DTMPU15 Series 15 Watt Single Output For Medical Equipment AC/DC Desktop Power Supply Rev. B FEATURES ● Splash Proof ● Single Output ● 3 Year Warranty ● Optional Output Connectors ● Over Temperature Detection ● A & C Types: Class I Insulation ● 3 Types of Inlet Connectors Available ● Over Voltage and Over Load Protection ● Wide Input Voltage 90 to 264VAC, 47~63Hz ● B Type: Class II Insulation (Double Insulation) ● Output Voltages Available from 5VDC to 36VDC SPECIFICATIONS: DTMPU15 Series Type A Type B Type C o All specifications are based on 25 C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION INPUT (Vin) Operating Voltage Range Input Frequency Input Current (Low Line) Input Current (High Line) Inrush Current (Low Line) Inrush Current (High Line) Safety Ground Leakage Current Start-Up Time OUTPUT (Vo) Output Voltage Range Load Regulation Line Regulation Output Power Range Output Current Range Ripple & Noise (peak to peak) Transient Response Hold-Up Time PROTECTION (1) Over Voltage Protection (1) Over Current Protection GENERAL Efficiency Dielectric Withstanding Voltage For Primary to Secondary Dielectric Withstanding Voltage For Primary to Ground (A & C Types Only) Isolation Resistance Power Consumption (No Load) ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Temperature Coefficient Thermal Shutdown by Junction (1) Temperature Controller MTBF PHYSICAL Weight TEST CONDITIONS Nom Max Unit 0.25 0.17 14 28 264 63 0.33 0.18 16 30 0.3 1 VAC Hz A A A A mA s 90 47 Io = Full Load, Vin = 115VAC Io = Full Load, Vin = 230VAC Io = Full Load, 25°C, Cool Start, Vin = 115VAC Io = Full Load, 25°C, Cool Start, Vin = 230VAC Io = Full Load, Vin = 240VAC Io = Full Load, Vin = 100VAC Vin = 230VAC Io = Full Load Vin = 90 to 264VAC Full Load, Vin = 90VAC Io = Full Load to Half Load, Vin = 100VAC Io = Full Load, Vin = 110VAC Io = Full Load, Vin = 230VAC 0.5 See Rating Chart 3 5 0.5 1 0 15 See Rating Chart 0.5 1 4 10 16 1 VDC % % W A % ms ms 112 110 132 150 % % 73 85 % Primary to Secondary 5600 VDC Primary to Ground 2800 VDC Test Voltage = 500VDC No Load, Vin = 230VAC Derate linearly from 100% Load at 50°C to 50% load at 70°C All Outputs The parameter is not subject to production test-verified by design/characterization of integrated controller. Operating temperature at 25°C, calculated per MIL-HDBK-217F 50 0 0 -40 5 -0.04 0.4 0.5 MΩ W 50 70 85 95 +0.04 °C °C % %/°C +125 °C -20 100,000 hours Approximately 170 grams A Type: 4.11 x 1.65 x 1.22 inches B & C Types: 3.90 x 1.65 x 1.22 inches IEC-320-C14, IEC-320-C8, IEC-320-C6 3 years Dimensions Input Inlet Warranty SAFETY EMI Requirements for EN55022 EMI Requirements for FCC Part-15, FCC Part 18 Min Vin = 230VAC, 50Hz B Class Vin = 120VAC, 60Hz B Class (1) When the power system interruption is isolated, the product would re-start after recovering by hand. Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU15 Series 15 Watt Single Output For Medical Equipment AC/DC Desktop Power Supply Rev. B OUTPUT VOLTAGE/ CURRENT RATING CHART Model Number Output Voltage Output Current Total Regulation (2) Maximum Output Power DTMPU15x-102 5 VDC 2.60A 5% 13W DTMPU15x-103 7 VDC 1.85A 5% 13W DTMPU15x-104 9 VDC 1.66A 5% 15W DTMPU15x-105 12 VDC 1.25A 5% 15W DTMPU15x-106 16 VDC 0.93A 5% 15W DTMPU15x-107 18 VDC 0.83A 5% 15W DTMPU15x-108 24 VDC 0.62A 3% 15W DTMPU15x-109 30 VDC 0.50A 3% 15W DTMPU15x-110 36 VDC 0.41A 3% 15W NOTES 1. The DTMPU15 Series is designated as DTMPU15x-y where x represents the type of AC input inlet connector which can either be A (IEC-320-C14), B (IEC-320-C8), or C (IEC-320-C6); y can be 102, 103, 104, 105, 106, 107, 108, 109, or 110 for output voltage. 2. Models DTMPU15-102, 103, and 105 needs to use AWG#16/4FT output cable in order to meet the total regulation. Models DTMPU15-104, 106~110 needs to use AWG#18/4FT output cable in order to meet the total regulation. The regulation and efficiency will change if a different output cable is used. 3. Optional output connectors are available (see “DC Output Plug Selector List” link located at the bottom of the “Desktop” category page). DERATING CURVE Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Rev. B MECHANICAL DRAWINGS TYPE A Unit: inches [mm] TYPES B & C Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU15 Series 15 Watt Single Output For Medical Equipment AC/DC Desktop Power Supply