Data Sheet September 14, 2012 EBVW006A0B Series (Eighth-Brick) DC-DC Converter Power Modules 36 - 75Vdc Input; 12V/6Adc Output Barracuda Series™ Features RoHS Compliant Applications Distributed Power Architectures Wireless Networks Access and Optical Network Equipment Industrial Equipment Options Negative Remote On/Off logic (preferred) Overcurrent/Overtemperature/Overvoltage protections (Auto-restart) (preferred) Heat plate version (-H) Surface Mount version (-S) Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Flat and high-efficiency curve Industry standard, DOSA compliant footprint 57.9mm x 22.8mm x 7.6mm (2.28 in x 0.9 in x 0.30 in) Low-profile height and reduced component skyline Ultra-wide input voltage range: 36-75 Vdc Tightly regulated output Remote sense Output voltage adjust: 90% to 110% of VO,nom Constant switching frequency Positive remote On/Off logic Input under/overvoltage protection Output overcurrent and overvoltage protection Overtemperature protection No reverse current during output shutdown Wide operating temperature range (-40°C to 85°C) Suitable for cold wall cooling using suitable Gap Pad applied directly to top side of module † UL*Recognized to UL60950-1, CAN/CSA C22.2 ‡ No.60950-1, and EN60950-1(VDE 0805-1) Licensed § CE mark meets 2006/95/EC directive Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for basic insulation rating per EN60950-1 2250 Vdc Isolation tested in compliance with IEEE ¤ 802.3 PoE standards ** ISO 9001 and ISO 14001 certified manufacturing facilities Description The EBVW006A0B [Barracuda™] Series, eighth-brick, low-height power modules are isolated DC-DC converters that provide a single, precisely regulated output voltage over an input voltage range of 36-75Vdc. The EBVW006A0B provides 12Vdc nominal output voltage rated for 6Adc output current. The module incorporates Lineage Power’s vast heritage for reliability and quality, while also using the latest in technology and component and process standardization to achieve highly competitive cost. The open frame module construction, available in both surface mount and through-hole packaging, enables designers to develop cost and space efficient solutions. The module achieves typical full load efficiency greater than 90% at VIN=48Vdc. Standard features include remote On/Off, remote sense, output voltage adjustment, overvoltage, overcurrent and overtemperature protection. An optional heat plate allows for external standard, eighth-brick heat sink attachment to achieve higher output current in high temperature applications. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. § This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. ¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards ‡ Document No: ver. 1.1 PDF name: EBVW006A0B.pdf Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All VIN -0.3 80 Vdc Transient, operational (≤100 ms) All VIN,trans -0.3 100 Vdc All TA -40 85 °C Storage Temperature All Tstg -55 125 °C I/O Isolation Voltage (100% factory Hi-Pot tested) All 2250 Vdc Operating Ambient Temperature (see Thermal Considerations section) Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN= VIN, min to VIN, max, VO= VO, set, IO=IO, max) Input No Load Current (VIN = 48V, IO = 0, module enabled) Input Stand-by Current Device Symbol Min Typ Max Unit All VIN 36 48 75 Vdc All IIN 2.6 3.0 Adc All IIN,No load 80 IIN,stand-by 5 All (VIN = 48V, module disabled) I2t mA 8 mA 0.5 A2s Inrush Transient All Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ; See test configuration section) All 30 mAp-p Input Ripple Rejection (120Hz) All 50 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum DC input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. LINEAGE POWER 2 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Electrical Specifications (continued) Parameter Nominal Output Voltage Set-point VIN= 48V IO=IO, max, TA=25°C) Output Voltage (Overall operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (Tref=TA, min to TA, max) Output Ripple and Noise (VIN=VIN, min to VIN, max, IO= IO, max , TA=TA, min to TA, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) Device Symbol Min Typ Max Unit All VO, set 11.80 12.00 12.24 Vdc All VO 11.64 12.36 Vdc All All All ±0.2 ±0.2 ±1.0 % VO, set % VO, set % VO, set All 25 50 mVrms All 75 200 mVpk-pk 2,000 μF 6 Adc 9.0 Adc External Capacitance All CO, max 0 Output Current All IO 0 All IO, lim 6.6 All IO, s/c 5 Arms All η 90.0 % Output Current Limit Inception (Hiccup Mode ) (VO= 90% of VO, set) Output Short-Circuit Current (VO≤250mV) ( Hiccup Mode ) Efficiency