XP Power EMH350PS12D 250 w & 350 w forced-cooled Datasheet

EMH Series
•
250 W & 350 W Forced-cooled
•
Industry Standard 3”x 5”x 1.43”Format
•
IT & Medical (BF) Approvals
•
80 V - 275 VAC Operation
•
Optional ORing Diode (EMH350D Models)
•
Analog & PMBus Signals Options (EMH350)
•
5 V Standby (EMH350)
•
3 Year Warranty
The EMH series of ultra compact high power density supplies deliver 250 W and 350W within the industry standard
3” x 5” (76mm x 127mm) footprint. They achieve this very high power density with a minimal 12 CFM forced air
requirement and a profile of just 1.4” (36 mm) making them suitable for 1U and a host of other applications.
All models feature a main output and 12V/0.6A fan supply output along with IEC60950 (IT) and IEC60601 BF (Medical)
family safety approvals, thus including patient contact equipment in the wide range of possible applications.
The EMH350 has a 5V/2A standby rail and can be supplied with a range of optional analogue and digital, PMBus
compatible signals as well as a variable speed fan & cover. The EMH350D models have built in Oring diodes for use in
redundant applications.
xppower.com
and
Ratings
Models &
Ratings
Output Voltage V1
12 V
18 V
24 V
48 V
Output Current V1
21.0 A
14.0 A
10.5 A
5.2 A
Fan Supply V3(1)
12 V/0.6 A
12 V/0.6 A
12 V/0.6 A
12 V/0.6 A
Output Voltage V1
12 V
18 V
24 V
48 V
Output Current V1
29.2 A
19.5 A
14.6 A
7.3 A
Standby Supply V2
5.0 V / 2.0 A
5.0 V / 2.0 A
5.0 V / 2.0 A
5.0 V / 2.0 A
Output Voltage V1
12 V
18 V
24 V
48 V
Output Current V1
29.2 A
19.5 A
14.6 A
7.3 A
Standby Supply V2
5.0 V / 2.0 A
5.0 V / 2.0 A
5.0 V / 2.0 A
5.0 V / 2.0 A
Output Power
252 W
252 W
252 W
250 W
Model Number(1)
EMH250PS12
EMH250PS18
EMH250PS24
EMH250PS48
Fan Supply V3(2)
12 V/0.6 A
12 V/0.6 A
12 V/0.6 A
12 V/0.6 A
Output Power
354 W
354 W
355 W
354 W
Model Number(2)
EMH350PS12
EMH350PS18
EMH350PS24
EMH350PS48
Fan Supply V3
12 V/0.6 A
12 V/0.6 A
12 V/0.6 A
12 V/0.6 A
Output Power
354 W
354 W
355 W
354 W
Model Number(3)
EMH350PS12D
EMH350PS18D
EMH350PS24D
EMH350PS48D
Notes:
1. The EMH250 is available with a top mounted fan cover option. Add suffix ‘-TF’ to model number e.g. EMH250PS12-TF. See mechanical drawing later in this
datasheet. The fan supply V3 is no longer available with this option as it is used to drive the fan.
2. The EMH350 is available with various analog, digital signal and cover options. See availability table and mechanical drawing later in this datasheet. The fan supply
V3 is no longer available with cover options as it is used to drive the fan.
3. The EMH350D models are fitted with an integral ORing diode and are also available with various analog and digital signal options. See availability table and
mechanical drawing later in this datasheet.
Input Characteristics
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage - Operating
80
115/230
275
VAC
Derate output power < 90 VAC. See fig. 1
Input Frequency
47
50/60
63
Hz
>0.9
Power Factor
EN61000-3-2 class A compliant
Input Current - No Load
0.05/0.03
A
115/230 VAC
Input Current - Full Load
2.6/1.3
3.7/1.8
A
115/230 VAC - EMH250
115/230 VAC - EMH350
A
230 VAC cold start, 25 °C
W
EMH250
EMH350
EMH350 with output inhibit (via signal option)
µA
115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.)
Inrush Current
40
5.8
6.4
1.0
No Load Input Power
Earth Leakage Current
Input Protection
90/160
F10 A/250 V internal fuse in both lines
250
Derating Curve - All EMH250 & EMH350 models
Figure 1
100
Output Power (%)
90
80
70
60
50
40
80
85
275
90
Input Voltage (VAC)
2
xppower.com
Output Characteristics
Characteristic
Minimum
Output Voltage - V1
Typical
Units
48
VDC
±1 V1, ±5 V2
%
50% load, 115/230 VAC, V2 EMH350 only
±10 V1
%
Via potentiometer & PMBus control
0
A
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
Notes & Conditions
Maximum
12
See Models and Ratings table
Start Up Delay
1
s
Hold Up Time
16
ms
230 VAC full load (see fig. 2, 3 & 4.)
115 VAC full load (see fig. 5.)
After 20 min warm up
Drift
±0.2
%
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±1 V1, ±5 V2
%
0-100% load, V2 EMH350 only
4
%
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
1
% pk-pk
Transient Response - V1
Over/Undershoot - V1
2
Ripple & Noise
%
20 MHz bandwidth (see fig. 6 & 7.)
Overvoltage Protection
115
140
%
Overload Protection
110
150
% I nom
0.05
%/˚C
°C
Fitted, auto recovery
100
µA
264 VAC/60 Hz
Short Circuit Protection
Vnom DC.
