Universal PLC Interface with PDT Relay – now also with spring cage connection system! The PLC-R...21 relay series, that can be used universally, consisting of 6.2 mm base terminal blocks and pluggable miniature relays with PDT contact, has now been included in the range with spring cage connections. The wiring, diagonally from above, is particularly convenient during assembly. The costintensive wiring is reduced yet again when the plug-in bridges are implemented. A side-effect is a cut in the likelihood of faulty wiring and time-consuming troubleshooting. PDT = great flexibility The universal PDT series, PLC-RSP...21, is used whenever an application demands great flexibility. It can be used – as an input or output interface or – in N/C, N/O or PDT applications. Advantage: fewer ordering and warehousing items. In the standard version, the PLC interfaces are supplied equipped complete with relay (or miniature optical coupler with electronic N/O function). Input voltages of 12V to 230V PLC-RSP...21 on the coil side is, like the proven screw clamp versions, available in all conventional industrial voltages from 12 V to 230 V. A further advantage is the ready-integrated input circuit. It consists of a status display, damping function, and polarity reversal protection function, and guarantees a clear display of the operational status, EMC interference suppression of the coil, and prevents destruction of the same, should the polarity be accidentally reversed. “…6” 8 (IEC) [mm2 ] rigid solid flexible stranded AWG Connection data 0.2-2.5 0.2-1.5 24-14 * The electrical data are determined by the relay. A2 11 A1 14 I U [A] [V] * * 12 94 Robust miniature relay The heart of the PDT relay series is a robust 6,2 80 miniature relay from the latest generation, equipped with features that you will search for in vain in most standard pluggable relays: – Operational safety with IP67-protected mechanics, – Environmentally friendly, cadmium-free power contact material for loads up to 250 V AC/6 A, – As an alternative with a gold layer for smaller capacities (mA), – Reliable isolation in acc. with DIN VDE 0106-101, – 4kVrms potential separation between coil and contact. The relay is securely fastened using an engagement lever. Should it become worn, it can be disengaged, and – without disconnecting the wiring – replaced quickly contact 11 on the contact side, the continuous plug-in and economically. bridges which can be cut to length as desired, or the 2position jumper plugs guarantee with one “click” quick, Plug-in bridges save wiring economical and fault-free wiring, whilst providing A big plus for cunning wiring professionals is the convenient plug-in bridge system FBST. Whether there utmost clarity. This makes complicated, time-consuming is an A1/A2 ground on the coil side, or group feed-in at loop bridges a thing of the past! Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 1 of 14 Universal PLC Interface with PDT Relay – now also with spring cage connection system! Input voltage UN 1 ) Description PLC interface, consisting of base terminal block PLC-BSP…/21 and pluggable miniature relay (see catalog part 6, page 32), for mounting on 3 PLC interface, consisting of base terminal block PLC-BSP…/21 and pluggable miniature relay (see catalog part 6, page 32), for mounting on 3 Type Order No. Pcs./ Pkt. 24 V DC 24 V AC/DC 120 V AC/220 V DC 230 V AC/220 V DC 2) equipped with universal multi-layer contact relay PLC-RSP- 24DC/21AU PLC-RSP- 24UC/21AU PLC-RSP-120UC/21AU PLC-RSP-230UC/21AU 29 66 54 0 29 66 55 3 29 66 58 2 29 66 64 7 10 10 10 10 24 V DC 24 V AC/DC 120 V AC/220 V DC 230 V AC/220 V DC 2) equipped with power contact relay PLC-RSP- 24DC/21 PLC-RSP- 24UC/21 PLC-RSP-120UC/21 PLC-RSP-230UC/21 29 66 47 2 29 66 48 5 29 66 52 4 29 66 53 7 10 10 10 10 Technical data 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 250 V AC Min. switching capacity General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Mechanical service life Standards/regulations Installation position/assembly Type of connection PLC-R…/21 single contact, 1 PDT AgSnO 250 V AC/DC 2) 12 V AC/DC 6A on request 10 mA 140 W 20 W 18 W 23 W 40 W 1500 VA 120 mW PLC-R…/21AU single contact, 1 PDT AgSnO + 5 µ Au 3) 30 V AC/36 V DC 100 mV 50 mA 50 mA 1 mA 1.2 W – – – – – 100 µW 4 kV, 50 Hz, 1 min. – 20 °C to + 55 °C (24 V types to + 60 °C) 100 % ED V0 in acc. with UL 94 107 cycles IEC 664/IEC 664 A/DIN VDE 0110, contamination class 3, Surge voltage category III, DIN VDE 0160 (in relev. parts), IEC 255/DIN VDE 0435 (in relev. parts), DIN VDE 0106-101: 1986-11, increased insulation I/O 4) as desired, in rows with zero spacing spring cage connection 1 ) Further input voltages available on request. Notes: 2 ) For voltages higher than 250 V (e.g. L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 3 ) If the maximum values indicated are exceeded, the gold layer is destroyed. The values of the AgSnO contact are then valid. 