Series AM2LP-NZ 2 Watt | DC-DC Converter FEATURES: SMD Package Single Output Models Low Ripple and Noise High efficiency up to 81% Operating temperature -40oC to + 85oC Input / Output Isolation 1000 VDC Pin compatible with multiple manufacturers RoHS compliant Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 5 12 15 5 12 15 5 12 15 24 400 167 133 400 167 133 400 167 133 84 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 78 79 80 78 80 81 78 80 81 80 AM2LP-0505S-NZ AM2LP-0512S-NZ AM2LP-0515S-NZ AM2LP-1205S-NZ AM2LP-1212S-NZ AM2LP-1215S-NZ AM2LP-2405S-NZ AM2LP-2412S-NZ AM2LP-2415S-NZ AM2LP-2424S-NZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 5 12 24 Maximum 4.5-5.5 10.8-13.2 21.6-26.4 Capacitor Filter Units VDC Isolation Specifications Parameters Tested I/O voltage Resistance Conditions Typical 60 sec 500Vdc >1000 Conditions Typical Rated Units 1000 VDC MOhm Maximum Units Output Specifications Parameters Voltage accuracy Short Circuit protection Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Minimum Load Current See the tolerance graph ±5 Momentary (1sec) 1.2 10 ±0.03 150 10 For 1.0% of Vin Load 10 – 100% 20MHz Bandwidth % % of Vin % %/oC mV p-p % of Max If the operating output current is less than 10% of maximum it is recommended to install a load resistor in parallel with the load to ensure the actual load current meets the minimum load current requirement. General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling www.aimtec.com F 051e R12.A Conditions Typical 100% load Without derating 500 Maximum Units +95 KHz o C o C o C -40 to +85 -55 to +125 Free air convection Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LP-NZ 2 Watt | DC-DC Converter General Specifications (continued) Parameters Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Conditions Single 1 2 3 4 5 6 7 8 - V Input + V Input N. C. - V Output .+V Output N.C. N.C. N.C. Maximum Units 95 % RH Plastic UL94-VO 1.41 0.50 x 0.30 x 0.24 inches 12.70 x 11.20 x 6.50 mm > 3,500,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC) 1.5mm from case for 10 sec 260 Pin Out Specifications Pin Typical Dimensions o C Front View 6.70 (0.26) Side View 4.13 (0.16) A 6.00 6.25 (0.24) (0.25) 0.30 (0.01) 0.25 (0.01) 1.85 (0.07) Top View N.C: Not Connected g 7.00 (0.28) A 12.70 (0.50) 0.50 (0.02) 11.20 7.50 (0.44) (0.30) 5.00º angle 1 1.50 (0.06) 0.60 (0.024) 2.54 (0.10) All dimensions are in mm (inch) All Pins are on a 2.54mm (0.10inch) pitch with tolerance of ±0.25mm (0.01inch) Tolerance Graph +10% Recommended Filter Circuit Typical Load Line + Vin +5% Nominal Voltage -2.5% + Cin + DC -7.5% 50% Output Current(%) DC Cout - Vin - Vin www.aimtec.com F 051e R12.A +Vout +2.5% Output Voltage 10% L Single Output L 100% Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LP-NZ 2 Watt | DC-DC Converter If it is required to decrease the input/output ripple, an “LC” filter network can be installed on the input and output of the converter (see above). It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC converter switching frequency to avoid mutual interference. The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems and ensure safe and reliable operation. It’s not recommended to connect any external capacitor in the application field when output loading is less than 0.5 watt. External Capacitor Tables Input Capacitor (Cin) Vin Cin (VDC) (uF) 5 12 24 4.7 2.2 0.47 Output Capacitor (Cout) Single Vout Cout (VDC) (uF) 5 12 15 24 10 2.2 1 0.47 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only