Omron D2FD-01L0-1T Dust proof ultra subminiature basic switch Datasheet

D2FD
Dust Proof Ultra Subminiature Basic Switch
Ultra subminiature and dust
proof
• Sealing by using rubber packing means the switch
can be used in dust-proof environments (IEC IP6X).
• Switch rating of 2 A at 125 VAC possible with a
single-leaf movable spring. Models for micro loads
are also available.
• Solder and PCB terminals are available.
RoHS Compliant
Model Number Legend
D2FD - @ @ - 1 @
1
2
3
1. Rating
3. Terminals
2 : 2 A at 125 VAC / 30 VDC
H : Solder terminals
01 : 0.1 A at 125 VAC / 30 VDC
T : PCB terminals
2. Actuater
L0 : Pin plunger
L1 : Hinge lever
L30 : Simulated roller lever
List of Models
Ratings
Actuator
Terminals
2A
0.1 A
Pin plunger
Solder terminals
D2FD-2L0-1H
D2FD-01L0-1H
PCB terminals
D2FD-2L0-1T
D2FD-01L0-1T
Solder terminals
D2FD-2L1-1H
D2FD-01L1-1H
PCB terminals
D2FD-2L1-1T
D2FD-01L1-1T
Solder terminals
D2FD-2L30-1H
D2FD-01L30-1H
PCB terminals
D2FD-2L30-1T
D2FD-01L30-1T
Hinge lever
Simulated roller
lever (R2.5)
Contact Form
● SPDT
COM
NO NC
1
D2FD
Dust Proof Ultra Subminiature Basic Switch
Contact Specifications
Item
Model
D2FD-2 models
D2FD-01 models
Specification
Contact
Crossbar
Material
Silver alloy
Gold alloy
Gap (standard value)
0.25 mm
Minimum applicable load (see note)
100 mA at 5 VDC
1 mA at 5 VDC
Note: For more information on the minimum applicable load, refer to Using Micro Loads.
Ratings
D2FD-2 models
Model
Rated voltage
D2FD-01 models
Resistive load
125 VAC
2A
0.1 A
30 VDC
2A
0.1 A
Note: The rating values apply under the following test conditions.
1. Ambient temperature: 20 ± 2°C
2. Ambient humidity: 65 ± 5%
3. Operating frequency: 20 operations/min
Characteristics
Item
Model
D2FD-2 models
Operating speed
D2FD-01 models
1 mm to 500 mm/s
Mechanical
Operating frequency
120 operations/min max.
Electrical
20 operations/min max
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance (initial value)
30 mΩ max.
100 mΩ max.
600 VAC 50/60 Hz 1 min between terminals of same polarity
Dielectric strength (see note 2)
1,500 VAC 50/60 Hz 1 min between current carrying metal parts and ground
1,500 VAC 50/60 Hz 1 min between each terminal and non-current carrying metal part
Vibration resistance (see note 3) Malfunction
Shock resistance (see note 3)
10 to 55 Hz, 1.5 mm double amplitude
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2 max.
Mechanical
Durability (see note 4)
Electrical
300,000 operations min. (at 60 ops./min.)
30,000 operations min. (at 20 ops./min.)
Degree of protection
100,000 operations min. (at 20 ops./min.)
IP6X
−20 to +70°C (at 60%RH max.) (with no icing)
Ambient operating temperature
Ambient operation humidity
85%RH max. (for +5 to +35°C)
Weight
Approx. 0.7 g (pin plunger, PCB terminal models)
Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values apply at the total travel
position. Contact opening or closing time is within 1 ms.
4. Consult your OMRON sales representative for testing conditions.
Terminals (Unit: mm)
● Solder Terminals
2.5±0.1
● PCB Terminals
PCB Mounting Dimensions
(Reference)
Three, 1.2±0.05 Dia.
+0.1
2.4 –0.05 Dia.
5±0.15
Two,1.2
+0.12
0
Dia.
1.1±0.12
2.4 +0.1
–0.05
1.7
1.5
1.6
5.5
1.5±0.1
5.7
2
4
0.5
0.4
4.8±0.1
5.08±0.15
5.08±0.15
12.8±0.15
4.4
6
Mounting Holes (Unit: mm)
● Solder Terminals
Two, M2.3
4.8±0.1
2
1.5±0.12
0.4
Three, R0.8
1.2
2.2
3.15
6.5±0.1
5.08±0.15
5.08±0.15
12.8±0.15
1.25±0.12
0.9
4.4
6
5.08±0.1
5.08±0.1
D2FD
Dust Proof Ultra Subminiature Basic Switch
Dimensions (Unit: mm) / Operating Characteristics
The following illustrations and drawings are for solder terminal models. PCB terminal models are omitted from the drawings. Refer to Terminals for these terminals.
When ordering, replace @ with the code for the rating that you need. For the combination of models, refer to List of Models.
● Pin Plunger Models
D2FD-@L0-1H
D2FD-@L0-1T
A
+0.1
2.4 –0.05
● Hinge Lever Models
D2FD-@L1-1H
D2FD-@L1-1T
2.5±0.1
PT
4.35
1.2 Dia.
+0.1
2.4 –0.05 Dia.
6.5±0.15
OP
Model
OF max.
RF min.
2.00 N {204 gf}
0.25 N {25 gf}
PT max.
OT mix.
MD max.
0.6 mm
0.25 mm
0.12 mm
OP (-1H)
OP (-1T)
7.0 ± 0.2 mm
7.0 ± 0.3 mm
5.25
t = 0.3 Stainless-steel lever
A
3
FP
OP
6.5±0.15
● Simulated Roller Lever Models (R2.5)
D2FD-@L30-1H
D2FD-@L30-1T
4.2
Model
3
R2.5
t = 0.3 Stainless-steel lever
FP
OP
6.5±0.15
D2FD-@L1-1H
D2FD-@L1-1T
OF max.
