Omron A16ZA-3003 Separate construction with cylindrical 16-dia. body Datasheet

Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.)
A16
CSM_A16_DS_E_8_2
Separate Construction with
Cylindrical 16-dia. Body
• Miniature design of 28.5 mm, the smallest class in the industry.
• Detachable Switch Unit.
• The same contacts can be used for both standard loads and
microloads.
• Easy-to-wire terminal arrangement.
• Certified for EN 60947-5-1.
Refer to Safety Precautions for All Pushbutton Switches/
Indicators and Safety Precautions on page 24.
List of Models
Rectangular
Model
Square
Round
Solder
terminals
A16@-J Series
A16@-A Series
A16@-T Series
PCB
terminals
A16@-J Series
A16@-A Series
A16@-T Series
A16@-J Series
A16@-A Series
A16@-T Series
A16@-J Series
A16@-A Series
A16@-T Series
Voltagereduction
lighting
solder
terminals
Screw-less
clamp
models
1
A16
Model Number Structure
Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton, Lamp
(lighted models only), Case, and Switch. For information on combinations, refer to Ordering Information on
pages 3 to 7.
(1) (2)
(3) (4) (5)
(6)
(7)
A 1 6 5 L - J R M - 24 D - 2
(1) Degree of Protection
Symbol
No symbol
5
Protection
IP40
Oil-resistant
IP65
(2) Lighted/Non-lighted
Symbol
No symbol
L
Type
Non-lighted
Lighted
(3) Shape of Pushbutton
Symbol
J
A
T
(7) Contact Configuration
Symbol
1
2
1P
2P
2S
Type
SPDT
DPDT
SPDT
DPDT
DPDT
Terminal
Solder Terminal
PCB Terminal
Screw-less Clamp
• Only DPDT contacts are available with ScrewLess Clamp.
• Consult your OMRON representative
concerning pricing and delivery timing for PCB
terminals and screw-less clamp connectors.
Shape
(6) Light Source
Rectan2-way guard
gular
(5) Switch Operation
Operating
Rated
Symbol
Type
voltage
voltage
Square 2-way guard
Symbol
Operation
(4) Color of Pushbutton
No symbol
Non-lighted
Projecting
Round
Momentary
M
model
Symbol
Color
5
5 VAC/VDC 6 VAC/VDC
IncanA
Alternate
R
Red
12
descent 12 VAC/VDC 14 VAC/VDC
Momentary-operation:
lamp
Y
Yellow
24
24 VAC/VDC 28 VAC/VDC
Self-resetting
Pure yellow
PY
5D
5 ± 5% VDC
5 VDC
Alternate-operation:
G
Green
12
±
5%
Self-holding
12D
12 VAC/VDC
LED
VAC/VDC
W
White
24 ± 5%
A
Blue
Colored Illumination
24D
24 VAC/VDC
VAC/VDC
PW
Pure white
Unlit
Lit
Voltage Reduction Unit (24-V Built-in LED)
Black (non-lighted
White
Color
B
models only)
Operating
Rated
The built-in
Symbol
Type
• Color illuminated models are also
voltage
voltage
LED
is
colored.
available (see page 8).
100 to 110
100/110
• Order the parts separately.
T1
VAC/VDC
VAC/VDC
LED
200 to 220
200/220
T2
VAC/VDC
VAC/VDC
• Solder terminals are available only with 100-V models.
• The Voltage Reduction Unit is not available for models with
PCB terminals.
• “T2” is available only for the Screw-less Clamp type.
2
A16
Ordering Information
Ordering as a Set .................The model numbers used to order sets of Units are given in the following tables. One set comprises the
Pushbutton, Lamp (lighted models only), Case, and Switch.
Solder Terminal Models
Rectangular Models
IP40
A16@-J
Item
Output
Lighting
LED without
Voltage
Reduction
Unit
SPDT
Incandescent
lamp
Operating
voltage
A16L-J@M-5D-1
A16L-J@A-5D-1
12 VAC/VDC
A16L-J@M-12D-1
A16L-J@A-12D-1
24 VAC/VDC
A16L-J@M-24D-1
A16L-J@A-24D-1
5 VAC/VDC
A16L-J@M-5-1
A16L-J@A-5-1
12 VAC/VDC
A16L-J@M-12-1
A16L-J@A-12-1
A16L-J@M-24-1
A16L-J@A-24-1
24 VAC/VDC
DPDT
Incandescent
lamp
Alternate operation
(Self-holding)
5 VDC
Non-lighted
LED without
Voltage
Reduction
Unit
Momentary operation
(Self-resetting)
A16-J@M-1
A16-J@A-1
5 VDC
A16L-J@M-5D-2
A16L-J@A-5D-2
12 VAC/VDC
A16L-J@M-12D-2
A16L-J@A-12D-2
24 VAC/VDC
A16L-J@M-24D-2
A16L-J@A-24D-2
5 VAC/VDC
A16L-J@M-5-2
A16L-J@A-5-2
12 VAC/VDC
A16L-J@M-12-2
A16L-J@A-12-2
A16L-J@M-24-2
A16L-J@A-24-2
A16-J@M-2
A16-J@A-2
24 VAC/VDC
Non-lighted
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
*1. Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Oil-resistant IP65
Item
Output
Lighting
LED without
Voltage
Reduction
Unit
SPDT
Incandescent
lamp
Operating
voltage
DPDT
Incandescent
lamp
Alternate operation
(Self-holding)
5 VDC
A165L-J@M-5D-1
A165L-J@A-5D-1
12 VAC/VDC
A165L-J@M-12D-1
A165L-J@A-12D-1
24 VAC/VDC
A165L-J@M-24D-1
A165L-J@A-24D-1
5 VAC/VDC
A165L-J@M-5-1
A165L-J@A-5-1
12 VAC/VDC
A165L-J@M-12-1
A165L-J@A-12-1
24 VAC/VDC
A165L-J@M-24-1
A165L-J@A-24-1
A165-J@M-1
A165-J@A-1
5 VDC
A165L-J@M-5D-2
A165L-J@A-5D-2
12 VAC/VDC
A165L-J@M-12D-2
A165L-J@A-12D-2
24 VAC/VDC
A165L-J@M-24D-2
A165L-J@A-24D-2
5 VAC/VDC
A165L-J@M-5-2
A165L-J@A-5-2
12 VAC/VDC
A165L-J@M-12-2
A165L-J@A-12-2
24 VAC/VDC
A165L-J@M-24-2
A165L-J@A-24-2
A165-J@M-2
A165-J@A-2
Non-lighted
LED without
Voltage
Reduction
Unit
Momentary operation
(Self-resetting)
Non-lighted
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
*1. Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Individual models: Refer to pages 9 to 13.
(The Pushbutton, Lamp, Case, and Switch can be ordered
separately.)
■ Ratings: Refer to page 16. ■ Characteristics: Refer to page 16.
■ Accessories: Refer to page 15.
3
A16
Ordering Information
Ordering as a Set ................. The model numbers used to order sets of Units are given in the following tables. One set comprises the
Pushbutton, Lamp (lighted models only), Case, and Switch.