4 ) For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. http://www.phoenixcontact.com Output data Contact type Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Max. power rating, ohmic load: 120 V AC/ 230 V AC/ 110 V DC 220 V DC 2) see diagram, catalog part 6, page 25 9 mA 11/8.5 mA 3.5/3 mA 3 mA 5 ms 6 ms 6 ms 7 ms 8 ms 15 ms 15 ms 15 ms operation indicator, polarity protection diode, damping diode operation indicator, bridge rectifier TNR: 5087390-00 24 V DC 24, 120, 230 V AC/DC 24 V AC/DC 30.10.98 Permissible input voltage range Typ. input current at UN Typ. response time at UN Typ. release time at UN Input circuit 24 V DC Marking systems and mounting material, see catalog part 3/4. The rated cross section (see catalog part 6, page 151) refers to untreated conductors without ferrules. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. Due to the input circuit integrated in the base terminal block, a 60 V relay, REL-MR-60DC/... is used with the 120 V and 230 V modules. (see catalog part 6, page 32) The PLC-ATP separating plate (see catalog part 6, page 34) must always be installed at the beginning and end of a PLC terminal strip. PHOENIX CONTACT page 2 of 14 PHOENIX CONTACT Input data Nominal input voltage UN Universal PLC Interface with Optical Coupler – now also with spring cage connection system! The PLC-O.. optical coupler series, that can be used universally, consisting of pluggable miniature optical couplers and the same 6.2 mm base terminal blocks as in the PDT series, has now been included with spring cage connections in the range. The wiring, diagonally from above, is particularly convenient during assembly. The cost-intensive wiring is reduced yet again when the plug-in bridges are implemented. A side-effect is a cut in the likelihood of faulty wiring and time-consuming trouble-shooting. The standard PLC-OSP series can be implemented either as an input or output interface, thus simplifying ordering, and saving costs for warehousing and service. Since the unit is already completely equipped, there is no additional work involved with inserting the optical coupler. To allow even more flexibility, all individual components (base terminal block, optical coupler or relay) can also be ordered separately and combined individually. Input voltages of 24 V to 230 V PLC-OSP... on the control side is, like the proven screw clamp versions, available in all conventional industrial voltages from 24 V to 230 V. A further advantage is the ready-integrated input circuit. It consists of a status display and polarity reversal protection function, and guarantees that the operational status is displayed clearly, also preventing destruction of the optical electronics should the polarity be accidentally reversed. “…6” 8 (IEC) [mm2 ] rigid solid flexible stranded AWG Connection data 0.2-2.5 0.2-1.5 24-14 * The electrical data are determined by the relay. A2 I U [A] [V] * * 13+ 94 Efficient miniature optical couplers A1 14 Despite its small dimensions, the PLC miniature optical coupler is unusually efficient, has the typical sturdiness of optical couplers and is the instrument of 6,2 80 choice especially with high operating frequencies: – Switching capacity of up to 24 V DC/2 A, depending on the type, – IP 67-protected fully encapsulated optical electronics, – 2. kVrms electrical insulation between input/output, – Input or power optical couplers can be supplied as alternatives, – Wear-resistant switching, – Insensitive to vibration and shock. The optical coupler is securely anchored by an engagement lever. In the unlikely event of the optical coupler needing to be repaired, it can be disengaged, and – without disconnecting the wiring – replaced contact 13 on the load side, the continuous plug-in quickly and economically. bridges, which can be cut to length as desired, or the 2position jumper plugs guarantee quick, economical and Plug-in bridges save wiring fault-free wiring, whilst providing utmost clarity. This A big plus for cunning wiring professionals is the convenient plug-in bridge system FBST. Whether there makes complicated, time-consuming loop bridges a thing of the past! is an A1/A2 ground on the control side, or supply at Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 3 of 14 Universal PLC Interface with Optical Coupler – now also with spring cage connection system! Pcs./ Pkt. 24 V DC 120 V AC/110 V DC 230 V AC/220 V DC 2) equipped with input optical coupler PLC-OSP- 24DC/48DC/100 PLC-OSP-120UC/48DC/100 PLC-OSP-230UC/48DC/100 29 67 54 9 29 67 55 2 29 67 56 5 10 10 10 24 V DC 120 V AC/110 V DC 230 V AC/220 V DC 2) equipped with power optical coupler PLC-OSP- 24DC/24DC/2 PLC-OSP-120UC/24DC/2 PLC-OSP-230UC/24DC/2 29 67 47 1 29 67 48 4 29 67 49 7 10 10 10 Technical data Input optical coupler Input data Nominal input voltage UN 24 V DC 24 V DC 24, 120, 230 V AC/DC Output data Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Output connection Output circuit Voltage drop at max. limiting continuous current General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Standards/regulations Installation position/assembly Type of