VIN=48V, TA=25°C, IO=3A, VO = 12V 7.8 All η 90.5 % All fsw 280 kHz All Vpk 3 % VO, set All ts 200 µs Device Symbol Min Typ Max Unit Isolation Capacitance All Ciso 1000 pF Isolation Resistance All Riso 100 MΩ I/O Isolation Voltage (100% factory Hi-pot tested) All All 2250 Vdc Device Symbol Min Typ Max VIN=48V, TA=25°C, IO=6A, VO = 12V Switching Frequency Dynamic Load Response (dIo/dt=0.1A/µs; VIN = 48V; TA=25°C; CO>100μF) Load Change from Io= 50% to 75% or 25% to 50% of Io,max Peak Deviation Settling Time (Vo<10% peak deviation) Isolation Specifications Parameter General Specifications Parameter Unit 9 Calculated Reliability based upon Telcordia SR-332 Issue 2: Method I Case 3 (IO=80%IO, max, TA=40°C, airflow = 200 lfm, 90% confidence) All FIT 381.7 10 /Hours All MTBF 2,619,994 Hours Weight (Open Frame) All 19 (0.7) g (oz.) Weight (with Heat Plate) All 30 (1.1) g (oz.) LINEAGE POWER 3 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix “1” Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low - Remote On/Off Current All Ion/off 0.15 mA Logic Low - On/Off Voltage All Von/off -0.7 0.6 Vdc Logic High Voltage – (Typ = Open Collector) All Von/off 2.5 6.7 Vdc Logic High maximum allowable leakage current All Ion/off 25 μA Case 1: Input power is applied for at least 1 second then the On/Off input is set from OFF to ON (Tdelay = On/Off pin transition until VO = 10% of VO, set) All Tdelay ― 12 ― msec Case 2: On/Off input is set to Logic Low (Module ON) then input power is applied (Tdelay = VIN reaches VIN, min until Vo=10% of VO,set) All Tdelay ― 22 35 msec Output voltage Rise time (time for Vo to rise from 10% of Vo,set to 90% of Vo, set) All Trise ― 15 25 msec ― 3 % VO, set 10 % VO, set 110 % VO, set 16.5 Vdc Turn-On Delay and Rise Times (IO=IO, max , VIN=VIN, nom, TA = 25oC) Output Voltage Overshoot – Startup IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 oC All Remote Sense Range All Output Voltage Adjustment Range All Output Overvoltage Protection All VSENSE 90 VO, limit 13.8 Overtemperature Protection – Hiccup Auto Restart Heat Plate Input Undervoltage Lockout Open frame Heat Plate All Tref 135 O C Tref 120 O C VUVLO Turn-on Threshold 34 36 Vdc Turn-off Threshold 28 31 32 Vdc 1 2.0 Turn-on Threshold 76 77 Turn-off Threshold 79 81 Vdc Hysteresis 1 2 Vdc Hysteresis Input Overvoltage Lockout LINEAGE POWER All Vdc VOVLO Vdc 4 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Characteristic Curves o INPUT CURRENT, IIN (A) EFFICIENCY, η (%) The following figures provide typical characteristics for the EBVW006A0B (12.0V, 6A) at 25 C. The figures are identical for either positive or negative remote On/Off logic. OUTPUT CURRENT, IO (A) Figure 2. Input Current versus Output Current. OUTPUT VOLTAGE VO (V) (5V/div) OUTPUT VOLTAGE VO (V) (100mV/div) On/Off VOLTAGE VOn/Off (V) (5V/div) Figure 1. Converter Efficiency versus Output Current. OUTPUT CURRENT, IO (A) TIME, t (10ms/div) TIME, t (2µs/div) OUTPUT VOLTAGE VO (V) (5V/div) OUTPUT VOLTAGE OUTPUT CURRENT VO (V) (200mV/div) Io(A) (1A/div) TIME, t (200µs/div) Figure 5. Transient Response to 0.1A/µS Dynamic Load Change from 50% to 75% to 50% of full load, Vin=48V, CO>100μF. LINEAGE POWER Figure 4. Typical Start-up Using Remote On/Off, negative logic version shown (VIN = 48V, Io = Io,max). INPUT VOLTAGE VIN (V) (20V/div) Figure 3. Typical output ripple and noise (Io = Io,max). TIME, t (10ms/div) Figure 6. Typical Start-up Using Input Voltage (VIN = 48V, Io = Io,max). 5 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Test Configurations Design Considerations Input Filtering CURRENT PROBE TO OSCILLOSCOPE LTEST Vin+ BATTERY 12μH 33-100μF 220μF CS E.S.R.<0.1Ω @ 20°C 100kHz The power module should be connected to a low AC impedance source. Highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 7, a 33100μF electrolytic capacitor (ESR<0.7Ω at 100kHz), mounting close to the power module helps ensure the stability of the unit. Consult the factory for further application guidelines. Vin- Safety Considerations NOTE: Measure input reflected ripple current with a simulated source inductance (LTEST) of 12μH. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 7. Input Reflected Ripple Current Test Setup. COPPER STRIP VO (+) RESISTIVE LOAD SCOPE V O (– ) 1uF 10uF GROUND PLANE NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 8. Output Ripple and Noise Test Setup. Rdistribution Rcontact Rcontact Vin+ RLOAD VO VIN Rdistribution Rcontact Rcontact Vin- Rdistribution Vout+ Rdistribution Vout- NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 9. Output Voltage and Efficiency Test Setup. VO. IO Efficiency η = LINEAGE POWER VIN. IIN x 100 % For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950-1, CSA C22.2 No.60950-1, and VDE0805-1(IEC60950-1). If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module’s output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: The input source is to be provided with reinforced insulation from any other hazardous voltages, including the AC mains. One VIN pin and one VOUT pin are to be grounded, or both the input and output pins are to be kept floating. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system (combination of supply source and subject module) as required by the safety agencies to verify that under a single fault, hazardous voltages do not appear at the module’s output. Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. All flammable materials used in the manufacturing of these modules are rated 94V-0 or tested to the UL60950 A.2 for reduced thickness. For input voltages exceeding –60 Vdc but less than or equal to –75 Vdc, these converters have been evaluated to the applicable requirements of basic insulation between secondary DC mains distribution input (classified as TNV-2 in Europe) and unearthed SELV outputs. The input to these units is to be provided with a maximum 10 A fast-acting fuse in the ungrounded lead. 6 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Feature Descriptions Remote On/Off Two remote On/Off options are available. Positive logic turns the module on during a logic high voltage on the On/Off pin and off during a logic low. Negative logic remote On/Off, device code suffix “1”, turns the module off during a logic high and on during a logic low. Vin+ The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power (maximum rated power = Vo,set x Io,max). SENSE(+) Vout+ Ion/off SENSE(–) SUPPLY ON/OFF TRIM VI(+) VO(+) VI(-) VO(–) II CONTACT RESISTANCE IO LOAD CONTACT AND DISTRIBUTION LOSSES Von/off Vin- Vout- Figure 11. Circuit Configuration for Remote Sense . Input Undervoltage Lockout Figure 10. Remote On/Off Implementation. To turn the power module on and off, the user must supply a switch (open collector or equivalent) to control the voltage (Von/off) between the On/Off terminal and the VIN(-) terminal (see Figure 10). Logic low is 0V ≤ Von/off ≤ 1.2V. The maximum Ion/off during a logic low is 1mA and the switch should maintain a logic low level while sinking this current. During a logic high, the typical maximum Von/off generated by the module is 5.6V and the maximum allowable leakage current at Von/off = 5.6V is 25μA. If not using the remote On/Off feature: For positive logic, leave the On/Off pin open. For negative logic, short the On/Off pin to VIN(-). Remote Sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections (See Figure 11). The voltage between the remote-sense pins and the output terminals must not exceed the output voltage sense range given in the Feature Specifications table: [VO(+) – VO(–)] – [SENSE(+) – SENSE(–)] ≤ 0.5 V Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will only begin to operate once the input voltage is raised above the undervoltage lockout turn-on threshold, VUV/ON. Once operating, the module will continue to operate until the input voltage is taken below the undervoltage turn-off threshold, VUV/OFF. Overtemperature Protection To provide protection under certain fault conditions, the unit is equipped with a thermal shutdown circuit. The unit will shut down if the thermal reference point, O O Tref, exceeds 135 C (Figure 13, typical) or 120 C (Figure 14, typical), but the thermal shutdown is not intended as a guarantee that the unit will survive temperatures beyond its rating. The module will automatically restart upon cool-down to a safe temperature. Output Overvoltage Protection The output overvoltage protection scheme of the modules has an independent overvoltage loop to prevent single point of failure. This protection feature latches in the event of overvoltage across the output. Cycling the On/Off pin or input voltage resets the latching protection feature. If the auto-restart option (4) is ordered, the module will automatically restart upon an internally programmed time elapsing. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. If the unit is not configured with auto–restart, it will latch off following the overcurrent condition. The module can be restarted by cycling the DC input power for at least LINEAGE POWER 7 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output one second or by toggling the remote On/Off signal for at least one second. If the unit is configured with the auto-restart option (4), it will remain in the hiccup mode as long as the overcurrent condition exists. Once the output current is brought back into its specified range, the unit will operate normally. The average output current during hiccup is 10% IO, max. Output Voltage Programming VO(+) Rtrim-up ON/OFF LOAD VOTRIM Rtrim-down VIN(-) 5.11 × 12.0 × (100 + 4) 511 Rtrim −up = − − 10.22 ΚΩ 1.225 × 4 4 Rtrim −up = 1.16MΩ Trimming allows the output voltage set point to be increased or decreased from the default value. This is accomplished by connecting an external resistor between the TRIM pin and either the VO(+) pin or the VO(-) pin. VIN(+) Where ∆ % = Vdesired − 12.0 × 100 12.0 For example, to trim-up the output voltage of the module by 4% to 12.48V, Rtrim-up is calculated is as follows: ∆% = 4 VO(-) Figure 12. Circuit Configuration to Trim Output Voltage. Connecting an external resistor (Rtrim-down) between the TRIM pin and the VO(-) (or Sense(-)) pin decreases the output voltage set point. To maintain set point accuracy, the trim resistor tolerance should be ±1.0%. The following equation determines the required external resistor value to obtain a percentage output voltage change of Δ% 511 − 10.22 ΚΩ Rtrim − down = ∆ % Where ∆ % = 12.0V − Vdesired × 100 12.0V For example, to trim-down the output voltage of the module by 6% to 11.28V, Rtrim-down is calculated as follows: The voltage between the VO(+) and VO(–) terminals must not exceed the minimum output overvoltage protection value shown in the Feature Specifications table. This limit includes any increase in voltage due to remote-sense compensation and output voltage set-point adjustment trim. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power (maximum rated power = VO,set x IO,max). Thermal Considerations The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The thermal reference points, Tref, used in the specifications for open frame modules is shown in Figure 13. For reliable operation, these temperatures o should not exceed 125 C. ∆% = 6 511 Rtrim−down = − 10.22 ΚΩ 6 AIRFLOW Rtrim − down = 74.9ΚΩ Connecting an external resistor (Rtrim-up) between the TRIM pin and the VO(+) (or Sense (+)) pin increases the output voltage set point. The following equation determines the required external resistor value to obtain a percentage output voltage change of Δ%: 5.11 × 12.0 × (100 + ∆ %) 511 Rtrim −up = − − 10.22 ΚΩ 1.225 × ∆ % ∆% LINEAGE POWER Figure 13. Tref Temperature Measurement Locations for Open Frame Module. The thermal reference point, Tref, used in the specifications for modules with a heat plate is shown in Figure 14. For reliable operation, this temperature O should not exceed 115 C. 8 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output AIRFLOW cold wall, as shown in Figure 19. This capability is achieved by insuring the top side component skyline profile achieves no more than 1mm height difference between the tallest and the shortest power train part that benefits from contact with the gap pad material. The output current derating versus cold wall temperature, when using a gap pad such as Bergquist GP2500S20, is shown in Figure 20. Figure 14. Tref Temperature Measurement Location for Module with Heat plate. Heat Transfer via Convection OUTPUT CURRENT, IO (A) Please refer to the Application Note ‘Thermal Characterization Process For Open-Frame BoardMounted Power Modules’ for a detailed discussion of thermal aspects including maximum device temperatures. Figure 19. Cold Wall Mounting OUTPUT CURRENT, IO (A) Increased airflow over the module enhances the heat transfer via convection. Derating curves showing the maximum output current that can be delivered by each module versus local ambient temperature (TA) for natural convection and up to 2m/s (400 ft./min) forced airflow are shown in Figures 15 - 36. COLD PLATE TEMPERATURE, TC (oC) Figure 20. Derated Output Current versus Cold Wall Temperature with Local Ambient Temperature Around Module at 85C; VIN = 48V. Through-Hole Soldering Information Lead-Free Soldering AMBIENT TEMPERATURE, TA (oC) OUTPUT CURRENT, IO (A) Figure 15. Output Current Derating for the Open Frame Module; Airflow in the Transverse Direction from Vout(-) to Vout(+); VIN =48. The EBVW006A0Bxx RoHS-compliant through-hole products use SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have a RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3°C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210°C. For Pb solder, the recommended pot temperature is 260°C, while the Pb-free solder pot is 270°C max. Paste-in-Hole