Delta DCS12S0A0S03NFA Non-isolated point of load dc/dc power modules: 4.5~14vin, 0.59-5.0v/6aout Datasheet

FEATURES

High efficiency: 94. 3% @ 12Vin, 5V/6A out

Small size and low profile:

12.2x 12.2x 7.25mm (0.48”x 0.48”x 0.29”)

Surface mount packaging

Standard footprint

Voltage and resistor-based trim

Pre-bias startup

Output voltage tracking

No minimum load required

Output voltage programmable from
0.59Vdc to 5.0Vdc via external resistor

Fixed frequency operation

Input UVLO, output OCP

Remote on/off

ISO 9001, TL 9000, ISO 14001, QS9000,
OHSAS18001 certified manufacturing
facility


UL/cUL 60950-1 (US & Canada)
CE mark meets 73/23/EEC and 93/68/EEC
directives
Delphi DCS, Non-Isolated Point of Load
DC/DC Power Modules: 4.5~14Vin, 0.59-5.0V/6Aout
The Delphi Series DCS, 4.5-14V input, single output, non-isolated
Point of Load DC/DC converters are the latest offering from a world
OPTIONS
leader in power systems technology and manufacturing -- Delta

Negative/Positive on/off logic
Electronics, Inc. The DCS series provides a programmable output

Tracking feature
voltage from 0.59 V to 5.0V using an external resistor and has flexible
and programmable tracking features to enable a variety of startup
voltages as well as tracking between power modules. This product
family is available in surface mount and provides up to 6A of output
current in an industry standard footprint. With creative design
APPLICATIONS
technology

