XP Power ALM120PS19 Ac-dc power supply Datasheet

ALM120 Series
AC-DC Power Supplies
120 Watts
• Medical & IT Safety Approvals
• Energy Efficiency Level VI & EU CoC Tier 2 Compliant
• 4th Edition Medical EMC
• IP32 Environmental Rating
• Class I and Class II Versions
• <0.15 W Standby Power
• 0 °C to 60 °C Operation
• Low Earth Leakage Current
• 3 Year Warranty
Dimensions:
The ALM120 series of medical external power supplies is fully approved to international medical &
IT safety standards. It has been designed with very high efficiency and low standby power, enabling
it to meet the latest environmental legislation. The unit has a fully sealed enclosure complying with
IP32 and a smooth surface finish making it easier to wipe down in a clinical setting.
ALM120:
6.732 x 2.677 x 1.496” (171.0 x 68.0 x 38.0 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation
Model Number(1,2,3,4)
10.00 A
8.00 A
6.32 A
5.00 A
±5%
ALM120PS12
ALM120PS15
ALM120PS19
ALM120PS24
12.0 V
15.0 V
19.0 V
24.0 V
120 W
Notes
1. For class II versions, add suffix 'C2-8' to the end of the part number e.g.
ALM120PS24C2-8.
2. For optional input connector retention clip add suffix ‘-A’ to the model number,
e.g. ALM120PS24-A (not available for C2 versions)
3. For optional output connector, DC barrel jack, add suffix -B5 to the model
number, e.g. ALM120PS24-B5 (not available for 12 & 15 V models)
4. Power de-rated <100 VAC for 12 & 15 V models, refer to input specifications.
Mechanical Details
0.195
(4.9)
6.73 (171.0)
1.41 ±0.079
(36.0 ±2.0)
2.67
(68.0)
35.42 ±0.79 (900.0 ±20.0)
KPPX-4P
K
(Non-Locking)
0.787 ±0.079 (ø20.0 ±2.0)
Shell
1.96 ±0.787 (50.0 ±20.0)
AC Input
IEC 320-C8
Pin
1
2
3
4
Connection
+Vout
+Vout
RTN
RTN
Standard Models:
Shell
Functional Earth
C2 Models: Floating
1.49
(38.0)
0.039 (1.0)
3.95 (100.3)
AC Input
IEC 320-C14
Optional -B5 Versions
1.73
(44.0)
1.59
(40.3)
Return (-)
5.51 (140.0)
Output (+)
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
2. Weight: 1.1 lbs (0.5 kg) approx.
3. For European mains lead order part EU-MAINS-IEC for C14 versions,
or EU-MAINS-8 for C8 versions.
4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8
for C8 versions.
1
5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8
for C8 versions.
6. Output connector: 4 pin power din with pin 1 & 2 - positive and pin
3 & 4 - return, equivalent to KPPX-4P (non-locking). Optional for 19 & 24 models:
DC barrel jack; 5.5 outer diameter, 2.5 mm inner diameter with centre positive.
www.xppower.com
ALM120 Series
AC-DC Power Supplies
Input
Characteristic
Minimum
Input Voltage
80
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
No Load Input Power
Input Protection
47
Typical
Units
Notes & Conditions
264
VAC
19 & 24 V models: Derate linearly from 100% load at 90 VAC
to 80% load at 80 VAC, 300 VAC/5 s maximum.
12 & 15 V models: Derate linearly from 100% load at 100
VAC to 80% load at 80 VAC, 300 VAC/5 s maximum.
63
Hz
A
A
Maximum
1.2/0.6
60/120
>0.9
160
250
0.15
T3.15A/250 VAC internal fuse in both line & neutral
Measured at 115/230 VAC
115/230 VAC, cold start at 25 °C
EN61000-3-2 Class A
264 VAC, 60 Hz
µA
W
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Total Regulation
Min.
12
20
Typ.
Max.
24
±2
Units
VDC
%
1
2
50
±0.5
±5
s
ms
ms
%
%
4
%
1.5
% pk-pk
10
175
150
%
%
%
95
%/°C
µA
264 VAC, 60 Hz
Maximum
+60
Units
°C
Notes & Conditions
Derate from 100% load at 40 °C to 30% load at 60 °C
30
Transient Response
Ripple and Noise
Overshoot
Overload Protection
Overvoltage Protection
Short Circuit Protection
Thermal Protection
Temperature Coefficient
Patient Leakage Current
5
115
Trip and restart (hiccup), auto resetting
Measured internally, auto resetting
0.02
Notes & Conditions
See Models and Ratings table
At 50% load
No minimum load required
Full load and 115/230 VAC
Maximum deviation, recovering to less than 1% within
500 µs for 50-75-50% load change
20 MHz bandwidth, measured with 20 MHz Bandwidth and
10 µF electrolytic in parallel with 0.1 µF ceramic capacitor.
