TI1 ADS1115 Ultra-small, low-power, spi-compatible, 16-bit analog-to-digital converter and temperature sensor with internal reference Datasheet

ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
Ultra-Small, Low-Power, SPI™-Compatible, 16-Bit
Analog-to-Digital Converter and Temperature Sensor with Internal Reference
Check for Samples: ADS1118
FEATURES
DESCRIPTION
•
The ADS1118 is a precision analog-to-digital
converter (ADC) with 16 bits of resolution offered in
an ultra-small, leadless QFN-10 package or an
MSOP-10 package. The ADS1118 is designed with
precision, power, and ease of implementation in
mind. The ADS1118 features an onboard reference
and oscillator. Data are transferred via a serial
peripheral interface (SPI). The ADS1118 operates
from a single power supply ranging from 2V to 5.5V.
1
23
•
•
•
•
•
•
•
•
•
Ultra-Small QFN Package:
2mm × 1,5mm × 0,4mm
Wide Supply Range: 2.0V to 5.5V
Low Current Consumption:
– Continuous Mode: Only 150μA
– Single-Shot Mode: Auto Shutdown
Programmable Data Rate:
8SPS to 860SPS
Single-Cycle Settling
Internal Low-Drift Voltage Reference
Internal Temperature Sensor:
– 0.5°C Max Error
Internal Oscillator
Internal PGA
Four Single-Ended or Two Differential Inputs
APPLICATIONS
•
•
•
Temperature Measurement:
– Thermocouple Measurement
– Cold Junction Compensation
– Thermistor Measurement
Portable Instrumentation
Factory Automation and Process Controls
The ADS1118 can perform conversions at rates up to
860 samples per second (SPS). An onboard
programmable gain amplifier (PGA) is available on
the ADS1118 that offers input ranges from the supply
to as low as ±256mV. This range allows both large
and small signals to be measured with high
resolution. The ADS1118 also features an input
multiplexer (MUX) that provides two differential or
four single-ended inputs. The ADS1118 can also
function as a high-accuracy temperature sensor. This
temperature sensor can be used for system-level
temperature monitoring or cold junction compensation
for thermocouples.
The ADS1118 operates either in continuous
conversion mode or a single-shot mode that
automatically powers down after a conversion.
Single-shot mode significantly reduces current
consumption during idle periods. The ADS1118 is
specified from –40°C to +125°C.
2V
0.1 F
2V
1Mȍ
GND
500ȍ
0.1 F
GND
AIN0
VDD
1 F
1Mȍ
500ȍ
ADS1118
Voltage
Reference
AIN1
0.1 F
SCLK
GND
GND
2V
1Mȍ
MUX
PGA
SPI
Interface
GND
500ȍ
0.1 F
DIN
Oscillator
AIN3
500ȍ
GND
0.1 F
CS
DOUT/DRDY
AIN2
1 F
1Mȍ
16-bit Ȉǻ
ADC
High Accuracy
Temp Sensor
GND
GND
GND
1
2
3
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
SPI is a trademark of Motorola.
All other trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
For the most current package and ordering information, see the Package Option Addendum at the end of this
document, or visit the device product folder on www.ti.com.
ABSOLUTE MAXIMUM RATINGS (1)
ADS1118
VDD to GND
Analog input current
Analog input current
V
100, momentary
mA
10, continuous
mA
–0.3 to VDD + 0.3
V
–0.3 to +5.5
V
Human body model (HBM)
JEDEC standard 22, test method A114-C.01, all pins
±4000
V
Charged device model (CDM)
JEDEC standard 22, test method C101, all pins
±1000
V
–40 to +125
°C
+150
°C
–60 to +150
°C
Analog input voltage to GND
DIN, DOUT/DRDY, SCLK, CS voltage to GND
ESD ratings
Operating temperature range
Maximum junction temperature
Storage temperature range
(1)
UNIT
–0.3 to +5.5
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to absolute
maximum conditions for extended periods may affect device reliability.
PRODUCT FAMILY
2
DEVICE
RESOLUTION
(Bits)
MAXIMUM SAMPLE
RATE (SPS)
SPECIAL
FEATURES
PGA
INTERFACE
INPUT CHANNELS
(Differential/
Single-Ended)
ADS1118
16
860
Temperature sensor
Yes
SPI
2/4
ADS1018
12
3300
Temperature sensor
Yes
SPI
2/4
ADS1115
16
860
Comparator
Yes
I2C
2/4
ADS1114
16
860
Comparator
Yes
I2C
1/1
2
ADS1113
16
860
None
No
I C
1/1
ADS1015
12
3300
Comparator
Yes
I2C
2/4
ADS1014
12
3300
Comparator
Yes
I2C
1/1
ADS1013
12
3300
None
No
I2C
1/1
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
ELECTRICAL CHARACTERISTICS
Maximum/minimum specifications at –40°C to +125°C, VDD = 3.3V, data rate = 8SPS, and full-scale (FS) = ±2.048V, unless
otherwise noted. Typical values are at +25°C, VDD = 3.3V, data rate = 8SPS, and full-scale (FS) = ±2.048V, unless otherwise
noted.
ADS1118
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
ANALOG INPUT
Full-scale input voltage (1)
VIN = (AINP) – (AINN)
Analog input voltage
AINP or AINN to GND
±4.096/PGA
GND
Differential input impedance
V
VDD
V
See Table 1
Common-mode input impedance
FS = ±6.144V (1)
8
MΩ
FS = ±4.096V (1), ±2.048V
6
MΩ
FS = ±1.024V
3
MΩ
FS = ±0.512V, ±0.256V
100
MΩ
8, 16, 32, 64, 128, 250, 475, 860
SPS
SYSTEM PERFORMANCE
Resolution
No missing codes
16
Data rate (DR)
Data rate variation
–10
All data rates
Output noise
Integral nonlinearity
Offset error
Gain error
DR = 8SPS, FS = ±2.048V, best fit (2)
%
1
LSB
±2
LSB
FS = ±2.048V, differential inputs
±0.1
FS = ±2.048V, single-ended inputs
±0.25
LSB
FS = ±2.048V
0.002
LSB/°C
FS = ±2.048V, with dc supply variation
0.2
LSB/V
FS = ±2.048V at +25°C
0.01
FS = ±0.256V
7
FS = ±2.048V
5
(3)
Gain drift (3) (4)
FS = ±6.144V
(1)
0.15
%
ppm/°C
40
5
Gain power-supply rejection
PGA gain match (3)
10
See Typical Characteristics
Offset drift
Offset power-supply rejection
Bits
ppm/°C
ppm/°C
10
ppm/V
Match between any two PGA gains
0.01
0.1
Gain match
Match between any two inputs
0.01
0.1
Offset match
Match between any two inputs
0.6
LSB
At dc and FS = ±0.256V
105
dB
At dc and FS = ±2.048V
100
dB
Common-mode rejection
At dc and FS = ±6.144V
(1)
%
%
90
dB
fCM = 60Hz, DR = 860SPS
105
dB
fCM = 50Hz, DR = 860SPS
105
dB
TEMPERATURE SENSOR
–40
Temperature sensor range
Temperature sensor resolution
Temperature sensor accuracy
(1)
(2)
(3)
(4)
+125
°C
°C/LSB
0.03125
0°C to +70°C
0.2
±0.5
–40°C to +125°C
0.4
±1
°C
°C
vs supply
0.03125
±0.25
°C/V
This parameter expresses the full-scale range of the ADC scaling. In no event should more than the smaller of VDD + 0.3V or 5.5V be
applied to this device.
Best fit INL covers 99% of full-scale.