Auto reset, knee point adjustable via PMBus control
(see fig.8) EMH350-50 only
Fitted
Temperature Coefficient
Overtemperature Protection
Patient Leakage Current
Start up delay from AC turn on
Figure 2
V1 Start up example
(115 VAC, 686 ms)
V1
AC
Figure 3
V3 Fan supply example
(115 VAC, 530 ms)
V3
AC
3
xppower.com
Output Characteristics
Figure 4
V2 Standby Supply example
(115 VAC, 75 ms)
EMH350 only
V2
AC
Hold up time from loss of AC
Figure 5
V1 Hold up time example
(115 VAC, 22 ms)
V1
AC
Output Ripple & Noise
Figure 6
EMH350PS12, 350 W, (87 mV
pk-pk ripple, 20 MHz bandwidth)
V1
4
xppower.com
Output Characteristics
Figure 7
EMH350PS24 350 W (85 mV
pk-pk ripple, 20 MHz bandwidth)
V1
Overload Characteristics
Figure 8
Typical Overload Characteristics
(EMH350PS12 shown)
Current limit adjustable via PMBus control, EMH350-50 only
14.00
12.00
Voltage (V)
10.00
8.00
6.00
4.00
2.00
0.00
1
2
3
4
5
34
35
36
37
38
39
40
Current (A)
5
xppower.com
General Specifications
Characteristic
Minimum
Typical
Maximum
Isolation: Input to Output
Input to Ground
Output to Ground
%
4000
VAC
1500
VAC
1500
VAC
Switching Frequency
62-560 / 71 / 50-130
16.3
Weight
Full load (see fig. 9 & 10)
PFC / Main Converter /
Standby Converter
kHz
Power Density
Mean Time Between Failure
Notes & Conditions
Units
87
Efficiency
W/in3
400
kHrs
0.9 (410)
1.0 (450)
lbs (g)
MIL-HDBK-217F, Notice 2
+25 °C GB
EMH250 & EMH350,
EMH350D
Efficiency Versus Load
100%
Figure 9
EMH350PS12
90%
80%
115 V
Efficiency
70%
230 V
60%
50%
40%
30%
20%
10%
0%
0
10
20
30
40
50
60
70
80
90
100
100%
Figure 10
EMH350PS48
90%
80%
115 V
Efficiency
70%
230 V
60%
50%
40%
30%
20%
10%
0%
0
6
10
20
30
40
50
60
70
80
90
100
xppower.com
Xxxxxxxxxx
Environmental
Characteristic
Minimum
Maximum
Units
0
+70
°C
Storage Temperature
-40
+85
°C
Cooling
12
Humidity
Operating Altitude
5
Operating Temperature
Typical
CFM
95
3000
%RH
m
Notes & Conditions
Derate linearly from +50 °C at 2.5%/°C to
50% at 70 °C. (See Thermal Considerations)
Forced-cooled, see Thermal Considerations
& Mechanical details
Non-condensing
Shock
3 x 30 g/11 ms shocks in both +ve & -ve
directions along the 3 orthogonal axis,
total 18 shocks.
Vibration
Three axis 5-500 Hz at 2 g x 10 sweeps
Electromagnetic Compatibility - Emissions
Phenomenon
Conducted
Radiated
Voltage Fluctuations
Standard
EN55011/22
EN55011/22
EN61000-3-3
Test Level
Class B
Class A
Criteria
Notes & Conditions
See EMC report
Electromagnetic Compatibility - Immunity
Phenomenon
Low Voltage PSU EMC
Harmonic Current
Radiated
EFT
Surges
Conducted
Standard
EN61204-3
EN61000-3-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-11
Dips and Interruptions
EN60601-1-2
(EN61000-4-11)
Test Level
High severity level
Class A
3
3
Installation class 3
3
Dip:
30% 10 ms
Dip:
60% 100 ms
Dip: 100% 5000 ms
Dip:
30% 500 ms
Dip:
Criteria
as below
Notes & Conditions
A
A
A
A
A
B
B
A
60% 100 ms
A
Dip:
100% 10 ms
Int.: >95% 5000 ms
A
B
Requires load derating to approx 50% with
100 VAC input.
Safety Agency Approvals
Safety Agency
Safety Standard
Category
CB Report
UL Cert #US/TBA/UL, IEC60950-1:2005 Ed 2
Information Technology
UL
UL File # E139109-AXX-UL, UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2
Information Technology
TUV
TUV Certificate # TBA, EN60950-1:2006
Information Technology
CE
LVD
Safety Agency
Safety Standard
Category
CB Report
Certificate #US/18274/UL, IEC60601-1 Ed 3 Including Risk Management
Medical
UL
UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08
Medical
TUV
TUV EN60601-1:2006
Medical
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Means of Protection
Category
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
Equipment Protection Class
Safety Standard
Notes & Conditions
IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3
See safety agency conditions of
acceptability for details
Class I & BF
IEC60601-1 Ed 3
7
xppower.com
Signals
Signal Functions Available
Model
Remote
OK/Power
Fan Supply 5 V Standby AC
Fail
Sense
EMH250PSXX
EMH350PSXX
EMH350PSXX-01
EMH350PSXX-02
EMH350PSXX-50
EMH350PSXXD
EMH350PSXXD-01
EMH350PSXXD-50
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Characteristic
P
P
P
P
P
P
P
Inhibit V1 &
V Fan
Optional Cover Availability
Speed
Current Share Variable
Fan Control
P
P
P
P
P
P
P
P
P
Standard Top
Fan (-TF)
PMBus
Variable Speed
Top Fan (-VF)
P
P
P
P
P
P
P
P
Notes & Conditions
Signals & Control
Remote Sense
Compensates for 0.5 V total voltage drop
12 V Fan Supply (V3)
12 V/0.6 A supply, present when AC supplied, inhibit turns fan supply off.
5V Standby (V2)
5 V/2 A supply, always present when AC supplied
AC OK/Power Fail
AC OK is an open collector transistor, referenced to negative output, providing a minimum of 3 ms warning of loss of output
regulation. The transistor is normally on when AC is healthy. See fig. 11.