connection 120 V AC/ 24 V DC 120 V AC/ 110 V DC 110 V DC 230 V AC/ 230 V AC/ 220 V DC 2) 220 V DC 2) 0.8-1.2 0.8-1.1 0.8-1.2 0.8-1.1 0.8 x UN 0.8 x UN 0.8 x UN 0.8 x UN 0.4 x UN 0.3 x UN 0.4 x UN 0.25 x UN 8 mA 4 mA 9 mA 4 mA 20 µs 6 ms 20 µs 6 ms 300 µs 10 ms 500 µs 10 ms 300 Hz 10 Hz 300 Hz 10 Hz operation indicator, polarity protection diode, damping diode operation indicator, bridge rectifier PLC-O…/48DC/100 48 V DC 3 V DC 100 mA PLC-O…/24DC/2 33 V DC 3 V DC 2 A (see derating curve catalog part 6, page 27) – 15 A (10 ms) – – 2-conductor floating 2-conductor floating polarity reversal protection and surge voltage protection ≤1V ≤ 200 mV 2.5 kV, 50 Hz, 1 min. – 20 °C to + 60 °C 100 % ED V0 in acc. with UL 94 IEC 664/IEC 664 A/DIN VDE 0110, contamination class 2, surge voltage protection category III, as desired, in rows with zero spacing spring cage connection 1 ) Further input voltages available on request. Notes: 2 ) For voltages higher than 250 V (e.g. L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 Marking systems and mounting material, see catalog part 3/4. The rated cross section (see catalog part 6, page 151) refers to untreated conductors without ferrules. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. Due to the input circuit integrated in the base terminal block (see catalog part 6, page 33), a 60 V optical coupler, OTP-60DC/…, is used with the 120 V and 230 V modules. The PLC-ATP separating plate must always be installed at the beginning and end of a PLC terminal strip. For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. PHOENIX CONTACT page 4 of 14 http://www.phoenixcontact.com Permissible range (in reference to UN) Switching level 1-Signal (“H”) 0-Signal (“L”) Typ. input current at UN Typ. turn-on time for UN Typ. turn-off time for UN Transmission frequency flimit Input circuit Power optical coupler TNR: 5087390-00 PLC interface, consisting of base terminal block PLC-BSP…/21 and pluggable miniature optical coupler (see catalog part 6, page 33), for mounting on 3 Order No. 30.10.98 PLC interface, consisting of base terminal block PLC-BSP…/21 and pluggable miniature optical coupler (see catalog part 6, page 33), for mounting on 3 Type PHOENIX CONTACT Input voltage UN1) Description PLC Actuator Interface with Relay – now also with spring cage connection system! In interface applications between the PLC and actuators, such as motors, contactors, or solenoid valves, only an N/O contact is normally required. Here, people turn directly to the PLC-RSP...ACT output interface, specially optimized for these applications and consisting of a 6.2 mm base terminal block and pluggable miniature relay. In addition to the proven screw clamp connection version, the actuator interface is now available with spring cage connections. The wiring , diagonally from above, is particularly convenient during assembly. Alternatively, the actuator interface can also be supplied with a miniature optical coupler. Optimum use of plug-in bridges. The actuator interface attains the maximum degree of efficiency with the convenient FBST plug-in bridge system. PLC-RSP...ACT makes effective use of the bridging facilities for the A1/A2 connection on the coil side, for the load supply at connection 13 on the contact side, and for the load return line. Especially effective here are the 500 mm long color-insulated continuous bridges that can easily be cut to the required length and inserted in the bridge shafts in a flash. No stripping, no pressing on of ferrules, no connecting. This makes complicated, time-consuming loop bridges a thing of the past! Assessment of savings: – Reduction in wiring by eliminating the need for modular terminal blocks and using all bridging facilities: approx. 60%. Further advantages: PLC-RSP...ACT naturally offers the same benefits as all other PLC series with relay: – Available either as gold or power contact relay, – Integrated input circuit, – Switching capacity up to 250 V AC/6 A, – The relay can be removed for replacement using the “…6” 8 (IEC) [mm2 ] rigid solid flexible stranded AWG Connection data 0.2-2.5 0.2-1.5 24-14 * The electrical data are determined by the relay. A2 13 A1 BB I U [A] [V] * * 14 80 6,2 94 No need for output terminal blocks Unlike conventional coupling relays, all the actuator connections, including the load return line (!), are connected directly to the PLC actuator interface. PLCRSP...ACT can thus be used directly as an output terminal strip with integrated interface function for the outgoing actuator cables, without the need for additional modular terminal blocks. (See also structural diagram in catalog part 6, page 28.) Assessment of savings: – Elimination of the costs of two output terminal blocks for switching and load return lines, – Space savings of approx. 80%, – Time saving approx. 