Includes all errors from onboard PGA and reference.
Not production tested; ensured by characterization.
Copyright © 2010–2011, Texas Instruments Incorporated
3
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
Maximum/minimum specifications at –40°C to +125°C, VDD = 3.3V, data rate = 8SPS, and full-scale (FS) = ±2.048V, unless
otherwise noted. Typical values are at +25°C, VDD = 3.3V, data rate = 8SPS, and full-scale (FS) = ±2.048V, unless otherwise
noted.
ADS1118
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
DIGITAL INPUT/OUTPUT
Logic level
VIH
0.7VDD
VDD
V
VIL
GND
0.2VDD
V
VOH
IOH = 1mA
0.8VDD
VOL
IOL = 1mA
GND
V
0.2VDD
V
Input leakage
IH
VIH = 5.5V
±10
μA
IL
VIL = GND
±10
μA
5.5
V
2
μA
5
μA
200
μA
POWER-SUPPLY REQUIREMENTS
Power-supply voltage
2
Power-down current at +25°C
0.5
Power-down current up to +125°C
Supply current
Operating current at +25°C
150
Operating current up to +125°C
Power dissipation
300
μA
VDD = 5.0V
0.9
mW
VDD = 3.3V
0.5
mW
VDD = 2.0V
0.3
mW
TEMPERATURE
Storage temperature
–60
+150
°C
Specified temperature
–40
+125
°C
THERMAL INFORMATION
ADS1118
THERMAL METRIC (1)
DGS
UNITS
10 PINS
θJA
Junction-to-ambient thermal resistance
θJCtop
Junction-to-case (top) thermal resistance
51.5
θJB
Junction-to-board thermal resistance
108.4
ψJT
Junction-to-top characterization parameter
ψJB
Junction-to-board characterization parameter
106.5
θJCbot
Junction-to-case (bottom) thermal resistance
n/a
(1)
4
186.8
2.7
°C/W
For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
PIN CONFIGURATIONS
RUG PACKAGE
QFN-10
(TOP VIEW)
DGS PACKAGE
MSOP-10
(TOP VIEW)
DIN
10
SCLK
1
9
DOUT/DRDY
CS
2
8
VDD
GND
3
7
AIN3
AIN0
4
6
AIN2
SCLK
1
10 DIN
CS
2
9
DOUT/DRDY
GND
3
8
VDD
AIN0
4
7
AIN3
AIN1
5
6
AIN2
5
AIN1
PIN DESCRIPTIONS
PIN #
PIN NAME
ANALOG/
DIGITAL
INPUT/
OUTPUT
1
SCLK
Digital input
Serial clock input
2
CS
Digital input
Chip select; active low
3
GND
Analog
4
AIN0
Analog input
Differential channel 1: positive input or single-ended channel 1 input
5
AIN1
Analog input
Differential channel 1: negative input or single-ended channel 2 input
6
AIN2
Analog input
Differential channel 2: positive input or single-ended channel 3 input
7
AIN3
Analog input
Differential channel 2: negative input or single-ended channel 4 input
8
VDD
Analog
9
DOUT/DRDY
Digital output
Serial data out combined with data ready; active low
10
DIN
Digital input
Serial data input
Copyright © 2010–2011, Texas Instruments Incorporated
DESCRIPTION
Ground
Power supply: 2V to 5.5V
5
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
SPI TIMING CHARACTERISTICS
tCSH
CS
tSCLK
tCSSC
tSPWH
tSCCS
SCLK
tDIHD
tDIST
tSPWL
tSCSC
DIN
tCSDOD
tDOHD
tDOPD
tCSDOZ
Hi-Z
Hi-Z
DOUT
Figure 1. Serial Interface Timing
TIMING REQUIREMENTS: SERIAL INTERFACE TIMING
At TA = –40°C to +125°C and VDD = 2V to 5.5V, unless otherwise noted.
SYMBOL
(1)
(2)
(3)
6
DESCRIPTION
MIN
MAX
UNIT
tCSSC
CS low to first SCLK: setup time (1)
100
ns
tSCLK
SCLK period
250
ns
tSPWH
SCLK pulse width: high
100
ns
tSPWL
SCLK pulse width: low (2)
tDIST
Valid DIN to SCLK falling edge: setup time
50
50
tDIHD
Valid DIN to SCLK falling edge: hold time
tDOPD
SCLK rising edge to valid new DOUT: propagation delay (3)
tDOHD
SCLK rising edge to DOUT invalid: hold time
tCSDOD
tCSDOZ
100
ns
28
ms
ns
ns
50
ns
0
ns
CS low to DOUT driven: propagation delay
100
ns
CS high to DOUT Hi-Z: propagation delay
100
ns
tCSH
CS high pulse
200
ns
tSCCS
Final SCLK falling edge to CS high
100
ns
CS can be tied low.
Holding SCLK low longer than 28ms resets the SPI interface.
DOUT load = 20pF || 100kΩ to DGND.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
TYPICAL CHARACTERISTICS
At TA = +25°C and VDD = 3.3V, unless otherwise noted.
TOTAL ERROR vs INPUT SIGNAL
DATA RATE vs TEMPERATURE
4
4
VDD = 2V
VDD = 3.3V
VDD = 5V
3
2
2
Data Rate Error (%)
Total Error (mV)
Includes noise, offset, and gain error.
3
1
0
-1
-2
FS = ±2.048V
Data Rate = 860SPS
Differential Inputs
-3
-4
-2.048
0
-1.024
1
0
−1
−2
−3
1.024
−4
−60 −40 −20
2.048
0
Input Signal (V)
20
40
60
80
Temperature (°C)
Figure 2.
100 120 140
G028
Figure 3.
NOISE vs INPUT SIGNAL
NOISE vs SUPPLY VOLTAGE
10
35
FS = ±0.512V
FS = ±2.048V
DR = 860SPS
DR = 860SPS
30
RMS Noise (µV)
RMS Noise (µV)
8
6
4
DR = 128SPS
25
20
15
DR = 128SPS
10
DR = 8SPS
DR = 8SPS
2
5
0
−0.5 −0.4 −0.3 −0.2 −0.1 0
0.1 0.2
Input Voltage (V)
0.3
0.4
0
2.0
0.5
3.5
4.0
4.5
Supply Voltage (V)
Figure 5.
NOISE vs TEMPERATURE
INL vs SUPPLY VOLTAGE (1)
5.0
5.5
G018
15
Integral Nonlinearity (ppm)
FS = ±2.048V
Data Rate = 8SPS
8
RMS Noise (µV)
3.0
Figure 4.
10
9
2.5
G017
7
6
5
4
3
12.5
FS = ±0.256V
FS = ±0.512V
FS = ±2.048V
FS = ±6.144V
10
7.5
5
2.5
2
1
−40
−20
0
20
40
60
Temperature (°C)
Figure 6.
(1)
80
100
120
G019
0
2.0
2.5
3.0
3.5
4.0
4.5
Supply Voltage (V)
5.0
5.5
G010
Figure 7.
This parameter expresses the full-scale range of the ADC scaling. In no event should more than VDD + 0.3V be applied to this device.
Copyright © 2010–2011, Texas Instruments Incorporated
7
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C and VDD = 3.3V, unless otherwise noted.
