TSC ARS35 35.0 amps. high current plastic silicon rectifier Datasheet

ARS35 / AR35
35.0 AMPS. High Current Plastic Silicon Rectifiers
Voltage Range
50 to 1000 Volts
Current
35.0 Amperes
ARS
Features
AR
Plastic material used carries Underwriters
Laboratory Classification 94V-O
Low cost construction utilizing void-free molded
plastic technique
Low cost
Diffused junction
Low leakage
High surge capability
High temperature soldering guaranteed:
260oC for 10 seconds
Mechanical Data
Case: Molded plastic case
Terminals: Plated terminals, solderable per MILSTD-202, Method 208
Polarity: Color ring denotes cathode end
Weight: 0.07 ounce, 1.8 grams
Mounting position: Any
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
ARS
Type Number
Maximum Recurrent Peak Revere Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@Tc = 150℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method ) at TJ=150oC
Maximum Instantaneous Forward Voltage
@ 35A
Maximum DC Reverse Current @ Tc=25℃
at Rated DC Blocking Voltage @ Tc=100℃
Typical Reverse Recovery Time (Note 2)
Typical Junction Capacitance ( Note 1 )
TJ=25oC
Typical Thermal Resistance ( Note 3 )
AR
35A
ARS
35B
AR
35B
ARS
35D
AR
35D
ARS
35G
AR
35G
ARS
35J
AR
35J
ARS
35K
AR
35K
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800 1000
560 700
800 1000
Symbol 35A
VRRM
VRMS
VDC
ARS
35M
AR
35M
Units
V
V
V
I(AV)
35
A
IFSM
500
A
VF
1.0
V
Trr
5.0
250
3.0
uA
uA
uS
Cj
300
pF
RθJC
1.0
℃/W
℃
IR
TJ, TSTG
-50 to +175
Notes: 1. Measured at 1 MHz and Applied Reverse Voltage of 4.0 V D.C.
2. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
3. Thermal Resistance from Junction to Case, Singe Side Cooled.
Operating and Storage Temperature Range
- 502 -
RATINGS AND CHARACTERISTIC CURVES (ARS35 THRU AR35)
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
FIG.2- MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
1000
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD CURRENT. (A)
35
SINGLE PHASE
HALF WAVE 60Hz
RESISTIVE OR
INDUCTIVE LOAD
30
25
20
15
10
5
0
125
8.3ms Single Half Sine Wave
JEDEC Method
500
100
50
135
145
155
165
1
175
2
CASE TEMPERATURE. ( C)
20
10
5
o
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL FORWARD CHARACTERISTICS
FIG.4- TYPICAL REVERSE CHARACTERISTICS
1000
100
60
INSTANTANEOUS REVERSE CURRENT. ( A)
100
10
1
Tj=100 0C
20
10
6
4
2
1
Tj=25 0C
0.6
0.4
0
Tj=25 C
PULSE WIDTH-300 S
2% DUTY CYCLE
0.1
0.6
1.0
1.4
1.8
2.2
0.2
0.1
2.6
FORWARD VOLTAGE. (V)
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
FIG.5- TYPICAL JUNCTION CAPACITANCE
1000
JUNCTION CAPACITANCE.(pF)
INSTANTANEOUS FORWARD CURRENT. (A)
40
500
Tj=25 0C
100
50
1
2
5
10
REVERSE VOLTAGE. (V)
- 503 -
20
50
100
Similar pages