60%, – Reduction in wiring thanks to plug-in bridges. – – – – engagement lever, Operational safety with IP67-protected relays Reliable isolation acc. to DIN VDE 0106-101 User-specific marking Inflammability class V0 in acc. with UL94. Headquarters: © Phoenix Contact GmbH & Co. KG• Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 5 of 14 PLC Actuator Interface with Relay – now also with spring cage connection system! Description PLC interface, consisting of base terminal block PLC-BSP…ACT and pluggable miniature relay (see catalog part 6, page 32), for mounting on 3 Input voltage UN 24 V DC2) Type Order No. Pcs./ Pkt. equipped with power contact relay PLC-RSP- 24DC/ACT 29 67 34 5 10 Technical data 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 250 V AC Min. switching capacity General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Mechanical service life Standards/regulations Installation position/assembly Type of connection single contact, 1 N/O contact4) AgSnO 250 V AC/DC 2) 12 V AC/DC 6A on request 10 mA 140 W 20 W 18 W 23 W 40 W 1500 VA 120 mW 4 kV, 50 Hz, 1 min. – 20 °C to + 60 °C 100 % ED V0 in acc. with UL 94 107 cycles IEC 664/IEC 664 A/DIN VDE 0110, contamination class 3, Surge voltage category III, DIN VDE 0160 (in relev. parts), IEC 255/DIN VDE 0435 (in relev. parts), DIN VDE 0106-101: 1986-11, increased insulation I/O 3) as desired, in rows with zero spacing spring cage connection 1 ) Further input voltages available on request. Notes: 2 ) For voltages higher than 250 V (e.g. L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 3 ) For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. The rated cross section (see catalog part 6, page 151) refers to untreated conductors without ferrules. ) N/C contact on request. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. The PLC-ATP separating plate (see catalog part 6, page 34) must always be installed at the beginning and end of a PLC terminal strip. PHOENIX CONTACT 4 Marking systems and mounting material, see catalog part 3/4. http://www.phoenixcontact.com 24 V DC TNR: 5087390-00 Output data Contact type Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Max. power rating, ohmic load: 24 V DC see diagram catalog part 6, page 25 9 mA 5 ms 8 ms operation indicator, polarity protection diode, damping diode 30.10.98 Input data Nominal input voltage UN Permissible input voltage range Typ. input current at UN Typ. response time at UN Typ. release time at UN Input circuit PHOENIX CONTACT page 6 of 14 PLC Actuator Interface with Optical Coupler – now also with spring cage connection system! In interface applications between the PLC and actuators, such as motors, contactors, or solenoid valves, only an N/O function is normally required. Here, people turn directly to the PLC-OSP...ACT output interface, specially optimized for these applications and consisting of a 6.2 mm base terminal block and pluggable miniature optical coupler. In addition to the proven screw clamp connection version, the actuator interface is now available with spring cage connections. The wiring , diagonally from above, is particularly convenient during assembly. Alternatively, the actuator interface can also be supplied with a miniature relay. Optimum use of plug-in bridges The actuator interface attains the maximum degree of efficiency with the convenient FBST plug-in bridge system. PLC-OSP...ACT makes effective use of the bridging facilities for the A1/A2 connection on the coil side, for the load supply at connection 13 on the contact side, and for the load return line. Especially effective here are the 500 mm long color-insulated continuous bridges that can easily be cut to the required length and inserted in the bridge shafts in a flash. No stripping, no pressing on of ferrules, no connecting. This makes complicated, time-consuming loop bridges a thing of the past! Assessment of savings: – Reduction in wiring by eliminating the need for modular terminal blocks and using all bridging facilities: approx. 60%. Further advantages: PLC-OSP...ACT naturally offers the same benefits as all other PLC series with optical coupler: – Switching capacity of up to 24 V DC/2 A, depending on the type, – Wear-resistant switching, – Integrated input circuit, “…6” 8 (IEC) [mm2 ] rigid solid flexible stranded AWG Connection data 0.2-2.5 0.2-1.5 24-14 * The electrical data are determined by the relay. A2 13+ A1 BB I U [A] [V] * * 14 80 6,2 94 No need for output terminal blocks! Unlike conventional coupling relays, all the actuator connections, including the load return line (!), are connected directly to the PLC actuator interface. PLCOSP...ACT can thus be used directly as an output terminal strip with integrated interface function for the outgoing actuator cables, without the need for additional modular terminal blocks. (See also structural diagram in catalog part 6, page 28.) Assessment of savings: – Elimination of the costs of two output terminal blocks for switching and load return lines, – Space savings of approx. 80%, – Time saving approx. 60%, – Reduction in wiring thanks to plug-in bridges. – Input or power optical coupler can be supplied, – Optical coupler can be removed for replacement using the engagement lever, – IP67-protected fully encapsulated optical electronics, – Insensitive to vibration and shock, – User-specific marking – Inflammability class V0 in acc. with UL94. Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 7 of 14 PLC Actuator Interface with Optical Coupler – now also with spring cage connection system! Description PLC interface, consisting of base terminal block PLC-BSP…ACT and pluggable miniature optical coupler (see catalog part 6, page 33), for mounting on 3 Input voltage UN1) Type Order No. Pcs./ Pkt. 24 V DC equipped with power optical coupler PLC-OSP- 24DC/24DC/2/ACT 29 67 50 7 10 24 V DC 24 V DC 0.8-1.2 0.8 x UN 0.4 x UN 8 mA 20 µs 300 µs 300 Hz operation indicator, polarity protection diode, damping diode Technical data 1 ) Further input voltages available on request. Notes: Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 Marking systems and mounting material, see catalog part 3/4. The rated cross section (see catalog 6, page 151) refers to untreated conductors without ferrules. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. The PLC-ATP separating plate must always be installed at the beginning and end of a PLC terminal strip. For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. http://www.phoenixcontact.com Installation position/assembly Type of connection 2.5 kV, 50 Hz, 1 min. – 20 °C to + 60 °C 100 % ED V0 in acc. with UL 94 IEC 664/IEC 664 A/DIN VDE 0110, contamination class 2, surge voltage protection category III, as desired, in rows with zero spacing spring cage connection TNR: 5087390-00 General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Standards/regulations 33 V DC 3 V DC 2 A (see derating curve, catalog part 6, page 27) 15 A (10 ms) 2-conductor floating polarity reversal protection and surge voltage protection ≤ 200 mV 30.10.98 Output data Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Output connection Output circuit Voltage drop at max. limiting continuous current PHOENIX CONTACT Input data Nominal input voltage UN Permissible range (in reference to UN) Switching level 1 signal (“H”) 0 signal (“L”) Typ. input current at UN Typ. turn-on time for UN Typ. turn-off time for UN Transmission frequency flimit Input circuit PHOENIX CONTACT page 8 of 14 PLC Sensor Interface with Relay – now also with spring cage connection system! In interface applications between the PLC and sensors, such as proximity switches, limit switches, or auxiliary contacts, often only an N/O function is required. Here, people turn directly to the PLCRSP...SEN input interface, specially optimized for these applications and consisting of a 6.2 mm base terminal block and pluggable miniature relay. In addition to the proven screw clamp connection version, the sensor interface is now available with spring cage connections. The wiring , diagonally from above, is particularly convenient during assembly. Optimum use of plug-in bridges. The sensor interface attains the maximum degree of efficiency with the convenient FBST plug-in bridge system. PLC-RSP...SEN makes effective use of the bridging facilities for the sensor/switch voltage supply, for the supply and sensor ground at the A2 connection, and for the common supply potential of the PLC at connection 13. No stripping, no pressing on of ferrules, no connecting. This makes complicated, timeconsuming loop bridges a thing of the past! Assessment of savings: – Reduction in wiring by eliminating the need for modular terminal blocks and using all bridging facilities: approx. 60 %. Further advantages: PLC-RSP...ACT naturally offers the same benefits as all other PLC series with relay: – Switching capacity up to 250 V AC/6 A, – Integrated input circuit, – Available either as gold or power contact relay, – The relay can be removed for replacement using the engagement lever, – Operational safety with IP67-protected relays, “…6” 8 (IEC) [mm2 ] rigid solid flexible stranded AWG I U [A] [V] Connection data 0.2-2.5 0.2-1.5 24-14 * The electrical data are determined by the relay. 13 A2 14 BB * * A1 80 6,2 94 No need for input terminal blocks Unlike previous input relays, all the sensor connections, including the voltage supply for the sensors/switches (!), are connected directly to the PLC sensor interface. PLC-RSP...SEN can thus be used directly as a terminal strip with integrated interface function for the incoming sensor cables, without the need for additional modular terminal blocks. (See also structural diagram in catalog part 6, page 30.) Assessment of savings: – Elimination of the costs of two (three) modular terminal blocks for sensor/switch supply, signal and sensor ground (in the case of three-conductor initiators). – Space savings of approx. 80 %, – Time saving approx. 60 %, – Reduction in wiring thanks to plug-in bridges. – Reliable isolation acc. to DIN VDE 0106-101 – User-specific marking – Inflammability class V0 in acc. with UL94. Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 9 of 14 PLC Sensor Interface with Relay – now also with spring cage connection system! Input voltage UN1) Description PLC interface, consisting of base terminal block PLC-BSP…SEN and pluggable miniature relay (see catalog part 6, page 32), for mounting on 3 PLC interface, consisting of base terminal block PLC-BSP…SEN and pluggable miniature relay (see catalog part 6, page 32), for mounting on 3 Type Order No. Pcs./ Pkt. 24 V DC 120 V AC/110 V DC 230 V AC/220 V DC 2) equipped with universal multi-layer contact relay PLC-RSP- 24DC/1AU/SEN PLC-RSP-120UC/1AU/SEN PLC-RSP-230UC/1AU/SEN 29 67 37 4 29 67 39 0 29 67 41 3 10 10 10 24 V DC 120 V AC/110 V DC 230 V AC/220 V DC 2) equipped with power contact relay PLC-RSP- 24DC/1/SEN PLC-RSP-120UC/1/SEN PLC-RSP-230UC/1/SEN 29 67 36 1 29 67 38 7 29 67 40 0 10 10 10 Technical data Input data Nominal input voltage UN General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Mechanical service life Standards/regulations Installation position/assembly Type of connection 4 kV, 50 Hz, 1 min. – 20 °C to + 55 °C (24 V types to +60 °C) 100 % ED V0 in acc. with UL 94 107 cycles IEC 664/IEC 664 A/DIN VDE 0110, contamination class3, Surge voltage category III, DIN VDE 0160 (in relev. parts), IEC 255/DIN VDE 0435 (in relev. parts), DIN VDE 0106-101: 1986-11, increased insulation I/O 4) as desired, in rows with zero spacing spring cage connection 1 ) Further input voltages available on request. Notes: 2 ) For voltages higher than 250 V (e.g. L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 3 ) If the maximum values indicated are exceeded, the gold layer is destroyed. The values of the AgSnO contact are then valid. 4 5 ) For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. ) N/C contact on request. Marking systems and mounting material, see catalog part 3/4. The rated cross section (see catalog part 6, page 151) refers to untreated conductors without ferrules. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. Due to the input circuit integrated in the base terminal block (see catalog part 6, page 32), a 60 V relay, REL-MR-60DC/..., is used with the 120 V and 230 V modules. The PLC-ATP separating plate (see catalog part 6, page 34) must always be installed at the beginning and end of a PLC terminal strip. PHOENIX CONTACT page 10 of 14 http://www.phoenixcontact.com Min. switching capacity PLC-R…/1AU/SEN Single contact, 1 N/O contact5) AgSnO + 5 µ Au 3) 30 V AC/36 V DC 100 mV 50 mA 50 mA 1 mA 1.2 W – – – – – 100 µW TNR: 5087390-00 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 250 V AC PLC-R…/1/SEN Single contact, 1 N/O contact5) AgSnO 250 V AC/DC 2) 12 V AC/DC 6A on request 10 mA 140 W 20 W 18 W 23 W 40 W 1500 VA 120 mW 30.10.98 Output data Contact type Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Max. power rating, ohmic load: 24 V DC 120, 230 V AC/DC 120 V AC/ 230 V AC/ 110 V DC 220 V DC 2) see diagram catalog part 6, page 25 9 mA 3.5/3 mA 3 mA 5 ms 6 ms 7 ms 8 ms 15 ms 15 ms operation indicator, polarity protection diode, damping diode operation indicator, bridge rectifier PHOENIX CONTACT Permissible input voltage range Typ. input current at UN Typ. response time at UN Typ. release time at UN Input circuit 24 V DC PLC Sensor Interface with Optical Coupler – now also with spring cage connection system! In interface applications between the PLC and sensors, such as proximity switches, limit switches, or auxiliary contacts, often only an N/O function is required. Here, people turn directly to the PLCOSP...SEN input interface, specially optimized for these applications and consisting of a 6.2 mm base terminal block and pluggable miniature optical coupler. In addition to the proven screw clamp connection version, the sensor interface is now available with spring cage connections. The wiring , diagonally from above, is particularly convenient during assembly. Optimum use of plug-in bridges. The sensor interface attains the maximum degree of efficiency with the convenient FBST plug-in bridge system. PLC-OSP...SEN makes effective use of the bridging facilities for the sensor/switch voltage supply, for the supply and sensor ground at the A2 connection, and for the common supply potential of the PLC at connection 13. Especially effective here are the 500 mm long color-insulated continuous bridges that can easily be cut to the required length and inserted in the bridge shafts in a flash. No stripping, no pressing on of ferrules, no connecting. This makes complicated, timeconsuming loop bridges a thing of the past! Assessment of savings: – Reduction in wiring by eliminating the need for modular terminal blocks and using all bridging facilities: approx. 60 %. Further advantages: PLC-OSP...SEN naturally offers the same benefits as all other PLC series with optical coupler: – Switching capacity of up to 24 V DC/2 A, depending on the type, – Wear-resistant switching, “…6” 8 (IEC) [mm2 ] rigid solid flexible stranded AWG Connection data 0.2-2.5 0.2-1.5 24-14 * The electrical data are determined by the relay. 