INL vs INPUT SIGNAL
INL vs INPUT SIGNAL
5
10
FS = ±2.048V
VDD = 3.3V
DR = 8SPS
Best Fit
3
2
1
0
−1
−2
−40°C
+25°C
+125°C
−3
−4
−5
−2
−1.5
−40°C
+25°C
+125°C
8
Integral Nonlinearity (ppm)
Integral Nonlinearity (ppm)
4
6
4
2
0
−2
−4
FS = ±0.512V
VDD = 3.3V
DR = 8SPS
Best Fit
−6
−8
−1
−0.5
0
0.5
Input Signal (V)
1
1.5
−10
−0.5
2
−0.4
−0.2
G011
Figure 8.
INL vs INPUT SIGNAL
3
2
Integral Nonlinearity (ppm)
Integral Nonlinearity (ppm)
G012
1
0
−1
−2
−40°C
+25°C
+125°C
−3
−2
−1.5
−40°C
+25°C
+125°C
8
6
4
2
0
−2
−4
FS = ±0.512V
VDD = 5V
DR = 8SPS
Best Fit
−6
−8
−1
−0.5
0
0.5
Input Signal (V)
1
1.5
−10
−0.5
2
−0.4
−0.2
G013
Figure 10.
−0.1
0
0.1
Input Signal (V)
0.2
0.4
0.5
G014
Figure 11.
INL vs TEMPERATURE
INL vs DATA RATE
12
16
FS = ±2.048V
DR = 8SPS
Best Fit
VDD = 2V
VDD = 3.3V
VDD = 5V
8
6
4
2
0
−60 −40 −20
FS = ±2.048V
Best Fit
14
Integral Nonlinearity (ppm)
Integral Nonlinearity (ppm)
0.5
INL vs INPUT SIGNAL
FS = ±2.048V
VDD = 5V
DR = 8SPS
Best Fit
−4
−40°C
+25°C
+125°C
12
10
8
6
4
2
0
20
40
60
80
Temperature (°C)
Figure 12.
8
0.4
10
4
10
0.2
Figure 9.
5
−5
−0.1
0
0.1
Input Signal (V)
100 120 140
G015
0
8
16
32
64
128
250
Data Rate (SPS)
475
860
G016
Figure 13.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C and VDD = 3.3V, unless otherwise noted.
SINGLE-ENDED OFFSET vs TEMPERATURE
SINGLE-ENDED OFFSET vs SUPPLY
60
60
AIN0 to GND
AIN1 to GND
AIN2 to GND
AIN3 to GND
AIN0 to GND
AIN1 to GND
AIN2 to GND
AIN3 to GND
40
Offset Voltage (µV)
Offset Voltage (µV)
40
20
0
−20
−40
20
0
−20
−40
FS = ±2.048V
−60
−40
−20
FS = ±2.048V
0
20
40
60
Temperature (°C)
80
100
−60
120
2
2.5
3
3.5
4
Supply Voltage (V)
G004
Figure 14.
DIFFERENTIAL OFFSET vs TEMPERATURE
G005
DIFFERENTIAL OFFSET vs SUPPLY
40
AIN0 to AIN1
AIN0 to AIN3
AIN1 to AIN3
AIN2 to AIN3
20
AIN0 to AIN1
AIN0 to AIN3
AIN1 to AIN3
AIN2 to AIN3
30
Offset Voltage (µV)
30
Offset Voltage (µV)
5
Figure 15.
40
10
0
−10
−20
−30
20
10
0
−10
−20
−30
FS = ±2.048V
−40
−40
−20
FS = ±2.048V
0
20
40
60
Temperature (°C)
80
100
−40
120
G006
Figure 16.
2
2.5
3
3.5
4
Supply Voltage (V)
4.5
5
G007
Figure 17.
OFFSET DRIFT HISTOGRAM
OFFSET HISTOGRAM
15
200
Offset Drift from −40°C to +125°C
FS = ±2.048V, MUX = AIN0 to AIN3
30 units from one production lot
540 units from 3 production lots
FS = ±2.048V
Number of Occurrences
Number of Occurrences
4.5
10
5
100
50
Offset Drift (LSB/°C)
Figure 18.
Copyright © 2010–2011, Texas Instruments Incorporated
−10
−8
−6
−4
−2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
0.005
0.004
0.003
0.002
0.001
0
−0.001
−0.002
−0.003
−0.004
0
−0.005
0
150
Offset (µV)
G046
G000
Figure 19.
9
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C and VDD = 3.3V, unless otherwise noted.
GAIN ERROR vs TEMPERATURE
GAIN ERROR vs SUPPLY
0.05
0.15
0.04
0.10
0.03
Gain Error (%)
Gain Error (%)
0.02
0.01
0
FS = ±0.256V
FS = ±0.512V
FS = ±1.024V
FS = ±2.048V
FS = ±4.096V
FS = ±6.144V
−0.01
−0.02
−0.03
−0.04
−0.05
−40
−20
0
20
40
60
80
Temperature (°C)
100
120
0.05
FS = ±2.048V
-0.05
-0.10
140
-0.15
2.0
2.5
3.0
G008
3.5
4.0
4.5
5.0
5.5
Supply Voltage (V)
Figure 20.
Figure 21.
GAIN ERROR HISTOGRAM
TEMPERATURE SENSOR ERROR
vs
AMBIENT TEMPERATURE
1
200
540 units from 3 production lots
FS = ±2.048V
Average Temperature Error
Average ± 3 sigma
Average ± 6 sigma
0.8
Temperature Error (°C)
Number of Occurrences
FS = ±256mV
0
150
100
50
0.6
0.4
0.2
0
−0.2
−0.4
−0.6
−0.8
−1
−40
0.05
0.04
0.045
0.03
0.035
0.02
0.025
0.01
0.015
0
0.005
−0.01
−0.005
−0.015
−0.02
0
Gain Error (%)
−20
0
20
40
60
Temperature (°C)
TEMPERATURE SENSOR ERROR HISTOGRAM
G023
TEMPERATURE SENSOR ERROR HISTOGRAM
40
15
Temperature Error (°C)
Figure 24.
G040
Temperature Error (°C)
0.5
0.4
−0.5
0.5
0.4
0.3
0.2
0.1
0
−0.1
0
−0.2
0
−0.3
5
−0.4
5
0.3
10
0.2
10
20
0.1
15
25
0
20
30
−0.1
25
−0.2
30
Ambient temperature = 0°C
48 units from 3 production lots
−0.3
Number of Occurrences
35
−0.4
Ambient temperature = −40°C
48 units from 3 production lots
−0.5
Number of Occurrences
120
Figure 23.
40
10
100
G000
Figure 22.
35
80
G040
Figure 25.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C and VDD = 3.3V, unless otherwise noted.
TEMPERATURE SENSOR ERROR HISTOGRAM
TEMPERATURE SENSOR ERROR HISTOGRAM
40
15
Temperature Error (°C)
G043
Figure 27.
TEMPERATURE SENSOR ERROR HISTOGRAM
OPERATING CURRENT vs TEMPERATURE
40
300
Ambient temperature = 125°C
48 units from 3 production lots
250
Operating Current (mA)
35
Number of Occurrences
0.5
Temperature Error (°C)
G042
Figure 26.
30
25
20
15
10
VDD = 5V
200
150
VDD = 3.3V
VDD = 2V
100
50
5
0
0.5
0.4
0.3
0.2
0.1
0
−0.1
−0.2
−0.3
−0.4
−0.5
0
-40
-20
0
SHUTDOWN CURRENT vs TEMPERATURE
80
100
120
140
FREQUENCY RESPONSE
0
VDD = 2V
VDD = 3.3V
VDD = 5V
Data Rate = 8SPS
-10
-20
Gain (dB)
3.5
3
2.5
2
1.5
-30
-40
-50
-60
1
-70
0.5
0
−40
60
Figure 29.
5
4
40
G045
Figure 28.
