Omron D2F-FL-A1 Incorporating a snapping mechanism made with two highly precise split springs that ensures long durability Datasheet

D2F
Ultra Subminiature Basic Switch
Ultra Subminiature Basic
Switch with plenty of
terminal variations
● Incorporating a snapping mechanism made with
two highly precise split springs that ensures long
D
2
F
durability.
● Using insertion molded terminals
that prevents flux penetration.
● In addition to self-clinching PCB, left-angled,
right-angled terminals,
2 types of soldering terminals are available.
RoHS Compliant
Model Number Legend
1 @
2 @
3 @
4
D2F - @
1. Ratings
None : 125 VAC 3A
125 VAC 1A (Low operating force)
01 : 30 VDC 0.1A
4. Terminals
None : PCB terminals (Straight)
-T : Self-clinching PCB terminals
-A : PCB terminals (Right-angled)
-A1 : PCB terminals (Left-angled)
-D3 : Solder terminals
-D : Compact solder terminals
2. Maximum Operating Force (OF)
None : 1.47 N {150 gf}
F : 0.74 N {75 gf}
Note. The given values are for pin plunger models only.
3. Actuator
None : Pin plunger
L : Hinge lever
L2 : Hinge Roller Lever
L3 : Simulated roller lever (R1.3)
L30 : Simulated roller lever (R2.5)
List of Models
Ratings
Maximum Operating Force (OF)
Actuator
Pin plunger
Hinge lever
Terminals
3A
1A
General Purpose
1.47 N {150 gf}
Low Operating Force
0.74 N {75 gf}
0.1 A
General Purpose
1.47 N {150 gf}
Low Operating Force
0.74 N {75 gf}
PCB terminals (Standard)
D2F
D2F-F
D2F-01
D2F-01F
Self-clinching PCB terminals
D2F-T
D2F-F-T
D2F-01-T
D2F-01F-T
PCB terminals (Right-angled)
D2F-A
D2F-F-A
D2F-01-A
D2F-01F-A
PCB terminals (Left-angled)
D2F-A1
D2F-F-A1
D2F-01-A1
D2F-01F-A1
Solder terminals
D2F-D3
D2F-F-D3
D2F-01-D3
D2F-01F-D3
Compact solder terminals
D2F-D
D2F-F-D
D2F-01-D
D2F-01F-D
PCB terminals (Standard)
D2F-L
D2F-FL
D2F-01L
D2F-01FL
Self-clinching PCB terminals
D2F-L-T
D2F-FL-T
D2F-01L-T
D2F-01FL-T
PCB terminals (Right-angled)
D2F-L-A
D2F-FL-A
D2F-01L-A
D2F-01FL-A
PCB terminals (Left-angled)
D2F-L-A1
D2F-FL-A1
D2F-01L-A1
D2F-01FL-A1
Solder terminals
D2F-L-D3
D2F-FL-D3
D2F-01L-D3
D2F-01FL-D3
Compact solder terminals
D2F-L-D
D2F-FL-D
D2F-01L-D
D2F-01FL-D
1
D2F
Ultra Subminiature Basic Switch
Ratings
Maximum Operating Force (OF)
Actuator
Terminals
Hinge roller
lever
D
2
F
Simulated roller
lever (R1.3)
Simulated roller
lever (R2.5)
3A
1A
General Purpose
1.47 N {150 gf}
Low Operating Force
0.74 N {75 gf}
0.1 A
General Purpose
1.47 N {150 gf}
PCB terminals (Standard)
D2F-L2
D2F-FL2
D2F-01L2
D2F-01FL2
Self-clinching PCB terminals
D2F-L2-T
D2F-FL2-T
D2F-01L2-T
D2F-01FL2-T
PCB terminals (Right-angled)
D2F-L2-A
D2F-FL2-A
D2F-01L2-A
D2F-01FL2-A
PCB terminals (Left-angled)
D2F-L2-A1
D2F-FL2-A1
D2F-01L2-A1
D2F-01FL2-A1
Solder terminals
D2F-L2-D3
D2F-FL2-D3
D2F-01L2-D3
D2F-01FL2-D3
Compact solder terminals
D2F-L2-D
D2F-FL2-D
D2F-01L2-D
D2F-01FL2-D
PCB terminals (Standard)
D2F-L3
D2F-FL3
D2F-01L3