13+ A2 14 BB I U [A] [V] * * A1 80 6,2 94 No need for input terminal blocks Unlike previous input optical couplers, all the sensor connections, including the voltage supply for sensors/ switches (!), are connected directly to the PLC sensor interface. PLC-OSP...SEN can thus be used directly as a terminal strip with integrated interface function for the incoming sensor cables, without the need for additional modular terminal blocks. (See also structural diagram in catalog part 6, page 30.) Assessment of savings: – Elimination of the costs of two (three) modular terminal blocks for sensor/switch supply, signal and sensor ground (in the case of three-conductor initiators). – Space savings of approx. 80 %, – Time saving approx. 60 %, – Reduction in wiring thanks to plug-in bridges – – – – – – Integrated input circuit, Input or power optical coupler can be supplied, IP67-protected fully encapsulated optical electronics, Insensitive to vibration and shock, User-specific marking Inflammability class V0 in acc. with UL94. Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 11 of 14 PLC Sensor Interface with Optical Coupler – now also with spring cage connection system! Pcs./ Pkt. 24 V DC 120 V AC/110 V DC 230 V AC/220 V DC 2) equipped with input optical coupler PLC-OSP- 24DC/48DC/100/SEN PLC-OSP-120UC/48DC/100/SEN PLC-OSP-230UC/48DC/100/SEN 29 67 57 8 29 67 58 1 29 67 59 4 10 10 10 24 V DC 120 V AC/110 V DC 230 V AC/220 V DC 2) equipped with power optical coupler PLC-OSP- 24DC/24DC/2/SEN PLC-OSP-120UC/24DC/2/SEN PLC-OSP-230UC/24DC/2/SEN 29 67 51 0 29 67 52 3 29 67 53 6 10 10 10 Technical data Input optical coupler Input data Nominal input voltage UN 24 V DC 24 V DC 120, 230 V AC/DC Output data Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Output connection Output circuit Voltage drop at max. limiting continuous current General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Standards/regulations Installation position/assembly Type of connection 120 V AC/ 24 V DC 120 V AC/ 110 V DC 110 V DC 230 V AC/ 230 V AC/ 220 V DC 2) 220 V DC 2) 0.8-1.2 0.8-1,1 0.8-1.2 0.8-1.1 0.8 x UN 0.8 x UN 0.8 x UN 0.8 x UN 0.4 x UN 0.3 x UN 0.4 x UN 0.25 x UN 8 mA 4 mA 9 mA 4 mA 20 µs 6 ms 20 µs 6 ms 300 µs 10 ms 500 µs 10 ms 300 Hz 10 Hz 300 Hz 10 Hz operation indicator, polarity protection diode, damping diode operation indicator, bridge rectifier PLC-O…/48DC/100/SEN 48 V DC 3 V DC 100 mA PLC-O…/24DC/2/SEN 33 V DC 3 V DC 2 A (see derating curve catalog part 6, page 27) – 15 A (10 ms) – – 2-conductor floating 2-conductor floating polarity reversal protection and surge voltage protection ≤1V ≤ 200 mV 2,5 kV, 50 Hz, 1 min. – 20 °C to +60 °C 100 % ED V0 in acc. with UL 94 IEC 664/IEC 664 A/DIN VDE 0110, contamination class 2, surge voltage protection category III, as desired, in rows with zero spacing spring cage connection 1 ) Further input voltages available on request. Notes: 2 ) For voltages higher than 250 V (e.g. L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 Marking systems and mounting material, see catalog part 3/4. The rated cross section (see catalog part 6, page 151) refers to untreated conductors without ferrules. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. Due to the input circuit integrated in the base terminal block (see catalog part 6, page 33), a 60 V optical coupler, OTP-60DC/…, is used with the 120 V and 230 V modules. The PLC-ATP separating plate must always be installed at the beginning and end of a PLC terminal strip. For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. PHOENIX CONTACT page 12 of 14 http://www.phoenixcontact.com Permissible range (in reference to UN) Switching level 1 signal (“H”) 0 signal (“L”) Typ. input current at UN Typ. turn-on time for UN Typ. turn-off time for UN Transmission frequency flimit Input circuit Power optical coupler TNR: 5087390-00 PLC interface, consisting of base terminal block PLC-BSP…SEN and pluggable miniature optical coupler (see catalog part 6, page 33), for mounting on 3 Order No. 30.10.98 PLC interface, consisting of base terminal block PLC-BSP…SEN and pluggable miniature optical coupler (see catalog part 6, page 33), for mounting on 3 Type PHOENIX CONTACT Input voltage UN1) Description PLC Accessories Input terminal block PLC-ESK The 9 mm wide input terminal block PLC-ESK is the same shape as the PLC interface terminal blocks. It is used to feed in bridging potentials. Its nominal current is 32 A! When currents are ≤ 6 A, they can be fed in directly at the connecting terminal blocks of one of the connected PLC interfaces. Plug-in bridges FBST The differently colored, insulated plug-in bridges FBST make optimum use of the advantages of PLC interfaces. The 2-position single plug-in bridges FBST 6 are especially suited for bridging a smaller number of modules and residual currents ≤ 6 A. When a circuit is supplied from both sides, they offer the advantage that the circuit can be opened at any point, allowing all the other modules to continue to be supplied at the same time. The 500 mm continuous plug-in bridge FBST 500 is even more convenient. All bridges are equipped with a groove which