4.5
20
Temperature (°C)
Temperature Error (°C)
Shutdown Current (µA)
0.4
−0.5
0.5
0.4
0.3
0.2
0.1
0
−0.1
0
−0.2
0
−0.3
5
−0.4
5
0.3
10
0.2
10
20
0.1
15
25
0
20
30
−0.1
25
Ambient temperature = 70°C
48 units from 3 production lots
−0.2
Number of Occurrences
30
−0.5
Number of Occurrences
35
−0.3
Ambient temperature = 25°C
48 units from 3 production lots
35
−0.4
40
−20
0
20
40
60
80
Temperature (°C)
Figure 30.
Copyright © 2010–2011, Texas Instruments Incorporated
100
120
140
G003
-80
1
10
100
1k
10k
Input Frequency (Hz)
Figure 31.
11
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
OVERVIEW
The ADS1118 is a very small, low-power, 16-bit, delta-sigma (ΔΣ) analog-to-digital converter (ADC). The
ADS1118 is extremely easy to configure and design into a wide variety of applications, and allows precise
measurements to be obtained with very little effort. Both experienced and novice users of data converters find
designing with the ADS1118 family to be intuitive and problem-free.
The ADS1118 consists of a ΔΣ analog-to-digital (A/D) core with adjustable gain, an internal voltage reference, a
clock oscillator, and an SPI. This device is also a highly linear and accurate temperature sensor. All of these
features are intended to reduce required external circuitry and improve performance. Figure 32 shows the
ADS1118 functional block diagram.
VDD
Device
Voltage
Reference
MUX
AIN0
Gain = 2/3, 1,
2, 4, 8, or 16
CS
SCLK
AIN1
PGA
16-Bit DS
ADC
SPI
Interface
DIN
DOUT/DRDY
AIN2
Oscillator
AIN3
Temperature
Sensor
GND
Figure 32. ADS1118 Functional Block Diagram
The ADS1118 A/D core measures a differential signal, VIN, that is the difference of AINP and AINN. The converter
core consists of a differential, switched-capacitor ΔΣ modulator followed by a digital filter. This architecture
results in a very strong attenuation in any common-mode signals. Input signals are compared to the internal
voltage reference. The digital filter receives a high-speed bitstream from the modulator and outputs a code
proportional to the input voltage.
The ADS1118 has two available conversion modes: single-shot mode and continuous conversion mode. In
single-shot mode, the ADC performs one conversion of the input signal upon request and stores the value to an
internal conversion register. The device then enters a low-power shutdown mode. This mode is intended to
provide significant power savings in systems that require only periodic conversions or when there are long idle
periods between conversions. In continuous conversion mode, the ADC automatically begins a conversion of the
input signal as soon as the previous conversion is completed. The rate of continuous conversion is equal to the
programmed data rate. Data can be read at any time and always reflect the most recent completed conversion.
12
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
MULTIPLEXER
The ADS1118 contains an input multiplexer, as shown in Figure 33. Either four single-ended or two differential
signals can be measured. Additionally, AIN0 and AIN1 may be measured differentially to AIN3. The multiplexer is
configured by three bits in the Config Register. When single-ended signals are measured, the negative input of
the ADC is internally connected to GND by a switch within the multiplexer.
VDD
Device
AIN0
VDD
GND
AINP
AIN1
AINN
VDD
GND
AIN2
VDD
GND
AIN3
GND
GND
Figure 33. ADS1118 MUX
When measuring single-ended inputs, it is important to note that the negative range of the output codes are not
used. These codes are for measuring negative differential signals, such as (AINP – AINN) < 0. Electrostatic
discharge (ESD) diodes to VDD and GND protect the inputs. To prevent the ESD diodes from turning on, the
absolute voltage on any input must stay within the range of Equation 1:
GND – 0.3V < AINx < VDD + 0.3V
(1)
If it is possible that the voltages on the input pins may violate these conditions, external Schottky clamp diodes
and/or series resistors may be required to limit the input current to safe values (see the Absolute Maximum
Ratings table). While the analog inputs can support signals marginally above supply, under no circumstances
should any analog or digital input or output be driven to greater than 5.5V with respect to the GND pin.
Also, overdriving one unused input on the ADS1118 may affect conversions taking place on other input pins. If
overdrive on unused inputs is possible, it is recommended to clamp the signal with external Schottky diodes.
Copyright © 2010–2011, Texas Instruments Incorporated
13
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
ANALOG INPUTS
The ADS1118 uses a switched-capacitor input stage where capacitors are continuously charged and then
discharged to measure the voltage between AINP and AINN. The capacitors used are small, and to external
circuitry, the average loading appears resistive. This structure is shown in Figure 34. The resistance is set by the
capacitor values and the rate at which they are switched. Figure 35 shows the on/off setting of the switches
illustrated in Figure 34. During the sampling phase, switches S1 are closed. This event charges CA1 to AINP, CA2
to AINN, and CB to (AINP – AINN). During the discharge phase, S1 is first opened and then S2 is closed. Both CA1
and CA2 then discharge to approximately 0.7V and CB discharges to 0V. This charging draws a very small
transient current from the source driving the ADS1118 analog inputs. The average value of this current can be
used to calculate the effective impedance (Reff), where Reff = VIN/IAVERAGE.
0.7V
CA1
AINP
S1
ZCM
S2
0.7V
Equivalent
Circuit
AINP
CB
S1
ZDIFF
S2
AINN
AINN
0.7V
ZCM
CA2
fCLK = 250kHz
0.7V
Figure 34. Simplified Analog Input Circuit
tSAMPLE
ON
S1
OFF
ON
S2
OFF
Figure 35. S1 and S2 Switch Timing for Figure 34
The common-mode input impedance is measured by applying a common-mode signal to the shorted AINP and
AINN inputs and measuring the average current consumed by each pin. The common-mode input impedance
changes depending on the PGA gain setting, but is approximately 6MΩ for the default PGA gain setting. In
Figure 34, the common-mode input impedance is ZCM.
The differential input impedance is measured by applying a differential signal to AINP and AINN inputs where one
input is held at 0.7V. The current that flows through the pin connected to 0.7V is the differential current and
scales with the PGA gain setting. In Figure 34, the differential input impedance is ZDIFF. Table 1 describes the
typical differential input impedance.
Table 1. Differential Input Impedance
FS (V)
(1) (1)
±6.144V
(1)
14
DIFFERENTIAL INPUT IMPEDANCE
22MΩ
±4.096V(1) (1)
15MΩ
±2.048V
4.9MΩ
±1.024V
2.4MΩ
±0.512V
710kΩ
±0.256V
710kΩ
This parameter expresses the full-scale range of the ADC scaling. In
no event should more than VDD + 0.3V be applied to this device.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
The typical value of the input impedance cannot be neglected. Unless the input source has a low impedance, the
ADS1118 input impedance may affect the measurement accuracy. For sources with high output impedance,
buffering may be necessary. Note that active buffers introduce noise, and also introduce offset and gain errors.
All of these factors should be considered in high-accuracy applications.
Because the clock oscillator frequency drifts slightly with temperature, the input impedances also drift. For many
applications, this input impedance drift can be ignored, and the values given in Table 1 for typical input
impedance are valid.
FULL-SCALE INPUT
A PGA is implemented before the ΔΣ core of the ADS1118. The PGA can be set to gains of 2/3, 1, 2, 4, 8, and
16. Table 2 shows the corresponding full-scale (FS) ranges. The PGA is configured by three bits in the Config
register. The PGA = 2/3 setting allows input measurement to extend up to the supply voltage when VDD is larger
than 4V. Note, however, in this case (as well as for PGA = 1 and VDD < 4V) that it is not possible to reach a
full-scale output code on the ADC. Analog input voltages may never exceed the analog input voltage limits given
in the Electrical Characteristics table.
