SL Power CINT1200A2475K01 200w single output industrial sery Datasheet

CINT1200
200W Single Output
Industrial Series
Features
3” x 5” x 1.3” Package
200W with 100LFM Air
180W Convection Cooled
Class B Conducted EMI
Fits 1U Applications
Universal Input 90-264 Vac
Approved to CSA/EN/IEC/UL60950-1, 2nd
Edition
Efficiency 90% typical
3 Year Warranty
RoHS Compliant
Description
A power-packed, highly efficient AC to DC power supply designed for industrial and ITE applications. These models
provide 180 Watts convection cooled, 200 Watts with moving air. The small heat footprint allows simple thermal design of
systems which use this product. All models are CE marked to low voltage directive and approved to ITE standards of
EN60950-1, 2nd edition.
Model Selection
Model
Number
Volts
Minimum
Load
Ripple &
Noise**
Total
Regulation
OVP
Threshold***
CINT1200A1275K01
12V
16.7A
15.0A
0A
120mV pk-pk
±3%
14.0 ± 1.1V
CINT1200A1575K01
15V
13.3A
12.0A
0A
150mV pk-pk
±3%
18.5 ± 1.2V
CINT1200A1875K01
18V
11.1A
10.0A
0A
180mV pk-pk
±3%
21.5 ± 2.0V
CINT1200A2475K01
24V
8.33A
7.50A
0A
240mV pk-pk
±3%
29.0 ± 2.5V
CINT1200A2875K01
28V
7.14A
6.40A
0A
280mV pk-pk
±3%
33.5 ± 2.5V
CINT1200A3275K01
32V
6.25A
5.62A
0A
320mV pk-pk
±3%
36.0 ± 3.0V
CINT1200A3675K01
36V
5.55A
5.00A
0A
360mV pk-pk
±3%
41.0 ± 3.0V
CINT1200A4875K01
48V
4.17A
3.75A
0A
480mV pk-pk
±3%
56.0 ± 3.0V
Notes:
Output Current
w/100LFM air
Convection*
* Total convection power is 180 Watts.
** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors.
General Specifications
AC Input
Input Current
www.slpower.com
100-240Vac, ±10%, 47-63Hz, 1∅
120–370Vdc
Turn On Time
Less than 3 sec. @115Vac, Full Load
115Vac: 1.8A, 230Vac: 0.9A
Hold-up Time
16mS at 200W, 120Vac/60Hz
CINT1200 REV 1.4 12-JUNE-13
1
CINT1200
200W Single Output
Industrial Series
Specifications (continued)
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
Output Power
Transient
Response
Ripple and Noise
Output Voltage
264Vac, cold start: will not exceed 55A
F1, F2: 3.15A, 250Vac fuses provided on all
models
<500µA@264Vac, 60Hz, NC; <1mA SFC
Overtemperature
Protection
Overload Protection
Short Circuit
Protection
Overvoltage
Protection
88% typical
200W continuous, with 100 lfm airflow, 180W
convection cooled – See chart for specific
voltage model ratings.
Switching Frequency
500µS typical, return to 0.5% of nominal, 50%
load step. ∆i/∆t: <0.2A/µS. Max Voltage
Deviation = 3%
Isolation
Hiccup Mode, auto recovery.
OVP latch, see models chart for trip range.
PFC: Fixed, 65kHz
Main Converter: Variable 35-200kHz, 6570kHz at full load.
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vac
Operating
Temperature
-10°C to +70°C
Start Up at -40°C, full load
See chart
Temperature
Derating
Derate output power linearly above 50°C to
50% at 70°C
Fixed Output
Storage Temperature
Minimum Load
Not required
Altitude
Total Regulation
+/- 3% combined line, load and initial setting.
Vibration
Operating: 0.003g²/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g²/Hz, 5.0grms overall,
3 axes, 1 hr/axis
Weight
120 to 150% of rating, Hiccup Mode
0.5%rms, 1% pk-pk, see chart.
Voltage
Adjustability
Dimensions
Sensing transformer temperature, 165°C at
full load, latching type, requires input power
recycling to reset.
W: 3.0” x L: 5.0” x H: 1.3”
Relative Humidity
Shock
Safety Standards
MTBF
325g
-40°C to +85°C
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
401,000 hours, 25°C, 110Vac
Output vs. Temperature Derating Curve
180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70°C.
www.slpower.com
CINT1200 REV 1.4 12-JUNE-13
2
CINT1200
200W Single Output
Industrial Series
EMI/EMC Compliance
Conducted Emissions
EN55011/22 Class B, FCC Part 15, Subpart B, Class B
Radiated Emissions
EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin
Static Discharge Immunity
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3, 3V/m.
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz
Line Surge Immunity
EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity
EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m
Voltage Dip Immunity
EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; Performance
Criteria A, A, & A at 70% load.
Line Harmonic Emissions
EN61000-3-2, Class A, B, C, & D
Flicker Test
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Notes:
[4] x 0.156
4 PLCS
MTG
HOLES
1. All dimensions in inches (mm), tolerance
is +/-0.000”.
2. Mounting holes should be grounded for
EMI purposes.
3. FG is safety ground connection.
4. The power supply requires mounting on
metal standoffs 0.20” (5mm) in height, min.
Connector Information
Input Connector
J100
Ground
(FG)
DC Output Connector
J300
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
0.25” FASTON TAB
Term. 1,2,3: RTN
Term. 4,5,6: +Vout
Mating Connector:
AMP Molex 640250-3
Pins: 640252-2
Mating Connector:
Molex 190020001
Mating Connector:
AMP 640250-6
Pins: 640252-2
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
CINT1200 REV 1.4 12-JUNE-13