Altech CB4/2 High temperature ceramic euroblock Datasheet

CB4
HIGH TEMPERATURE
CERAMIC EUROBLOCKS™
Suitable for use in high
temperature applications up
to 600°C (1112°F).
Applications include hot
melt glue guns, furnaces,
heaters, process equipment
and machinery. Terminal
blocks are offered with
mounting holes for panel
mounting or free floating
applications.
Ceramic
Insulation Material
Approvals
•
•
•
•
Compact, space saving
Tubular screw clamp
Free float or panel mount
Temperature range:
600°C (1112°F)
• Standard color: white
• Material
Housing: ceramic
Clamp:
brass
Screws: zinc plated steel
C
US
C
24-12 AWG 24-12 AWG
Wire Range
CB6
CB16
Ceramic
Ceramic
US
C
22-10 AWG 20-10 AWG
US
20-6 AWG
18-6 AWG
Voltage Rating
300V
300V
300V
300V
300V
300V
Current Rating
30 A
20 A
40 A
30 A
76 A
65 A
No. of Poles
1 (free floating)
2 (free floating)
2 (with mounting holes)
3 (free floating)
3 (with mounting holes)
1 Pole
2 Pole
Cat. No.
Std. Pk.
Cat. No.
Std. Pk.
CB4/1
CB4/2
CB4/2H
CB4/3
CB4/3H
50
50
50
50
50
CB6/1
50
CB6/2H
50
CB16/2H
50
CB6/3H
50
CB16/3H
50
2 Pole with
mounting hole
Cat. No.
3 Pole
Std. Pk.
3 Pole with
mounting hole
T
T
T
T
T
W
W
W
C
W
W
C
D1
D1
H
H
H
H
H
D2
D2
Dimensions mm
W
T
H
C
D1
D2
Fixing
Screw
Stripping
Length
CB4/1
CB4/2
CB4/2H
CB4/3
CB4/3H
1
2
2
3
3
POLE
POLE
POLE
POLE
POLE
23
23
23
25
25.4
11
18
24
25
36
18.5
18.5
18.5
18.5
18.5
*
*
14.6
*
13
6
3.5
M3X16
6
3.5
M3X16
6
6
6
6
6
CB6/1
CB6/2H
CB6/3H
1 POLE
2 POLE
3 POLE
25
25.5
25.5
12
26
41
19.5
19.5
19.5
*
12.6
15
6
6
M3X16
M3X16
6
6
6
CB16/2H
CB16/3H
2 POLE
3 POLE
28
27.5
31
48
23.2
23.2
16.5
17
6
6
M3X20
M3X20
8.5
8.5
3.5
3.5
Note: All dimensions are shown in mm, to convert to inches please divide by 25.4.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
47
CMT4
MINI FEED-THROUGH
15mm DIN Rail
CMT4S
For wire-to-wire connecting in
control, automation,
instrumentation and power
distribution applications.
Altech “miniature” terminal
blocks offer tremendous space
advantage as demanded by
certain wiring configurations.
FUSE BLOCKS
Terminal Width
6 mm
6 mm
Certain electrical and control
systems require protection by
fuses. The terminal has a
hinged carrier that has a
specially designed space for a
cartridge type glass fuse of size
Ø5 x 20 or Ø5 x 25 mm. The
fuse can be engaged or
disengaged by the movement
of the carrier.
Height x Length
29 x 27 mm
29 x 46 mm
Stripping Length
9 mm
9 mm
Insulation Material
Polyamide 6.6
Polyamide 6.6
Type of Connection
2 screw clamps & 1 tapped hole
for cross connection
—
2 screw clamps, 2 solder points
and 1 tapped hole for cross connection
—
Altech fuse terminals are also
available with light indication CSFL 4U (L). A specially
designed built-in circuit gives
light indication in the event of
fuse blow out.
Wire Range
22-10 AWG
Voltage Rating
Fuses are sold separately
by Altech, see page 34
for details.
Type of Fuse Used
Approvals
C
US
C
US
0.5-4 sq.mm
22-10 AWG
22-12 AWG Upto 1.5 sq.mm 22-10 AWG
300 V
400 V
300 V
300 V
160 V
300 V
Current Rating
35 A
32 A
35 A
25 A
15 A
35 A
Torque
6 lb-in
0.5 Nm
7 lb-in
7 lb-in
0.5 Nm
7 lb-in
Cat. No.
Std. Pk.
Cat. No.
Std. Pk.