Solder Terminal Models
Square Models
IP40
A16@-A
Item
Output
Lighting
LED without
Voltage
Reduction
Unit
SPDT
Incandescent
lamp
Operating
voltage
DPDT
Incandescent
lamp
Alternate operation
(Self-holding)
5 VDC
A16L-A@M-5D-1
A16L-A@A-5D-1
12 VAC/VDC
A16L-A@M-12D-1
A16L-A@A-12D-1
24 VAC/VDC
A16L-A@M-24D-1
A16L-A@A-24D-1
5 VAC/VDC
A16L-A@M-5-1
A16L-A@A-5-1
12 VAC/VDC
A16L-A@M-12-1
A16L-A@A-12-1
24 VAC/VDC
A16L-A@M-24-1
A16L-A@A-24-1
A16-A@M-1
A16-A@A-1
5 VDC
A16L-A@M-5D-2
A16L-A@A-5D-2
12 VAC/VDC
A16L-A@M-12D-2
A16L-A@A-12D-2
24 VAC/VDC
A16L-A@M-24D-2
A16L-A@A-24D-2
5 VAC/VDC
A16L-A@M-5-2
A16L-A@A-5-2
12 VAC/VDC
A16L-A@M-12-2
A16L-A@A-12-2
24 VAC/VDC
A16L-A@M-24-2
A16L-A@A-24-2
A16-A@M-2
A16-A@A-2
Non-lighted
LED without
Voltage
Reduction
Unit
Momentary operation
(Self-resetting)
Non-lighted
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
*1. Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Oil-resistant IP65
Item
Output
Lighting
LED without
Voltage
Reduction
Unit
SPDT
Incandescent
lamp
Operating
voltage
DPDT
Incandescent
lamp
Alternate operation
(Self-holding)
5 VDC
A165L-A@M-5D-1
A165L-A@A-5D-1
12 VAC/VDC
A165L-A@M-12D-1
A165L-A@A-12D-1
24 VAC/VDC
A165L-A@M-24D-1
A165L-A@A-24D-1
5 VAC/VDC
A165L-A@M-5-1
A165L-A@A-5-1
12 VAC/VDC
A165L-A@M-12-1
A165L-A@A-12-1
24 VAC/VDC
A165L-A@M-24-1
A165L-A@A-24-1
Non-lighted
LED without
Voltage
Reduction
Unit
Momentary operation
(Self-resetting)
A165-A@M-1
A165-A@A-1
5 VDC
A165L-A@M-5D-2
A165L-A@A-5D-2
12 VAC/VDC
A165L-A@M-12D-2
A165L-A@A-12D-2
24 VAC/VDC
A165L-A@M-24D-2
A165L-A@A-24D-2
5 VAC/VDC
A165L-A@M-5-2
A165L-A@A-5-2
12 VAC/VDC
A165L-A@M-12-2
A165L-A@A-12-2
24 VAC/VDC
A165L-A@M-24-2
A165L-A@A-24-2
A165-A@M-2
A165-A@A-2
Non-lighted
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
*1. Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Individual models: Refer to pages 9 to 13.
(The Pushbutton, Lamp, Case, and Switch can be ordered
separately.)
■ Ratings: Refer to page 16. ■ Characteristics: Refer to page 16.
■ Accessories: Refer to page 15.
4
A16
Ordering Information
Ordering as a Set .................The model numbers used to order sets of Units are given in the following tables. One set comprises the
Pushbutton, Lamp (lighted models only), Case, and Switch.
Solder Terminals
Round Models
IP40
A16@-T
Item
Output
Lighting
LED without
Voltage
Reduction
Unit
SPDT
Incandescent
lamp
Operating
voltage
DPDT
Incandescent
lamp
Alternate operation
(Self-holding)
5 VDC
A16L-T@M-5D-1
A16L-T@A-5D-1
12 VAC/VDC
A16L-T@M-12D-1
A16L-T@A-12D-1
24 VAC/VDC
A16L-T@M-24D-1
A16L-T@A-24D-1
5 VAC/VDC
A16L-T@M-5-1
A16L-T@A-5-1
12 VAC/VDC
A16L-T@M-12-1
A16L-T@A-12-1
24 VAC/VDC
A16L-T@M-24-1
A16L-T@A-24-1
A16-T@M-1
A16-T@A-1
5 VDC
A16L-T@M-5D-2
A16L-T@A-5D-2
12 VAC/VDC
A16L-T@M-12D-2
A16L-T@A-12D-2
24 VAC/VDC
A16L-T@M-24D-2
A16L-T@A-24D-2
5 VAC/VDC
A16L-T@M-5-2
A16L-T@A-5-2
12 VAC/VDC
A16L-T@M-12-2
A16L-T@A-12-2
24 VAC/VDC
A16L-T@M-24-2
A16L-T@A-24-2
A16-T@M-2
A16-T@A-2
Non-lighted
LED without
Voltage
Reduction
Unit
Momentary operation
(Self-resetting)
Non-lighted
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
*1. Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Oil-resistant IP65
Item
Output
Lighting
LED without
Voltage
Reduction
Unit
SPDT
Incandescent
lamp
Operating
voltage
DPDT
Incandescent
lamp
Alternate operation
(Self-holding)
5 VDC
A165L-T@M-5D-1
A165L-T@A-5D-1
12 VAC/VDC
A165L-T@M-12D-1
A165L-T@A-12D-1
24 VAC/VDC
A165L-T@M-24D-1
A165L-T@A-24D-1
5 VAC/VDC
A165L-T@M-5-1
A165L-T@A-5-1
12 VAC/VDC
A165L-T@M-12-1
A165L-T@A-12-1
24 VAC/VDC
A165L-T@M-24-1
A165L-T@A-24-1
A165-T@M-1
A165-T@A-1
5 VDC
A165L-T@M-5D-2
A165L-T@A-5D-2
12 VAC/VDC
A165L-T@M-12D-2
A165L-T@A-12D-2
24 VAC/VDC
A165L-T@M-24D-2
A165L-T@A-24D-2
5 VAC/VDC
A165L-T@M-5-2
A165L-T@A-5-2
12 VAC/VDC
A165L-T@M-12-2
A165L-T@A-12-2
24 VAC/VDC
A165L-T@M-24-2
A165L-T@A-24-2
A165-T@M-2
A165-T@A-2
Non-lighted
LED without
Voltage
Reduction
Unit
Momentary operation
(Self-resetting)
Non-lighted
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
R: red, Y: yellow
PY: pure yellow
G: green, A: blue
W: white
PW: pure white
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
B: black *2
*1. Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Individual models: Refer to pages 9 to 13.
(The Pushbutton, Lamp, Case, and Switch can be ordered
separately.)
■ Ratings: Refer to page 16. ■ Characteristics: Refer to page 16.
■ Accessories: Refer to page 15.
5
A16
Ordering Information
Ordering as a Set ................. The model numbers used to order sets of Units are given in the following tables. One set comprises the
Pushbutton, Lamp (lighted models only), Case, and Switch.
Models with Reduced-voltage Lighting and Solder Terminals
A16@-T1
Note: Models with voltage ratings of 200 to 220 VAC/DC (T2 models) are listed with models with screw-less clamp
IP40
Item
Output
SPDT
DPDT
Lighting
Momentary operation
(Self-resetting)
Operating voltage
100/110 VAC/VDC A16L-∆@M-T1-1
LED (with built-in
reduced-voltage
lighting function) 100/110 VAC/VDC A16L-∆@M-T1-2
Alternate operation
(Self-holding)
A16L-∆@A-T1-1
A16L-∆@A-T1-2
Pushbutton color
symbol *
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
PW: pure white
* Enter the desired shape for the Pushbutton in ∆: J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @.
Oil-resistant IP65
Item
Output
SPDT
DPDT
Lighting
Momentary operation
(Self-resetting)
Operating voltage
100/110 VAC/VDC A165L-∆@M-T1-1
LED (with built-in
reduced-voltage
lighting function) 100/110 VAC/VDC A165L-∆@M-T1-2
Alternate operation
(Self-holding)
A165L-∆@A-T1-1
A165L-∆@A-T1-2
Pushbutton color
symbol *
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
PW: pure white
* Enter the desired shape for the Pushbutton in ∆: J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @.
Screw-less Clamp Models
A16@-2S
IP40
Item
Output
Lighting
LED
DPDT
Operating voltage
Momentary operation
(Self-resetting)
Alternate operation
(Self-holding)
5 VDC
A16L-∆@M-5D-2S
A16L-∆@A-5D-2S
12 VAC/VDC
A16L-∆@M-12D-2S
A16L-∆@A-12D-2S
24 VAC/VDC
A16L-∆@M-24D-2S
A16L-∆@A-24D-2S
LED (with built-in 100/110 VAC/VDC A16L-∆@M-T1-2S
reduced-voltage
lighting function) 200/220 VAC/VDC A16L-∆@M-T2-2S
A16L-∆@A-T1-2S
Non-lighted
A16-∆@A-2S
A16-∆@M-2S
A16L-∆@A-T2-2S
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
PW: pure white
B: black *2
*1. Enter the desired shape for the Pushbutton in ∆: J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
Oil-resistant IP65
Item
Output
Lighting
LED
DPDT
Operating voltage
Momentary operation
(Self-resetting)
Alternate operation
(Self-holding)
5 VDC
A165L-∆@M-5D-2S
A165L-∆@A-5D-2S
12 VAC/VDC
A165L-∆@M-12D-2S
A165L-∆@A-12D-2S
24 VAC/VDC
A165L-∆@M-24D-2S
A165L-∆@A-24D-2S
LED (with built-in 100/110 VAC/VDC A165L-∆@M-T1-2S
reduced-voltage
lighting function) 200/220 VAC/VDC A165L-∆@M-T2-2S
A165L-∆@A-T1-2S
Non-lighted
A165-∆@A-2S
A165-∆@M-2S
A165L-∆@A-T2-2S
Pushbutton color
symbol *1
R: red, Y: yellow
PY: pure yellow
G: green, W: white
A: blue
PW: pure white
B: black *2
*1. Enter the desired shape for the Pushbutton in ∆: J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
6
A16
Ordering Information
Ordering as a Set .................The model numbers used to order sets of Units are given in the following tables. One set comprises the
Pushbutton, Lamp (lighted models only), Case, and Switch.
Models with PCB Terminals
A16@-P
IP40
Item
Output
Lighting
LED
Operating voltage
Momentary operation
(Self-resetting)
5 VDC
A16L-∆@M-5D-1P
12 VAC/VDC
A16L-∆@M-12D-1P
24 VAC/VDC
A16L-∆@M-24D-1P
Pushbutton color
symbol *1
SPDT
Non-lighted
LED
A16-∆@M-1P
5 VDC
A16L-∆@M-5D-2P
12 VAC/VDC
A16L-∆@M-12D-2P
24 VAC/VDC
A16L-∆@M-24D-2P
R: red
Y: yellow
PY: pure yellow
G: green
A: blue
W: white
B: black *2
DPDT
Non-lighted
A16-∆@M-2P
Note: Contact your OMRON representative about Selector Switches and Key Selector Switches.
*1. Enter the desired shape for the Pushbutton in ∆: J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
IP65
Item
Output
Lighting
LED
Operating voltage
Momentary operation
(Self-resetting)
5 VDC
A165L-∆@M-5D-1P
12 VAC/VDC
A165L-∆@M-12D-1P
24 VAC/VDC
A165L-∆@M-24D-1P
Pushbutton color
symbol *1
SPDT
Non-lighted
LED
A165-∆@M-1P
5 VDC
A165L-∆@M-5D-2P
12 VAC/VDC
A165L-∆@M-12D-2P
24 VAC/VDC
A165L-∆@M-24D-2P
R: red
Y: yellow
PY: pure yellow
G: green
A: blue
W: white
B: black *2
DPDT
Non-lighted
A165-∆@M-2P
Note: Contact your OMRON representative about Selector Switches and Key Selector Switches.
*1. Enter the desired shape for the Pushbutton in ∆: J (rectangular), A (square), or T (round). Enter the desired color symbol for the Pushbutton in the @.
*2. Black (“B”) Pushbuttons are only available for non-lighted models.
7
A16
Ordering Information
Illumination Only and Colored Illumination for Models with LEDs
With illumination only, the color of the lighted surface is the same when the LED is lit and when it is not lit.
Example: Red Illumination
Not lit
Cap (red)
Red
Legend plate
Dispersion plate (milky white)
Operation Unit
Lit
Red
Reflective plunger
LED lamp (red)
Lamp
With colored illumination, the color of the lighted surface is white when the LED is not lit and the LED emits another color when it is lit.
Example: Red Illumination
Not lit
Cap (translucent)
White
Legend plate
Dispersion plate (milky white)
Operation Unit
Lit
Red
Reflection plunger
LED lamp (red)
Lamp
Ordering: For colored illumination, order the Operation Unit, Case, Lamp, and Socket Unit separately.
Color emitted
when lit
Red
Yellow
Green
Blue
Operation Unit
IP40
A16L-@W
IP65
A165L-@W
Insert one of the following symbols into
the box (@).
J: Rectangular
A: Square
T: Round
Case
IP40
• Momentary: A16-C@M
• Alternate: A16-C@A
IP65
• Momentary: A165-C@M
• Alternate: A165-C@A
Insert one of the following symbols
into the box (@).
J: Rectangular (2-way guard)
A: Square (2-way guard)
T: Round (projected)
Lamp (LED)
Socket Unit
A16-@DSR
A16-@DSY
A16-@DSG
Specify one of the following symbols in the
Refer to page 14. Any
box (@).
Switch can be mount5: 5 VDC
ed.
12: 12 VAC/VDC
24: 24 VAC/VDC
A16-@DA
8
A16
Ordering Information
Ordering Individually .........Pushbuttons, Lamps, Cases, and Switches (Sockets) can be ordered separately. Combinations that are not
available as sets can be created using individual Units. Also, store the parts as spares for maintenance and
repairs.
Pushbutton
Rectangular Models
Square Models
Round Models
Note: Use IP40 Operation Units with IP40 Case
and use IP65 Operation Units with IP65
Case. There is no Legend Plate built into
the Operation Unit.
Case
Note: Operation Unit Sets that combine an Operation Unit and a Case are also
available. (Refer to page 10.)
Lighted Models
Non-lighted Models
Lamp
LED
Incandescent lamp
Socket
Solder terminals
(no transformer)
Lighted/non-lighted
Ordering set combinations: Refer to pages 3 to 7.
Note: Socket Unit Sets that combine a Lamp and a Socket Unit are
also available. (Refer to page 11.)
■ Specifications: Refer to page 16.
■ Accessories, Replacement, and Tools: Refer to page 15.
9
A16
Ordering Information
Units ............................... Select an Operation Unit Set (Operation Unit and Case) and a Socket Unit Set (Lamp and Socket Unit).
Operation Unit
Rectangular, square, round
Lighted Models
Lighted/Non-lighted Model
Socket Unit Set with Voltage-reduction Lighting
Socket Unit Set with Screw-less Clamp Connectors
Lamp
Voltage-reduction
lighting
Lamp
Lighted/Non-lighted
Note: An LED rated 24 VAC/VDC is built-in.
Note: Non-lighted models do not include a Lamp.
Unit Sets ....................... Sets that combine an Operation Unit and a Case.
Operation Unit
Appearance
IP40
Oil-resistant IP65
Classification
Rectangular (2-way guard)
Momentary
Square (2-way guard)
operation
Round (projected)
Rectangular (2-way guard)
Alternate operation Square (2-way guard)
Round (projected)
Rectangular (2-way guard)
Momentary
Square (2-way guard)
operation
Round (projected)
Rectangular (2-way guard)
Alternate operation Square (2-way guard)
Round (projected)
Model
A16-J@M
A16-A@M
A16-T@M
A16-J@A
A16-A@A
A16-T@A
A165-J@M
A165-A@M
A165-T@M
A165-J@A
A165-A@A
A165-T@A
Insert one of the following symbols into the box (@).
