Rectron BR1005 Single-phase silicon bridge rectifier Datasheet

BR1005
RECTRON
THRU
SEMICONDUCTOR
TECHNICAL SPECIFICATION
BR1010
SINGLE-PHASE SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes
FEATURES
* Surge overload rating: 200 amperes peak
* Low forward voltage drop
BR-10
MECHANICAL DATA
*
*
*
*
*
*
UL listed the recognized component directory, file #E94233
Epoxy: Device has UL flammability classification 94V-O
Lead: Mil-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 7.86 grams
Mounting: Hole thru for # 6 screw
.296 (7.5)
.255 (6.5)
.042 (1.1)
DIA.
.039 (1.0)
TYP.
.75
MIN.
(19.1)
.770 (19.6)
.730 (18.5)
HOLE FOR
NO. 6 SCREW
AC
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
AC
.520 (13.2)
.480 (12.2)
.770 (19.6)
.730 (18.5)
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.520 (13.2)
.480 (12.2)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At TA = 25oC unless otherwise noted)
SYMBOL
BR1005
BR101
BR102
BR104
BR106
BR108
BR1010
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
RATINGS
Maximum DC Blocking Voltage
o
Maximum Average Forward Tc = 50 C
Rectified Output Current at: Tc = 100oC
10.0
IO
Amps
6.0
o
T A = 50 C
6.0
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I FSM
200
Typical Thermal Resistance
RθJA
28
0
C/W
Typical Thermal Resistance
R θ JC
6.5
0
C/W
TJ
-55 to + 150
0
C
T STG
-55 to + 150
0
C
Operating Temperature Range
Storage Temperature Range
Amps
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
SYMBOL
VF
Maximum Forward Voltage Drop per element at 5.0A DC
o
Maximum Reverse Current at Rated
@T A = 25 C
DC Blocking Voltage per element
@T C = 100 oC
Note: “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
BR1005
BR101
BR102
BR104
BR106
BR108
BR1010
UNITS
1.1
Volts
5.0
uAmps
0.2
mAmps
IR
2005-3
REV:A
RATING AND CHARACTERISTIC CURVES ( BR1005 THRU BR1010 )
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
250
AVERAGE FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
SURGE CURRENT
8.3ms Single Half Sine-Wave
(JEDEC Method)
200
150
100
50
10
8
CA
SE
6
AM
BI
4
EN
T
60 Hz RESISTIVE OR
INDUCTIVE LOAD
2
0
0
1
2
4 6 8 10 20
40 60 80100
NUMBER OF CYCLES AT 60Hz
0
50
100
CASE TEMPERATURE, (
150
)
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
100
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
CHARACTERISTICS
TJ = 25
Pulse Width = 300us
1% Duty Cycle
10
1.0
.1
10
1.0
TJ = 25
.1
.01
.01
.6
.7
.8
.9
1.0
1.1
1.2
1.3
INSTANTANEOUS FORWARD VOLTAGE, (V)
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, ( % )
RECTRON