allows them to be removed with a screwdriver. If bridges with different potentials meet in neighboring functional blocks, the separating plate PLC-ATP should be placed between them. Separating plate PLC-ATP The PLC-ATP separating plate must always be installed at the beginning and end of a terminal strip. In addition to pure visual separation of functional blocks, it is also necessary in certain cases to place the separating plate between adjacent PLC interface terminal blocks, e.g. when 3 phases (L1, L2, L3) are used on the contact side of the PLC relay terminal blocks. PLC-ATP is equipped with prescored break-out points at the bridging positions, so that individual bridges can pass through if necessary. Description Type Order No. Pcs./ Pkt. Input terminal block, for the input of up to four potentials, for mounting on 3 Technical data Connection cross section: PLC-ESK GY 29 66 50 8 5 Color solid 0.2-4 mm2 stranded 0.2-4 mm2 AWG 24-10 32 A 250 V AC 1) same shape as PLC standard series, terminal block width 9 mm gray Cont. plug-in bridge, 500 mm long, insulated, can be cut to any length, for power distribution with PLC... red blue gray Imax: 32 A FBST 500-PLC RD FBST 500-PLC BU FBST 500-PLC GY 29 66 78 6 29 66 69 2 29 66 83 8 20 20 20 red blue gray Imax: 6 A FBST 6-PLC RD FBST 6-PLC BU FBST 6-PLC GY 29 66 23 6 29 66 81 2 29 66 82 5 50 50 50 PLC-ATP BK 29 66 84 1 25 Max. current Max voltage Terminal block dim.: Plug-in bridge, 2-pos., 6 mm long, insulated, for power distribution with PLC Separating plate, 2 mm thick, should be installed at the start and end of a PLC terminal strip. Furthermore, it is used for: – visual separation of groups, – protective separation of different voltages of neighboring PLC interfaces in acc. with DIN VDE 0106-101, – separation of neighboring bridges with different potentials, – separation of PLC interfaces with voltages > 250 V Color: black 1 ) For voltages higher than 250 V (L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate should be installed Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 12 00 • http://www.phoenixcontact.com PHOENIX CONTACT page 13 of 14 Type Order No. Pcs./ Pkt. ZB 6: UNPRINTED 10 51 00 3 10 ZB 6/WH-100: UNPRINTED 50 60 93 5 100 ZB 6, LGS: CONSEC. NUMBERS ZB 6, LGS: 1-10 ZB 6, LGS: 11-20 etc. to ZB 6, LGS: 991-1000 10 51 01 6 10 ZB 6, LGS: 1-9 10 51 12 6 10 ZB 6, LGS: IDENTICAL NOS. ZB 6, LGS: 1 ZB 6, LGS: 2 etc. to ZB 6, LGS: 100 10 51 03 2 10 ZB 6, LGS: L1-N, PE ZB 6, LGS: U-N 10 51 41 4 10 51 43 0 10 10 ZB 6, QR: CONSEC. NUMBERS ZB 6, QR: 1-10 ZB 6, QR: 11-20 etc. to ZB 6, QR: 991-1000 10 51 02 9 10 ZB 6, QR: IDENTICAL NOS. ZB 6, QR: 1 ZB 6, QR: 2 etc. to ZB 6, QR: 100 10 51 04 5 10 Zack strip, printed vertically: 2) 10-section with PLC input numbers e.g.: I 0.0 to I 0.7 (to max. E 127.7) ZB 6, QR: PLC INPUT…1) 10 51 45 6 10 Zack strip, printed vertically: 2) 10-section with PLC output numbers e.g.: O 0.0 to O 0.7 (to max. A 127.7) ZB 6, QR: PLC OUTPUT…1) 10 51 44 3 10 ZB 6: SO/CMS…3) 10 50 49 9 1 Zack strip, unprinted: 10-section, for individual labelling with marker pen or CMS system, sufficient for labelling 100 PLC interface terminal blocks as above, however, large batch, sufficient for labelling 1000 PLC interface terminal blocks Zack strip, printed horizontally: 2) 10-section with consecutive numbers 1-10 11-20 etc. to 991-1000 Zack strip, printed horizontally: 2) 9-section with the numbers 1-9 Zack strip, printed horizontally: 2) 10-section with identical numbers 1/1/1 2/2/2 etc. to 100/100/100 Zack strip, printed horizontally: 2) 10-section L1, L2, L3, N, PE, L1, L2, L3, N, PE U, V, W, N, 6, U, V, W, N, 6 Zack strip, printed vertically: 2) 10-section with consecutive numbers 1-10 11-20 etc. to 991-1000 Zack strip, printed vertically: 2) 10-section with identical numbers 1/1/1 2/2/2 etc. to 100/100/100 Zack strip, special printing, 10-section, divisible, marked according to customer requirements 1) Please specify the required marking with order. 2 ) 10 identically marked strips form a packing unit (PU). 3 ) Please specify the required marking and color with order. Marking direction: horizontal "LGS" or vertical "QR", see catalog part 3/4. PHOENIX CONTACT page 14 of 14 TNR: 5087390-00 Description 30.10.98 In addition to the standard color white, the Zack strip can also be supplied in other colors (see catalog part 3, page 36). Marking is either done manually with the MPEN or elegantly with the computer marking system CMS. Alternatively, the labels can be ordered preprinted with numbers, symbols or PLC input and output numbers. PHOENIX CONTACT Zack strip ZB 6 This marking system combines the advantage of easy handling with the advantage of a reasonable price. The zack strip consists of 10 individual labels which are joined together and can be easily separated at any point. For marking equipment, the labels can be clicked into the marker groove of the engagement lever. The system advantage: economical, quick, optimum appearance. http://www.phoenixcontact.com PLC Labelling ZB 6