Telecom / DataCom

Distributed power architectures

Servers and workstations

LAN / WAN applications

Data processing applications
and
optimization
of
component
placement,
these
converters possess outstanding electrical and thermal performance,
as well as extremely high reliability under highly stressful operating
conditions.
DATASHEET
DS_DCS12S0A0S06NFA_12072012
TECHNICAL SPECIFICATIONS
(TA = 25°C, airflow rate = 300 LFM, Vin =4.5Vdc and 14Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
DCS12S0A0S06NFA
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Sequencing Voltage
Operating Ambient Temperature
Storage Temperature
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current (VIN = 12.0Vdc, Io =
0, module enabled)
Off Converter Input Current (VIN = 12.0Vdc,
module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Adjustable Range
Output Voltage Regulation
Vo ≦ Vin –0.6
Typ.
Max.
-0.3
15
-0.3
Vin max
V
-40
-55
85
125
℃
℃
4.5
14.0
V
4.4
V
V
V
A
mA
mA
mA
3.2
0.4
Vin=4.5V to14V, Io=Io,max
Vo,set = 0.6 Vdc
Vo,set = 3.3 Vdc
6.0
10
25
0.8
1
(5Hz to 20MHz, 1μH source impedance; Vin =0 to 14V,
Io= Iomax ;
with 0.5% tolerance for external resistor used to set
output voltage)
(selected by an external resistor)
Units
86
-1.5
Vo,set
V
A2S
mAp-p
+1.5
%Vo,set
0.59
5.0
V
-2.5
0.4
10
10
5
0.4
5
+2.5
%Vo,set
mV
Vo,set
mV
mV
%Vo,set
mV
%Vo,set
Total Output Voltage Range
Output Voltage Ripple and Noise
For Vo>=2.5V
For Vo<2.5V
For Vo>=2.5V
For Vo<2.5V
For Vo>=2.5V
For Vo<2.5V
Over sample load, line and temperature
5Hz to 20MHz bandwidth
Peak-to-Peak
Full Load, 1µF+10uF ceramic+47uF ceramic
30
60
mV
Full Load, 1µF+10uF ceramic+47uF ceramic
10
20
6
3
225
0.5
mV
A
% Vo,set
% Io
Adc
200
200
20
mV
mV
µs
2
2
4
ms
ms
ms
µF
µF
Line(VIN=VIN, min to VIN, max)
Load(Io=Io, min to Io, max)
Temperature(Tref=TA, min to TA, max)
RMS
Output Current Range
Output Voltage Over-shoot at Start-up
Output DC Current-Limit Inception
Output Short-Circuit Current (Hiccup Mode)
DYNAMIC CHARACTERISTICS
Dynamic Load Response
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time to 10% of Peak Deviation
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Output Voltage Rise Time
Output Capacitive Load
EFFICIENCY
Vo=5.0V
Vo=2.5V
Vo=1.2V
Vo=0.59V
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, (Negative logic)
Logic Low Voltage
Logic High Voltage
Logic Low Current
Logic High Current
ON/OFF Control, (Positive Logic)
Logic High Voltage
Logic Low Voltage
Logic Low Current
Logic High Current
Tracking Slew Rate Capability
Tracking Delay Time
Tracking Accuracy
GENERAL SPECIFICATIONS
MTBF
Weight
0
Vout=5.0V
Io,s/c
10µF Tan & 1µF Ceramic load cap, 2.5A/µs
50% Io, max to 100% Io, max
100% Io, max to 50% Io, max
Io=Io.max
Time for Von/off to Vo=10% of Vo,set
Time for Vin=Vin,min to Vo=10% of Vo,set
Time for Vo to rise from 10% to 90% of Vo,set
Full load; ESR ≧0.15mΩ
Full load; ESR ≧10mΩ
47
47
Vin=12V, 100% Load
Vin=12V, 100% Load
Vin=12V, 100% Load
Vin=12V, 100% Load
800
1800
94.3
90.5
82.9
71.5
%
%
%
%
600
kHz
Module On, Von/off
Module Off, Von/off
Module On, Ion/off
Module Off, Ion/off
-0.2
3.5
0.6
Vin,max
10
1
V
V
µA
mA
Module On, Von/off
Module Off, Von/off
Module On, Ion/off
Module Off, Ion/off
3.0
-0.3
Vin,max
0.6
1
10
2
V
V
mA
µA
V/msec
ms
mV
mV
Delay from Vin.min to application of tracking voltage
Power-up
2V/mS
Power-down 1V/mS
Io=80% of Io, max; Ta=25°C
DS_DCS12S0A0S06NFA_12072012
0.1
10
100
100
17
1.5
M hours
grams
2
CHARACTERISTICS CURVES
The following figures provide Converter Efficiency versus output current
Figure 1: Converter efficiency vs. output current (5.0Vout)
Figure 2: Converter efficiency vs. output current (3.3 Vout)
