Chinfa DRA10-24A Ac - dc din rail mountable 10w class 2 power supply industrial control equipment Datasheet

DRA10 SERIES
AC - DC DIN RAIL MOUNTABLE
10W CLASS 2 POWER SUPPLY
INDUSTRIAL CONTROL EQUIPMENT
FEATURES
UL / cUL / TUV / CE
UNIVERSAL INPUT 90~265VAC
HIGH EFFICIENCY UP TO 76%
SHORT CIRCUIT PROTECTION
INTERNAL INPUT FILTER
2 YEARS WARRANTY
MODEL LIST
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
+ 5 VDC
2000 mA
71%
73%
10 WATTS
+ 12 VDC
840 mA
73%
75%
10 WATTS
+ 15 VDC
670 mA
74%
76%
10 WATTS
+ 24 VDC
420 mA
74%
76%
max.
unit
MODEL NO.
INPUT
VOLTAGE
DRA10-05
90~265 VAC
10 WATTS
DRA10-12
90~265 VAC
DRA10-15
90~265 VAC
DRA10-24
90~265 VAC
OUTPUT
OUTPUT
WATTAGE
VOLTAGE
Single Output Models
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
GENERAL
Characteristics
Conditions
min.
KHz
3,000
VAC
Vi nom, Io nom
Isolation voltage
Input / Output
Isolation resistance
Input / Output, @ 500VDC
100
Ambient temperature
Operating at Vi nom
-20
o
typ.
100
Switching frequency
M
o
+ 71
o
3
o
Derating
Vi nom,from +61 C to +71 C
Storage temperature
Non operational
-25
+ 85
Relative humidity
Vi nom, Io nom
20
95
Dimension
L90 x W22.5 x D115
Cooling
Free air convection
Case material
Plastic
C
%/ C
o
C
% RH
mm
INPUT SPECIFICATIONS
Characteristics
Conditions
Rated input voltage
Io nom
Input voltage range
Ta min ... Ta max,
Io nom
Line frequency
Vi nom, Io nom
Inrush current
Io nom
www.chinfa.com
2008.08.19
min.
typ.
max.
unit
100
240
VAC
AC in
90
265
VAC
DC in
120
370
VDC
47
63
Hz
Vi : 115VAC
10
A
Vi : 230VAC
18
A
[email protected]
DRA10 SERIES
IND. CONT. EQ.
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
typ.
max.
unit
1
%
Vi nom, Io min ...Io nom
Output voltage accuracy
0
%
Minimum load
Vi nom
Line regulation
Io nom, Vi min ...Vi max
1
%
Load regulation
Vi nom, Io min ...Io nom
2
%
Transient recovery time
50% load, step changed
S
300
o
0.02
% / C
50
mV
Temperature coefficient
Vi nom, Io min
Ripple & noise
Vi nom, Io nom,BW = 20MHz
Hold up time
Io nom
Vi = 230VAC
100
Voltage trim range
Vi nom, Io nom
5V ...15V models
- 10
+ 15
%
Vi nom, Io nom
24V model
5V model
- 10
4.5
+ 20
DC ON indicator
threshold at start up
%
VDC
12V model
10.8
VDC
15V model
13.5
VDC
24V model
21.6
5V model
3.75
4.5
VDC
12V model
9
10.8
VDC
15V model
11.25
13.5
VDC
18
21.6
VDC
max.
unit
Vi = 115VAC
Vi nom, Io nom
DC LOW indicator
threshold after start up
24V model
Efficiency
Vi nom, Io nom, Po / Pi
25
ms
ms
VDC
Up to 76%, See model list
CONTROL AND PROTECTION
Characteristics
Conditions
min.
typ.
