CUSTOMER DRAWING
3mm ±1mm
Product Dimensions
As Received
After Free Recovery
Product
Name
A±2.54
(A±0.100)
25.40
(1.000)
27.90
(1.100)
33.02
(1.300)
D-300-08
D-300-12
D-300-18
øB
min
4.32
(0.170)
6.35
(0.250)
9.14
(0.360)
W
min
0.30
(0.012)
0.38
(0.015)
0.38
(0.015)
øB
max
2.03
(0.080)
3.05
(0.120)
4.57
(0.180)
W
min
0.76
(0.030)
1.02
(0.040)
1.27
(0.050)
Maximum
Weight
Pounds/mpc
1.15
2.55
4.50
MATERIALS
1. MOLDED CAP: Heat-shrinkable, cross-linked modified polyolefin.
2. MELTABLE RING: Modified thermoplastic.
3. DEFORMABLE DAM: Radiation cross-linked, thermally stabilized modified polyolefin.
APPLICATION
1. These parts are designed to meet the requirements as shown in the Requirements Section when tested as listed.
2. Parts to be assembled as outlined herein.
3. “B” recovered is the maximum inside diameter of the heat-shrinkable cap.
4. “W” is the wall thickness of the molded cap only, and is measured along the vertical wall.
5. “A” is the average length of the cap and is equal to (A min + A max)/2.
1.0
SCOPE
This document covers the requirements and test procedures applicable to heat shrinkable, stub-splice
encapsulation cap (caps) and the molded component thereof.
2.0
APPLICABLE DOCUMENTS
The specifications and standards referenced herein shall form part of this specification to the extent
specified.
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
M. FORONDA
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
1 of 7
CUSTOMER DRAWING
3.0
REQUIREMENTS
3.1
3.1.3
Material: The splice encapsulation caps shall be fabricated from the materials specified on sheet 1 of this
specification. The materials shall be homogenous and essentially free from flaws, defects, pinholes, seams,
cracks and inclusions.
Color: The caps shall be black.
Properties of Molded Component: The molded component and the material from which it is fabricated
shall meet the requirements in Table 1.
Properties of Finished Caps: The finished caps shall meet the requirements of Table 2.
4.0
QUALITY ASSURANCE PROVISIONS
3.1.1
3.1.2
4.1
4.1.1
4.1.2
Classification of Tests:
Qualification of Tests: Qualification testing shall consist of all test listed in this specification.
Acceptance tests: Acceptance tests shall consist of those tests applicable to Test Groups A and F of
Table 2.
4.2
Sampling Instructions:
4.2.1
Qualification Test Samples: Qualification testing shall consist of six molded slabs, 6 x 6 x 0.075± .010
inches and 62 D-300-12 caps. The molded slabs shall be fabricated from the same lot of material and shall
be subjected to the same degree of cross-linking as the molded components.
4.2.2
Acceptance Test Samples: Acceptance test samples shall consist of finished caps selected at random in
accordance with ANSI/ASQC Z1.4, Inspection Level S-2, AQL 6.5%. A lot of finished caps shall consist
of all caps fabricated from the same lot of molded components, from the same production run, and offered
for inspection at the same time.
4.3
Test Procedures – Molded Slabs
4.3.1
Tensile Strength And Ultimate Elongation: Three specimens cut from a molded slab, using die D of
ASTM D 412, shall be tested for tensile strength and ultimate elongation in accordance with ASTM D 412.
4.3.2
Low-Temperature Flexibility: A 6- x ¼ inch specimen cut from a molded slab shall be mounted in a loop
position between movable, parallel, sets of jaws 2 ½ inches apart, mounted on a test fixture. Each end of
the specimen shall extend at least ¾ inch into a set of jaws and shall be firmly fastened. The specimen and
the test fixture shall be conditioned for four hours at –55 ± 2°C (-67 ± 4°F). While at this temperature, the
sets of jaws shall be moved rapidly from a 2 ½ inch to a 1 inch separation.