Table 2. PGA Gain Full-Scale Range
(1)
PGA SETTING
FS (V)
2/3
±6.144V(1) (1)
1
±4.096V(1)
2
±2.048V
4
±1.024V
8
±0.512V
16
±0.256V
This parameter expresses the full-scale range of the ADC scaling. In
no event should more than VDD + 0.3V be applied to this device.
Copyright © 2010–2011, Texas Instruments Incorporated
15
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
DATA FORMAT
The ADS1118 provides 16 bits of data in binary twos complement format. The positive full-scale input produces
an output code of 7FFFh and the negative full-scale input produces an output code of 8000h. The output clips at
these codes for signals that exceed full-scale. Table 3 summarizes the ideal output codes for different input
signals. Figure 36 shows code transitions versus input voltage.
Table 3. Input Signal versus Ideal Output Code
INPUT SIGNAL, VIN
(AINP – AINN)
15
≥ FS (2
IDEAL OUTPUT CODE (1)
15
– 1)/2
7FFFh
+FS/215
0001h
0
0
15
–FS/2
FFFFh
≤ –FS
(1)
8000h
Excludes the effects of noise, INL, offset, and gain errors.
0x7FFF
0x0001
0x0000
0xFFFF
¼
Output Code
¼
0x7FFE
0x8001
0x8000
¼
-FS
2
15
-FS
2
0
¼
FS
Input Voltage (AINP - AINN)
-1
15
2
15
FS
2
-1
15
Figure 36. ADS1118 Code Transition Diagram
16
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
TEMPERATURE SENSOR
The temperature measurement mode of the ADS1118 is configured as a 14-bit result when enabled. Two bytes
must be read to obtain data. The first byte is the most significant byte (MSB), followed by a second byte, the
least significant byte (LSB). The first 14 bits are used to indicate temperature. That is, the 14-bit temperature
result is left-justified within the 16-bit result register and the last two bits always read back as '0'. One 14-bit LSB
equals 0.03125°C. Negative numbers are represented in binary twos complement format.
Table 4. 14-bit Temperature Data Format
TEMPERATURE (°C)
DIGITAL OUTPUT (BINARY)
HEX
128
01 0000 0000 0000
1000
127.96875
00 1111 1111 1111
0FFF
100
00 1100 1000 0000
0C80
80
00 1010 0000 0000
0A00
75
00 1001 0110 0000
0960
50
00 0110 0100 0000
0640
25
00 0011 0010 0000
0320
0.25
00 0000 0000 1000
0008
0
00 0000 0000 0000
0000
–0.25
11 1111 1111 1000
3FF8
–25
11 1100 1110 0000
3CE0
–55
11 1001 0010 0000
3920
Converting from Temperature to Digital Codes
For positive temperatures (for example, +50°C):
Twos complement is not performed on positive numbers. Therefore, simply convert the number to binary
code in a 14-bit left justified format with the MSB = 0 to denote the positive sign.
Example: (+50°C)/(0.03125°C/count) = 1600 = 0640h = 00 0110 0100 0000
For negative temperatures (for example –25°C):
Generate the twos complement of a negative number by complementing the absolute binary number and
adding 1. Then denote the negative sign with the MSB = 1.
Example:(|–25°C|)/(0.03125°C/count) = 800 = 0320h = 00 0011 0010 0000
Twos complement format: 11 1100 1101 1111 + 1 = 11 1100 1110 0000
Converting from Digital Codes to Temperature
To convert from digital codes to temperature, first check whether the MSB is a '0' or a '1'. If the MSB is a '0',
simply multiply the decimal code by 0.03125°C to obtain the result. If the MSB = 1, subtract '1' from the result
and complement all of the bits. Then multiply the result by –0.03125°C.
Example: ADS1118 reads back 0960h: 0960h has an MSB = 0.
(0960h)(0.03125°C) = (2400)(0.03125°C) = +75°C
Example: ADS1118 reads back 3CE0h: 3CE0h has an MSB = 1.
Complement the result: 3CE0h → 0320h
(0320h)(–0.03125°C) = (800)(–0.03125°C) = –25°C
Copyright © 2010–2011, Texas Instruments Incorporated
17
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
ALIASING
As with any data converter, if the input signal contains frequencies greater than half the data rate, aliasing
occurs. To prevent aliasing, the input signal must be bandlimited. Some signals are inherently bandlimited; for
example, the output of a thermocouple has a limited rate of change. Nevertheless, these signals can contain
noise and interference components. These components can fold back into the sampling band in the same way as
with any other signal.
The ADS1118 digital filter provides some attenuation of high-frequency noise, but the digital sinc filter frequency
response cannot completely replace an anti-aliasing filter. For some applications, some external filtering may be
needed; in such instances, a simple RC filter is adequate.
When designing an input filter circuit, be sure to take into account the interaction between the filter network and
the input impedance of the ADS1118.
OPERATING MODES
The ADS1118 operates in one of two modes: continuous conversion or single-shot. In continuous conversion
mode, the ADS1118 continuously performs conversions. Once a conversion has been completed, the ADS1118
places the result in the Conversion Register and immediately begins another conversion. In single-shot mode,
the ADS1118 waits until the OS bit is set high. Once asserted, the bit is set to '0', indicating that a conversion is
currently in progress. Once conversion data are ready, the OS bit reasserts and the device powers down. Writing
a '1' to the OS bit during a conversion has no effect.
RESET AND POWER-UP
When the ADS1118 powers up, a reset is performed. As part of the reset process, the ADS1118 sets all of the
bits in the Config Register to the respective default settings. By default, the ADS1118 enters into a power-down
state at start-up. The device interface and digital are active, but no conversion occurs until the Config Register is
written to. The initial power-down state of the ADS1118 is intended to relieve systems with tight power-supply
requirements from encountering a surge during power-up.
DUTY CYCLING FOR LOW POWER
For many applications, improved performance at low data rates may not be required. For these applications, the
ADS1118 supports duty cycling that can yield significant power savings by periodically requesting high data rate
readings at an effectively lower data rate. For example, an ADS1118 in power-down mode with a data rate set to
860SPS could be operated by a microcontroller that instructs a single-shot conversion every 125ms (8SPS).
Because a conversion at 860SPS only requires about 1.2ms, the ADS1118 enters power-down mode for the
remaining 123.8ms. In this configuration, the ADS1118 consumes about 1/100th the power of the ADS1118
operated in continuous conversion mode. The rate of duty cycling is completely arbitrary and is defined by the
master controller.
SERIAL INTERFACE
The SPI-compatible serial interface consists of either four signals: CS, SCLK, DIN, and DOUT/DRDY; or three
signals, in which case CS may be tied low. The interface is used to read conversion data, read and write
registers, and control the ADS1118 operation.
CHIP SELECT (CS)
The chip select (CS) selects the ADS1118 for SPI communication. This feature is useful when multiple devices
share the serial bus. CS must remain low for the duration of the serial communication. When CS is taken high,
the serial interface is reset, SCLK is ignored, and DOUT/DRDY enters a high-impedance state; as such,
DOUT/DRDY cannot provide indication of data ready. In situations where multiple devices are present and
DOUT/DRDY must be monitored; by periodically lowering CS, the DOUT/DRDY pin either immediately goes high
to indicate that no new data are available, or it immediately goes low, to indicate that new data are present in the
Config Register and are available for transfer. New data can be transferred at anytime without concern of data
corruption. When a transmission starts, the current result is locked into the output shift register and does not
change until the communication is completed. This system avoids any possibility of data corruption.