T2A / 250VAC internal
Input fuse
Rated over load protection
Vi nom
Over voltage protection
Output short circuit
110
145
%
Vi nom, Io nom
125
145
%
Vi nom, Io nom
Hiccup mode
APPROVALS AND STANDARDS
UL / cUL
UL508 Listed
UL60950-1, UL1310 Class 2 Power Supply Recognized
TUV
EN60950-1
CE
EN61000-6-3 / EN55022 Class B, EN61000-3-2 , EN61000-3-3
EN61000-6-2 / EN55024 / EN61204-3
CIRCUIT SCHEMATIC
Block diagram for DRA10 series
L
Fuse
Line
Filter
N
Y
Inrush Current
Switching
Limiter and
Device
Rectifier
Control
Vo +
Rectifier
Current
Detection
Opto Isolation
Reference &
Error Amp.
Opto Isolation
Over Voltage
Detection
Output Level
Detection
www.chinfa.com
2008.08.19
Vo -
Vout
ADJ.
DC ON
(Green LED)
DC LOW
(Red LED)
[email protected]
DRA10 SERIES
IND. CONT. EQ.
MECHANISM & PIN CONFIGURATION
mm [inch]
22.5 [0.89]
115 [4.53]
2 1
CONSTRUCTION
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safely and
firmly on the rail; no tools required even to remove
V- V+
DC Output
LO
INSTALLATION
90.0 [3.60]
ON
Ventilation / Cooling
Normal convection
All sides 25mm free space
For cooling recommended
Connector size range
Solid:0.2-2.0mm2(AWG24-14)
(use copper conductors only)
Vout ADJ.
N L
3 4 5
PHYSICAL CHARACTERISTICS
CASE SIZE
90 x 22.5 x 115 mm 3.6 x 0.89 x 4.53 inches
CASE MATERIAL
Plastic
WEIGHT
120 g
PIN ASSIGNMENT
Designation
1
2
OUT
PIN NO.
Description
V+
Positive output terminal
V -
Negative output terminal
Ground this terminal to minimize high-frequency emissions
4
IN
3
OTHER
5
N
Input terminals (neutral conductor, no polarity at DC input)
L
Input terminals (phase conductor, no polarity at DC input)
ON
Operation indicator LED
LO
DC LOW indicator LED
Trimmer- potentiometer for Vout adjustment
Vout ADJ.
DERATING
Power out [ % ]
100
70
0
-20
61
71
Temperature [ oC ]
www.chinfa.com
2008.08.19
[email protected]
DRA10 SERIES
AC - DC DIN RAIL MOUNTABLE
10W CLASS 2 POWER SUPPLY
INDUSTRIAL CONTROL EQUIPMENT
FEATURES
UL / cUL / TUV / CE
UNIVERSAL INPUT 90~265VAC
HIGH EFFICIENCY UP TO 76%
SHORT CIRCUIT PROTECTION
INTERNAL INPUT FILTER
2 YEARS WARRANTY
MODEL LIST
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
+ 5 VDC
2000 mA
71%
73%
10 WATTS
+ 12 VDC
840 mA
73%
75%
10 WATTS
+ 15 VDC
670 mA
74%
76%
10 WATTS
+ 24 VDC
420 mA
74%
76%
max.
unit
MODEL NO.
INPUT
VOLTAGE
DRA10-05A
90~265 VAC
10 WATTS
DRA10-12A
90~265 VAC
DRA10-15A
90~265 VAC
DRA10-24A
90~265 VAC
OUTPUT
OUTPUT
WATTAGE
VOLTAGE
Single Output Models
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
GENERAL
Characteristics
Conditions
min.
KHz
3,000
VAC
Vi nom, Io nom
Isolation voltage
Input / Output
Isolation resistance
Input / Output, @ 500VDC
100
Ambient temperature
Operating at Vi nom
-20
o
typ.
100
Switching frequency
M
o
+ 71
o
3
o
Derating
Vi nom,from +61 C to +71 C
Storage temperature
Non operational
-25
+ 85
Relative humidity
Vi nom, Io nom
20
95
Dimension
L90 x W22.5 x D115
Cooling
Free air convection
Case material
Plastic
C
%/ C
o
C
% RH
mm
INPUT SPECIFICATIONS
Characteristics
Conditions
Rated input voltage
Io nom
Input voltage range
Ta min ... Ta max,
Io nom
Line frequency
Vi nom, Io nom
Inrush current
Io nom
www.chinfa.com
2008.08.19
min.
typ.
max.
unit
100
240
VAC
AC in
90
265
VAC
DC in
120
370
VDC
47
63
Hz
Vi : 115VAC
10
A
Vi : 230VAC
18
A
[email protected]
DRA10 SERIES
IND. CONT. EQ.