Inhibit
The inhibit high pin should be pulled below 0.4 V to switch V1 & V Fan (V3) off. Open circuit or 2-8 V maximum to switch the
output on. See fig.12.
Current Share
Connecting pin 9 (-01 & -02 models) of like voltage units (3 maximum) will force the current to share between the outputs.
Units share current within 10% of each other at full load. See fig. 13.
Variable Speed Fan Control
When used in conjuction with -VF fan cover, varies the speed of the internal fan depending on temperature of the unit.
See fig. 15.
I2C/PMBus
The I2C PMBus compatible interface can be used for monitoring the unit output voltage, current, internal temperature,
external 3 wire TACHO fan and run time. Adjustment of the output voltage and current limit set point and identification of the
unit model number and serial number are also possible. Consult sales for further information and application notes.
AC OK Power Fail
Inhibit
Parallel & Current Share
(EMH350 recommended connection)
POWER SUPPLY
5 V Standby
Pin 3 or 4
-
1K
+
Current
Share
Se
ns
e
Inhibit Lo
Pin 8 (-sense)
V1 Output
+
+ Sense
+
-
se
en
-S
Transistor On (<0.8 V):
AC OK
Transistor Off (>4.5 V):
AC NOT OK/Power Fail
5V Standby return
pin 1 or 2
J2 Logic Connector
Signals Connector
-
+
Load
8
EMH350PSXX (3)
EMH350PSXX (2)
V1 Output
Inhibit Hi
Pin 10
AC OK Collector
Pin 11
AC OK Emitter
-VE output
EMH350PSXX (1)
V1 Output
-
Current
Share
-S
se
en
+
POWER SUPPLY
Max 30 V 10 mA
Figure 13
Se
ns
e
Figure 12
- Sense
Figure 11
+
xppower.com
Signals
Redundancy N+1
EMH350PSXXD (1)
(EMH350 recommended connection)
EMH350PSXXD (3)
EMH350PSXXD (2)
V1 Output
V1 Output
-
+
-
+
-
+
V1 Output
-
+
Figure 14
Load
Fan Speed Graph
100
90
Fan Speed (%)
Figure 15
80
70
60
50
40
30
20
10
0
20
10
0
Mechanical Details
30
H/Sink Temp °C
40
50
60
EMH250
5.0 (127.0)
0.22
(5.7)
Signals Connector*
4.55 (115.6)
Output Connector
Center Line
Output Adjust
Recommended
Airflow
Direction
2.55
(64.8)
C5
Input Terminal
Block Center Line
-V1 Con 3
0.65
(16.7)
(pin 1) L
E
+V1 Con 2
T1
L
N
E
N
0.73
(18.6)
C3
3.0
(76.2)
0.90
(23.0)
M3 mounting holes in 4 positions
Input Terminal
Block CON 1
D5
0.22 (5.7)
Output Terminals
M4 Pan HD screws
in 2 positions
Torque to 8 lbs-in
(90 cNm) max
Output Connector
Center Line
0.35
(9.1)
1.43
(36.3)
*Signals Connector
TOP VIEW
Input Connector CON 1
TYCO part # 640445-5
Pin 1
Line
Pin 3
Neutral
Pin 5
Earth
Output Connector
Con 2
+V1
Con 3
-V1
1. Dimensions shown in inches (mm).
Tolerance: ±0.02 (±0.5)
N/C
Fan -VE
N/C (pin 1)
N/C
Fan +VE
-VE Sense
+ VE Sense
(pin 10) N/C
N/C (pin 9)