Symbol
R
Y
PY
A
W
GY
G
B
Color
Red
Yellow
Pure yellow
Blue
White*
Green
Green
Black
Remarks
LED indicator, incandescent
lamp, or non-lighted
LED only
Incandescent lamp or non-lighted
Non-lighted only
* Use this pushbutton color if the illumination color of the LED is white or pure white.
10
A16
Ordering Information
Unit Sets ....................... Sets that combine a Socket Unit and a Lamp.
Socket Unit Sets with Incandescent Lamps
Appearance
Classification
Standard loads and
microloads
Model
SPDT
A16L-@-1
DPDT
A16L-@-2
SPDT
DPDT
SPDT
DPDT
Model
A16L-Δ-@-1
A16L-Δ-@-2
A16L-Δ-@-1P
A16L-Δ-@-2P
Solder terminals
Socket Unit Sets with LED Lamps
Appearance
Classification
Standard loads and
microloads
Solder terminals
PCB terminals
Socket Unit Set with Voltage-reduction Lighting (Soldered Terminals)
Appearance
Classification
Operating voltage
Model
SPDT
100/110 VAC/VDC
A16L- Δ-T1-1
DPDT
100/110 VAC/VDC
A16L-Δ-T1-2
Standard loads and microloads
Note: An LED rated 24 VAC/VDC is built-in.
Screw-less Clamp Socket Unit Sets
Appearance
Classification
Non-lighted
No voltage-reduction lighting
Standard loads and
microloads
DPDT
Lighted
Voltage-reduc- 100/110 VAC/VDC
tion lighting
Note. 200/220 VAC/VDC
Model
A16-2S
A16L-Δ-@-2S
A16L-Δ-T1-2S
A16L-Δ-T2-2S
Note: The 100-V models and 200-V models an LED rated 24 VAC/VDC is built-in.
Insert symbols in Δ and @.
@
Δ
Symbol
R
Y
G
W
A
Color
Red
Yellow
Green
White
Blue
Symbol
5
12
24
5D
12D
24D
Type
Incandescent
LED
Operating
voltage
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
5 VDC
12 VAC/VDC
24 VAC/VDC
Note: If the Operation Unit is pure yellow (PY), use white (W) for the Socket Unit Set.
11
A16
Ordering Information
Ordering Individually ......... Pushbuttons, Lamps, Cases, and Switches (Sockets) can be ordered separately. Combinations that are not
available as sets can be created using individual Units. Also, store the parts as spares for maintenance and
repairs.
Pushbuttons
LED
Degree of protection
IP40
Rectangular
Oil-resistant IP65
Square
Round
Rectangular
Square
Round
Color
Red
A16L-JR
A16L-AR
A16L-TR
A165L-JR
A165L-AR
A165L-TR
Yellow
A16L-JY
A16L-AY
A16L-TY
A165L-JY
A165L-AY
A165L-TY
Pure yellow
A16L-JPY
A16L-APY
A16L-TPY
A165L-JPY
A165L-APY
A165L-TPY
Green
A16L-JGY
A16L-AGY
A16L-TGY
A165L-JGY
A165L-AGY
A165L-TGY
White*
A16L-JW
A16L-AW
A16L-TW
A165L-JW
A165L-AW
A165L-TW
Blue
A16L-JA
A16L-AA
A16L-TA
A165L-JA
A165L-AA
A165L-TA
* Use this pushbutton color if the illumination color of the LED is white or pure white.
Incandescent Lamps (With the exception of green, the Units are the same as for LEDs.)
Degree of protection
IP40
Rectangular
Square
Oil-resistant IP65
Round
Rectangular
Square
Round
Color
Red
A16L-JR
A16L-AR
A16L-TR
A165L-JR
A165L-AR
A165L-TR
Yellow
A16L-JY
A16L-AY
A16L-TY
A165L-JY
A165L-AY
A165L-TY
Pure yellow
A16L-JPY
A16L-APY
A16L-TPY
A165L-JPY
A165L-APY
A165L-TPY
Green
A16L-JG
A16L-AG
A16L-TG
A165L-JG
A165L-AG
A165L-TG
White
A16L-JW
A16L-AW
A16L-TW
A165L-JW
A165L-AW
A165L-TW
Blue
A16L-JA
A16L-AA
A16L-TA
A165L-JA
A165L-AA
A165L-TA
Non-lighted (Same as Units for incandescent lamps.)
Degree of protection
IP40
Rectangular
Square
Oil-resistant IP65
Round
Rectangular
Square
Round
Color
Red
A16L-JR
A16L-AR
A16L-TR
A165L-JR
A165L-AR
A165L-TR
Yellow
A16L-JY
A16L-AY
A16L-TY
A165L-JY
A165L-AY
A165L-TY
Pure yellow
A16L-JPY
A16L-APY
A16L-TPY
A165L-JPY
A165L-APY
A165L-TPY
Green
A16L-JG
A16L-AG
A16L-TG
A165L-JG
A165L-AG
A165L-TG
White
A16L-JW
A16L-AW
A16L-TW
A165L-JW
A165L-AW
A165L-TW
Blue
A16L-JA
A16L-AA
A16L-TA
A165L-JA
A165L-AA
A165L-TA
Black
A16L-JB
A16L-AB
A16L-TB
A165L-JB
A165L-AB
A165L-TB
Ordering set combinations: Refer to pages 3 to 7.
■ Specifications: Refer to page 16.
■ Accessories, Replacement, and Tools: Refer to page 15.
12
A16
Ordering Information
Ordering Individually .........Pushbuttons, Lamps, Cases, and Switches (Sockets) can be ordered separately. Combinations that are not
available as sets can be created using individual Units. Also, store the parts as spares for maintenance and
repairs.
Lamps
LED
Operating voltage
High brightness
Light color
5 VDC
Red
12 VAC/VDC
A16-5DSR
A16-12DSR
24 VAC/VDC
A16-24DSR
Yellow
A16-5DSY
A16-12DSY
A16-24DSY
Green
A16-5DSG
A16-12DSG
A16-24DSG
White *
A16-5DSW
A16-12DSW
A16-24DSW
Blue
A16-5DA
A16-12DA
A16-24DA
Pure white
A16-5DPW
A16-12DPW
A16-24DPW
Note: 1. If an LED lamp with normal brightness is needed, select a Lamp used in the A3C.
2. For voltage-reduction lighting use the A16-24D@. Only 24 VAC/VDC LED lamps can be used.
* Use the white LED together with white or pure yellow Pushbuttons.
Incandescent Lamp
Appearance
Operating voltage
5 VAC/VDC
12 VAC/VDC
Model
A16-5
A16-12
24 VAC/VDC
A16-24
Cases
Appearance
IP40
Oil-resistant IP65
Ordering set combinations: Refer to pages 3 to 7.
Classification
Rectangular (2-way guard)
Momentary operation Square (2-way guard)
Round (projected)
Rectangular (2-way guard)
Alternate operation
Square (2-way guard)
Round (projected)
Rectangular (2-way guard)
Momentary operation Square (2-way guard)
Round (projected)
Rectangular (2-way guard)
Alternate operation
Square (2-way guard)
Round (projected)
Model
A16-CJM
A16-CAM
A16-CTM
A16-CJA
A16-CAA
A16-CTA
A165-CJM
A165-CAM
A165-CTM
A165-CJA
A165-CAA
A165-CTA
■ Specifications: Refer to page 16.
