EFRP-2300 2U 300W Server Power Supply Features: 2U Form Factor 300W with ATX Outputs High Efficiency 1+1 Redundancy / Load Sharing 0~40℃ Working Temperature World Wide Safety General Specification Input Range: 100 to 240 VAC, +/-10% Power Factor: 0.95 minimum Efficiency: 65% min. Hold Up Time: 20ms minimum, at full load Short Circuit Protection Over Current Protection Over Voltage Protection MTBF >100,000 Hours@25℃ Operating Temperature: 0 to 40 ℃ Operating Humidity: 20 to 90 % EMI/RFI: CE, FCC class B Safety: UL, TUV, CCC, CB, BSMI Input and Output Characteristics Input Output Voltage Frequency Current 100~240 47~63Hz 6~3A VAC Load +3.3V +5V +12V -12V -5V +5VSB Max.Load 25A 30A 18A 0.8A 0.3A 2A Min.Load 2A 3A 2A 0A 0A 0A 1. The +5 & +3.3 Volt combine total output current shall not exceed 170W 2. The +5, +3.3 , and +12 Volt combine total output shall not exceed 280W Ripple and Noise Output +3.3V +5V +12V -12V -5V 5Vsb Load Regulation ±5% ± 5% ± 5% ± 10% ± 10% ± 5% Line Regulation ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% Ripple & Noise 60mV 60mV 120mV 120mV 100mV 70mV Mechanical Outline Dimension: 86x84x290(mm) Outline Drawing ©ETASIS Electronic Corporation. All rights reserved. ETASIS Electronics Corporation reserves the right to make changes to their products, specification, or to discontinue any product and its service at anytime without notice. The information and specification from ETASIS is believed to be accurate and reliable. However, ETASIS assumes no responsibility for any business loss due to specification changes. ETASIS products are not designed to be used in system deemed to be critical, or in any system wherein failure or malfunction could result in injury or death.