Click on Series name for product info on aimtec.com Series AM1LE-NZ 1 Watt | DC-DC Converter FEATURES: • Efficiency 75% • SMD Package • Low Ripple & Noise Models Single output Model AM1LE-0505SH35-NZ Input Voltage (V) 4.5-5.5 Input Specifications Parameters Voltage range Filter Reflected Ripple Current Absolute Maximum Rating No Load Input Current Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Output Voltage (V) Output Current Max / Min (mA) 5.0 200 / 20 Nominal Parameters Voltage accuracy Short Circuit protection Line voltage regulation Load voltage regulation (Single) Temperature coefficient Ripple & Noise General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature www.aimtec.com F 051e R12.A Isolation (VDC) 3500 Typical 5 Conditions Input Current Max Load | No Load 220 267 Conditions Per 1% of Vin Change 10% to 100% load Nominal Input 20MHz Bandwidth 20 -0.7 to 9 20 mA VDC mA Rated Units VDC 3500 Typical ±2.5 continuous VDC MOhm pF Maximum Units 1.2 % % %/oC mV p-p 12 60 Typical Maximum ±0.03 100% load 100 300 No derating up to +105 C (see derating graph) -50 to +125 -55 to +135 100 Free Air Convection Non Condensing 95 Epoxy Resin (UL94-V0) 1.5 0.50 x 0.44 x 0.28 inches 12.70 x 11.20 x 7.25 mm 3.5M hours 300 (1.5mm from case for 10 seconds) Tel: +1 514 620 2722 1 of 4 75 Units >1000 20 Nominal load (See tolerance graph) Efficiency (%) Maximum Typical 60 sec, <1mA 500VDC Conditions Operating Temperature -50 oC to +125 oC Input / Output Isolation of 3500 VDC Pin Compatible with multiple manufacturers Continuous Short Circuit Protection Max Capacitiv e Load 4.5-5.5 Capacitor 15 5V input models Output Specifications • • • • % Units KHz o C o C o C % RH g o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1LE-NZ 1 Watt | DC-DC Converter Safety Specifications Parameters Agency Approval EN55022 Class B (see recommended circuit) IEC61000-4-2, Perf. Criteria B (ESD Contact +/- 6KV) Standards Pin Out Specifications Pin 1 2 3 4 5 6 7 8 1000VDC Single -V Input +V Input No Pin -V Output +V Output No Pin No Pin N.C EMI Recommended Circuit (Class B) Vin- + C1 (4.7 µf / 50V) Vin+ LDM (6.8 µh) Aimtec DC-DC Converter Vo+ RL (Full Load) Vo- - Input Reflected Ripple Current Test Circuit Vin+ L1 (4.7 µh) Test Point + C1 (220 µf) Vin- - Aimtec DC-DC Converter Vo+ RL (Full Load) Vo- * Tested at full load, and nominal input www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1LE-NZ 1 Watt | DC-DC Converter Dimensions Front View 8.30 (0.33) Side View 7.00 (0.27) 0º~10º angle 1.70 (0.07) 0.25 (0.01) 0.88 (0.04) 1.50 (0.06) Top View 12.70 (0.50) 7.62 (0.30) 11.20 8.30 (0.44) (0.33) 1 0.60 (0.02) 2.54 (0.10) Load Accuracy Tolerance Graph Derating Free Air Convection 10 % 105ºC al loa d line +2.5 % 100 -2.5 % 80 Output Voltage Accuracy% Rated Output Voltage Typic -7.5 % 70 % 10 % 50 % Output Current % (Nominal Input) 100 % Output Power % 5% 125ºC 60 Safe Operating Area 40 20 105C 0 -50 -30 0 40 80 100 125C 120 140 Ambient Temperature º C www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1LE-NZ 1 Watt | DC-DC Converter Efficiency vs. Loading NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only