■ Accessories, Replacement, and Tools: Refer to page 15.
13
A16
Ordering Information
Switches
Appearance
Solder terminal
Classification
Model
SPDT
A16-1
DPDT
A16-2
SPDT
A16-1P
DPDT
A16-2P
DPDT
A16-2S
PCB terminal
Lighted/non-lighted (common use)
Standard load/microload
(common use)
Screw-less Clamp
Switches with Reduced-voltage Lighting
Appearance
Solder terminal
Classification
Model
SPDT
A16-T1-1
DPDT
A16-T1-2
100 V
Standard load/microload
(common use)
Screw-less Clamp
100 V
A16-T1-2S
DPDT
200 V
A16-T2-2S
Note: For voltage-reduction use the A16-24D@. Only 24 VAC/VDC LED lamps can be used.
14
A16
Ordering Information
Accessories, Replacements, and Tools
Accessories
Name
Appearance
Switch Guards
Dust Covers
Panel Plugs
Classification
Model
For rectangular models
A16ZJ-5050
For square and round
models
A16ZA-5050
For rectangular models
A16ZJ-5060
For square models
A16ZA-5060
For round models
A16ZT-5060
For rectangular models
A16ZJ-3003
For square models
A16ZA-3003
For round models
A16ZT-3003
Remarks
Cannot be used with the Dust Cover.
Cannot be used with the Switch Guard.
Can be operated with the Dust Cover attached.
Used for covering the panel cutouts for future panel
expansion.
Protective structure: IP40
Color: Black
Replacements
Name
Appearance
Legend Plates
Rectangular
Color Caps (for
IP40)
Classification
Rectangu- Oil-resistant
lar
IP65
Oil-resistant
Square
IP65
Oil-resistant
Round
IP65
LED lamp/incandescent
lamp/nonlighted
Square
LED lamp
Incandescent lamp/non-lighted
Non-lighted
Round
LED lamp/incandescent
lamp/nonlighted
Color Caps (for
oil-resistant IP65)
LED lamp
Incandescent lamp/non-lighted
Non-lighted
Model
Milky
A16ZJ-5204
Milky
A16ZA-5204
Milky
A16ZT-5204
White
Red
Yellow
Pure yellow
Blue
Green
Green
Black
White
Red
Yellow
Pure yellow
Blue
Green
Green
Black
Remarks
• A single Legend Plate (Milky
white) is included with a standard
model.
A16Z@-5001W
A16Z@-5001R
A16Z@-5001Y
A16Z@-5001PY
A16Z@-5001A
A16Z@-5001GY
A16Z@-5001G
A16Z@-5011B
A16Z@-5101W
A16Z@-5101R
A16Z@-5101Y
A16Z@-5101PY
A16Z@-5101A
A16Z@-5101GY
A16Z@-5101G
A16Z@-5111B
• Insert one of the following letters
into the box (@).
J: Rectangular
A: Square
T: Round
• The Color Cap is usually supplied.
Replace the Cap if the color is to
be changed.
• When using an LED indicator, be
sure to use a Color Cap that
matches the luminescent color of
the LED.
• The materials used for the IP40
and oil-resistant IP65 are different
so be sure to use a Color Cap that
matches the specifications of the
Switch.
Tools
Name
Appearance
Model
Pushbutton Switch
Applicable types
Knob-type
Key-type
EmergenSelector
Selector
cy Stop
Switch
Switch
Switch
Indicator
Remarks
Operation Unit
Extractor
A3PJ-5080
●
—
—
—
●
Convenient for extracting Pushbutton
Switches
Screw Fitting
A16Z-3004
●
●
●
●
●
Convenient for
ganged installation.
Socket Unit Lamp
Extractor
A16Z-5080
●
●
●
●
●
Convenient for extracting the Switch
and Lamps.
15
A16
Specifications
Approved Standard Ratings
UL, cUL (File No. E41515)
TÜV (EN60947-5-1) (Low Voltage Directive)
CCC (GB14048.5)
5 A at 125 VAC, 3 A at 250 VAC (general use)
3 A at 30 VDC (resistive)
3 A at 250 VAC
3 A at 30 VDC
5 A at 125 VAC
3 A at 250 VAC
3 A at 30 VDC
Note: Certification has been obtained for the Socket Unit.
For detailed information on individual products that
have received certification, consult your supplier.
Ratings
Super-bright LED
Contacts
Rated voltage
Resistive load
125 VAC
5A
250 VAC
3A
30 VDC
3A
Rated
voltage
Contact Form
Internal limiting resistor
5 VDC ±5%
Red, yellow, white: 300 Ω
Green, blue, pure white: 160 Ω
12 VAC/VDC
8 mA
12 VAC/VDC ±5%
Red, yellow, white: 1 kΩ
Green, blue, pure white: 910 Ω
24 VAC/VDC ±5% 2.4 kΩ
24 VAC/VDC
Incandescent Lamp
Rated voltage
Rated current
6 VAC/VDC
60 mA
Operating voltage
5 VAC/VDC
14 VAC/VDC
40 mA
12 VAC/VDC
28 VAC/VDC
24 mA
24 VAC/VDC
Voltage-reduction Unit (LED Lamp)
Contact
DPDT
Operating
voltage
5 VDC
Minimum applicable load: 1 mA at 5 VDC
Rated values are obtained from tests conducted under the following
conditions.
1. Load: Resistive load
2. Mounting conditions: No vibration and no shock
3. Temperature: 20 ±2°C
4. Operating frequency: 20 operations/min
Name
Rated
current
NC
Rated voltage
Operating voltage
NO
110 VAC/VDC
100/110 VAC/VDC
(90 to 121 V)
220 VAC/VDC
200/220 VAC/VDC
(180 to 242 V)
COM
Applicable lamp
A16-24DS@
LED Lamp
Characteristics
Socket Unit
Item
Allowable
operating
frequency
Screw-less Clamp
Type
Mechanical
Electrical
Pushbutton Switch
Momentary operation: 120 operations/minute max.
Alternate operation: 60 operations/minute max. *1
100 MΩ min. (at 500V DC)
Contact resistance
100 mΩ max. (initial value)
Between terminals
of same polarity
1,000 VAC, 50/60 Hz for 1 minute
Between terminals
of different polarity
2,000 VAC, 50/60 Hz for 1 minute
Between each terminal and ground
2,000 VAC, 50/60 Hz for 1 minute
Between lamp terminals
1,000 VAC, 50/60 Hz for 1 minute *2
Vibration
resistance Malfunction
Destruction
Shock
resistance Malfunction
Durability
Mechanical
Electrical
Screw-Less Clamp
Recommended wire size
20 operations/minute max. *1
Insulation resistance
Dielectric
strength
Item
Usable wires
and tensile
strength
0.5 mm2 twisted wire or 0.8 mm-dia. solid wire
Twisted
wire
0.3 mm2
0.5 mm2
0.75 mm2
1.25 mm2
Solid
wire
0.5 mm
dia.
0.8 mm
dia.
1.0 mm
dia.
—
10 N
20 N
30 N
40 N
Tensile
strength
10 ±1mm
Length of exposed wire
Compliant standards
JIS C 2811 Terminal Blocks for Industrial Use
Operating Characteristics
10 to 55 Hz, 1.5-mm double amplitude
(malfunction within 1 ms)
2
500 m/s max.
150 m/s2 max. (malfunction within 1 ms)
Momentary operation: 2,000,000 operations min.