Soldering AMBIENT TEMPERATURE, TA (oC) Figure 16. Output Current Derating for the Module with Heat plate; Airflow in the Transverse Direction from Vout(-) to Vout(+);VIN =48V. Heat Transfer via Conduction The EBVW006A0Bxx module is compatible with reflow paste-in-hole soldering processes shown in Figures 23-25. Since the EBVW006A0BxxZ module is not packaged per J-STD-033 Rev.A, the module must be baked prior to the paste-in-hole reflow process. EBVW006A0Bxx-HZ modules are not compatible with paste-in-hole reflow soldering. Please contact your Lineage Power Sales Representative for further information. The module can also be used in a sealed environment with cooling via conduction from the module’s top surface through a gap pad material to a LINEAGE POWER 9 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Surface Mount Information MSL Rating The EBVW006A0B-SZ module has a MSL rating of 2a. Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are provided for the EBVW006A0Bxx-SZ modules. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of ≤ 30°C and 60% relative humidity varies according to the MSL rating (see JSTD-033A). The shelf life for dry packed SMT packages is a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40° C, < 90% relative humidity. Pick and Place The EBVW006A0Bxx-S modules use an open frame construction and are designed for a fully automated assembly process. The modules are fitted with a label designed to provide a large surface area for pick and place operations. The label meets all the requirements for surface mount processing, as well as safety standards, and is able to withstand reflow o temperatures of up to 300 C. The label also carries product information such as product code, serial number and the location of manufacture. technology called “Column Pin” (CP) connectors. Figure 22 shows the new CP connector before and after reflow soldering onto the end-board assembly. The CP is constructed from a solid copper pin with an integral solder ball attached, which is composed of tin/lead (Sn/Pb) solder for non-Z codes, or Sn/Ag3/Cu (SAC) solder for –Z codes. Figure 22. Column Pin Connector Before and After Reflow Soldering. The CP connector design is able to compensate for large amounts of planarity and still ensure a reliable SMT solder joint. Typically, the eutectic solder melts at 363°C (Sn/Pb solder) or 217-236°C (SAC solder), wets the land, and subsequently wicks the device connection. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. The following instructions must be observed when SMT soldering these units. Failure to observe these instructions may result in the failure of or cause damage to the modules, and can adversely affect long-term reliability. Tin Lead Soldering Figure 21. Pick and Place Location. Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Even so, these modules have a relatively large mass when compared to conventional SMT components. Variables such as nozzle size, tip style, vacuum pressure and placement speed should be considered to optimize this process. The minimum recommended nozzle diameter for reliable operation is 6mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 9 mm. Oblong or oval nozzles up to 11 x 9 mm may also be used within the space available. Reflow Soldering Information The surface mountable modules in the EBVW006A0Bxx-S family use our newest SMT LINEAGE POWER The EBVW006A0Bxx-S power modules are lead free modules and can be soldered either in a lead-free solder process or in a conventional Tin/Lead (Sn/Pb) process. It is recommended that the customer review data sheets in order to customize the solder reflow profile for each application board assembly. The following instructions must be observed when soldering these units. Failure to observe these instructions may result in the failure of or cause damage to the modules, and can adversely affect long-term reliability. In a conventional Tin/Lead (Sn/Pb) solder process, peak reflow temperatures are limited to less than 235°C. Typically, the eutectic solder melts at 363°C, wets the land, and subsequently wicks the device connection. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. For 10 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Surface Mount Information (continued) Lead Free Soldering The –Z version of the EBVW006A0B modules are lead-free (Pb-free) and RoHS compliant and are both forward and backward compatible in a Pb-free and a SnPb soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Pb-free Reflow Profile Power systems will comply with J-STD-015 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for Per J-STD-020 Rev. C Peak Temp 260°C 250 Reflow Temp (°C) established by accurately measuring the modules CP reliable soldering, the solder reflow profile should be connector temperatures. 