Signals Connector 10 way 2 mm pitch p/n JST BI0B-PHDSS
Mating Half - p/n JST PHDR-10VS,
Contact- 26-22 AWG p/n JST SPHD-001T-P0.5
Pin 2 & 4 removed
Notes
(pin 2) N/C
Mates with Tyco SL-156 Series Connector
2. Weight: 0.90 lb (410 g).
9
xppower.com
Xxxxxxxxxx Details
Mechanical
EMH350
5.0 (127.0)
Signals Connector*
Output Connector
Center Line
Recommended
Airflow
Direction
Output Adjust
C5
(pin 1) L
N
0.73
(18.6)
E
3.0
(76.2)
-V1 Con 3
Output Terminals
M4 Pan HD screws
in 2 positions
Torque to 8 lbs-in
(90 cNm) max
0.65
(16.7)
+V1 Con 2
T1
L
N
E
0.90
(23.0)
0.22 (5.7)
M3 mounting holes in 4 positions
Input Terminal Block
CON 1
C3
2.55
(64.8)
Input Terminal
Block Center Line
0.22
(5.7)
Output Connector
Center Line
D5
(pin 2) +VE Standby
-VE Standby
Fan -VE
-VE Sense
1.43
(36.3)
(pin 10) N/C
Output Connector
0.35
(9.1)
4.55 (115.6)
+VE Standby (pin 1)
CON 2
+V1
CON 3
-V1
-VE Standby
Fan +VE
Input Connector CON 1
TYCO part # 640445-5
+ VE Sense
N/C (pin 9)
*Signals Connector Top View
Signals Connector 10 way 2 mm
pitch p/n JST BI0B-PHDSS
Mating Half - p/n JST PHDR-10VS,
Contact- 26-22 AWG p/n
JST SPHD-001T-P0.5
1
Line
3
Neutral
5
Earth
Pins 2 & 4 removed
Mates with Tyco SL-156
Series Connector
EMH350 (Signal Options)
5
5.0 (127.0)
Signals Connector*
Pin 1
Output Connector
Center Line
Voltage Adjust
Recommended
Airflow
Direction
2.55
(64.8)
Input Terminal
Block Center Line
3.0
(76.2)
-V1 Con 3
0.65
(16.7)
(pin 1) L
+V1 Con 2
N
0.73
(18.6)
E
0.22 (5.7)
0.90
(23.0)
Output Connector Center Line
M3 mounting holes in 4 positions
Input Terminal Block
CON 1
0.22
(5.7)
0.35 (9.1)
4.55 (115.6)
1.43
(36.3)
Pin 11
Pin 12
Pin 9
Pin 10
Pin 7
Pin 8
Pin 5
Pin 6
Pin 3
Pin 4
Pin 1
Pin 2
Signals Connector 12 way 2 mm
pitch p/n JST S12B-PHDSS
Mating Half - p/n JST PHDR-12VS,
Contact- 26-22 AWG p/n
JST SPHD-001T-P0.5
Notes
1. Dimensions shown in inches (mm). Tolerance: ±0.02 (±0.5)
10
Output Terminals
M4 Pan HD screws
in 2 positions
Torque to 8 lbs-in
(90 cNm) max
2. Weight: 0.9 lb (410 g).
EMH350PSXX-01 & EMH350PSXX-02
1
-VE Standby
2
-VE Standby
3
+VE Standby
4
+VE Standby
5 +VE Fan Supply 6 -VE Fan Supply
7
+VE Sense
8
-VE Sense
9 Current Share 10
Inhibit
11
Power Fail
12
N/C
EMH350PSXX-50
1
-VE Standby
2
-VE Standby
3
+VE Standby
4
+VE Standby
5 +VE Fan Supply 6 -VE Fan Supply
7
+VE Sense
8
-VE Sense
9 Fan Tacho Input 10
I2C GND
2
11
I C Data
12
I2C Clock
xppower.com
Xxxxxxxxxx Details
Mechanical
EMH350D
5.75 ±0.02 (146.0 ±0.5)
Signals Connector*
Output Connector
Center Lines
Output Adj.
C5
Recommended
Airflow
2.55
Direction
(64.8)
3.00 ±0.02
(76.2 ±0.5)
(pin 1) L
T1
N
0.73
(18.6)
-V1 Con 3
Output Terminals
M4 Screw in 2 positions
Torque to 8 lbs-in
(90 cNm) max.
0.72
(18.3)
+V1 Con 2
0.91
(23.1)
E
Input Terminal Block,
Center Line
M3 mounting holes in 4 positions
Input Terminal Block
CON 1
D5
4.55 (115.6)
Output Connector
Center Lines
0.22 (5.7)
0.35 (9.1)
0.97
(24.7)
(pin 2) +VE Standby
+VE Standby (pin 1)
-VE Standby
Fan -VE
1.43 ±0.02
(36.3 ±0.5)
Output Connector
-VE Standby
-VE Sense
(pin 10) N/C
Fan +VE
CON 2
+V1
+ VE Sense
CON 3
-V1
N/C (pin 9)
Input Connector CON 1
TYCO part # 640445-5
*Signals Connector Top View
Signals Connector 10 way 2 mm
pitch part number JST B10B-PHDSS,
Mating half part number JST PHDR-10VS,
Contact 26-22 AWG part number
JST SPHD-001T-P0.5
1
Line
3
Neutral
5
Earth
Pins 2 & 4 removed
Mates with Tyco SL-156
Series Connector
EMH350D (Signal Options)
5.75 ±0.02 (146.0 ±0.5)
*Signal Connector
Pin 1
Recommended
Airflow
Direction
Output Connector
Center Lines
Recommended
Airflow
2.55
Direction
(64.8)
3.00 ±0.02
(76.2 ±0.5)
-V1 Con 3
0.72
(18.3)
(pin 1) L
+V1 Con 2
N
0.73
(18.6)
Input Terminal Block,
Center Line
Output Adj.
0.91
(23.1)
E
M3 mounting holes in 4 positions
0.22 (5.7)
Output Connector
Center Lines
Input Terminal Block
4.55 (115.6)
Output Terminals
M4 Screw in 2 positions
Torque to 8 lbs-in
(90 cNm) max.