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
typ.
max.
unit
1
%
Vi nom, Io min ...Io nom
Output voltage accuracy
0
%
Minimum load
Vi nom
Line regulation
Io nom, Vi min ...Vi max
1
%
Load regulation
Vi nom, Io min ...Io nom
2
%
Transient recovery time
50% load, step changed
S
300
o
0.02
% / C
50
mV
Temperature coefficient
Vi nom, Io min
Ripple & noise
Vi nom, Io nom,BW = 20MHz
Hold up time
Io nom
Vi = 230VAC
100
Voltage trim range
Vi nom, Io nom
5V ...15V models
- 10
+ 15
%
Vi nom, Io nom
24V model
5V model
- 10
4.5
+ 20
DC ON indicator
threshold at start up
%
VDC
12V model
10.8
VDC
15V model
13.5
VDC
24V model
21.6
5V model
3.75
4.5
VDC
12V model
9
10.8
VDC
15V model
11.25
13.5
VDC
18
21.6
VDC
max.
unit
Vi = 115VAC
Vi nom, Io nom
DC LOW indicator
threshold after start up
24V model
Efficiency
Vi nom, Io nom, Po / Pi
25
ms
ms
VDC
Up to 76%, See model list
CONTROL AND PROTECTION
Characteristics
Conditions
min.
typ.
T2A / 250VAC internal
Input fuse
Rated over load protection
Vi nom
Over voltage protection
Output short circuit
110
145
%
Vi nom, Io nom
125
145
%
Vi nom, Io nom
Hiccup mode
APPROVALS AND STANDARDS
UL / cUL
UL508 Listed
UL60950-1, UL1310 Class 2 Power Supply Recognized
TUV
EN60950-1
CE
EN61000-6-3 / EN55022 Class B, EN61000-3-2 , EN61000-3-3
EN61000-6-2 / EN55024 / EN61204-3
CIRCUIT SCHEMATIC
Block diagram for DRA10 series
L
Fuse
Line
Filter
N
Y
Inrush Current
Switching
Limiter and
Device
Rectifier
Control
Vo +
Rectifier
Current
Detection
Opto Isolation
Reference &
Error Amp.
Opto Isolation
Over Voltage
Detection
Output Level
Detection
www.chinfa.com
2008.08.19
Vo -
Vout
ADJ.
DC ON
(Green LED)
DC LOW
(Red LED)
[email protected]
DRA10 SERIES
IND. CONT. EQ.
MECHANISM & PIN CONFIGURATION
mm [inch]
22.5 [0.89]
115 [4.53]
2 1
CONSTRUCTION
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safely and
firmly on the rail; no tools required even to remove
V- V+
DC Output
INSTALLATION
90.0 [3.60]
LO
ON
Ventilation / Cooling
Normal convection
All sides 25mm free space
For cooling recommended
Connector size range
Solid:0.2-2.0mm2(AWG24-14)
(use copper conductors only)
Vout ADJ.
N L
3 4 5
PHYSICAL CHARACTERISTICS
90 x 22.5 x 115 mm 3.6 x 0.89 x 4.53 inches
CASE SIZE
CASE MATERIAL
Plastic
WEIGHT
120 g
PIN ASSIGNMENT
Designation
1
2
OUT
PIN NO.
Description
V+
Positive output terminal
V -
Negative output terminal
Ground this terminal to minimize high-frequency emissions
4
IN
3
OTHER
5
N
Input terminals (neutral conductor, no polarity at DC input)
L
Input terminals (phase conductor, no polarity at DC input)
ON
Operation indicator LED
LO
DC LOW indicator LED
Trimmer- potentiometer for Vout adjustment
Vout ADJ.
DERATING
Power out [ % ]
100
70
0
-20
61
71
Temperature [ oC ]
www.chinfa.com