
18 × 25
150
250
175
175
200
200
120
250
150
150
200
200
18 × 31.5
120
100
250
100
100
150
150
120
18 × 35
100
100
100
150
150
150
18 × 40
125
100
100
120
72
20 × 20
125
125
200
20 × 25
125
125
200
20 × 30
100
100
120
20 × 35
100
100
120
20 × 40
100
100
120
22 × 30
80
100
22 × 35
80
22 × 40
80
25 × 40
40
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code
007
008
009
Please read Cautions and warnings and
Important notes at the end of this document.
F (mm) d (mm)
2.5
5
7.5
100
100
001
002
4...6.3
6.3...12.5
16...18
Page 30 of 36
003
004
012
B41851, B43851
Standard series 105 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 31 of 36
B41851, B43851
Standard series 105 °C
Product safety
The table below summarize the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Safety information
Polarity
Make sure that polar capacitors are connected
with the right polarity.
Reverse voltage
Voltages polarity classes should be prevented by
connecting a diode.
Do not exceed the upper category temperatur.
Upper category
temperature
Maintenance
Mounting
position of screw
terminal capacitors
Mounting of
single-ended
capacitors
Robustness of
terminals
Soldering
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
Do not mount the capacitor with the terminals
(safety vent) upside down.
Reference
Chapter "General
technical information"
1
"Basic construction of
aluminum electrolytic
capacitors"
3.1.6
"Reverse voltage"
7.2
"Maximum permissible
operating temperature"
10
"Maintenance"
11.1
"Mounting positions of
capacitors with screw
terminals"
The internal structure of single-ended capacitors 11.4
might be damaged if excessive force is applied to "Mounting
the lead wires.
considerations for
Avoid any compressive, tensile or flexural stress. single-ended capacitors"
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
The following maximum tightening torques must
11.3
not be exceeded when connecting screw
"Mounting torques"
terminals:
M5: 2 Nm
M6: 2.5 Nm
Do not exceed the specified time or temperature 11.5
limits during soldering.
"Soldering"
Please read Cautions and warnings and
Important notes at the end of this document.
Page 32 of 36
B41851, B43851
Standard series 105 °C
Topic
Soldering,
cleaning agents
Passive
flammability
Active
flammability
Safety information
Reference
Chapter "General
technical information"
Do not allow halogenated hydrocarbons to come 11.6
into contact with aluminum electrolytic capacitors. "Cleaning agents"
Avoid external energy, such as fire or electricity.
8.1
"Passive flammability"
Avoid overload of the capacitors.
8.2
"Active flammability"
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Please read Cautions and warnings and
Important notes at the end of this document.
Page 33 of 36
Reference
Chapter "Capacitors
with screw terminals"
"Screw terminals accessories"
B41851, B43851
Standard series 105 °C
Symbols and terms
Symbol
English
German
C
CR
CS
CS,T
Cf
d
dmax
ESL
ESR
ESRf
Capacitance
Rated capacitance
Series capacitance
Series capacitance at temperature T
Capacitance at frequency f
Case diameter, nominal dimension
Maximum case diameter
Self-inductance
Equivalent series resistance
Equivalent series resistance at
frequency f
Equivalent series resistance at
temperature T
Frequency
Current
Alternating current (ripple current)
Root-mean-square value of alternating
current
Ripple current at frequency f
Maximum permissible ripple current
Rated ripple current
Rated ripple current for base cooling
Leakage current
Operating leakage current
Case length, nominal dimension
Maximum case length (without
terminals and mounting stud)
Resistance
Insulation resistance
Balancing resistance
Temperature
Temperature difference
Ambient temperature
Case temperature
Capacitor base temperature
Time
Period
Service life (operating hours)
Kapazität
Nennkapazität
Serienkapazität
Serienkapazität bei Temperatur T
Kapazität bei Frequenz f
Gehäusedurchmesser, Nennmaß
Maximaler Gehäusedurchmesser
Eigeninduktivität
Ersatzserienwiderstand
Ersatzserienwiderstand bei Frequenz f
ESRT
f
I
IAC
IAC,rms
IAC,f
IAC,max
IAC,R
IAC,R (B)
Ileak
Ileak,op
l
lmax
R
Rins
Rsymm
T
∆T
TA
TC
TB
t
∆t
tb
Please read Cautions and warnings and
Important notes at the end of this document.
Ersatzserienwiderstand bei Temperatur T
Frequenz
Strom
Wechselstrom
Wechselstrom, Effektivwert
Wechselstrom bei Frequenz f
Maximal zulässiger Wechselstrom
Nennwechselstrom
Nennwechselstromstrom für Bodenkühlung
Ableitstrom
Ableitstrom bei Betrieb
Gehäuselänge, Nennmaß
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
Widerstand
Isolationswiderstand
Symmetrierwiderstand
Temperatur
Temperaturdifferenz
Umgebungstemperatur
Gehäusetemperatur
Temperatur des Becherbodens
Zeit
Zeitraum
Brauchbarkeitsdauer (Betriebszeit)
Page 34 of 36
B41851, B43851
Standard series 105 °C
Symbol
V
VF
Vop
VR
VS
XC
XL
Z
ZT
tan δ
λ
ε0
εr
ω
English
Voltage
Forming voltage
Operating voltage
Rated voltage, DC voltage
Surge voltage
Capacitive reactance
Inductive reactance
Impedance
Impedance at temperature T
Dissipation factor
Failure rate
Absolute permittivity
Relative permittivity
Angular velocity; 2 π f
German
Spannung
Formierspannung
Betriebsspannung
Nennspannung, Gleichspannung
Spitzenspannung
Kapazitiver Blindwiderstand
Induktiver Blindwiderstand
Scheinwiderstand
Scheinwiderstand bei Temperatur T
Verlustfaktor
Ausfallrate
Elektrische Feldkonstante
Dielektrizitätszahl
Kreisfrequenz; 2 π f
Notes
All dimensions are given in mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 35 of 36
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP,
MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT,
SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse,
WindCap are trademarks registered or pending in Europe and in other countries. Further
information will be found on the Internet at www.epcos.com/trademarks.
Page 36 of 36