4.3.3
Heat Shock: Three 6 x ¼ inch specimens, cut from a molded slab, shall be conditioned for four hours in a
225 ± 5°C (437 ± 9°F) mechanical-convection oven in which air passes the specimens at a velocity of
100 to 200 feet per minute. After conditioning, the specimens shall be removed from the oven, cooled to
room temperature, and visually examined for evidence of dripping, flowing, or cracking.
4.3.4
Heat Aging:
4.3.4.1 Procedure A: Three specimens, prepared and measured in accordance with 4.3.1, shall be conditioned for
168 hours in a 175 ± 5°C (347 ±9°F) mechanical-convection oven in which air passes the specimens at a
velocity of 100 to 200 feet per minute. After conditioning, the specimens shall be removed from the oven,
cooled to room temperature, and tested for tensile strength and ultimate elongation in accordance with
4.3.1.
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
M. FORONDA
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
2 of 7
CUSTOMER DRAWING
4.3.4.2. Procedure B: Three specimens, prepared and measured in accordance with 4.3.1, shall be conditioned for
1000 hours in a 150 ± 3°C (302 ± 5°F) mechanical-convection oven in which air passes the specimens at a
velocity of 100 to 200 feet per minute. After conditioning, the specimens shall be removed from the oven,
cooled to room temperature, and tested for tensile strength and ultimate elongation in accordance with
4.3.1.
4.2.1
Solvent Resistance: Three specimens, prepared and measured in accordance with 4.3.1, shall be
completely immersed in each of the solvents listed in the applicable section of Table 1 for 24 hours at 25 ±
3°C (77 ± 5°F). The volume of the fluid shall be not less than 20 times that of the specimens. After
conditioning, the specimens shall be lightly wiped, and then air-dried for 30 to 60 minutes at room
temperature. The specimens shall then be tested for tensile strength and ultimate elongation in accordance
with 4.3.1.
4.3
Test Procedures – Finished Caps
4.3.1
Test Assembles: Part D-300-12 shall be used to qualify D-300-08, D-300-12 and D-300-18. Fifty-five
specimens shall be made by connecting two wires, MIL- 16878/4-14; with a suitable crimp connector.
Wires shall be 10 ± 1 inches in length. The caps shall be applied in accordance with Thermofit Assembly
Procedure D-300-08/-12/-18.
4.3.2
Dimensions and Dimensional Recovery: Five specimens, as supplied, shall be measured for dimensions in
accordance with ASTM D 876. The specimens shall then be conditioned for ten minutes in a 200 ± 5°C
(392 ± 9°F) oven, quenched in water in less than 35°C (95°F) for at least 30 seconds, wiped dry, and the
appropriate measurements taken.
4.3.3
Insulation Resistance: The specimens shall be immersed to within 3 inches of the lead ends in a water bath
containing 5% by weight of NaCl for a minimum of 30 minutes after which time the insulation resistance
shall be measured between the salt solution and the test leads. The test potential shall be 500 volts D.C.
The readings shall be taken after an electrification time of one minute.
4.3.4
Dielectric Withstanding Voltage: The specimen shall be immersed to within 3 inches of the lead ends in a
water bath containing 5% by weight of NaCl for a minimum of 30 minutes after which time the potential
between the salt water and the test leads shall be raised from 0 to the specified voltage at a rate of 500 volts
per second. This potential shall be maintained for one minute and the voltage reduced to 0.
4.3.5
Temperature Cycling: Fifteen assemblies shall be subjected to 200 cycles. Each cycle shall consist of 20
minutes at 135°C (275°F) and 5 minutes at 240°C (400°F) in mechanical-convection ovens with an air
velocity of 100 to 200 feet per minute past the specimens. The specimens shall be subjected to 20 cycles
per day and shall be maintained at 25 ± 5°C (77 ± 9°F) between test days. After the last cycle, the
specimen shall be cooled to 25 ± 5°C (77 ± 9°F) within one hour and tested for insulation resistance (4.4.3)
and dielectric withstanding voltage (4.4.4).