D2F-01FL3
Self-clinching PCB terminals
D2F-L3-T
D2F-FL3-T
D2F-01L3-T
D2F-01FL3-T
PCB terminals (Right-angled)
D2F-L3-A
D2F-FL3-A
D2F-01L3-A
D2F-01FL3-A
PCB terminals (Left-angled)
D2F-L3-A1
D2F-FL3-A1
D2F-01L3-A1
D2F-01FL3-A1
Solder terminals
D2F-L3-D3
D2F-FL3-D3
D2F-01L3-D3
D2F-01FL3-D3
Compact solder terminals
D2F-L3-D
D2F-FL3-D
D2F-01L3-D
D2F-01FL3-D
PCB terminals (Standard)
D2F-L30
D2F-FL30
D2F-01L30
D2F-01FL30
Self-clinching PCB terminals
D2F-L30-T
D2F-FL30-T
D2F-01L30-T
D2F-01FL30-T
PCB terminals (Right-angled)
D2F-L30-A
D2F-FL30-A
D2F-01L30-A
D2F-01FL30-A
PCB terminals (Left-angled)
D2F-L30-A1
D2F-FL30-A1
D2F-01L30-A1
D2F-01FL30-A1
Solder terminals
D2F-L30-D3
D2F-FL30-D3
D2F-01L30-D3
D2F-01FL30-D3
Compact solder terminals
D2F-L30-D
D2F-FL30-D
D2F-01L30-D
D2F-01FL30-D
Contact Form
Contact Specifications
●SPDT
Item
Model
D2F models
Specifications
Contact
Material
Gap (standard value)
Minimum applicable load (see note) *
COM
NO NC
*
Model
Maximum Operating
Force (OF)
Rated voltage
D2F models
1.47N (General-purpose)
D2F-01 models
0.74N (Low Operating Force)
1.47N (General-purpose)
0.74N (Low Operating Force)
Resistive load
125 VAC
3A
1A
-
30 VDC
2A
0.5 A
0.1 A
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Approved Safety Standard
The items shown in the "List of Models" above are not standard approved models.
Consult your OMRON sales representative for specific models with standard approvals.
UL (UL1054) /CSA (CSA C22.2 No.55)
Rated voltage
Model
D2F (General-purpose)
D2F (Low operating force)
125 VAC
3A
1A
-
30 VDC
2A
0.5 A
0.1 A
D2F-01
Characteristics
Item
Model
Permissible operating speed
Mechanical
Contact resistance (initial value)
D2F-F models
D2F models
Pin plunger models: 1 mm to 500 mm/s,
Lever models: 5 mm to 500 mm/s
Pin plunger models: 200 operations/min,
Lever models: 100 operations/min
Electrical
Insulation resistance
2
D2F-01 models
30 operations/min
100 MΩ min. (at 500 VDC with insulation tester)
100 mΩ max.
D2F-01 models
Crossbar
Silver alloy
Gold alloy
0.25 mm
100 mA at 5 VDC
1 mA at 5 VDC
Please refer to "Using Micro Loads" in "Precautions" for more information
on the minimum applicable load.
Ratings
Permissible
operating
frequency
Low Operating Force
0.74 N {75 gf}
50 mΩ max.
30 mΩ max.
D2F
Ultra Subminiature Basic Switch
Item
Model
Dielectric
strength
Vibration
resistance * 1
D2F-01 models
600 VAC 50/60 Hz for 1min
1,500 VAC 50/60 Hz for 1min
Between each terminal and
non-current-carrying metal parts
1,500 VAC 50/60 Hz for 1min
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s2 {approx. 100G} max.
300 m/s2 {approx. 30G} max.
Malfunction * 1
Mechanical
Durability * 2
D2F models
Between current-carrying metal
parts and ground
Durability
Shock
resistance
D2F-F models
Between terminals of the same
polarity
1,000,000 operations min. (60 operations/min)
100,000 operations min.