RF min.
0.65 N {66 gf}
0.05 N {5 gf}
OT mix.
MD max.
0.5 mm
0.5 mm
FP max.
OP (-1H)
OP (-1T)
11.3 mm
8.3 ± 1.0 mm
8.3 ± 1.2 mm
Model
A
D2FD-@L0-1H
D2FD-@L0-1T
D2FD-@L30-1H
D2FD-@L30-1T
OF max.
RF min.
0.65 N {66 gf}
0.05 N {5 gf}
OT mix.
MD max.
0.5 mm
0.5 mm
FP max.
OP (-1H)
OP (-1T)
14.3 mm
11.3 ± 1.0 mm
11.3 ± 1.2 mm
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The operating characteristics are for operation in the A direction ( ).
3
D2FD
Dust Proof Ultra Subminiature Basic Switch
Precautions
Refer to General Information.
Cautions
● Degree of Protection
● Operating Body
• Do not use the Switch under the environment where it is
exposed to water.
The degree of protection is IP6X and the protection against
water is not defined.
• Prevent the Switch from coming into contact with oil and
chemicals. Otherwise, damage to or deterioration of Switch
• Use an operating body with low frictional resistance and of a
shape that will not interfere with the sealing rubber, otherwise
the plunger may be damaged or the sealing may deteriorate.
With the pin plunger models, set the Switch so that the plunger can
be pushed in from directly above. Since the plunger is covered with
a rubber cap, applying a force from lateral directions may cause
● Terminal Connection
• When soldering a lead wire to the terminal, first insert the lead
wire conductor into the terminal hole and then perform soldering. Make sure that the capacity of the soldering iron is 30 W
maximum and that the temperature of the soldering iron tip is
approximately 300°C. (350°C maximum.) Complete the soldering within 3 s.
Using a switch with improper soldering may result in abnormal
heating, possibly resulting in burn.
Applying a soldering iron for more than 3 s or using one that is
rated at more than 30 W may deteriorate the switch characteristics.
When using automatic soldering baths, we recommend soldering at 260 ± 5°C within 5 seconds. Make sure that the liquid
surface of the solder does not flow over the edge of the board.
Correct Use
● Mounting
• Turn OFF the power supply before mounting or removing the
Switch, wiring, or performing maintenance or inspection. Failure to do so may result in electric shock or burning.
• Use M2.3 mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque
of 0.20 to 0.29 N·m {2.0 to 2.9 kgf·cm}. Exceeding the specified
torque may result in deterioration of the sealing or damage.
Mount the Switch onto a flat surface. Mounting on an uneven
surface may cause deformation of the Switch, resulting in
faulty operation or damage.
damage to the plunger or reduction in the sealing capability.
Correct
Incorrect
Incorrect
● Handing
• Do not handle the Switch in a way that may cause damage to the
sealing rubber.
• When handling the Switch, ensure that uneven pressure or, as
shown in the following diagram, pressure in a direction other than
the operating direction is not applied to the Actuator, otherwise
the Actuator or Switch may be damaged, or durability may be
decreased.
Incorrect
Incorrect
Incorrect
Incorrect
● Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may
increase contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60). The equation, λ 60 = 0.5 × 10-6/operations
indicates that the estimated malfunction rate is less than 1/
2,000,000 operations with a reliability level of 60%.
Voltage (V)
materials may result.
• Do not use the Switch in areas where it is exposed to silicon
adhesives, oil, or grease, otherwise faulty contact may result
due to the generation of silicon oxide.
• The environment-resistant performance of the switch differs
depending on operating loads, ambient atmospheres, and
installation conditions, etc. Please perform an operating test of
the switch in advance under actual usage conditions.
30
0.16 mA
16.6 mA 100 mA
24
Operating range
for micro load
models D2FD-01
Operating
range for
general-load
models
D2FD-2
12
Inoperable
range
5
1 mA
0
0.1
1
10
100
1,000
Current (mA)
4
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control
systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or
equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product
provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation Electronic and Mechanical Components Company
Authorized Distributor:
Contact: www.omron.com/ecb
OMRON ELECTRONIC COMPONENTS EUROPE B.V. OMRON ELECTRONIC COMPONENTS TRADING
Wegalaan 57, 2132 JD Hoofddorp,THE NETHER LANDS (SHANGHAI) LTD. SHANGHAI OFFICE
Tel: (31)23-568-1200/Fax: 31-23-568-1212
27F Xin Mei Union Square, 999 Pudong South Road,
Pudong New Area, Shanghai, CHINA 200120
OMRON ELECTRONIC COMPONENTS LLC
Tel: (86)21-6859-5919/Fax: 86-21-6859-5911
55 East Commerce Drive, Suite B, IL 60173 U.S.A.
Tel: (1)847-882-2288/Fax: 1-847-882-2192
OMRON ELECTRONIC COMPONENTS CO., LTD.
14F, Daegong Bldg. #823-21, Yeoksam-dong,
OMRON ELECTRONIC COMPONENTS PTE LTD.
Gangnam-gu, Seoul, Korea, 135-080
438A Alexandra Road #05-05/08 Alexandra
Tel:(82)2-567-5020/Fax:(82)2-567-5804
Technopark Singapore 119967
TEL:(65)6376-3200/FAX:(65)6376-3211
© OMRON Corporation 2012 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. B119-E1-01
0312
Similar pages