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
M. FORONDA
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
3 of 7
CUSTOMER DRAWING
4.2.1
Heat Aging: Fifteen assemblies shall be conditioned for 1000 hours at 150 ± 3°C (302 ± 5°F) in a
mechanical-convection oven with an air velocity of 100 to 200 feet per minute past the specimens. After
conditioning, the specimen shall be cooled to 25 ± 5°C (77 ± 9°F) within one hour and tested for insulation
resistance (4.4.3) and dielectric withstanding voltage (4.4.4).
4.2.1
Altitude Immersion: Fifteen assemblies shall be immersed in a water bath containing 5% by weight of
NaCl and placed in a chamber. Wire ends, opposite the cap, shall be within the chamber, but not
submerged. The exposed wire ends shall not be sealed. The chamber pressure shall be reduced to
approximately 1 inch of mercury and maintained for 30 minutes. The chamber pressure shall then be
returned to atmospheric pressure. The insulation assistance shall be measured in accordance with 4.4.3.
This shall constitute one cycle. Two additional environment cycles shall be run. At the end of the third
cycle, the insulation resistance (4.4.3) shall be re-measured, and the dielectric withstanding voltage test
(4.4.4) shall be performed.
4.2.1
Corrosive effect: Two caps, as supplied, shall be placed in the bottoms of two clean ½ x 12 inches test
tubes (one cap per tube). A third tube shall be used for control. A copper-glass mirror, about 1 x ¼ inches
shall be suspended from 6 to 7 inches above the bottom of each tube by a fine copper wire attached to a
cork wrapped in aluminum foil. The corks shall tightly seal the test tubes. The lower 2 inches of each tube
then shall be placed in an oven or oil bath at 175 ± 3°C for 16 hours. After cooling, the mirrors shall be
examined in a good light against a white background. Evidence of corrosion shall be areas of transparency
larger than pinholes in a mirror. Discoloration of the copper film or reduction of its thickness shall not be
considered corrosion. The mirrors shall be vacuum- deposited copper with thickness equal to 10 ± 5%
transmission of normal incident light of 5000 angstroms. They shall be stored in a vacuum and shall be
used for test only if no oxide film is present and the copper is not visibly damaged.
4.2.1
Flammability: Ten assemblies shall be mounted vertically, closed end down, in a draft-free chamber. An 8
x 8 inch piece of tissue paper conforminf to UU-T-450 shall be suspended taut and centered 9 ½ inches
below the test specimen, a minimum of ½ inch from the table top, in such a manner that any dripping
particles will fall on the tissue paper. A standard 1/8” Bunsen burner shall be adjusted to produce a blue
flame approximately 1” high. The tip of the flame shall be applied to the closed end of the test specimen
for 10 seconds. The flame shall then be removed and the specimen shall remain undisturbed until burning
ceases. Failure of more than one specimen to extinguish itself within the time specified or ignition of the
tissue paper caused by dripping of flaming or glowing particles shall be cause for rejection.
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
M. FORONDA
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
4 of 7
CUSTOMER DRAWING
TABLE 1
REQUIREMENTS FOR MOLDED COMPONENT
Property
Unit
Tensile Strength
Ultimate Elongation
Stiffness
psi
percent
psi
Specific Gravity
Hardness
Low Temperature Flexibility
4 hours @ -55°C (-67°F)
Heat Shock
4 hours @ 225°C (437°F)
Heat Aging
Shore D
1500 minimum
250 minimum
10,000 minimum
25,000 maximum
1.40 maximum
50±10
No cracking
Section 4.3.1
(ASTM D 412)
ASTM D 747
No Dripping, flowing or
cracking
Section 4.3.3
psi
percent
percent
Section 4.3.1
(ASTM D 412)
ASTM D 635
ASTM D 876
ASTM D 570
Procedure A
Section 4.3.5
psi
percent
1200 minimum
200 minimum
Section 4.3.1
(ASTM D 412)
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
M. FORONDA
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