0.35 (9.1)
0.97
(24.7)
1.43 ±0.02 (36.3 ±0.5)
Pin 11
Pin 12
Pin 9
Pin 10
Pin 7
Pin 8
Pin 5
Pin 6
Pin 3
Pin 4
Pin 1
Pin 2
Signals Connector 12 way 2 mm
pitch p/n JST S12B-PHDSS
Mating Half - p/n JST PHDR-12VS,
Contact- 26-22 AWG p/n
JST SPHD-001T-P0.5
EMH350PSXXD-01
1
-VE Standby
2
-VE Standby
3
+VE Standby
4
+VE Standby
5 +VE Fan Supply 6 -VE Fan Supply
7
+VE Sense
8
-VE Sense
9
Current Share 10
Inhibit
11
Power Fail
12
N/C
EMH350PSXXD-50
1
-VE Standby
2
-VE Standby
3
+VE Standby
4
+VE Standby
5 +VE Fan Supply 6 -VE Fan Supply
7
+VE Sense
8
-VE Sense
9 Fan Tacho Input 10
I2C GND
11
I2C Data
12
I2C Clock
Notes
1. Dimensions shown in inches (mm). Tolerance: ±0.02 (±0.5)
2. Weight: 1.0 lbs (450 g).
11
xppower.com
Xxxxxxxxxx Details
Mechanical
Top Fan - EMH250-TF & EMH350-TF
M3 mounting holes in 4 positions
Max. penetration by screw to be 0.157 (4.0)
from outside face of chassis
5.00 ±0.02 (127.0 ±0.5)
Signals Connector*
Input Terminal
Block, Center Line
3.56 ±0.02
(90.4 ±0.5)
1.01
(25.6)
Input Terminal Block
CON 1
-V1 Con 3
1.84
(46.8)
(pin 1) L
N
E
+V1 Con 2
1.19
(30.1)
0.79
(19.9)
M3 mounting holes in 2 positions
Max. penetration by screw to be 0.157 (4.0) from outside face of chassis
1.96
(50.0)
Output Terminals
M4 Screw in 2
positions
Torque to
8 lbs-in
(90 cNm) max.
0.76
(20.2)
0.75
(19.1)
2.78 ±0.02
(70.5 ±0.5)
(pin 2) +VE
-VE
Fan -VE
0.97
(24.8)
0.75
(19.1)
3.50 (88.9)
+VE (pin 1)
-VE
Fan +VE
-VE Sense
+VE Sense
(pin 9) N/C
N/C (pin 10)
3.50 (88.9)
Signals Connector
Signals Connector 10 way 2 mm pitch
part number JST B10B-PHDSS
Mating half part number JST PHDR-10VS
Contact 26-22 AWG part number JST SPHD-001T-P0.5
Top Fan with Signals Options - EMH350-01TF, EMH350-50TF & EMH350-02VF
5.00 ±0.02 (127.0 ±0.5)
Signals Connector*
Pin 1
3.56 ±0.02
(90.4 ±0.5)
Input Terminal
Block, Center Line
1.01
(25.6)
(pin 1) L
N
E
Input Terminal Block
CON 1
-V1 Con 3
1.84
(46.8)
+V1 Con 2
1.19
(30.1)
M3 mounting holes in 2 positions
Max. penetration by s crew to be 0.157 (4.0) from outside face of chassis
M3 mounting holes in 4
positions. Max. penetration
by screw to be 0.157 (4.0)
from outside face of chassis
Output Terminals
M4 Screw in 2
positions
Torque to
8 lbs-in
(90 cNm) max.
0.76
(20.2)
0.75
(19.1)
0.79
(19.9)
1.96
(50.0)
3.50 (88.9)
EMH350PSXX-01TF &
EMH350PSXX-02VF
2.78 ±0.02
(70.5 ±0.5)
0.97
(24.8)
0.75
(19.1)
3.50 (88.9)
Pin 11
Pin 12
Pin 9
Pin 10
Pin 7
Pin 8
Pin 5
Pin 6
Pin 3
Pin 4
Pin 1
Pin 2
Signals Connector 12 way 2 mm
pitch p/n JST S12B-PHDSS
Mating Half - p/n JST PHDR-12VS,
Contact- 26-22 AWG p/n
JST SPHD-001T-P0.5
Notes
1. Dimensions shown in inches (mm). Tolerance: ±0.02 (±0.5)
12
2. Weight: 1.67 lbs (760 g).
1
-VE Standby
3
+VE Standby
5 +VE Fan Supply
7
+VE Sense
9 Current Share
11
Power Fail
2
-VE Standby
4
+VE Standby
6 -VE Fan Supply
8
-VE Sense
10
Inhibit
12
N/C
EMH350PSXX-50TF
1
-VE Standby
2
-VE Standby
3
+VE Standby
4
+VE Standby
5 +VE Fan Supply 6 -VE Fan Supply
7
+VE Sense
8
-VE Sense
9 Fan Tacho Input 10
I2C GND
2
11
I C Data
12
I2C Clock
xppower.com
Xxxxxxxxxx
Thermal
Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be
exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). See
mechanical drawings for component locations.
The service life of the power supply is largely determined by the temperature of the electrolytic capacitors during normal operation and therefore to
achieve the optimum lifetime, it is recommended to reduce the temperatures shown by approximately 30 °C.
Temperature Measurements (Ambient ≤ 50 °C)
Component
Max Temperature ºC
D5 case
110 °C
C5
105 °C
C3
105 °C
T1 coil
120 °C
Service Life (U Channel Versions)
The estimated service life of the EMH Dual Series is determined by the cooling arrangements and load conditions experienced in the end application.
Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor within the
product when installed in the end application.
The graph below expresses the estimated lifetime for a given component temperature and assumes continuous operation at this temperature.