18
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
www.ti.com
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
SERIAL CLOCK (SCLK)
The serial clock (SCLK) features a Schmitt-triggered input and is used to clock data on the DIN and
DOUT/DRDY pins into and out of the ADS1118. Even though the input has hysteresis, it is recommended to
keep SCLK as clean as possible to prevent glitches from accidentally shifting the data. If SCLK is held low for
28ms, the serial interface resets and the next SCLK pulse starts a new communication cycle. This timeout
feature can be used to recover communication when a serial interface transmission is interrupted. When the
serial interface is idle, hold SCLK low.
DATA INPUT (DIN)
The data input pin (DIN) is used along with SCLK to send data to the ADS1118 (op code commands and register
data). The device latches data on DIN on the falling edge of SCLK. The ADS1118 never drives the DIN pin.
DATA OUTPUT AND DATA READY (DOUT/DRDY)
The data output and data ready pin (DOUT/DRDY) are used with SCLK to read conversion and register data
from the ADS1118. In Read Data Continuous mode, DOUT/DRDY goes low when conversion data are ready and
goes high 8µs before the data ready signal. Data on DOUT/DRDY are shifted out on the rising edge of SCLK. By
default DOUT/DRDY goes to a high-impedance state when CS is high. Alternatively, the ADS1118 DOUT/DRDY
pin can be configured as a weak pull-up if CS is high. This feature is intended to reduce the risk of DOUT/DRDY
floating near midsupply and causing leakage current in the master. If the ADS1118 does not share the serial bus
with another device, CS may be tied low.
POWER-DOWN MODE
When the PWDN bit in the Config Register is set to '1', the ADS1118 enters a lower power standby state. This
condition is also the default state the ADS1118 enters when power is first supplied. In this mode, the ADS1118
uses no more than 2μA of current. During this time, the device responds to commands, but does not perform any
data conversion. To exit this mode, simply write a '0' to the PWDN bit in the Config Register.
Copyright © 2010–2011, Texas Instruments Incorporated
19
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
REGISTERS
The ADS1118 has two registers that are accessible via the SPI port. The Conversion Register contains the result
of the last conversion. The Config Register allows the modification of the ADS1118 operating modes and the
ability to query the status of the device.
Conversion Register
This 16-bit register contains the result of the last conversion in binary twos complement format. Following
power-up, the Conversion Register is cleared to '0', and remains '0' until the first conversion is completed.
The register format is shown in Table 5.
Table 5. Conversion Register (Read-Only)
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NAME
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Config Register
The 16-bit register can be used to control the ADS1118 operating mode, input selection, data rate, PGA settings,
and comparator modes. The register format is shown in Table 6.
Table 6. Config Register (Read/Write)
BIT
15
14
13
12
11
10
9
8
NAME
OS
MUX2
MUX1
MUX0
PGA2
PGA1
PGA0
MODE
BIT
7
6
5
4
3
2
1
0
NAME
DR2
DR1
DR0
TS_MODE
PULL_UP_
EN
NOP1
NOP2
CNV_RDY_FL
blank
Default = 8583h.
Bit 15
OS: Operational status/single-shot conversion start
This bit determines the operational status of the device.
This bit can only be written when in power-down mode.
For a write status:
0 : No effect
1 : Begin a single conversion (when in power-down mode)
For a read status:
0 : Device is currently performing a conversion
1 : Device is not currently performing a conversion
Bits[14:12]
MUX[2:0]: Input multiplexer configuration
These bits configure the input multiplexer. No effect when in temperature sensor mode.
000 : AINP = AIN0 and AINN = AIN1 (default)
001 : AINP = AIN0 and AINN = AIN3
010 : AINP = AIN1 and AINN = AIN3
011 : AINP = AIN2 and AINN = AIN3
Bits[11:9]
100 : AINP = AIN0 and AINN = GND
101 : AINP = AIN1 and AINN = GND
110 : AINP = AIN2 and AINN = GND
111 : AINP = AIN3 and AINN = GND
PGA[2:0]: Programmable gain amplifier configuration
These bits configure the programmable gain amplifier. No effect when in temperature sensor mode.
000 : FS = ±6.144V (1)
001 : FS = ±4.096V (1)
010 : FS = ±2.048V (default)
011 : FS = ±1.024V
Bit 8
100 : FS = ±0.512V
101 : FS = ±0.256V
110 : FS = ±0.256V
111 : FS = ±0.256V
MODE: Device operating mode
This bit controls the current operational mode of the ADS1118.
0 : Continuous conversion mode
1 : Power-down single-shot mode (default)
(1)
20
This parameter expresses the full-scale range of the ADC scaling. In no event should more than VDD + 0.3V be applied to this device.
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
Bits[7:5]
DR[2:0]: Data rate
These bits control the data rate setting.
000 : 8SPS
001 : 16SPS
010 : 32SPS
011 : 64SPS
Bit 4
100 : 128SPS (default)
101 : 250SPS
110 : 475SPS
111 : 860SPS
TS_MODE: Temperature sensor mode
This bit configures the ADC to convert temperature or input signals.
0 : ADC mode (default)
1 : Temperature sensor mode
Bit 3
PULL_UP_EN: Pull-up enable
This bit enables a weak pull-up resistor on the DOUT pin when CS is high. When enabled, a 400kΩ resistor
connects the bus line to supply when CS is high. When disabled, the DOUT pin floats when CS is high.
0 : Pull-up resistor disabled on DOUT pin (default)
1 : Pull-up resistor enabled on DOUT pin
Bits[2:0]
NOP: No operation
The NOP bits control whether data are written to the Config Register or not. In order for data to be written to
the Config Register, the NOP bits must be written as '01'. Any other value written to the NOP bits results in a
NOP command. This means that DIN can be held high or low during SCLK pulses without data being written to
the Config Register.
00 : Invalid data, do not update the contents of the Config Register.
01 : Valid data, update the Config Register (default)
10 : Invalid data, do not update the contents of the Config Register.
11: Invalid data, do not update the contents of the Config Register.
Bit 0
CNV_RDY_FL: Conversion ready flag
This bit is active low and indicates when data are ready from the converter. When it is high, a conversion is not
yet ready and is in process. The purpose of the conversion ready flag bit is to return the DOUT pin line to a
high state to prepare for the falling edge from new data.
0 : Data ready, no conversion in progress
1 : Data not ready, conversion in progress (default)
Copyright © 2010–2011, Texas Instruments Incorporated
21
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
DATA RETRIEVAL
Data may be read in one of two modes: Single-Shot and Continuous Conversion mode. The mode is selected by
writing to the OS bit in the Config Register.
Continuous Conversion Mode
In Continuous Conversion mode, the conversion data are read from the device without an op code command.
When DOUT/DRDY asserts low (indicating that new conversion data are ready), the conversion data are read by
shifting the data out on DOUT. The MSB of the data (bit 15) on DOUT/DRDY is clocked out on the first rising
edge of SCLK.
As shown in Figure 37, the data consist of two bytes for the conversion result and an additional two bytes for the
Config Register readback. The data read operation must be completed 16/fCLK cycles before DOUT asserts
again.
(1)
CS
1
9
17
25
SCLK
DOUT
Hi-Z
DIN
DATA MSB
DATA LSB
CONFIG MSB
CONFIG LSB
CONFIG MSB
CONFIG LSB
CONFIG MSB
CONFIG LSB
Next Data
Ready
(1) CS may be held low. If CS is low, DOUT/DRDY asserts low indicating new data.
Figure 37. Continuous Conversion Mode Timing
One-Shot Mode
In One-Shot mode, the conversion data are buffered, holding the current data until new conversion data replace
it. The conversion data are read by writing a '1' to the OS bit, followed by shifting the conversion data out.
The data consist of two bytes for the conversion result and two bytes for the Config Register; see Figure 38. In
contrast to the Continuous Conversion mode, DOUT does not assert low in one-shot mode.
(1)
CS
1
9
17
25
tUPDATE
SCLK
DOUT
DIN
Hi-Z
Data
Ready
DATA MSB
DATA LSB
CONFIG MSB
CONFIG LSB
CONFIG MSB
CONFIG LSB
CONFIG MSB
CONFIG LSB
Next Data
Ready
(1) CS may be held low. If CS is low, DOUT/DRDY asserts low indicating new data.
Figure 38. One-Shot Mode Timing
22
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
APPLICATION INFORMATION
The following sections give example circuits and suggestions for using the ADS1118 in various situations.
BASIC CONNECTIONS AND LAYOUT CONSIDERATIONS
For many applications, connecting the ADS1118 is simple. A basic connection diagram for the ADS1118 is
shown in Figure 39. Most microcontroller SPI peripherals can operate with the ADS1118. The interface operates
in SPI mode 1 where CPOL = 0 and CPHA = 1. In SPI mode 1, SCLK idles low and data launch or are changed
only on rising edges of SCLK and data are latched or read by the master and slave on falling edges of SCLK.
Details of the SPI communication protocol employed by the ADS1118 can be found in the SPI Timing
Characteristics section. Although it is not required, it is a good practice to place 49.9Ω resistors in series with all
of the digital pins. This resistance smooths sharp transitions, suppresses overshoot, and offers some overvoltage
protection.
Device
10
VDD
DIN
Microcontroller or
Microprocessor
with SPI Port
1
SCLK
DOUT/DRDY
9
2
CS
VDD
8
3
GND
AIN3
7
4
AIN0
AIN2
6
0.1mF (typ)
AIN1
5
DOUT
DIN
Inputs Selected
from Configuration
Register
CS
SCLK
Figure 39. Typical Connections of the ADS1118
The fully differential voltage input of the ADS1118 is ideal for connection to differential sources with moderately
low source impedance, such as thermocouples and thermistors. Although the ADS1118 can read bipolar
differential signals, it cannot accept negative voltages on either input because every pin on the ADS1118
employs the use of ESD protection diodes. In the event that an input exceeds supply or drops below ground,
these diodes begin to turn on. Therefore, it may be helpful to think of the ADS1118 positive voltage input as
noninverting, and of the negative input as inverting.
When the ADS1118 is converting data, it draws current in short spikes. The 0.1μF bypass capacitor supplies the
momentary bursts of extra current needed from the supply. This bypass capacitor should be placed as close to
the device as possible. For very sensitive systems, or systems in harsh noise environments, avoiding the use of
vias for connecting the bypass capacitor may offer superior bypass and noise immunity.
Copyright © 2010–2011, Texas Instruments Incorporated
23
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
It is recommended to employ best design practices when laying out a printed circuit board (PCB) for both analog
and digital components. This recommendation generally means that the layout should separate analog
components [such as ADCs, op amps, references, digital-to-analog converters (DACs), and analog MUXs] from
digital components [such as microcontrollers, complex programmable logic devices (CPLDs), field-programmable
gate arrays (FPGAs), radio frequency (RF) tranceivers, universal serial bus (USB) tranceivers, and switching
regulators]. An example of good component placement is shown in Figure 40. While Figure 40 provides a good
example of component placement, the best placement for each application is unique to the geometries,
components, and PCB fabrication capabilities being employed. That is, there is no single layout that is perfect for
every design and careful consideration must always be used when designing with any analog components.
ADS1118
Ground fill or
Ground plane
Microprocessor
Optional: Split
Ground Cut
Signal
Conditioning
(RC filters
and
amplifiers)
Ground fill or
Ground plane
Optional: Split
Ground Cut
Ground fill or
Ground plane
Supply
Generation
Interface
Tranceiver
Connector
or Antenna
Ground fill or
Ground plane
Figure 40. System Component Placement
The usage of split analog and digital ground planes is not necessary for improved noise performance (although
for thermal isolation it is a worthwhile consideration). However, the use of a solid ground plane or ground fill in
PCB areas with no components is essential for optimum performance. If the system being used employs a split
digital and analog ground plane, it is generally recommended that the ground planes be connected as close to
the ADS1118 as possible. It is also strongly recommended that digital components, especially RF portions, be
kept as far as practically possible from analog circuitry in a given system. Additionally, minimize the distance that
digital control traces run through analog areas and avoid allowing these traces to be near sensitive analog
components. Digital return currents usually flow through a ground path that is as close to the digital path as
possible. If a solid ground connection to a plane is not available, these currents may find paths back to the
source that interfere with analog performance. The implications that layout has on the temperature sensing
functions are much more significant than they are for the ADC functions. Details on layout considerations for the
temperature sensor can be found in the Thermocouple Measurement with Cold Junction Compensation section.
For a detailed layout example, refer to the ADS1118EVM User's Guide (SBAU184).
24
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
CONNECTING MULTIPLE DEVICES
Connecting multiple ADS1118s to a single bus is simple. Using a dedicated chip-select (CS) for each SPI
enabled device, SCLK, DIN, and DOUT/DRDY can be safely shared. By default, when CS goes high for the
ADS1118, DOUT/DRDY enters a 3-state mode. If the PULL_UP_EN bit is enabled, the DOUT/DRDY pin is
pulled up to the supply of the ADS1118 by a weak 400kΩ resistor. This feature is intended to prevent
DOUT/DRDY from floating near mid-rail and causing excess current leakage on a microcontroller input. The
ADS1118 cannot issue a data ready pulse on DOUT/DRDY when CS is high. In order to evaluate when a new
conversion is ready from the ADS1118 when using multiple devices, the master can periodically drop CS to the
ADS1118. When CS lowers, the DOUT/DRDY pin immediately drives either high or low. If the DOUT/DRDY line
drives low on a low CS, new data are currently available for clocking out at any time. If the DOUT/DRDY line
drives high, no new data are available and the ADS1118 returns the last read conversion result. Valid data can
be retrieved from the ADS1118 at anytime without concern of data corruption. When SCLK rises, the current
result is locked into DOUT/DRDY the output shift register. If a new conversion becomes available during data
transmission, it is not avialable for readback until a new SPI transmission is initiated.
Microcontroller or
Microprocessor
ADS1118
SCLK
DIN
10 DIN
1 SCLK DOUT/DRDY 9
2 CS
VDD
8
DOUT
3 GND
AIN3
7
CS1
4 AIN0
AIN2
6
AIN1
5
CS2
ADS1118
10 DIN
1 SCLK DOUT/DRDY 9
2 CS
VDD
8
3 GND
AIN3
7
AIN2
6
4 AIN0
AIN1
5
NOTE: Power and input connections omitted for clarity.
Figure 41. Connecting Multiple ADS1118s
Copyright © 2010–2011, Texas Instruments Incorporated
25
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
USING GPIO PORTS FOR COMMUNICATION
Most microcontrollers have programmable input/output (I/O) pins that can be set in software to act as inputs or
outputs. If an SPI controller is not available, the ADS1118 can be connected to GPIO pins and the SPI bus
protocol can be simulated. Using GPIO pins to generate the SPI interface only requires that the pins be
configured as push/pull inputs or outputs. Furthermore, if the SCLK line is held low for more than 28ms, the
communication times out. This condition means that the GPIO ports must be capable of providing SCLK pulses
with no more than 28ms between pulses.
SINGLE-ENDED INPUTS
Although the ADS1118 has two differential inputs, the device can easily measure four single-ended signals.
Figure 42 shows a single-ended connection scheme. The ADS1118 is configured for single-ended measurement
by configuring the MUX to measure each channel with respect to ground. Data are then read out of one input
based on the selection in the Config Register. The single-ended signal can range from 0V to supply. The
ADS1118 loses no linearity anywhere within the input range. Negative voltages cannot be applied to this circuit
because the ADS1118 can only accept positive voltages.
The ADS1118 input range is bipolar differential. The single-ended circuit shown in Figure 42 covers only half the
ADS1118 input scale because it does not produce differentially negative inputs; therefore, one bit of resolution is
lost. For optimal noise performance, it is recommended to use differential configurations whenever possible.
Differential configurations maximize the dynamic range of the ADC and provide strong attenuation of
common-mode noise.
VDD
Device
10
DIN
1
SCLK
DOUT/DRDY
9
2
CS
VDD
8
3
GND
AIN3
7
4
AIN0
AIN2
6
0.1mF (typ)
AIN1
5
Inputs Selected
from Configuration
Register
NOTE: Digital pin connections omitted for clarity.
Figure 42. Measuring Single-Ended Inputs
The ADS1118 is also designed to allow AIN3 to serve as a common point for measurements by adjusting the
MUX configuration. AIN0, AIN1, and AIN2 can all be measured with respect to AIN3. In this configuration the
ADS1118 can operate with inputs where AIN3 serves as the common point. This ability improves the usable
range over the single-ended configuration because it allows negative voltages; however, it does not offer
attenuation of common-mode noise.
26
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
THERMOCOUPLE MEASUREMENT WITH COLD JUNCTION COMPENSATION
For an independent, two-channel thermocouple system, Figure 43 shows the basic connections. This circuit
contains a simple low-pass, anti-aliasing filter, mid-point bias, and open detection. While the digital filter of the
ADS1118 strongly attenuates high-frequency components of noise, it is generally recommended to provide a
first-order passive RC filter to further improve this performance. The differential RC filter formed by the 500Ω
resistors (RDIFFA and RDIFFB) and the 1µF (CDIFF) capacitor offers a cutoff frequency of approximately 320Hz.
Additional filtering can be achieved by increasing the differential capacitor or the resistance values. However,
avoid increasing the filter resistance beyond 1kΩ because the effects of the interaction with ADCs input
impedance begin to affect the linearity and gain error of the ADS1118. Because of the high sampling rates
supported by the ADS1118, simple post digital filtering in a microcontroller can alleviate the requirements of the
analog filter and can also offer the flexibility to implement filter notches at 50Hz or 60Hz. Two 0.1µF (CCMA and
CCMB) capacitors are also added to offer attenuation of high-frequency common-mode noise components.
Because mismatches in the common-mode capacitors cause differential noise, it is recommended that the
differential capacitor be at least an order of magnitude (10x) larger than the common-mode capacitors.
3.3V
0.1 F
GND
3.3V
RPU = 1Mȍ
GND
CCMA = 0.1 F
500ȍ
AIN0
VDD
RDIFFA
CDIFF = 1 F
AIN1
RDIFFB
RPD = 1Mȍ
500ȍ
(PGA Gain = 16)
±256mV FS
CCMB = 0.1 F
Voltage
Reference
SCLK
GND
GND
PGA
GND
3.3V
RPU = 1Mȍ
MUX
16-bit
Ȉǻ
ADC
Digital Filter
and
Interface
DIN
CCMA = 0.1 F
500ȍ
CS
DOUT/DRDY
AIN2
RDIFFA
CDIFF = 1 F
RPD = 1Mȍ
GND
Oscillator
AIN3
RDIFFB
500ȍ
Temp Sensor
GND
CCMB = 0.1 F
GND
GND
Figure 43. Two-Channel Thermocouple System
Copyright © 2010–2011, Texas Instruments Incorporated
27
ADS1118
SBAS457A – OCTOBER 2010 – REVISED JULY 2011
www.ti.com
The two 1MΩ resistors (RPU and RPD) serve two purposes. The first purpose is to offer a common-mode bias
near midsupply. While the ADS1118 does offer the ability to float the common-mode of a signal or connect any of
the inputs to a common point such as ground or supply, it is generally recommended to avoid such situations.
Connecting one of the inputs to a common point decreases performance by converting common-mode noise into
differential signal noise that is not strongly attenuated. The second purpose of the 1MΩ resistors is to offer a
weak pull-up and pull-down for sensor open detection. In the event that a sensor is disconnected, the inputs to
the ADC extend to supply and ground and yield a full-scale readout, indicating a sensor disconnection.
The procedure to actually achieve cold junction compensation is simple and can be done in several ways. One
way is to interleave readings between the thermocouple inputs and the temperature sensor. That is, acquire one
on-chip temperature result for every thermocouple ADC voltage measured. If the cold junction is in a very stable
environment, more periodic cold junction measurements may be sufficient. These operations yield two results for
every thermocouple measurement and cold junction measurement cycle: the thermocouple voltage or VTC and
the on-chip temperature or TCJC. In order to account for the cold junction, the temperature sensor within the
ADS1118 must first be converted to a voltage proportional to the thermocouple currently being used yielding
VCJC. This conversion is generally accomplished by performing a reverse lookup on the table being used for the
thermocouple voltage to temperature conversion. Then, adding the two voltages yields the thermocouple
compensated voltage VActual where VCJC + VTC = VActual. VActual is then converted to temperature using the same
lookup table from before, yielding TActual.
Thermocouple manufacturers usually supply a lookup table with their thermocouples that offer excellent accuracy
for linearization of a specific type of thermocouple. The granularity on these lookup tables is generally very
precise (at around 1°C for each lookup value). To save microcontroller memory and development time, an
interpolation technique applied to these values can be used. By choosing 16 to 32 equally-spaced values from
the manufacturer's lookup tables over a desired temperature range, using a simple linear approximation of
intervals between is generally very precise.
28
Copyright © 2010–2011, Texas Instruments Incorporated
PACKAGE OPTION ADDENDUM
www.ti.com
25-Jul-2011
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package
Drawing
Pins
Package Qty
Eco Plan
(2)
Lead/
Ball Finish
MSL Peak Temp
(3)
Samples
(Requires Login)
ADS1118IDGSR
ACTIVE
MSOP
DGS
10
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
ADS1118IDGST
ACTIVE
MSOP
DGS
10
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
ADS1118IRUGR
PREVIEW
X2QFN
RUG
10
TBD
Call TI
Call TI
ADS1118IRUGT
PREVIEW
X2QFN
RUG
10
TBD
Call TI
Call TI
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
22-Jul-2011
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
ADS1118IDGSR
MSOP
DGS
10
2500
330.0
12.4
5.3
3.3
1.3
8.0
12.0
Q1
ADS1118IDGST
MSOP
DGS
10
250
180.0
12.4
5.3
3.3
1.3
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
22-Jul-2011
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
ADS1118IDGSR
MSOP
DGS
10
2500
370.0
355.0
55.0
ADS1118IDGST
MSOP
DGS
10
250
195.0
200.0
45.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and
Automotive
www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
Wireless
www.ti.com/wireless-apps
RF/IF and ZigBee® Solutions
www.ti.com/lprf
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
Similar pages