300 200 * Min. Time Above 235°C 15 Seconds Cooling Zone 150 Heating Zone 1°C/Second *Time Above 217°C 60 Seconds 100 50 0 Reflow Time (Seconds) Figure 25. Recommended linear reflow profile using Sn/Ag/Cu solder. Post Solder Cleaning and Drying Considerations REFLOW TEMP (°C) Post solder cleaning is usually the final circuit board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AN04-001). REFLOW TIME (S) MAX TEMP SOLDER (°C) Figure 23. Reflow Profile for Tin/Lead (Sn/Pb) process. o Figure 24. Time Limit Curve Above 205 C for Tin/Lead (Sn/Pb) process. both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure 25. LINEAGE POWER 11 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output EMC Considerations The circuit and plots in Figure 26 shows a suggested configuration to meet the conducted emission limits of EN55022 Class B. Figure 26. EMC Considerations. For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028). VIN = 48V, Io = Io,max, L Line LINEAGE POWER VIN = 48V, Io = Io,max, N Line 12 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Mechanical Outline for Through-Hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (unless otherwise indicated) x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.] *Top side label includes Lineage Power name, product designation and date code. LINEAGE POWER 13 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Mechanical Outline for Surface Mount Module (-S Option) Dimensions are in millimeters and [inches]. Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (unless otherwise indicated) x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.] * Top side label includes Lineage Power name, product designation and date code. LINEAGE POWER 14 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Mechanical Outline for Through-Hole Module with Heat Plate (-H Option) Dimensions are in millimeters and [inches]. Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (unless otherwise indicated) x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.] LINEAGE POWER 15 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Recommended Pad Layout Dimensions are in millimeters and [inches]. Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (unless otherwise indicated) x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.] Pin 1 2 3 4 5 6 7 8 Function Vi(+) ON/OFF Vi(-) Vo(-) SENSE(-) TRIM SENSE(+) Vo(+) SMT Recommended Pad Layout (Component Side View) Pin Function 1 Vi(+) 2 ON/OFF 3 Vi(-) 4 Vo(-) 5 SENSE(-) 6 TRIM 7 SENSE(+) 8 Vo(+) NOTES: FOR 0.030” X 0.025” RECTANGULAR PIN, USE 0.050” PLATED THROUGH-HOLE DIAMETER FOR 0.62 DIA” PIN, USE 0.076” PLATED THROUGH-HOLE DIAMETER TH Recommended Pad Layout (Component Side View) LINEAGE POWER 16 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Packaging Details The surface mount versions of the EBVW006A0B (suffix –S) are supplied as standard in the plastic trays shown in Figure 27. Each tray contains a total of 12 power modules. The trays are self-stacking and each shipping box for the EBVW006A0B (suffix –S) surface mount module contains 4 full trays plus one empty hold-down tray giving a total number of 48 power modules. Tray Specification Material Max surface resistivity Color Capacity Min order quantity Antistatic coated PVC 12 10 Ω/sq Clear 12 power modules 48 pcs (1 box of 4 full trays + 1 empty top tray) Figure 27. Surface Mount Packaging Tray. LINEAGE POWER 17 Data Sheet September 14, 2012 EBVW006A0B Series Eighth-Brick Power Modules 36 - 75Vdc Input; 12V/6Adc Output Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Codes Product Codes Input Voltage Output Output Voltage Current On/Off Logic Connector Type EBVW006A0B41Z 48V (36-75Vdc) 12.0V 6A Negative Through-hole EBVW006A0B41-HZ 48V (36-75Vdc) 12.0V 6A Negative Through-hole EBVW006A0B41-SZ 48V (36-75Vdc) 12.0V 6A Negative Surface mount Comcodes 150027602 Table 2. Device Coding Scheme and Options Asia-Pacific Headquarters Tel: +86.021.54279977*808 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-888-LINEAGE(546-3243) (Outside U.S.A.: +1-972-244-WATT(9288)) www.lineagepower.com e-mail: [email protected] Europe, Middle-East and Africa Headquarters Tel: +49.89.878067-280 India Headquarters Tel: +91.80.28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. © 2010 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. Document No: ver. 1.1 PDF name: EBVW006A0B.pdf