ASTM D 792
ASTM D 2240
Section 4.3.2
1200 minimum
200 minimum
Non-burning
Rating of 1 or less
0.2 maximum
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
Method of Test
Section 4.3.4
Procedures A and B
Followed by test for:
Tensile Strength
Ultimate Elongation
Flammability
Fungus Resistance
Water Absorption
24 hours @ 25° C (77°F)
Solvent Resistance
24 hours @ 25°C (77°F) in
JP-4 Fuel
Skydrol* 500
Hydraulic Fluid (MIL-H-5606)
Aviation Gasoline (100/130)
Water
Followed by test for:
Tensile Strength
Ultimate Elongation
Requirement
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
5 of 7
CUSTOMER DRAWING
TABLE 2
REQUIREMENTS FOR FINISHED CAP
Test Group A – Five Caps
Unit
Requirement
Property
Dimensions
Dimension Recovery
Inches
Sheet 1
Inches
Sheet 1
Test Group B – Fifteen Specimens
Property
Unit
Insulation Resistance
Temperature Cycling
Megaohms
Followed by test for:
Insulation Resistance
Dielectric Withstanding Voltage
Property
ASTM D 876
Section 4.4.2
Requirement
5000 minimum
Followed by test for:
Insulation Resistance
Dielectric Withstanding Voltage
Method of Test
Section 4.4.3
Section 4.4.5
Megaohms
5000 minimum
Volts
1500 (rms)
Test Group C – Fifteen Specimens
Unit
Requirement
Insulation Resistance
Heat Aging
Method of Test
Section 4.4.3
Section 4.4.4
Method of Test
Megaohms
5000 minimum
Section 4.4.3
Megaohms
Volts
5000 minimum
1500 (rms)
Section 4.4.3
Section 4.4.4
Test Group D – Fifteen Specimens
Property
Unit
Insulation Resistance
Altitude Immersion
Megaohms
Followed by test for:
Insulation Resistance
Dielectric Withstanding Voltage
Corrosive Effect
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
Method of Test
Section 4.4.3
Section 4.4.7
Non-Corrosive
Test Group F – Ten Assemblies
Self extinguishing
within 10 seconds. No
ignition of tissue paper.
Flammability
M. FORONDA
5000 minimum
Megaohms
5000 minimum
Volts
1500 (rms)
Test Group E– Two Caps
Unit
Requirement
Property
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
Requirement
Section 4.4.3
Section 4.4.4
Method of Test
Section 4.4.8
Section 4.4.9
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
6 of 7
CUSTOMER DRAWING
Thermofit Assembly Procedure
1.
2.
3.
4.
5.
Strip the wires and install crimp type connector or solder wires together. Connector should be installed so that
1/6 ± 1/32 of conductor is exposed between the connector and the wire insulation, as shown in Figure 1.
Choose the proper size cap from the chart below. Place splice into cap so that the connector bottoms on the
rounded end of the cap.
Heat the assembly, using a Thermogun, Model 500A, or equivalent, equipped with a TG-12 or TG-13A
reflector.
The average length of time required for proper heating is given in the chart. However, since the heat sink effect
of various wire bundles may vary considerably, several trial specimens should be crossed-sectioned as shown in
Figure 2 before proceeding with production installations. If the area between the wires is not completely filled,
a longer heating cycle should be established.
With wire bundles of more than three wires, it is helpful to slightly deform the cap by pinching in the area
above the connection at the end of the heating cycle and then returning the cap to the heat for an additional
period to allow the cap to return to its cylindrical shape.
Chart 1
Part
Name
D-300-08
D-300-12
D-300-18
Splicer Diameter
Minimum
Maximum
2.03 (0.080)
3.04 (0.120)
3.04 (0.120)
5.08 (0.200)
4.57 (0.180)
7.62 (0.300)
Figure 1
Figure 2
Tyco Electronics
305 Constitution Dr
Menlo Park, CA
94025, U.S.A.
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
M. FORONDA
ANGLES: N/A
ROUGHNESS
IN MICRON
CAGE CODE:
06090
Time
(sec.)
30
45
60
Raychem
Devices
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
ECO NUMBER:
REPLACES:
D010044
TITLE:
CAP, SPLICE ENCAPSULATION
DOCUMENT NO.:
D-300-08/-12/-18
REV:
DATE:
B
SCALE:
08-018889
© 2008 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
31-July-08
SIZE:
NTS
A
SHEET:
7 of 7