At turn on / turn off
Recycle mains to reset
Environmental
Characteristic
Operating Temperature
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Minimum
0
Natural convection
5
-20
Typical
95
%RH
+80
°C
5000
m
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
Derating Curve
Non-condensing
Output Power (%)
100%
80%
60%
40%
20%
0
20
Ambient Temperature (ºC)
www.xppower.com
40
60
2
ALM120 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Efficiency
Maximum
Units
%
91
Isolation: Input to Output
Input to Ground
Output to Ground
45
85
Switching Frequency
Power Density
Weight
See Models and Ratings table and curves.
4000
VAC
2 x MOPP
1500
VAC
1 x MOPP (Class I versions only)
500
140
190
VAC
Class I versions only
PFC
Main Converter
kHz
W/in3
4.45
Mean Time Between Failure
Notes & Conditions
>300
kHrs
1.1 (500)
lb (g)
MIL-HDBK-217F at 25 °C GB
Efficiency Curves
100%
ALM120PS12
Efficiency
90%
115V
80%
230V
70%
60%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Load
ALM120PS24
100%
Efficiency
90%
115V
80%
230V
70%
60%
10%
20%
30%
6
40%
50%
60%
70%
80%
90%
100%
Load
EMC: Emissions
Phenomenon
Emissions
Harmonic Current
Voltage Flicker
Standard
EN55032
EN61000-3-2
EN61000-3-3
Test Level
Level B
Class A
www.xppower.com
Notes & Conditions
Conducted & Radiated
3
ALM120 Series
AC-DC Power Supplies
EMC: Immunity
Phenomenon
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
Test Level
3
10 V/m
3
Installation Class 3
10 V
4
Dip: 30% 500 ms
Dip: 60% 200 ms
Dip: 80% 5000 ms
Int: 100% 10 ms
Int: 100% 20 ms
Int: 100% 5000 ms
Dip: 30% 25 AC Cycles
Dip: 60% 5 AC Cycles
Int: 100% 0.5 AC Cycles
Int: 100% 1.0 AC Cycles
Int: 100% 250 AC Cycles
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Dips and Interruptions
EN60601-1-2
Criteria
A
A
A
A
A
A
A
A/B
B
A
A
B
A
A
A
A
B
Notes & Conditions
±15 kV air/±8 kV contact
80-2700 MHz. IEC60601-1-2 Ed.4 at other frequencies
High Line/Low Line
230 VAC 100% load, 100 VAC 25% load
Safety Approvals
Safety Agency
UL
TUV
CB
CE
UL
CSA
TUV
CB
Others
Safety Standard
UL62368-1
EN62368-1
IEC60950-1 & IEC62368-1
LVD
ANSI/AAMI ES 60601-1
CSA C22.2 No. 60601
EN60601-1
IEC60601-1
CCC, PSE, KC & RCM
Notes & Conditions
Information Technology
Medical
May require addtional importer information
Mechanical Details
0.195
(4.9)
6.73 (171.0)
1.41 ±0.079
(36.0 ±2.0)
2.67
(68.0)
KPPX-4P
(Non-Locking)
K
35.42 ±0.79 (900.0 ±20.0)
Shell
0.787 ±0.079 (ø20.0 ±2.0)
1.96 ±0.787 (50.0 ±20.0)
Pin
1
2
3
4
Connection
+Vout
+Vout
RTN
RTN
Standard Models:
Shell
Functional Earth
C2 Models: Floating
AC Input
IEC 320-C8
1.49
(38.0)
0.039 (1.0)
3.95 (100.3)
Optional -B5 Versions
AC Input
IEC 320-C14
Return (-)
1.73
(44.0)
1.59
(40.3)
5.51 (140.0)
Output (+)
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
2. Weight: 1.1 lbs (0.5 kg) approx.
3. For European mains lead order part EU-MAINS-IEC for C14 versions,
or EU-MAINS-8 for C8 versions.
4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8
for C8 versions.
5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8
for C8 versions.
6. Output connector: 4 pin power din with pin 1 & 2 - positive and pin
3 & 4 - return, equivalent to KPPX-4P (non-locking). Optional for 19 & 24 models:
DC barrel jack; 5.5 outer diameter, 2.5 mm inner diameter with centre positive.
www.xppower.com
22 Jun 17