Figure 3: Converter efficiency vs. output current (2.5 Vout)
Figure 4: Converter efficiency vs. output current (1.8Vout)
DS_DCS12S0A0S06NFA_12072012
3
Figure 5: Converter efficiency vs. output current (1.2Vout)
Figure 6: Converter efficiency vs. output current (0.59Vout)
The following figures provide typical output ripple and noise at 25oC
Figure 7: Output ripple & noise at 12Vin, 5.0V/6A out
Figure 8: Output ripple & noise at 12Vin, 3.3V/6A out
CH1:VOUT, 20mV/div, 1uS/div
CH1:VOUT, 20mV/div, 1uS/div
DS_DCS12S0A0S06NFA_12072012
4
Figure 9: Output ripple & noise at 12Vin, 2.5V/6A out
Figure 10: Output ripple & noise at 12Vin, 1.8V/6A out
CH1:VOUT, 20mV/div, 1uS/div
CH1:VOUT, 20mV/div, 1uS/div
Figure 11: Output ripple & noise at 12Vin, 1.2 V/6A out
Figure 12: Output ripple & noise at 12Vin, 0.59 V/6A out
CH1:VOUT, 20mV/div, 1uS/div
CH1:VOUT, 20mV/div, 1uS/div
DS_DCS12S0A0S06NFA_12072012
5
The following figures provide typical start-up using input voltage at 25oC
Figure 13: Turn on delay time at 12Vin, 5.0V/6A out
Figure 14: Turn on delay time at 12Vin, 3.3V/6A out
(Top trace : VOUT, 2V/div; Bottom trace: VIN, 5V/div; 2mS/div)
(Top trace: VOUT, 1V/div; Bottom trace: VIN, 5V/div; 2mS/div)
Figure 15: Turn on delay time at 12Vin, 2.5V/6A out
Figure 16: Turn on delay time at 12Vin, 1.8V/6A out
Top trace: VOUT, 1V/div; Bottom trace: VIN, 5V/div; 2mS/div)
(Top trace : VOUT, 0.5V/div, Bottom trace: VIN, 5V/div;
DS_DCS12S0A0S06NFA_12072012
2mS/div)
6
Figure 17: Turn on delay time at 12Vin, 1.2V/6A out
(Top trace: VOUT, 0.5V/div; Bottom trace: VIN, 5V/div;
Figure 18: Turn on delay time at 12Vin, 0.59V/6A out
2mS/div)
(Top trace: VOUT, 0.2V/div; Bottom trace: VIN, 5V/div;
2mS/div)
The following figures provide transient response to dynamic load change at 25oC
Figure 19: Typical transient response to step load change at
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,
5.0Vout (Cout = 1uF ceramic, 47uF+10μFceramic)
CH1 : VOUT, 0.1V/div, 200uS/div
DS_DCS12S0A0S06NFA_12072012
Figure 20: Typical transient response to step load change at
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,
3.3Vout (Cout = 1uF ceramic, 47uF+10μFceramic)
CH1 : VOUT, 0.1V/div, 200uS/div
7
Figure 21: Typical transient response to step load change at
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,
2.5Vout (Cout = 1uF+ 47uF+10μF ceramic)
CH1 : VOUT, 0.1V/div, 200uS/div
Figure 22: Typical transient response to step load change at
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,
1.8Vout (Cout = 1uF+ 47uF+10μF ceramic)
CH1 : VOUT, 0.1V/div,200uS/div
Figure 23: Typical transient response to step load change at
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,
1.2Vout (Cout = 1uF+ 47uF+10μF ceramic)
CH1 : VOUT, 0.1V/div, 200uS/div
Figure 24: Typical transient response to step load change at
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,
0.59Vout (Cout = 1uF+ 47uF+10μF ceramic)
CH1 : VOUT, 0.1V/div, 200uS/div
DS_DCS12S0A0S06NFA_12072012
8
The following figures provide output short circuit current at 25oC
Figure 25: Output short circuit current 12Vin, 5.0Vout
Figure 26: Output short circuit current 12Vin, 0.59 Vout
Top trace: Vo, 1V/div; Bottom trace: Io, 5A/div;
Top trace: Vo, 1V/div ;Bottom trace: Io, 5A/div; 20ms/div
20ms/div
The following figures provide output short circuit current at 25oC
Figure 27:Tracking function, Vtracking=5.5 V, Vout= 5.0V, full load
Figure 28:Tracking function, Vtracking=0.8V,Vout= 0.59V, full load
Top trace:Vtracking, 1V/div; Bottom trace: Vout,1 V/div;1ms/div
Top trace:Vtracking, 0.2V/div;Bottom trace: Vout,0.2 V/div; 1ms/div
DS_DCS12S0A0S06NFA_12072012
9