Estimated Service Life vs Component Temperature
120000
Lifetime (Hrs)
100000
80000
60000
40000
20000
0
105
95
85
75
65
55
C5 C6
Temperature
(°C)
Temperature
(°C)
8 Sept 16
EMH Dual Output Series
•
350 W Forced-Cooled Dual Output
•
Industry Standard 4”x 6”x 1.43”Format
•
IT & Medical (BF) Approvals
•
80 V - 275 VAC Operation
•
Analog & PMBus Signals Options (EMH350)
•
5 V Standby
•
Outputs upto 120 VDC
•
3 Year Warranty
The EMH350 Dual Output series provides two high current outputs in a industry standard 6" x 4" footprint. Available
both in U channel and integrally cooled end fan versions the EMH dual series can be fitted into 1U and configured to
provide single outputs upto 120 VDC.
All models feature two isolated outputs, plus and additional 12V/0.6A fan supply and 5V/2A standby supply
complimented with a range of optional analogue, digital and PMBus signals and controls.
With safety approvals that cover both IEC60950 (IT) and IEC60601 BF (Medical) the EMH350 dual series is suitable for a
wide range of industrial and medical applications including patient contact.
xppower.com
and
Ratings
Models &
Ratings
Output Voltage V1
Output Current V1
Output Voltage V2
Output Current V2
Standby Supply
Fan Supply V3
Maximum
Output Power
Model Number(1)
12 V
16.5 A
24 V
8.3 A
5.0 V/2.0 A
12 V/0.6 A
354 W
EMH350PD21-U
12 V
16.5 A
36 V
5.5 A
5.0 V/2.0 A
12 V/0.6 A
354 W
EMH350PD22-U
12 V
16.5 A
48 V
4.2 A
5.0 V/2.0 A
12 V/0.6 A
355 W
EMH350PD23-U
24 V
8.3 A
48 V
4.2 A
5.0 V/2.0 A
12 V/0.6 A
354 W
EMH350PD24-U
60 V
3.3 A
60 V
3.3 A
5.0 V/2.0 A
12 V/0.6 A
354 W
EMH350PD25-U
Notes:
1. For integral end fan version, replace ‘-U’ in model number with ‘- EF’
2. Output voltages to 120 VDC possible with series output connection contact sales.
Input Characteristics
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage - Operating
80
115/230
275
VAC
Derate output power < 90 VAC. See fig. 1
Input Frequency
47
50/60
63
Hz
>0.9
Power Factor
Input Current - No Load
Input Current - Full Load
Inrush Current
No Load Input Power
Earth Leakage Current
Input Protection
EN61000-3-2 class A compliant
0.05/0.03
3.6/1.8
40
1.0
90/160
F10 A/250 V internal fuse in both lines
250
A
A
A
W
µA
115/230 VAC
115/230 VAC - EMH350
230 VAC cold start, 25 °C
With output inhibit (via signal option)
115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.)
Input Voltage - Derating Curve
Figure 1
100
Output Power (%)
90
80
70
60
50
40
80
85
275
90
Input Voltage (VAC)
2
xppower.com
Output Characteristics
Characteristic
Minimum
Output Voltage - V1
Typical
12
Initial Set Accuracy
Output Voltage Adjustment
Maximum
Units
Notes & Conditions
120
VDC
See Models and Ratings table
±1 V1, ±5 V2
%
50% load, 115/230 VAC
±10 V1
%
Via potentiometer & PMBus control, V2 will track
0
A
Minimum Load
Start Up Delay
1
s
Hold Up Time
16
ms
230 VAC full load (see fig. 2, 3 & 4.)
115 VAC full load (see fig. 5.)
After 20 min warm up
Drift
±0.2
%
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±1 V1, ±5 V2
%
0-100% load, V2 EMH350 only
Cross Regulation
See regulation curves (see fig. 2-5)
Transient Response - V1
4
%
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
1
% pk-pk
Over/Undershoot - V1
2
%
Ripple & Noise
20 MHz bandwidth (see fig. 6 & 7.)
Overvoltage Protection
115
140
%
Overload Protection
110
150
%W
0.05
%/˚C
°C
Fitted, auto recovery
100
µA
264 VAC/60 Hz
Short Circuit Protection
Vnom DC.
Primary power limit V1 & V2 output power combined.