(30 operations/min)
Electrical
D
2
F
30,000 operations min.
(30 operations/min)
Degree of protection
IEC IP40
-25°C to +85°C (at ambient humidity 60% max.)
(with no icing or condensation)
Ambient operating temperature
Ambient operating humidity
85% max. (for +5°C to +35°C)
Weight
Approx. 0.5 g (pin plunger models)
Note. The data given above are initial values.
*1. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever.
Close or open circuit of the contact is 1ms max.
*2. For testing conditions, consult your OMRON sales representative.
Terminals/Appearances
(Unit: mm)
●PCB terminals (Straight)
●Self-clinching PCB terminals
<PCB Mounting Dimensions (Reference)>
5.8±0.15
3-1.2 dia. holes
3.15
6.5±0.1
5.08
5.08
12.8±0.15
1.5
1.5
3.5
3.4
3.15
0.4
0.9
6.5±0.1
5.08
5.8±0.15
5.08
5.08±0.1
12.8±0.15
1.6±0.15
5.8±0.15
12.8±0.15
●PCB terminals (Right-angled)
1.5
0.9 0.4±0.05
1.25±0.15
●PCB terminals (Left-angled)
1.5
1.5
2.6±0.2
3.15
6.5±0.1
5.8±0.15
0.9
3.1±0.2
5.08
5.08
12.8±0.15
●Solder terminals
2.6±0.2
3.15
0.4
1.5
1.5
3.5
3.15
6.5±0.1
0.9
0.4
5.8±0.15
3.1±0.2
●Compact solder terminals
2
0.5
6.5±0.1
5.08
5.08
12.8±0.15
3.15
1.2
2.2
0.4
5.8±0.15
5.08
5.08
12.8±0.15
3−0.8 dia. holes
6.5±0.1
5.08
5.08
1.6
2.4
0.4
5.8±0.15
12.8±0.15
Mounting Holes (Unit: mm)
2-2 dia. mounting holes
6.5±0.15
3
D2F
Ultra Subminiature Basic Switch
Dimensions (Unit: mm) /Operating Characteristics
The following illustrations and drawings are for D2F models with PCB terminals (straight). Self-clinching, solder, compact solder, and right-angled, left angled terminals
are omitted from the following drawings. Refer to the previous page for these terminals.
When ordering, replace @ with the code for the terminal that you need. See the "List of Models" for available combinations of models.
●Pin Plunger Models
D2F@
D2F-01@
D2F-F@
D2F-01F@
1.2
12.7
dia.
2.2+0.12
0
2+0.12
dia. holes
0
A
5
D
2
F
5.7
2.9
PT
5.2
Operating
Characteristics
Operating Force
Releasing Force
OP
2+0.12
0
Model D2F-@
D2F-01@
OF Max. 1.47 N {150 gf} 0.74 N {75 gf}
RF Min. 0.20 N {20 gf} 0.05 N {5 gf}
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
0.4
D2F-F@
D2F-01F@
OP
0.5 mm
0.25 mm
0.12 mm
0.5 mm
0.25 mm
0.12 mm
5.5±0.3 mm
5.8±0.15
●Hinge Lever Models
D2F-L@
D2F-01L@
D2F-FL@
D2F-01FL@
12.8
(10.8)
Operating
Characteristics
A
t=0.3 *
3
Operating Force
Releasing Force
FP
Model D2F-L@
D2F-01L@
OF Max.
RF Min.
Overtravel
OT Min.
Movement Differential MD Max.
OP
Free Position
Operating Position
FP Max.
OP
D2F-FL@
D2F-01FL@
0.78 N {80 gf}
0.05 N {5 gf}
0.25 N {25 gf}
0.02 N {2 gf}
0.55 mm
0.5 mm
0.55 mm
0.5 mm
10 mm
6.8±1.5 mm
* Stainless-steel lever
●Simulated Roller Lever Models (R1.3)
D2F-L3@
12.7
D2F-01L3@
(7.5)
D2F-FL3@
10
D2F-01FL3@
Model
Operating
Characteristics
A
t=0.3 *
2.1
R1.3
3
Operating Force
Releasing Force
OF Max.