DESIGN CONSIDERATIONS
TEST CONFIGURATIONS
Input Source Impedance
To maintain low noise and ripple at the input voltage, it is
critical to use low ESR capacitors at the input to the
module. A highly inductive source can affect the stability
of the module. An input capacitance must be placed
close to the modules input pins to filter ripple current and
ensure module stability in the presence of inductive
traces that supply the input voltage to the module.
Figure 29: Input reflected-ripple test setup
Vo
1uF
10uF
SCOPE
tantalum ceramic
Resistive
Load
GND
Note: Use a 10μF tantalum and 1μF capacitor. Scope
measurement should be made using a BNC connector.
Figure 30: Peak-peak output noise and startup transient
measurement test setup.
VI
Vo
GND
Figure 31: Output voltage and efficiency measurement test
setup
Note: All measurements are taken at the module terminals.
When the module is not soldered (via socket), place
Kelvin connections at module terminals to avoid
measurement errors due to contact resistance.
(
Vo  Io
)  100 %
Vi  Ii
DS_DCS12S0A0S06NFA_12072012
10
DESIGN CONSIDERATIONS (CON.)
FEATURES DESCRIPTIONS
Safety Considerations
Remote On/Off
For safety-agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards.
The DCS series power modules have an On/Off pin for
remote On/Off operation. Both positive and negative
On/Off logic options are available in the DCS series power
modules.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power module
has extra-low voltage (ELV) outputs when all inputs are
ELV.
The input to these units is to be provided with a
maximum 10A fuse in the ungrounded lead.
Input Under voltage Lockout
At input voltages below the input under voltage lockout
limit, the module operation is disabled. The module will
begin to operate at an input voltage above the under
voltage lockout turn-on threshold.
For positive logic module, connect an open collector
(NPN) transistor or open drain (N channel) MOSFET
between the On/Off pin and the GND pin (see figure32).
Positive logic On/Off signal turns the module ON during
the logic high and turns the module OFF during the logic
low. When the positive On/Off function is not used, leave
the pin floating or tie to Vin (module will be On).
For negative logic module, the On/Off pin is pulled high
with an external pull-up 5kΩ resistor (see figure 33).
Negative logic On/Off signal turns the module OFF during
logic high and turns the module ON during logic low. If the
negative On/Off function is not used, leave the pin floating
or tie to GND. (module will be on)
Vo
V in
Over-Current Protection
I O N /O F F
To provide protection in an output over load fault
condition, the unit is equipped with internal over-current
protection. When the over-current protection is
triggered, the unit enters hiccup mode. The units
operate normally once the fault condition is removed.
O n/O ff
RL
Q1
GND
Figure 32: Positive remote On/Off implementation
Vo
Vin
Rpullup
I O N /O FF
On/Off
RL
Q1
GND
Figure 33: Negative remote On/Off implementation
DS_DCS12S0A0S06NFA_12072012
11
FEATURES DESCRIPTIONS (CON.)
Vo
Remote Sense
RLoad
TRIM
The DCS provide Vo remote sensing to achieve proper
regulation at the load points and reduce effects of
distribution losses on output line. In the event of an open
remote sense line, the module shall maintain local sense
regulation through an internal resistor. The module shall
correct for a total of 0.5V of loss. The remote sense line
impedance shall be < 10.
Distribution Losses
Distribution Losses
Vo
Vin
Rtrim
GND
Figure 35: Circuit configuration for programming output voltage
using an external resistor
Table 1 provides Rtrim values required for some common