(see fig. 6)
Continuous
Temperature Coefficient
Overtemperature Protection
Patient Leakage Current
Regulation Curves
Figure 2 - EMH350PD21
26
V2 Load Regulation
V2 4.15A (50%) Load
V2 8.3A (100%) Load
V2 Output Voltage
25.5
25
24.5
V1 8.25A (50%) Load
V1 16.5A (100%) Load
24
23.5
23
22.5
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
2
3
4
5
6
7
8
9
10
16.5
V2 Output Voltage
V2 Cross Regulation
25
24.5
24
23.5
23
22.5
22
21.5
21
20.5
V1 Load (A)
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4 5 6 7 8 8.3
V2 Load (A)
Figure 3 - EMH350PD22
V2 Cross Regulation
35
34
V2 2.75A (50%) Load
33
V2 5.5A (100%) Load
32
31
V1 Load (A)
V2 Output Voltage
36
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
2
3
4
5
6
7
8
9
10
16.5
V2 Output Voltage
37
50
45
40
35
30
25
20
15
10
5
0
V2 Load Regulation
V1 8.25A (50%) Load
V1 16.5A (100%) Load
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
2
3
4
5 5.5
V2 Load (A)
3
xppower.com
Regulation Curves
Figure 4 - EMH350PD23
V2 Load Regulation
56
V2 2.1A (50%) Load
V2 4.2A (100%) Load
54
V2 Output Voltage
50
49
48
47
46
45
44
43
42
41
40
52
50
V1 8.25A (50%) Load
48
V1 16.5A (100%) Load
46
44
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
2
3
4
5
6
7
8
9
10
16.5
V2 Output Voltage
V2 Cross Regulation
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
V1 Load (A)
1
2
3
4
4.2
V2 Load (A)
Figure 5 - EMH350PD24
49.5
49
48.5
48
47.5
47
46.5
46
45.5
45
V2 Load Regulation
58
56
V2 2.1A (50%) Load
V2 4.2A (100%) Load
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
2
3
4
5
6
7
V2 Output Voltage
V2 Output Voltage
V2 Cross Regualtion
54
52
V1 8.3A (100%) Load
48
46
44
8 8.3
V1 4.15A (50%) Load
50
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
1
V2 Load (A)
V1 Load
Overload Characteristics
Figure 6
Typical Overload Characteristics
24
22
V2
20
Voltage (V)
18
16
14
12
V1
10
8
6
4
2
0
4
2
4
6
8
10
Current (A)
12
14
16
18
20
2
3
4
4.2
xppower.com
General
Specifications
Xxxxxxxxxx
Characteristic
Minimum
Typical
Efficiency
Maximum
87
Units
Notes & Conditions
%
Full load (see fig. 7)
4000
Isolation: Input to Output
Input to Ground
Output to Ground
V1 to V2 Output
1500
VAC
1500
80
VDC
Switching Frequency
62-560 / 71 / 50-130
Power Density
16.3
Mean Time Between Failure
Weight
PFC / Main Converter /
Standby Converter
kHz
W/in3
MIL-HDBK-217F, Notice 2
+25 °C GB
400
kHrs
1.6 (730)
2.2 (1003)
lbs (g)
U Models
EF Models
Efficiency Versus Load
Figure 7
EMH350PD21
100%
90%
80%
115 V
Efficiency
70%
230 V
60%
50%
40%
30%
20%
10%
0%
0
10
20
30
40
50
60
70
80
90
100
Load %
Environmental
Characteristic
Maximum
Units
0
+70
°C
Storage Temperature
-40
+85
Cooling
16
Humidity
Operating Altitude
5
Operating Temperature
Minimum
Typical
Derate linearly from +50 °C at 2.5%/°C to
50% at 70 °C. (See Thermal Considerations)
°C
CFM
95
3048
Notes & Conditions
%RH
m
Forced-cooled, see Thermal Considerations
& Mechanical details
Non-condensing
Shock
±3 x 30g shocks in each plane, total 18
shocks. 30g = 11ms (+/-0.5msec), half sine.
Conforms to EN60068-2-27 & EN60068-2-47
Vibration
Single axis 10 - 500 Hz at 2g sweep and
endurance at resonance in all 3 planes.
Conforms to EN60068-2-6
5
xppower.com
Electromagnetic Compatibility - Emissions
Phenomenon
Conducted
Standard
EN55011/22
Test Level
Class B
Radiated
EN55011/22
Class A
Voltage Fluctuations
Criteria
Notes & Conditions
AC input cable fitted with Würth Electronik
ferrrite core (3 turns), Part No.742-700-56.
See EMC report for details.
EN61000-3-3
Electromagnetic Compatibility - Immunity
Phenomenon
Standard
Test Level
Criteria
EN61204-3
High severity level
as below
Harmonic Current
EN61000-3-2
Class A
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
Low Voltage PSU EMC
EN55024
(100 VAC)
EN55024
(240 VAC)
Dips and Interruptions
EN60601-1-2
(100 VAC)
EN60601-1-2
(240 VAC)
3
Dip >95% (0 VAC), 8.3ms
Dip 30% (70 VAC), 416ms
A
B
B
Dip >95% (0 VAC), 4160ms
B
Dip >95% (0 VAC), 10.0ms
B
Dip 30% (168 VAC), 500ms
B
Dip >95% (0 VAC), 5000ms
B
Dip >95% (0 VAC), 10.0ms
A
Dip 60% (40 VAC), 100ms
A
Dip 30% (70 VAC), 500ms
A
Dip >95% (0 VAC), 5000ms
B
Dip >95% (0 VAC), 10.0ms
A
Dip 60% (96 VAC), 100ms
A
Dip 30% (168 VAC), 500ms
A
Dip >95% (0 VAC), 5000ms
B
Notes & Conditions
Derate Output Power to 140 W
Safety Agency Approvals
Safety Agency
Safety Standard
Category
CB Report
UL, IEC60950-1:2005 Ed 2
Information Technology
UL
UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2
Information Technology
TUV
TUV, EN60950-1:2006
Information Technology
CE
LVD & RoHS
Safety Agency
Safety Standard
Category
CB Report
IEC60601-1 Ed 3 Including Risk Management
Medical
UL
ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08
Medical
TUV
EN60601-1:2006
Medical
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Means of Protection
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
Equipment Protection Class
Safety Standard
Notes & Conditions
IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3
See safety agency conditions of
acceptability for details
Class I & BF
6
Category
IEC60601-1 Ed 3
xppower.com
Signals Description & Compatibility
Model
Remote
Sense
P
P
EMH350PDxx-U
EMH350PDxx-EF
Characteristic
Fan Supply
P
P
5 V Standby
P
P
Functions
AC OK/
Inhibit V1 &
Power Fail
V Fan
P
P
Current Share
P
P
P
P
Variable Speed
Fan Control
PMBus
P
Contact
Sales
Notes & Conditions
Signals & Control
Remote Sense
Compensates for 0.5 V total voltage drop
12 V Fan Supply (V3)
12 V/0.6 A supply, present when AC supplied, inhibit turns fan supply off.
5V Standby
5 V/2 A supply, always present when AC supplied
AC OK/Power Fail
AC OK is an open collector transistor, referenced to negative output, providing a minimum of 3 ms warning of loss of output
regulation. The transistor is normally on when AC is healthy. See fig. 8.
