Data Delay DDU222F-10 5-tap, ttl-interfaced fixed delay line (series ddu222f) Datasheet

DDU222F
data 3 
delay
devices, inc.
5-TAP, TTL-INTERFACED
FIXED DELAY LINE
(SERIES DDU222F)
FEATURES
•
•
•
•
•
PACKAGES
Five equally spaced outputs
Very narrow device (SIP package)
Stackable for PC board economy
Input & outputs fully TTL interfaced & buffered
10 T2L fan-out capability
1 2 3 4 5 6 7 8
VCC IN T1 T2 T3 T4 T5 GND
DDU222F-xx Commercial
DDU222F-xxM Military
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The DDU222F-series device is a 5-tap digitally buffered delay line. The
IN
Signal Input
signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an
T1-T5 Tap Outputs
amount given by the device dash number. For dash numbers less than
VCC +5 Volts
25, the total delay of the line is measured from T1 to T5, with the nominal
GND Ground
value given by the dash number. The nominal tap-to-tap delay increment
is given by 1/4 of this number. The inherent delay from IN to T1 is nominally 3.5ns. For dash numbers
greater than or equal to 25, the total delay of the line is measured from IN to T5, with the nominal value
given by the dash number. The nominal tap-to-tap delay increment is given by 1/5 of this number.
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
•
•
•
•
Part
Number
DDU222F-4
DDU222F-6
DDU222F-8
DDU222F-10
DDU222F-12
DDU222F-16
DDU222F-25
DDU222F-30
DDU222F-35
DDU222F-40
DDU222F-45
DDU222F-50
DDU222F-60
DDU222F-75
DDU222F-100
DDU222F-125
DDU222F-150
DDU222F-175
DDU222F-200
DDU222F-250
•
•
Minimum input pulse width: 40% of total delay
Output rise time: 2ns typical
Supply voltage: 5VDC ± 5%
Supply current: ICCL = 32ma typical
ICCH = 7ma typical
Operating temperature: 0° to 70° C
Temp. coefficient of total delay: 100 PPM/°C
3.5ns
VCC IN
25%
T1
25%
T2
25%
T3
25%
T4
T5 GND
Functional diagram for dash numbers < 25
20%
VCC IN
20%
T1
20%
T2
20%
T3
20%
T4
T5 GND
Functional diagram for dash numbers >= 25
Total
Delay (ns)
4 ± 1.0 *
6 ± 1.0 *
8 ± 2.0 *
10 ± 2.0 *
12 ± 2.0 *
16 ± 2.0 *
25 ± 3.0
30 ± 3.0
35 ± 3.0
40 ± 3.0
45 ± 3.0
50 ± 3.0
60 ± 3.0
75 ± 4.0
100 ± 5.0
125 ± 6.5
150 ± 7.5
175 ± 8.0
200 ± 10.0
250 ± 12.5
Delay Per
Tap (ns)
1.0 ± 0.5
1.5 ± 0.5
2.0 ± 1.0
2.5 ± 1.0
3.0 ± 1.0
4.0 ± 1.5
5.0 ± 2.0
6.0 ± 2.0
7.0 ± 2.0
8.0 ± 2.0
9.0 ± 3.0
10.0 ± 3.0
12.0 ± 3.0
15.0 ± 3.0
20.0 ± 3.0
25.0 ± 3.0
30.0 ± 3.0
35.0 ± 4.0
40.0 ± 4.0
50.0 ± 5.0
* Total delay is referenced to first tap output
Input to first tap = 3.5ns ± 1ns
NOTE: Any dash number between 4 and 250 not
shown is also available.
1997 Data Delay Devices
Doc #97011
1/27/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
DDU222F
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The DDU222F tolerances are guaranteed for
input pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 40% of the total delay and periods as
small as 80% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The DDU222F relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VCC to GND,
located as close as possible to the VCC pin, is
recommended. A wide VCC trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VCC
VIN
TSTRG
TLEAD
MIN
-0.3
-0.3
-55
MAX
7.0
VDD+0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER
High Level Output Voltage
SYMBOL
VOH
Low Level Output Voltage
VOL
High Level Output Current
Low Level Output Current
High Level Input Voltage
Low Level Input Voltage
Input Clamp Voltage
Input Current at Maximum
Input Voltage
High Level Input Current
Low Level Input Current
Short-circuit Output Current
Output High Fan-out
Output Low Fan-out
IOH
IOL
VIH
VIL
VIK
IIHH
Doc #97011
1/27/97
IIH
IIL
IOS
MIN
2.5
TYP
3.4
MAX
UNITS
V
0.35
0.5
V
-1.0
20.0
0.8
-1.2
0.1
mA
mA
V
V
V
mA
20
-0.6
-150
25
12.5
µA
mA
mA
Unit
Load
2.0
-60
NOTES
VCC = MIN, IOH = MAX
VIH = MIN, VIL = MAX
VCC = MIN, IOL = MAX
VIH = MIN, VIL = MAX
VCC = MIN, II = IIK
VCC = MAX, VI = 7.0V
VCC = MAX, VI = 2.7V
VCC = MAX, VI = 0.5V
VCC = MAX
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
DDU222F
PACKAGE DIMENSIONS
1
2
3
4
5
6
7
8
.200
MAX.
.900 MAX.
.020
TYP.
.100
TYP.
.020 TYP.
.700 TYP.
.300
MAX.
.100
MIN.
.010
TYP.
DDU222F-xx (Commercial)
1
2
3
4
5
6
7
8
.200
MAX.
.900 MAX.
.005 .375
MIN. MAX.
.150
±.030
.018 TYP.
.700 TYP.
.100
TYP.
.010
TYP.
DDU222F-xxM (Military)
Doc #97011
1/27/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
DDU222F
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
Ambient Temperature: 25oC ± 3oC
Supply Voltage (Vcc): 5.0V ± 0.1V
Input Pulse:
High = 3.0V ± 0.1V
Low = 0.0V ± 0.1V
Source Impedance:
50Ω Max.
Rise/Fall Time:
3.0 ns Max. (measured
between 0.6V and 2.4V )
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
1 FAST-TTL Gate
5pf ± 10%
1.5V (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
PRINTER
COMPUTER
SYSTEM
REF
PULSE
GENERATOR
OUT
IN
TRIG
DEVICE UNDER
TEST (DUT)
T1
IN
T2
TRIG
TIME INTERVAL
COUNTER
T3
T4
T5
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
2.4V
1.5V
0.6V
2.4V
1.5V
0.6V
TRISE
OUTPUT
SIGNAL
VIL
TFALL
VOH
1.5V
1.5V
VOL
Timing Diagram For Testing
Doc #97011
1/27/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com