output voltages, By using a 0.5% tolerance trim resistor, set
point tolerance of ±1.5% can be achieved as specified in
the electrical specification.
Sense
RL
GND
Distribution
FigureLosses
34: Effective
Distribution
Losses
circuit configuration for remote sense
operation
Output Voltage Programming
The output voltage of the DCS can be programmed to any
voltage between 0.59Vdc and 5.0Vdc by connecting one
resistor (shown as Rtrim in Figure 35) between the TRIM
and GND pins of the module. Without this external
resistor, the output voltage of the module is 0.59 Vdc. To
calculate the value of the resistor Rtrim for a particular
output voltage Vo, please use the following equation:
 5.91 
Rtrim  
 K
Vo  0.591
Rtrim is the external resistor in kΩ
Vo is the desired output voltage.
For example, to program the output voltage of the DNS
module to 5.0Vdc, Rtrim is calculated as follows:
Table 1
Vo(V)
Rtrim(KΩ)
0.590
Open
0.600
656.700
1.000
14.450
1.200
9.704
1.500
6.502
1.800
4.888
2.500
3.096
3.300
2.182
5.000
1.340
Certain restrictions apply on the output voltage set point
depending on the input voltage. These are shown in the
Output Voltage vs. Input Voltage Set Point Area plot in
Figure 36. The Upper Limit curve shows that for output
voltages of 0.9V and lower, the input voltage must be lower
than the maximum of 14V. The Lower Limit curve shows
that for output voltages of 3.8V and higher, the input voltage
needs to be larger than the minimum of 4.5V.
 5.91 
Rtrim  
 K  1.34 K
 5.0  0.591
Figure 36: Output Voltage vs. Input Voltage Set Point Area plot
showing limits where the output voltage can be set for different
input voltages.
DS_DCS12S0A0S06NFA_12072012
12
FEATURE DESCRIPTIONS (CON.)
Voltage Margining
Output voltage margining can be implemented in the DCS
modules by connecting a resistor, R margin-up, from the Trim
pin to the ground pin for margining-up the output voltage
and by connecting a resistor, R margin-down, from the Trim pin
to the output pin for margining-down. Figure 37 shows the
circuit configuration for output voltage margining. If
unused, leave the trim pin unconnected. A calculation tool
is available from the evaluation procedure which
computes the values of Rmargin-up and Rmargin-down for a
specific output voltage and margin percentage.
Vin
Vo
Rmargin-down
Q1
On/Off Trim
Rmargin-up
Rtrim
Q2
GND
Figure 37: Circuit configuration for output voltage margining
Output Voltage Sequencing
When an analog voltage is applied to the SEQ pin, the
output voltage tracks this voltage until the output reaches
the set-point voltage. The final value of the SEQ voltage
must be set higher than the set-point voltage of the
module. The output voltage follows the voltage on the
SEQ pin on a one-to-one basis. By connecting multiple
modules together, multiple modules can track their output
voltages to the voltage applied on the SEQ pin.
For proper voltage sequencing, first, input voltage is
applied to the module. The On/Off pin of the module is
left unconnected (or tied to GND for negative logic
modules or tied to VIN for positive logic modules) so that
the module is ON by default. After applying input voltage
to the module, a minimum 10msec delay is required
before applying voltage on the SEQ pin. This delay gives
the module enough time to complete its internal power-up
soft-start cycle. During the delay time, the SEQ pin
should be held close to ground (nominally 50mV ± 20
mV). This is required to keep the internal op-amp out of
saturation thus preventing output overshoot during the
start of the sequencing ramp. By selecting resistor R1
(see Figure. 39) according to the following equation
 24950 
R1  