Terminal Block
CMT4
100
CMT4S
50
End Plate
EPCMT4
50
EPCMT4
50
Isolation Partition
PPCMT4
50
PPCMT4
50
CA602
100
CA602
50
2 pole
3 pole
4 pole
10 pole
CA727/2
CA727/3
CA727/4
CA727/10
100
50
50
10
CA727/2
CA727/3
CA727/4
CA727/10
100
50
50
10
2 pole
3 pole
4 pole
10 pole
CA747/2
CA747/3
CA747/4
CA747/10
100
50
50
10
CA747/2
CA747/3
CA747/4
CA747/10
100
50
50
10
CA703/1
CA704/1
CA705/1
CA732/10
CA732/10-A
CA732/100
100
100
100
100
100
10
CA703/1
CA704/1
CA705/1
CA732/10
CA732/10-A
CA732/100
100
100
100
100
100
10
CA607/S/Q
100
CA607/S/Q
100
CA714/2
CA714/3
CA714/4
CA714/10
100
100
50
25
CA714/2
CA714/3
CA714/4
CA714/10
100
100
50
25
MT2
100
MT2
100
DIN Rail
for ordering information
refer to page 62
End Stop
for ordering information
refer to page 63
Internal
Jumper
Insulated
Internal
Jumper
Current
Bars
2 pole
3 pole
4 pole
10 pole
10 pole (breakable)
100 pole
Shorting Sleeve & Screw
External
Jumper
* Add required voltage to part
number as a suffix,
i.e. CSFL4U(L)/24 fo 24V DC
46
2 pole
3 pole
4 pole
10 pole
Marking Tags (MT Type)
(MT Type on Lever)
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CMT4SU
CSFL4U(L)*
CSFL4U
CGMT4
6 mm
8 mm
8 mm
6 mm
29 x 35.5 mm
43 x 58 mm
43 x 58 mm
28.5 x 27 mm
9 mm
9.5 mm
9.5 mm
9 mm
Polyamide 6.6
Polyamide 6.6
Polyamide 6.6
Polyamide 6.6
2 uneven level solder points & 1
tapped hole for cross connection
—
2 screw clamps
2 screw clamps
2 screw clamps
US
C
Ø5x20, Ø5x25mm
C
Ø5x20, Ø5x25mm
US
C
US
22-10 AWG
300 V
160 V
300 V
600 V
600 V
600 V
600 V
600 V
600 V
15 A
15 A
20 A
6.3 A
6.3 A
8A
6.3 A
6.3 A
8A
–
–
7 lb-in
0.5 Nm
7 lb-in
7 lb-in
0.5 Nm
7 lb-in
Cat. No.
Std. Pk.
Cat. No.
Cat. No.
0.5-4 sq.mm 22-10 AWG
US
22-10 AWG 0.5-4 sq.mm 22-10 AWG
7 lb-in
0.5 Nm
7 lb-in
Std. Pk.
Cat. No.
Std. Pk.
CMT4SU
100
CSFL4U
100
CSFL4U(L)*
100
CGMT4
50
EPCMT4
50
EPCSFL4U
50
EPCSFL4U
50
PPCMT4
50
PPCSFL4U
50
PPCSFL4U
50
CA602
50
CA602
100
CA602
100
CA727/2
CA727/3
CA727/4
CA727/10
100
50
50
10
CA747/2
CA747/3
CA747/4
CA747/10
100
50
50
10
CA703/1
CA704/1
CA705/1
CA732/10
CA732/10-A
CA732/100
10
10
10
10
100
10
CA607/S/Q
10
CA711/2
CA711/3
CA711/4
CA711/10
100
100
50
25
CA711/2
CA711/3
CA711/4
CA711/10
100
100
50
25
MT8
MT2
100
100
MT8
MT2
100
100
MT2
100
MT2
Std. Pk.
22-10 AWG
C
22-14 AWG Upto 1.5 sq.mm 22-14 AWG
–
0.5-4 sq.mm 22-10 AWG
—
100
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
47
CMB4
MINI FEED-THROUGH
Panel Mount
For use when space constraints
require extremely compact
solutions and internal jumping is
required.
Individual components can be
used to build your own
assemblies. Just snap the
required number of terminal
block components together and
place a Mounting Section on
each end.
The CMB 4 accepts internal
jumpers and standard marking
tags.
• Extremely compact and
cost effective
• High density
• Screw-cage clamp
• Internal jumping provision
• Polyamide 6.6
• Standard color: gray
EP CMB4
Preassembled blocks are
also available for quick
and easy installations.
Terminal Width
6 mm
Height x Length
28 x 27 mm
Stripping Length
9 mm
Insulation Material
Polyamide 6.6
Type of Connection
2screw clamps & 1 tapped hole for cross connection
See Dimensions below.
Approvals
C
US
Wire Range
22-10 AWG
0.5-4 sq.mm 22-10 AWG
Voltage Rating
300 V
400 V
300 V
Current Rating
35 A
32 A
35 A
Torque
7 lb-in
0.5 Nm
7 lb-in
Cat. No.
Std. Pk.
