AIMTEC AM1LE-NZ 1 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM1LE-NZ
1 Watt | DC-DC Converter
FEATURES:
• Efficiency 75%
• SMD Package
• Low Ripple & Noise
Models
Single output
Model
AM1LE-0505SH35-NZ
Input
Voltage
(V)
4.5-5.5
Input Specifications
Parameters
Voltage range
Filter
Reflected Ripple Current
Absolute Maximum Rating
No Load Input Current
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Output
Voltage
(V)
Output
Current Max
/ Min (mA)
5.0
200 / 20
Nominal
Parameters
Voltage accuracy
Short Circuit protection
Line voltage regulation
Load voltage regulation (Single)
Temperature coefficient
Ripple & Noise
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
www.aimtec.com
F 051e R12.A
Isolation
(VDC)
3500
Typical
5
Conditions
Input Current
Max Load | No Load
220
267
Conditions
Per 1% of Vin Change
10% to 100% load
Nominal Input
20MHz Bandwidth
20
-0.7 to 9
20
mA
VDC
mA
Rated
Units
VDC
3500
Typical
±2.5
continuous
VDC
MOhm
pF
Maximum
Units
1.2
%
%
%/oC
mV p-p
12
60
Typical
Maximum
±0.03
100% load
100
300
No derating up to +105 C (see derating graph) -50 to +125
-55 to +135
100
Free Air Convection
Non Condensing
95
Epoxy Resin (UL94-V0)
1.5
0.50 x 0.44 x 0.28 inches 12.70 x 11.20 x 7.25 mm
3.5M hours
300 (1.5mm from case for 10 seconds)
Tel: +1 514 620 2722
1 of 4
75
Units
>1000
20
Nominal load (See tolerance graph)
Efficiency
(%)
Maximum
Typical
60 sec, <1mA
500VDC
Conditions
Operating Temperature -50 oC to +125 oC
Input / Output Isolation of 3500 VDC
Pin Compatible with multiple manufacturers
Continuous Short Circuit Protection
Max
Capacitiv
e Load
4.5-5.5
Capacitor
15
5V input models
Output Specifications
•
•
•
•
%
Units
KHz
o
C
o
C
o
C
% RH
g
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1LE-NZ
1 Watt | DC-DC Converter
Safety Specifications
Parameters
Agency Approval
EN55022 Class B (see recommended circuit)
IEC61000-4-2, Perf. Criteria B (ESD Contact +/- 6KV)
Standards
Pin Out Specifications
Pin
1
2
3
4
5
6
7
8
1000VDC
Single
-V Input
+V Input
No Pin
-V Output
+V Output
No Pin
No Pin
N.C
EMI Recommended Circuit (Class B)
Vin-
+
C1
(4.7 µf / 50V)
Vin+
LDM
(6.8 µh)
Aimtec
DC-DC
Converter
Vo+
RL
(Full
Load)
Vo-
-
Input Reflected Ripple Current Test Circuit
Vin+
L1
(4.7 µh)
Test
Point
+
C1
(220 µf)
Vin-
-
Aimtec
DC-DC
Converter
Vo+
RL
(Full
Load)
Vo-
* Tested at full load, and nominal input
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1LE-NZ
1 Watt | DC-DC Converter
Dimensions
Front View
8.30
(0.33)
Side View
7.00
(0.27)
0º~10º angle
1.70
(0.07)
0.25
(0.01)
0.88
(0.04)
1.50
(0.06)
Top View
12.70
(0.50)
7.62
(0.30)
11.20 8.30
(0.44) (0.33)
1
0.60
(0.02)
2.54
(0.10)
Load Accuracy Tolerance Graph
Derating
Free Air Convection
10 %
105ºC
al loa
d line
+2.5 %
100
-2.5 %
80
Output Voltage
Accuracy%
Rated
Output
Voltage
Typic
-7.5 %
70 %
10
%
50
%
Output Current % (Nominal Input)
100
%
Output Power %
5%
125ºC
60
Safe Operating Area
40
20
105C
0
-50
-30
0
40
80
100
125C
120
140
Ambient Temperature º C
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1LE-NZ
1 Watt | DC-DC Converter
Efficiency vs. Loading
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may
vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of
25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis
on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be
available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other
such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard
Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages