Rhombus F-129 High frequency data line filter Datasheet

PARAMETER
(1)
Inductance
(1)
Leakage Inductance
(1)
Interwinding Capacitance
Primary DC Resistance
UNITS
85.0 Min.
µH
0.25 Max.
µH
High Frequency
Data Line Filter
12 Max.
pF
3 Coils 6 Data Lines
0.30 Max.
Ω
500 Min.
VRMS
20
MHz
10k Min.
MΩ
250
mW
Isolation (HI-POT)
SRF (Ref.)
Insulation Resistance
Power Rating
Schematic Diagram
Crosstalk 60 dB @ 5 MHz Nominal
50 dB @ 10 MHz Nominal
Longitudinal Conversion Loss
0 - 300KHz
56 dB Min.
300 KHz - 500KHz 52 db Min.
500 KHz - 1MHz
46 dB Min.
1MHz - 5 MHz
36 db Min.
Operating Temperature Range -40OC TO +85OC
Storage Temperature Range -55OC TO +125OC
Turns ratio 1:1 + 0%
Current Rating: 100mA
1
Tested at 100KHz and 500 mV RMS
Operating temperature Range
-45oC to +85oC
Physical Dimensions in inches (mm)
RHOMBUS P/N: F-129
CUST P/N:
DATE: 1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET:
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971
High Frequency
Data Line Filter:
P/N F-129G
Impedance
Impedance
(Ω)
3500
3000
2500
2000
1500
1000
500
1 MHz
Frequency
500 MHz
Crosstalk
Crosstalk ( dB )
- 40
- 50
- 60
- 70
- 80
1 MHz
Frequency
10 MHz
RHOMBUS P/N: F-129
CUST P/N:
DATE: 1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET:
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971
Crosstalk
D.U.T = F-129G
D.U.T. = F-129
Sine Wave 2VRMS
up to 10MHz
RS = 50 Ω
RL = 135 Ω
20 Log V/E
Longitudinal Conversion Loss
D.U.T = F-129G
D.U.T. = F-129
Resistors Matched to within 0.03%
R1 + R2 = 67.5 Ω
R3 + R4 = 67.5 Ω
20 Log EL/ETr
RHOMBUS P/N: F-129
CUST P/N:
DATE: 1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET:
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971
Similar pages