RF Min.
Overtravel
OT Min.
Movement Differential MD Max.
FP
OP
Free Position
Operating Position
FP Max.
OP
D2F-L3@
D2F-01L3@
D2F-FL3@
D2F-01FL3@
0.78 N {80 gf}
0.05 N {5 gf}
0.39 N {40 gf}
0.02 N {2 gf}
0.5 mm
0.45 mm
0.5 mm
0.45 mm
13 mm
8.5±1.2 mm
* Stainless-steel lever
●Simulated Roller Lever Models (R2.5)
D2F-L30@
D2F-01L30@
12.7
D2F-FL30@
D2F-01FL30@
3.3
t=0.3 *
R2.5 A
3
OP
FP
Operating
Characteristics
Operating Force
Releasing Force
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
4
OF Max.
RF Min.
Overtravel
OT Min.
Movement Differential MD Max.
Free Position
Operating Position
* Stainless-steel lever
Model D2F-L30@
D2F-01L30@
FP Max.
OP
D2F-FL30@
D2F-01FL30@
0.54 N {55 gf}
0.04 N {4 gf}
0.3 N {31 gf}
0.02 N {2 gf}
0.5 mm
0.5 mm
0.5 mm
0.5 mm
12.6 mm
9.5±1.0 mm
D2F
Ultra Subminiature Basic Switch
●Hinge Roller Lever Models
D2F-L2@
D2F-01L2@
D2F-FL2@
D2F-01FL2@
12.8
4
(10)
A
4.8 dia.×2.8 *2
(4.6)
Operating Force
Releasing Force
OF Max.
RF Min.
Overtravel
OT Min.
Movement Differential MD Max.
t=0.3 *1
4
Model D2F-L2@
D2F-01L2@
Operating
Characteristics
FP
Free Position
Operating Position
OP
D2F-FL2@
D2F-01FL2@
0.78 N {80 gf}
0.05 N {5 gf}
0.39 N {40 gf}
0.02 N {2 gf}
0.55 mm
0.5 mm
0.55 mm
0.5 mm
FP Max.
OP
16.5 mm
13±2 mm
D
2
F
*1. Stainless-steel lever
*2. Polyacetal resin roller
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
Precautions
★Please refer to "Basic Switches Common Precautions" for correct use.
Cautions
• Terminal connection
When soldering, make sure that the temperature of the
soldering iron tip is not higher than 300°C, and complete the
soldering within 3 seconds. Do not apply any external force for
1 minute after soldering. Soldering at an excessively high
temperature or soldering for more than 3 seconds may
deteriorate the characteristics of the Switch.
• Connecting to PCB terminal Boards
When using automatic soldering baths, we recommend
soldering at 260°C ±5°C within 5 seconds. Make sure that the
liquid surface of the solder does not flow over the edge of the
board.
When soldering terminals manually, perform soldering within 3
seconds at iron tip temperature not higher than 350°C. Do not
apply any external force for at least 1 minute after soldering.
When applying solder, keep the solder away from the case of
the Switch and do not allow solder or flux to flow into the case.
●Mounting
Use M2 mounting screws with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of
0.08 to 0.1 N·m {0.8 to 1 kgf·cm}.
●Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the following operating range, if inrush
current occurs when the contact is opened or closed, it may
increase the contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary. The
minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ60).
(JIS C5003)
The equation, λ60=0.5×10-6/operation, indicates that the
1
estimated malfunction rate is less than
operations
2,000,000
with a reliability level of 60%.
Voltage (V)
●Soldering
Correct Use
30
16.6 mA 100 mA
0.16 mA
24
Operating range
for micro load
models
D2F-01
Operating
range for
general-load
models
D2F
12
5
1 mA
0
0.1
1
10
100
1,000
Current (mA)
5
D2F
Ultra Subminiature Basic Switch
D
2
F
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
6
Contact: www.omron.com/ecb
Cat. No. B036-E1-09
0812(0207)(O)
Similar pages