Alternate operation: 200,000 operations min. *1
100,000 operations min. *1
Electric shock protection class Class II
PTI (tracking characteristic)
175
Degree of contamination
3 (IEC947-5-1)
Weight
Approx. 10 g (in the case of a lighted
DPDT switch with solder terminals)
Degree of protection
IP40: A16, Oil-resistant IP65: A165 *3
Type
Characteristics
Operating force (OF) max.
Releasing force (RF) min.
Total travel (TT)
Pretravel (PT) max.
Lock travel alternate (LTA) min. *
* Alternate operation models only.
Pushbutton Switch
IP40
Oil-resistant IP65
4.41 N
4.91 N
0.29 N
Approx. 3 mm
2.5 mm
0.5 mm
Ambient operating temperature –10°C to 55°C (with no icing or condensation)
Ambient operating humidity
35% to 85%RH
Ambient storage temperature
–25°C to 65°C (with no icing or condensation)
*1. Set and reset constitute one operation.
*2. With LED and incandescent lamp not mounted.
*3. Degree of protection from the front of the panel.
16
A16
Nomenclature
Model Structure
Pushbutton
Cap
●Color of Pushbutton
· LED/incandescent models
Red, Green, Yellow, White, Blue
· Neon models
Red, Green, White
· Non-lighted models
Red, Green, Yellow, White, Blue, Black
Legend plate
Dispersion plate
●Degree of Protection
IP40/Oil-resistant IP65
Reflective plunger
●Flange Shape
Rectangular (A16@-J)
Square (A16@-A)
Lamp
Round (A16@-T)
Switch
●Switch Ratings
5 A at 125 VAC
3 A at 250 VAC
3 A at 30 VDC
Minimum applicable load: 1 mA at 5 VDC
●Terminal Type
Solder terminals
(tab terminals #110)
PCB terminals
Screw-less Clamp
17
A16
Dimensions
• The Dimension shows 2-switch outputs.
(Unit: mm)
• The lamp terminal is also provided with non-lighted models.
Rectangular
A16@-J
Solder terminals (tab terminals #110)
28.5
9.5
6
• See page 21 for panel cutouts
21.1
10.8
4
Lamp terminal
16
12.2
+0.2
0
dia.
24 min.
18
19 min.
M16×1
Lock ring
Mounting nut
Lamp terminal
2.8
18
4.85 12.4 15.8
15.1
21
Packing (t0.5)
(for oil-resistant IP65 only)
24
Square
A16@-A
Solder terminals (tab terminals #110)
• See page 21 for panel cutouts
28.5
9.5
6
21.1
10.8
4
Lamp terminals
16
12.2
M16×1
Lock ring
Mounting nut
+0.2
0
dia.
19 min.
18
19 min.
Lamp terminals
2.8
18
4.85 12.4 15.8
15.1
15.1
Packing (t0.5)
(for oil-resistant IP65 only)
18
Round
A16@-T
Solder terminals (tab terminals #110)
• See page 21 for panel cutouts
28.5
9.5
6
21.1
10.8
4
Lamp terminals
16
12.2
18 dia. 15.1 dia.
18
M16×1
dia.
19 min.
19 min.
Lock ring
Mounting nut
+0.2
0
Lamp terminals
2.8
18
4.85 12.4 15.8
18
Packing (t0.5)
(for oil-resistant IP65 only)
18
A16
Dimensions
• The Dimension shows 2-switch outputs.
• The lamp terminal is also provided with non-lighted models.
Rectangular
A16@-J@-@P
PCB terminals
• A rectangular model is listed as an example.
(Unit: mm)
• See page 21 for panel cutouts
28.3
26.4
23.1
9.5
6
16 +0.2
0 dia.
21.1
24 min.
10.8
4
9.1 ± 0.05
2.5
18.4 20.4
6.3
14.7 ± 0.05 dia.
0.5
24 min.
5.1 ± 0.05
M16×1
Lock ring
Mounting nut
18
4.85 12.4 18.6
15.1
0.5
21
Packing (t0.5)
(for oil-resistant IP65 only)
24
Rectangular
A16@-J@-T1
Voltage-reduction lighting, solder terminals
(tab terminals #110)
50.1
42.7
28.5
9.5
6
21.1
10.8
Panel Cutouts
4
0.5
Direction-indication arrow
0.5
16 +0.2
0 dia.
12.2
9.8
18
24 min.
0.5
Marking face
M16×1
Lock ring
23 min.
Mounting nut
Switch
(22.4)
20.6
15.1
18
8.8 16.6
2.8 12.4
Packing (t0.5)
(for oil-resistant IP65 only)
21
24
Rectangular
A16@-J@-2S, T1-2S, T2-2S
Screw-less Clamp
2.8
2
9.5
6
48.9
Panel Cutouts
10.8
4
16
24
+0.2
0
dia.
25 min.
23.9
M16×1
Switch dismounting lever
Lock ring
Mounting nut
33 min.
(31.7) 27.4
18 15.1
21
24
Lamps
LED
Packing (t0.5)
(for oil-resistant IP65 only)
Incandescent Lamp
A16-5/-12/-24
A16-5D@/-12D@/-24D@
12 max.
23.5
4
12 max.
0.5 dia.
0.25
6 dia.
2.8
*
4
Cathode (-)
6 dia.
2.54
Anode (+)
* The voltage display surface is the same color as the illumination
color. The opposite surface is light gray.
(For pure white, the entire surface is light gray.)
19
A16
Dimensions
(Unit: mm)
Accessories, Tools, and Components
Extractor
A3PJ-5080
20
5
15
10
50
25
Legend Plates
A16ZJ-520@
A16ZA-520@
18.9
12.9
A16ZT-520@
12.9
13.4 dia.
12.9
0.6
0.6
Screw Fitting
A16Z-3004
12.9 dia.
0.6
Note: 1. The panel is 0.6 mm thick.
2. The panel is made of the materials listed in the following
table.
60
2
Degree of
protection
Color
IP40
Milky
18 dia.
Polyalylate resin
IP65
Transparent
Materials
IP40
Polycarbonate resin
IP65
Polyalylate resin
Panel Plugs (Black Resin)
Select the Plug that fits the panel design and
mount from the front of the Panel. Panel cutouts
are the same as those for Switches.
Protective structure: IP40
Color: Black
Rectangular
Square
A16ZJ-3003
24
A16ZT-3003
18
18 dia.
18
Lock Ring
Round
A16ZA-3003
18
Rough surface
15.8 ± 0.1 dia.
@12
17.9 ± 0.1
Rough surface
2 +0.2
0
0
15 -0.1
dia.
t=1
17.9 ± 0.1
Socket Unit Lamp Extractor
A16Z-5080
10
2
80
8
12
20
20
A16
Dimensions
(Unit: mm)
Panel Cutouts
Solder Terminals and Screw-less Clamp Connectors
Rectangular A16@-@J/M16@-@J
Square A16@-A/M16@-A
Round A16@-T/M16@-T
(Top View)
16 +0.2
0 dia.
PCB Terminals
Rectangular A16@-J/M16@-J
(Top View)
24 min.
(25 min.)
16
+0.2
0
(Top View)
16 +0.2
0 dia.
dia.
Square A16@-A/M16@-A
Round A16@-T/M16@-T
(Top View)
24 min.
19 min.
(25 min.)
16
+0.2
0
dia.
19 min.
(25 min.)
9.1 ± 0.05
19 min.
(33 min.)
19 min.
(33 min.)
Note:• Make sure the thickness of the mounting panel is between 0.5 and 3.2
mm. If, however, a Switch Guard or Dust Cover is used, the thickness
of the mounting panel must be between 0.5 and 2 mm.
• If the panel is to be finished with coating, etc., make sure that the panel
meets the specified dimensions after coating.
• Figures in parentheses are for Screw-less Clamp Connectors.