Inhibit
The inhibit high pin should be pulled below 0.4 V to switch V1 & V Fan (V3) off. Open circuit or 2-8 V maximum to switch
the output on. See fig. 9.
Current Share
Connecting pin 9 (-01 & -02 models) of like voltage units (3 maximum) will force the current to share between the outputs.
Units share current within 10% of each other at full load. See fig. 10.
Variable Speed Fan Control
Only available for -EF models. Varies the speed of the integral fans depending on input voltage, output power & ambient
temperature within the unit.
Inhibit
Parallel & Current Share
Figure 8
Figure 9
Figure 10
-
+
Current
Share
1K
Inhibit Hi
Pin 10
AC OK Collector
Pin 11
Transistor On (<0.8 V):
AC OK
Transistor Off (>4.5 V):
AC NOT OK/Power Fail
+
+
EMH350PDXX (3)
V1 Output
-
Current
Share
-S
+
se
en
Inhibit Lo
Pin 8 (-sense)
5V Standby return
pin 1 or 2
J2 Logic Connector
Se
ns
e
-
se
en
-S
AC OK Emitter
-VE output
V1 Output
+ Sense
Max 30 V 10 mA
EMH350DSXX (2)
V1 Output
+
5 V Standby
Pin 3 or 4
EMH350PDXX (1)
- Sense
POWER SUPPLY
POWER SUPPLY
Se
ns
e
AC OK Power Fail
Signals Connector
-
+
V2 Output
EMH350PDXX (1)
-
+
-
+
-
+
V2 Output
EMH350DSXX (2)
Load
-
+
V2 Output
EMH350PDXX (3)
xppower.com
Mechanical Details
EMH350PDxx-U
6.00 (152.4)
Output Terminals
M4 PAN HD screws in 4 positions
Torque to 8 lbs-in (90 cNm) max.
Airflow
Direction
Output Connector
16 CFM
C5
-V1
4.00
(101.6)
Input Terminal Block
Center Line
0.71
17.93
T1
L
N
E
+V1
-V2
2.57
(65.4)
1.96
(49.8)
1.30
(33.1)
+V2
0.69
(17.4)
D5
Input Terminal Block
TYCO p/n 640445-5
C3
Output Connector
Center Line
M3 Mounting holes in 2 positions each side
Max penetration by screw:
3.5 mm from outside face of chassis
CON 2
+V1
CON 3
-V1
Input Connector CON 1
TYCO part # 640445-5
1
Line
3
Neutral
5
Earth
Pins 2 & 4 removed
0.63
(16.1)
Mates with Tyco SL-156
Series Connector
1.57
(39.8)
0.75
(19.1)
1.73 (44.0)
4.00 (101.6)
EMH350PDxx-EF
7.00 (177.8)
Output Terminals
M4 PAN HD screws in 4 positions
Torque to 8 lbs-in (90 cNm) max.
Recommended
Airflow
Direction
2.00
(50.8)
-V1
4.00
(101.6)
Input Terminal Block
Center Line
+V1
-V2
2.58
(65.4)
2.00
(50.8)
1.31
(33.1)
0.63
(16.1)
1.96
(49.8)
7.59 (192.8)
Input Terminal Block - Dinkle Products DT-2C-A02W-03
0.69
(17.4)
1.18
(29.9)
1.75
(44.5)
0.88
(22.2)
0.57
(14.4)
Pin 11
Pin 9
Pin 7
Pin 5
Pin 3
Pin 1
Pin 12
Pin 10
Pin 8
Pin 6
Pin 4
Pin 2
Pin
1
2
3
4
5
6
Pin Connections
Function
Pin
Function
-VE Standby
7 V1 +VE Sense
-VE Standby
8
V1 -VE Sense
+VE Standby
9 Current Share
+VE Standby 10
Inhibit
Fan +VE
11
Power Fail
Fan -VE
12 Not Connected
Signals Connector - 12 WAY 2mm PITCH p/n
JST S12B-PHDSS
Mating HALF - p/n JST PHDR-12VS
Contact - 26-22 AWG p/n JST SPHD-001T-P0.5
Notes
1. Dimensions shown in inches (mm).
Tolerance: ±0.02 (±0.5)
8
2. Weight: U channel: 1.6 lb (730 g),
End Fan: 2.2 lbs (1003 g)
+V2
Output Connector
Center Line
xppower.com
Thermal
Considerationse (U Channel Versions)
Xxxxxxxxxx
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be
exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). See
Mechanical Details for component locations.
Temperature Measurements (Ambient ≤ 50 °C)
Component
Max Temperature ºC
D5 case
120 °C
C5
105 °C
C3
105 °C
T1 coil
120 °C
Service Life (U Channel Versions)
The estimated service life of the EMH Dual Series is determined by the cooling arrangements and load conditions experienced in the end application.
Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor within the
product when installed in the end application.
The graph below expresses the estimated lifetime for a given component temperature and assumes continuous operation at this temperature.
Estimated Service Life vs Component Temperature
120000
Lifetime (Hrs)
100000
80000
60000
40000
20000
0
105
95
85
75
65
55
C5 C6
Temperature
(°C)
Temperature
(°C)
08 Sept 16
Similar pages