Terminal Block
CMB4
100
Mounting Section
EPCMB4
50
Separator Plate
SPCMB4
100
Mounting Screw*
Internal
Jumper
2 pole
3 pole
4 pole
10 pole
CA727/2
CA727/3
CA727/4
CA727/10
100
50
50
10
Insulated
Internal
Jumper
2 pole
3 pole
4 pole
10 pole
CA747/2
CA747/3
CA747/4
CA747/10
100
50
50
10
CA703/1
CA704/1
CA705/1
CA732/10
CA732/10-A
CA732/100
100
100
100
100
100
10
CA607/S/Q
100
CA714/2
CA714/3
CA714/4
CA714/10
100
100
50
25
MT2
100
Current
Bars
2 pole
3 pole
4 pole
10 pole
10 pole (breakable)
100 pole
Shorting Sleeve & Screw
2 pole
3 pole
4 pole
10 pole
External
Jumper
Marking Tags
(MT Type)
b
a
Dimensions mm (in.)
CMB4
No. of
Cat No. Poles
CMB4/2
2
CMB4/3
3
CMB4/4
4
CMB4/5
5
CMB4/6
6
CMB4/7
7
CMB4/8
8
CMB4/9
9
CMB4/10 10
CMB4/11 11
CMB4/12 12
CMB4/13 13
CMB4/14 14
CMB4/15 15
CMB4/16 16
CMB4/17 17
CMB4/18 18
CMB4/19 19
CMB4/20 20
CMB4/21 21
CMB4/22 22
CMB4/23 23
CMB4/24 24
Hole
Width (a) Spacing (b)
26 (1.02)
19 (0.75)
32 (1.26)
25 (0.98)
38 (1.50)
31 (1.22)
44 (1.73)
37 (1.46)
50 (1.97)
43 (1.69)
56 (2.20)
49 (1.93)
62 (2.44)
55 (2.17)
68 (2.68)
61 (2.40)
74 (2.91)
67 (2.64)
80 (3.15)
73 (2.87)
86 (3.39)
79 (3.11)
92 (3.62)
85 (3.35)
98 (3.86)
91 (3.58)
104 (4.09)
97 (3.82)
110 (4.33) 103 (4.06)
116 (4.57) 109 (4.29)
122 (4.80) 115 (4.53)
128 (5.04) 121 (4.76)
134 (5.28) 127 (5.00)
140 (5.51) 133 (5.24)
146 (5.75) 139 (5.47)
152 (5.98) 145 (5.71)
158 (6.22) 151 (5.94)
Mounting Section
EPCMB4
* Any length M3 screw may be used.
48
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
CENC4
BUSBAR SYSTEM
Panel Mount
CENC16
CENC35
A quick reliable solution for
ground, neutral or low
voltage distribution
applications. The Busbar
System consists of a
busbar, busbar supports,
and screw clamp terminals
for terminating wires
NEB 10 (10 x 3 mm) and
NEB 6 (6 x 6 mm), tin plated
copper busbars are
available in one meter
lengths. Both have a 140A
current carrying capacity.
NES plastic support with
fixing screws for holding 10
x 3 & 6 x 6 busbar makes
placing of busbar an easy
task. Busbars up to 200 mm
length should be supported
at ends by two busbar
supports. For busbars
exceeding 200 mm length,
it is recommended to
provide intermediate
busbar support. Easy to
operate CENC clamp
secures wire to the busbar.
Terminal Width
7.5 mm
9.8 mm
14.5 mm
Height x Length
30 x 23.3 mm
36 x 23.3 mm
45 x 27.3 mm
Stripping Length
12 mm
16 mm
16 mm
Insulation Material
Polyamide 6.6
Polyamide 6.6
Polyamide 6.6
Type of Connection
1 screw clamp connection
1 screw clamp connection
1 screw clamp connection
Approvals
C
US
C
US
C
US
Wire Range
22-12 AWG 0.5-6 sq.mm 22-12 AWG 9-6 AWG 6-16 sq.mm 10-6 AWG 7-2 AWG 10-35 sq.mm 8-2 AWG
Current Rating*
25 A
Torque
14 lb-in
41 A
0.8 Nm
76 A
14 lb-in
76 A
125 A
14 lb-in 2.0 Nm 17.5 lb-in
Cat. No.
25 lb-in 2.5 Nm 25 lb-in
Cat. No.
Std. Pk.
Terminal Block Green Cap **
CENC4
50
Busbar
(10 x 3 mm)
NEB10
1m
NEB10
1m
NEB10
1m
Busbar
(6 x 6 mm)
NEB6
1m
NEB6
1m
NEB6
1m
Plastic Support
with Fixing Screw
NES
50
NES
50
NES
50
End Clamp/Bus bar
support for rail mounting
CA202
50
CA202
50
CA202
50
Marking Tags
(MT Type)
MT5
100
MT6
100
MT6
100
CENC16
Std. Pk.
125 A
50
Cat. No.
CENC35
Std. Pk.
50
* 140A current carrying capacity of busbar should be taken
into account while connecting loads.
** Consult for other available colors.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com