14.7 ± 0.05 dia.
19 min.
(33 min.)
24 min.
5.1 ± 0.05
Note:• Ensure that the variation in the distance between the centers of
neighboring mounting holes is less than ±0.1 mm.
• Make sure the thickness of the mounting panel is between 0.5 and 3.2
mm. If, however, a Switch Guard or Dust Cover is used, the thickness
of the mounting panel must be between 0.5 and 2 mm.
• If the panel is to be finished with coating, etc., make sure that the panel
meets the specified dimensions after coating.
Terminal Arrangement
Models without Reduced-voltage Lighting (Non-lighted Pushbutton Switches are also provided with lamp terminals.)
Solder Terminals
Lighted SPDT Switches
Lighted DPDT Switches
Terminal Arrangement
(Bottom View)
Dimensions of
Terminal Holes
2.6
0.9
1.5
2.8
NC
Dimensions of
Terminal Holes
2.6
0.9
COM
12.2
NC
L-
NO
7.4
Lamp terminal
Terminal Arrangement
(Bottom View)
7.4
SW1
18
Note: The L+ is not shown on the Switch.
1.5
2.8
12.2
Lamp terminal
L-
NC
NO
NO
COM
COM
SW1
SW2
18
Note: The L+ is not shown on the Switch.
21
A16
Dimensions
(Unit: mm)
PCB Terminals (Lamp terminals are also present on non-lighted models.)
Lighted SPDT Switches
Lighted DPDT Switches
Terminal Arrangement
(Bottom View)
Terminal Arrangement
(Bottom View)
Model, rating, and lot
number indication
5.3
NC
3.5
5.3
L-
NC
COM
SW 1
0.8
0.8
4.85
2.7
NO
COM
COM
SW 1
SW 2
12.4
12.4
PCB Cutouts
(Bottom View)
NC
NO
4.85
2.7
Lamp terminal (t=0.5)
18.6
Lamp terminal (t=0.5)
L-
3.5
1.5
NO
1.5
Side with TOP indicated
Dimensions of
PCB Terminals
Side with TOP indicated
Dimensions of
PCB Terminals
Side with TOP indicated
PCB Cutouts
(Bottom View)
A ± 0.1
18.6
Side with TOP indicated
12.4 ± 0.05
12.4 ± 0.05
20 ± 0.1 4.85 ± 0.05
20 ± 0.1 4.85 ± 0.05
L ± 0.1
Five, 1 dia.
6.3 ± 0.05
A = 24 min.: Rectangular
A = 21 min.: Square or round
L = 24 min.
Use a PCB with a thickness of 1.6 mm.
6.3 ± 0.05
A ± 0.1
L ± 0.1
6.3 ± 0.05
Two, 5 dia.
Two, 5 dia.
A = 24 min.: Rectangular
A = 21 min.: Square or round
L = 24 min.
Use a PCB with a thickness of 1.6 mm.
Note: Secure the panel to the board using stud bolts
if force will be applied to the board after wiring.
Note: Secure the panel to the board using stud bolts
if force will be applied to the board after wiring.
Eight, 1 d
Terminal Arrangement
Voltage-reduction Lighting (Lamp terminals are also present on non-lighted models.)
Solder Terminals
Screw-Less Clamps
DPDT lighted models
DPDT lighted models
Black (Release button)
(Bottom view)
Side with direction arrow
Side indicating TOP
Red (Release button)
Red (Release button)
White (Release button)
White (Release button)
Black (Release button)
Black (Release button)
NC2
NC
L
NO
NC
NO
Black (Release button)
L
C
Black (Release button)
C
-
NC1
NO1
NO2
C2
+
C1
C2
+
C1
12-3.1 dia. (Insertion hole)
Red (Release button)
• The voltage-reduction circuit is built in.
• Voltage-reduction lighting models with Screw-Less Clamps (A16L-@T1-2S, A16L-@T2-2S)
incorporate voltage-reduction circuits.
22
A16
Dimensions
(Unit: mm)
Accessory Dimensions Mounted
Dimensions with Switch Guard Installed
Square
A16ZA-5050
Rectangular
A16ZJ-5050
24
18
Torsion spring
18.1
Torsion spring
18.1
23.5
23.5
10.5
10.5
Holder (black)
Guard (transparent)
Panel Cutout (Top View)
24.5 min.
Holder (black)
Guard (transparent)
Panel Cutout (Top View)
19 min.
16 +0.2
0 dia.
16 +0.2
0 dia.
19.6
27
13
13
X
X
28 min.
Note: This example is for when X is
4.5 mm.
If X is not required, the
Switches can be mounted with
a minimum vertical installation
pitch of 24 mm min.
19.6
27
Note: This example is for when X is 4.5
mm.
If X is not required, the Switches
can be mounted with a minimum
vertical installation pitch of 24 mm
min.
If PCB terminals are used, provide X
must be 24 mm or larger.
28 min.
Dust Covers
Rectangular
A16ZJ-5060
Cover B (transparent)
Cover A (black)
Panel Cutouts
16
+0.2
0
dia.
31 min.
24
25 min.
30
19.6
13.8
Square
A16ZA-5060
27
Cover B (transparent)
Cover A (black)
Panel Cutouts
16
+0.2
0
+0.2
0
dia.
dia.
25 min.
24
25 min.
24
13.8
Round
A16ZT-5060
19.6
27
Cover B (transparent)
Cover A (black)
Panel Cutouts
25 min.
16
25 min.
24 dia.
13.8
19.6
27
23
A16
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches/Indicators.
Do not apply a voltage between the incandescent
lamp and the terminal that is greater than the rated
voltage. If the incandescent lamp is broken, the
operating part may pop out.
Always turn OFF the power and wait for 10 minutes
before replacing the incandescent lamp. If the lamp is
replaced immediately after the power is turned OFF,
the remaining heat may cause burns.
Precautions for Correct Use
Mounting
• Always make sure that the power is turned OFF before mounting,
removing, or wiring the Switch, or performing maintenance.
• Do not tighten the mounting nut more than necessary using tools
such as pointed-nose pliers. Doing so will damage the mounting
nut.
The tightening torque is 0.29 to 0.49 N·m.
Using the Microload
• Insert a contact protection circuit, if necessary, to prevent the
reduction of life expectancy due to extreme wear on the contacts
caused by loads where inrush current occurs when the contact is
opened and closed.
• The A16 allows both a standard load (125 V at 5A, 250 V at 3 A)
and a microload. If a standard load is applied, however, the
microload area cannot be used. If the microload area is used with a
standard load, the contact surface will become rough, and the
opening and closing of the contact for a microload may become
unreliable.
• The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60) (conforming to JIS C5003).
The equation, λ 60 = 0.5 × 10-6/operations indicates that the
estimated malfunction rate is less than 1/2,000,000 operations with
a reliability level of 60%.
Voltage (V)
WARNING
Wiring
• Solder terminals and quick-connect terminals (#110) are commonly
used for terminals.
• Be sure to use electrical wires that are a size appropriate for the
applied voltage and carry current (conductor size is 0.5 to 0.75
mm2). Perform soldering according to the conditions provided
below. If the soldering is not properly performed, the lead wires will
become detached, resulting in short-circuits.
1. Hand soldering: 350°C, within 3 s
2. Dip soldering: 350°C, within 3 s
Wait for one minute after soldering before exerting any external
force on the solder.
• Use non-corrosive resin fluid as the flux.
• Make sure that the electric cord is wired so that it does not touch
the Unit. If the electric cord touches the Unit, then electric wires with
a heat resistance of 100°C min. must be used.
• After wiring the Switch, maintain an appropriate clearance and
creepage distance.
