VER : A_6 update : 2015.11.16 AC-DC Power Module ATC30 SERIES 30 Watts KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-305VAC High Efficiency up to 89% Isolation Class II <0.3W No Load Input Power Very Small 2.52” x 1.77” x 0.92 “ Package CE, CB and UL Approval 3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated Model No. ( Single Output ) Max Output Wattage (W) Voltage ATC30-3.3S 16.5W (Note1) Frequency (Hz) Input Output Environment Physical ATC30-15S 30W ATC30-24S 30W 90-305 VAC or 120-430 VDC Current (Full load) 600 mA max. (115 VAC) /400 mA max. (230 VAC) Inrush Current (<2ms) 30 A max. (115 VAC) / 60 A max. (230 VAC) Leakage Current 0.25 mA max. No Load Input Power (<240 VAC) <0.3W External Fuse (mandatory) 3.15 A slow blow type Voltage (V.DC.) 3.3V Voltage Accuracy ±2% Current (mA) max 5000 Line Regulation (LL-HL) (typ.) ±0.5% Load Regulation (0-100%) (typ.) ±1.5% Minimum Load 0% 5V 12V 15V 24V 5000 2500 2000 1250 ±1% 6800 uF 6800 uF 1600 uF 1200 uF 470 uF 100mVp-p 100mVp-p 150mVp-p 150mVp-p 240mVp-p Efficiency (at 230 VAC) 80% 84% 89% 86% 86% Hold-up Time 10 ms min. Switching Frequency (typ.) ( at 230 VAC ) 66 kHz Ripple & Noise (max.) Isolation ATC30-12S 30W 47-63 Hz Maximum Capacitive Load Protection ATC30-5S 25W (Note2) Over Power Protection Hiccup technique, auto-recovery Over Voltage Protection Zener diode clamp Short Circuit Protection Hiccup mode, indefinite (automatic recovery) Input-Output (V.AC) 3000V Input-FG (V.AC) 1500V Output-FG (V.AC) 500V Operating Temperature -40°C…+70°C (with derating) Storage Temperature -40°C…+85°C Max Case Operating Temperature Under 115 VAC 78°C , others 85°C Temperature Coefficient ±0.02%/°C Humidity 95% RH MTBF >400,000 h @ 25°C (MIL-HDBK-217F) Dimension (L x W x H) 2.52 x 1.77 x 0.92 Inches Case Material Plastic resin (flammability to UL 94V-0) Weight 130 g Cooling Method Free air convection http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 ( 64.0 x 45.0 x 23.5 mm ) Tolerance 0.5 mm -1- VER : A_6 update : 2015.11.16 AC-DC Power Module ATC30 SERIES 30 Watts ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated Model No. Safety ( Single Output ) Agency Approvals ATC30-3.3S CE, UL/cUL, CB EMI (Conducted & Radiated Emission) EMC ATC30-5S ATC30-12S ATC30-15S ATC30-24S EN 55022 class B EMS (Noise Immunity) EN 55024 ESD EN61000-4-2 air ± 8kV , Contact ± 4kV (A) Radiated Immunity EN61000-4-3 3V/m (A) Fast Transient EN61000-4-4 ± 1kV (A) Surge EN61000-4-5 ±1kV (A) Conducted Immunity EN61000-4-6 3Vrms PFMF EN61000-4-8 1A/m (A) Dips EN61000-4-11 30% 500ms (A) (A) NOTE 1. Please check the derating carve for more details. 2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 3. It's necessary to add Varistor 14S561K at L / N input side in parallel. 4. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw MECHANICAL DIMENSION ( Top View ) BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 DERATING PIN# Single 1 AC IN (N) 2 AC IN (L) 3 -DC OUT 4 NO PIN 5 +DC OUT -2- VER : A_6 update : 2015.11.16 AC-DC Power Module ATC30 SERIES 30 Watts EFFICIENCY VERSUS LOAD ATC30-12S VIN Input Voltage (V) Efficiency (%) VS Efficiency 90 115 180 230 264 305 87.6 88.4 90.2 90.4 90.2 89.9 95.00% 92.50% 90.00% EFF% 87.50% 85.00% 82.50% 80.00% 77.50% 75.00% 90 115 180 230 264 305 VIN LOAD VS Efficiency Load (%) 10 20 30 40 50 60 70 80 90 100 230V (%) 84.6 87.9 89.3 90.2 90.3 89.9 89.9 90.1 90.1 90.4 91.00% 90.00% 89.00% 88.00% EFF% 87.00% 86.00% 85.00% 84.00% 83.00% 82.00% 81.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3-