Data Delay DDU11H-75C3 5-tap, ecl-interfaced fixed delay line (series ddu11h) Datasheet

DDU11H
data 3 
delay
devices, inc.
5-TAP, ECL-INTERFACED
FIXED DELAY LINE
(SERIES DDU11H)
FEATURES
•
•
•
•
PACKAGES
Five equally spaced outputs
Fits standard 16-pin DIP socket
Auto-insertable
Input & outputs fully 10KH-ECL interfaced & buffered
GND
1
16
GND
15
T1
T2
3
14
T3
T4
4
13
T5
IN
5
VEE
8
GND
N/C
T2
T4
IN
N/C
N/C
VEE
DDU11H-xx DIP
DDU11H-xxM Military DIP
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
GND
T1
T3
T5
N/C
N/C
N/C
N/C
DDU11H-xxC3 SMD
DDU11H-xxMC3 Mil SMD
PIN DESCRIPTIONS
FUNCTIONAL DESCRIPTION
IN
Signal Input
The DDU11H-series device is a 5-tap digitally buffered delay line. The
T1-T5
Tap Outputs
signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an
VEE
-5 Volts
amount determined by the device dash number (See Table). For dash
GND Ground
numbers less than 10, the total delay of the line is measured from T1 to
T5. The nominal tap-to-tap delay increment is given by one-fourth of the
total delay, and the inherent delay from IN to T1 is nominally 1.5ns. For dash numbers greater than or
equal to 10, the total delay of the line is measured from IN to T5. The nominal tap-to-tap delay increment
is given by one-fifth of this number.
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
•
•
•
•
•
•
Part
Number
DDU11H-4
DDU11H-5
DDU11H-8
DDU11H-10
DDU11H-20
DDU11H-25
DDU11H-50
DDU11H-75
DDU11H-100
DDU11H-150
DDU11H-200
DDU11H-250
DDU11H-300
DDU11H-400
DDU11H-500
Minimum input pulse width: 20% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 200mw typical (no load)
Operating temperature: -30° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
1.5ns
VCC IN
25%
T1
25%
T2
25%
T3
25%
T4
T5 GND
Functional diagram for dash numbers < 10
20%
20%
20%
20%
Total
Delay (ns)
2 ± 1.0 *
4 ± 1.0 *
6 ± 2.0 *
10 ± 2.0
20 ± 3.0
25 ± 3.0
50 ± 3.0
75 ± 4.0
100 ± 5.0
150 ± 7.5
200 ± 10.0
250 ± 12.5
300 ± 15.0
400 ± 20.0
500 ± 25.0
Delay Per
Tap (ns)
0.5 ± 0.3
1.0 ± 0.3
1.5 ± 0.4
2.0 ± 0.4
5.0 ± 1.0
5.0 ± 2.0
10.0 ± 2.0
15.0 ± 2.0
20.0 ± 2.0
30.0 ± 2.0
40.0 ± 2.0
50.0 ± 2.5
60.0 ± 3.0
80.0 ± 4.0
100.0 ± 5.0
* Total delay is referenced to first tap output
Input to first tap = 1.5ns ± 1ns
20%
NOTE: Any dash number between 4 and 500
not shown is also available.
VCC IN
T1
T2
T3
T4
T5 GND
Functional diagram for dash numbers >= 10
1997 Data Delay Devices
Doc #97035
12/10/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
DDU11H
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The DDU11H tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 20% of the total delay and periods as
small as 40% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The DDU11H relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VEE
VIN
TSTRG
TLEAD
MIN
-7.0
VEE - 0.3
-55
MAX
0.3
0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 75C)
PARAMETER
High Level Output Voltage
Low Level Output Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Doc #97035
12/10/97
SYMBOL
VOH
VOL
VIH
VIL
IIH
IIL
MIN
-1.020
-1.950
TYP
MAX
-0.735
-1.600
-1.070
-1.480
475
0.5
UNITS
V
V
V
V
µA
µA
NOTES
VIH = MAX,50Ω to -2V
VIL = MIN, 50Ω to -2V
VIH = MAX
VIL = MIN
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
DDU11H
PACKAGE DIMENSIONS
16 15 14 13
.400
TYP.
1
3
4
5
8
.800 TYP.
.020 .320
TYP. MAX.
.150
±.030
.100
TYP.
.018
TYP.
.010 TYP.
.300
TYP.
.700 TYP.
DDU11H-xx (Commercial DIP)
DDU11H-xxM (Military DIP)
.020 TYP.
.040
TYP.
16 15 14 13 12 11 10
.010±.002
9
.882
±.005
.710 .590
±.005 MAX.
1
2
3
4
5
.090
6
7
.007
±.005
8
.100
.700
.880±.020
.280
MAX.
.050
±.010
DDU11H-xxC3 (Commercial SMD)
DDU11H-xxMC3 (Military SMD)
Doc #97035
12/10/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
DDU11H
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
Ambient Temperature: 25oC ± 3oC
Supply Voltage (Vcc): -5.0V ± 0.1V
Input Pulse:
Standard 10KH ECL
levels
Source Impedance:
50Ω Max.
Rise/Fall Time:
2.0 ns Max. (measured
between 20% and 80%)
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
50Ω to -2V
5pf ± 10%
(VOH + VOL) / 2
(Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
REF
PULSE
GENERATOR
OUT
IN
TRIG
DEVICE UNDER
TEST (DUT)
T1
IN
T2
TRIG
OSCILLOSCOPE
T3
T4
T5
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
80%
50%
20%
80%
50%
20%
TRISE
OUTPUT
SIGNAL
VIL
TFALL
VOH
50%
50%
VOL
Timing Diagram For Testing
Doc #97035
12/10/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
4
Similar pages