0.15 mA
30
24
Microload area
12
Invalid
area
5
1
10
100
1,000
Current (mA)
LED
• The LED current-limiting resistor is built-in, so external resistance
is not required.
Rated voltage
5 VDC
Operating Environment
• This Switch is intended for indoor use only. Using the Switch
outdoors will cause the Switch to fail. If IP40 models are used in
locations subject to dust, metallic particles, or oil, be careful that
none of these penetrates the Switch.
• The IP65 model is designed with a degree of protection so that it
will not sustain damage if it is subjected to water from any direction
to the front of the panel.
• Do not use the Switch submersed in oil or water, or in locations
continuously subject to splashes of oil or water. Doing so may result
in oil of water entering the Switch.
1 mA
0
0.1
12 VAC/VDC
24 VAC/VDC
Internal limiting resistor
Red, yellow, white: 300 Ω
Green, blue, pure white: 160 Ω
Red, yellow, white: 1 kΩ
Green, blue, pure white: 910 Ω
2.4 kΩ
Others
• The oil-resistant IP65 uses NBR rubber and is resistant to general
cutting oil and cooling oil. Some particular oils cannot be used with
the oil-resistant IP65, however, so contact your OMRON
representative for details.
• The durability of the Switch depends in the switching conditions.
Always test the Switch under actual application conditions to
confirm applicability and use the Switch only for the number of
switching operations that will not affect performance.
Continuing to use the Switch with degraded performance will
eventually result insulation faults between circuits, burning of the
Switch, or other failures.
• If the panel is to be finished with coating, etc., make sure that the
panel meets the specified dimensions after the coating.
• Do not subject the Switch to extreme shock or vibration. Doing so
will cause malfunctions and damage to the Switch.
• Do not let sharp objects come into contact with the Switches that
are made of resin. Doing so will damage the Switches, causing
scratches on the outside of the operating parts, and malfunction.
When handling the Switches, do not throw or drop them.
24
A16
• Rubber is used inside IP65 models. Do not allow the rubber to
become scratched or foreign matter to become attached to the
rubber.
Scratches and foreign matter will degrade the waterproofing, and
the Switch may fail operate correctly.
Do not allow the Switch
to drop and hit the
ground.
Precautions
1. The mounting panel thickness must be 0.5 to 3.2 mm.
2. The mounting ring must be tightened to a torque 0.29 to 0.49 N·m.
3. The procedure for making the mounting hole for the screw-less
clamp connector is described on page 21. A mounting dimension
of at least 33 mm is required, however, because the Switch is
removed with the screw-less clamp connector mounted to the
panel. If Switches are mounted side-by-side separated by less
than the specified distance, it may not be possible to remove the
Switch.
4. Be sure to mount the Case to the Switch with the correct
orientation. Mount with the dimple on the Case facing in the same
direction as the side of the Switch with the direction arrow or the
word TOP.
Direction arrow
dimple
Case
Switch
TOP mark
Do not place or drop
heavy objects on the
Switch.
dimple
Case
Do not operate the Switch
with hard or sharp objects.
Hammer
Screwdriver
Screw-less Clamp Wiring Procedure
Connecting Wires
Switch
5. Bend the end of the wire if braided wire is used with the screwless clamp connector.
6. When wiring, insert the wire until it comes into contact with
something. After wiring is completed, pull on the wires to confirm
that they are connected securely.
7. After wiring, ensure that continuous pressure is not applied to the
terminals.
8. Refer to internal connection diagrams and confirm the terminal
numbers before wiring.
1. Strip the wires for 10 mm (allowable range: 10± 1 mm).
2. If braided wire is used, twist the wire to straighten it out.
3. Insert the wire into the insertion hole while pressing the release
button at the side of the hole. (Using a precision screwdriver is
recommended.)
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
locked.
Removing Wires
1. Remove wires by pulling them while pressing the release button.
Note: When reusing wires that have already been locked one, cut off the end of
the wire and strip the wire again before using.
25
A16
Panel Mounting
Removing the Switch Unit
After mounting the Pushbutton Unit (i.e., the Pushbutton and the
Case) to the panel, snap in the Switch Unit (i.e., the Switch and the
Lamp) from the back of the panel.
• Grip the part between the Switch holder of the Case and the Switch
Unit using the A16Z-5080 Extractor, and pull to remove the Switch
Unit.
Mounting to the Panel
• Insert the Pushbutton Unit into the front of the panel, and fix the lock
ring and mounting nut from the terminal side.
• Make sure that the lock ring is aligned with the thread of the Case
and the edge of the lock ring is touching the panel.
• Tighten the mounting nuts to a torque of 0.29 to 0.49 N·m.
Panel
Mounting nut
Case
Thread
A16Z-5080 Extractor
Note: Refer to page 21 for PCB terminals.
Engraving
Engraving the Legend Plate
Lock ring
Edge
• The characters must not be engraved deeper than 0.4 mm.
• Apply an alcohol-based paint coating, such as melamine,
phthalate, or acrylic resin paint coating.
Mounting the Switch Unit
• Snap on the Switch Unit to the Pushbutton Unit.
• Make sure that the Switch Unit has the correct orientation when
snapping it onto the Case. Align the dimple on the Case with the
groove between the case guards on the NC terminal side of the
Switch Unit in the way shown below, and push the Switch Unit into
the Case until it clicks into place. Confirm that the Switch Unit is
securely in place before using.
Mounting and Replacing the Pushbutton
Removing and Mounting the Pushbutton
(1) Remove the Pushbutton as shown in the following diagram. If the
Pushbutton cannot be removed by hand, use the A3PJ-5080
Extractor.
Groove between case guards
Pushbutton
(2) When mounting the Operation Unit to the Case, press the entire
surface of the Operation Unit to surface A of the Case as shown
in the following diagram.
dimple
NC terminal
Operation Unit
Case
Surface A
26
A16
Removing the Lamp
Installing the Lamp
• When mounting the Lamp, make sure it is facing the direction
shown in the following diagram. Insert the Lamp while matching the
protruding part of the Lamp and the small guides on the outer
surface of the Case.
(1) Removing from the Pushbutton End
Lamp
Grip the Lamp with the
A16Z-5080 Extractor
and pull to remove.
Protruding part
• The Lamp can be mounted from the Pushbutton end by using the
A16Z-5080 Extractor.
The lamp can be mounted by following the opposite procedure for
removing the Lamp.
(2) Removing from the Switch End
The Lamp can be removed by hand once the Switch is removed
using the A16Z-5080 Extractor.
Mounting the A16Z Dust Cover
Cover B
(transparent)
Pushbutton Unit
Set
A16ZJ-5060
1.
2.
3.
4.
Separate the Dust Cover into 2 parts: cover A and cover B.
Insert the Case (Pushbutton Unit) into cover A.
Mount these parts together onto the panel.
From the back of the panel, mount the lock ring and secure with the
mounting nut.
5. Insert cover B into cover A. Ensure that the entire perimeter of cover B
is securely attached to cover A by pressing in different directions.
6. Mount the Switch Unit to the Case.
Note: Recommended panel thickness: 0.5 to 2 mm.
Cover A
(black)
Panel
Lock ring
Mounting nut
Switch Unit
Mounting the A16Z Switch Guard
Switch Guard
Panel
Pushbutton Unit
1. Insert the Case (Pushbutton Unit) into the Switch Guard.
2. Mount these parts together onto the panel.
3. From the back of the panel, mount the lock ring and secure with the
mounting nut.
4. Attach the Switch Unit to the Case.
Note: Recommended panel thickness: 0.5 to 2 mm.
Lock ring
Mounting nut
Switch Unit
27
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
Similar pages