Vin  0.05 
The DCS 12V 6A modules include a sequencing feature,
EZ-SEQUENCE that enables users to implement various
types of output voltage sequencing in their applications.
This is accomplished via an additional sequencing pin.
When not using the sequencing feature, either tie the SEQ
pin to VIN or leave it unconnected.
Figure 38: Sequential Start-up
The voltage at the sequencing pin will be 50mV when
the sequencing signal is at zero.
DS_DCS12S0A0S06NFA_12072012
13
FEATURE DESCRIPTIONS (CON.)
Power Good
The DCS modules provide a Power Good (PGOOD)
After the 10msec delay, an analog voltage is applied to
signal that is implemented with an open-drain output to
the SEQ pin and the output voltage of the module will
indicate that the output voltage is within the regulation
track this voltage on a one-to-one volt bases until the
limits of the power module. The PGOOD signal will be
output reaches the set-point voltage. To initiate
simultaneous shutdown of the modules, the SEQ pin
voltage is lowered in a controlled manner. The output
de-asserted to a low state if any condition such as over
temperature, over current or loss of regulation occurs that
would result in the output voltage going ±10% outside the
set point value. The PGOOD terminal should be
voltage of the modules tracks the voltages below their
connected through a pull up resistor (suggested value
set-point voltages on a one-to-one basis. A valid input
100KΩ) to a source of 5VDC or lower.
voltage must be maintained until the tracking and output
voltages reach ground potential.
When using the EZ-SEQUENCETM feature to control
Monotonic Start-up and Shutdown
start-up of the module, pre-bias immunity during startup is
disabled. The pre-bias immunity feature of the module
relies on the module being in the diode-mode during
The DCS 6A modules have monotonic start-up and
shutdown behavior for any combination of rated input
voltage, output current and operating temperature range.
start-up. When using the EZ-SEQUENCETM feature,
modules goes through an internal set-up time of 10msec,
and will be in synchronous rectification mode when the
voltage at the SEQ pin is applied. This will result in the
module sinking current if a pre-bias voltage is present at
the output of the module.
Figure 39: Circuit showing connection of the sequencing signal to
the SEQ pin.
DS_DCS12S0A0S06NFA_12072012
14
THERMAL CONSIDERATIONS
THERMAL CURVES
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
Figure 41: Temperature measurement location
The allowed maximum hot spot temperature is defined at 120℃
Output Current(A)
DCS12S0A0S06 Output Current vs. Ambient Temperature and Air Velocity
@Vin=12V Vout=5.0V (Either Orientation)
6
Natural
Convection
5
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel.
100LFM
4
200LFM
300LFM
3
400LFM
500LFM
2
PWB
FANCING PWB
600LFM
1
MODULE
0
55
60
65
70
75
80
85
90
95
100
105
Ambient Temperature (℃)
Figure 42: Output current vs. ambient temperature and air
velocity@Vin=12V, Vout=5.0V(Either Orientation)
50.8(2.00")
AIR VELOCITY
AND AMBIENT
TEMPERATURE
SURED BELOW
THE MODULE
Output Current(A)
DCS12S0A0S06 Output Current vs. Ambient Temperature and Air Velocity
@Vin = 12V Vout=3.3V(Either Orientation)
6
Natural
Convection
AIR FLOW
5
100LFM
200LFM
4
300LFM
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
3
400LFM
Figure 40: Wind tunnel test setup
500LFM
2
Thermal Derating
600LFM
1
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power
module should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
DS_DCS12S0A0S06NFA_12072012
0
55
60
65
70
75
80
85
90
95
100
105
Ambient Temperature (℃)
Figure 43: Output current vs. ambient temperature and air
velocity@Vin=12V, Vout=3.3V(Either Orientation)
15
Output Current(A)
DCS12S0A0S06 Output Current vs. Ambient Temperature and Air Velocity
@Vin = 12V Vout=2.5V(Either Orientation)
Output Current(A)
6
DCS12S0A0S06 Output Current vs. Ambient Temperature and Air Velocity
@Vin = 12V Vout=0.59V(Either Orientation)
6
Natural
Convection
5
Natural
Convection
5
100LFM
4
100LFM
200LFM
4
200LFM
300LFM
300LFM
3
3
400LFM
2
400LFM
2
500LFM
1
1
0
55
60
65
70
75
80
85
90
95
100
105
Ambient Temperature (℃)
Figure 44: Output current vs. ambient temperature and air
velocity@Vin=12V, Vout=2.5V(Either Orientation)
Output Current(A)
0
55
60
65
70
75
80
85
90
95
100
105
Ambient Temperature (℃)
Figure 47: Output current vs. ambient temperature and air
velocity@Vin=12V, Vout=0.59 V(Either Orientation)
DCS12S0A0S06 Output Current vs. Ambient Temperature and Air Velocity
@Vin = 12V Vout=1.8V(Either Orientation)
6
Natural
Convection
5
100LFM
200LFM
4
300LFM
3
400LFM
500LFM
2
1
0
55
60
65
70
75
80
85
90
95
100
105
Ambient Temperature (℃)
Figure 45: Output current vs. ambient temperature and air
velocity@Vin=12V, Vout=1.8V(Either Orientation)
Output Current(A)
DCS12S0A0S06 Output Current vs. Ambient Temperature and Air Velocity
@Vin = 12V Vout=1.2V(Either Orientation)
6
Natural
Convection
5
100LFM
200LFM
4
300LFM
400LFM
3
500LFM
2
1
0
55
60
65
70
75
80
85
90
95
100
105
Ambient Temperature (℃)
Figure 46: Output current vs. ambient temperature and air
velocity@Vin=12V, Vout=1.2V(Either Orientation)
DS_DCS12S0A0S06NFA_12072012
16
PICK AND PLACE LOCATION
RECOMMENDED PAD LAYOUT
SURFACE-MOUNT TAPE & REEL
DS_DCS12S0A0S06NFA_12072012
17
LEAD (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE
Note: The temperature refers to the pin of DCS, measured on the pin Vout joint.
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE
Temp.
Peak Temp. 240 ~ 245 ℃
220℃
Ramp down
max. 4℃ /sec.
200℃
150℃
Preheat time
90~120 sec.
Time Limited 75 sec.
above 220℃
Ramp up
max. 3℃ /sec.
25℃
Time
Note: The temperature refers to the pin of DCS, measured on the pin Vout joint.
DS_DCS12S0A0S06NFA_12072012
18
MECHANICAL DRAWING
DS_DCS12S0A0S06NFA_12072012
19
PART NUMBERING SYSTEM
DCS
12
S
0A0
S
06
N
Product
Series
Input Voltage
Numbers of
Outputs
Output
Voltage
Package
Type
Output
Current
On/Off
logic
S - Single
0A0 Programmable
S - SMD
03- 3A
06 - 6A
12 - 12A
20 - 20A
DCT- 3A
DCS - 6A
DCM - 12A
DCL - 20A
04 - 2.4~5.5V
12 – 4.5~14V
F
N- negative
P- positive
A
Option Code
F- RoHS 6/6
(Lead Free)
A - Standard Function
MODEL LIST
Model Name
Packaging
Input Voltage
Output Voltage
Output Current
Efficiency
12Vin, 5Vdc @ 6A
DCS12S0A0S06NFA
SMD
4.5 ~ 14Vdc
0.59V~ 5.0Vdc
6A
94. 3%
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email: [email protected]
Europe:
Telephone: +31-20-655-0967
Fax: +31-20-655-0999
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
Ext. 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta
for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license
is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these
specifications at any time, without notice.
DS_DCS12S0A0S06NFA_12072012