Click on Series name for product info on aimtec.com Series AM40UW-IZ 40Watt | DC-DC Converter FEATURES: • • • • • Models Single output Model AM40UW-2403SIZ AM40UW-2405SIZ AM40UW-2412SIZ AM40UW-2415SIZ AM40UW-2424SIZ AM40UW-4803SIZ AM40UW-4805SIZ AM40UW-4812SIZ AM40UW-4815SIZ AM40UW-4824SIZ AM40UW-2403SH30IZ AM40UW-2405SH30IZ AM40UW-2412SH30IZ AM40UW-2415SH30IZ AM40UW-2424SH30IZ AM40UW-4803SH30IZ AM40UW-4805SH30IZ AM40UW-4812SH30IZ AM40UW-4815SH30IZ AM40UW-4824SH30IZ Models Dual output Model AM40UW-2405DIZ AM40UW-2412DIZ AM40UW-2415DIZ AM40UW-4805DIZ AM40UW-4812DIZ AM40UW-4815DIZ AM40UW-2405DH30IZ AM40UW-2412DH30IZ AM40UW-2415DH30IZ AM40UW-4805DH30IZ AM40UW-4812DH30IZ AM40UW-4815DH30IZ Ultra-Wide Input 4:1 Range 1500 & 3000 VDC Isolation Efficiency up to 83% Regulated Output Soft Start • • • • Adjustable Output Voltage Remote ON/OFF Function Over Load, Voltage & Short Circuit Protection Operating temperature -40oC to + 75oC Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) 9-36 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 18-75 3.3 5 12 15 24 3.3 5 12 15 24 7 7 3 2.3 1.5 7 7 3 2.3 1.5 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 82 82 82 82 82 83 83 83 83 83 Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) 9-36 9-36 9-36 18-75 18-75 18-75 ±5 ±12 ±15 ±5 ±12 ±15 ±3.5 ±1.5 ±1.15 ±3.5 ±1.5 ±1.15 3000 3000 3000 3000 3000 3000 80 80 80 81 81 81 9-36 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 18-75 9-36 9-36 9-36 18-75 18-75 18-75 3.3 5 12 15 24 3.3 5 12 15 24 ±5 ±12 ±15 ±5 ±12 ±15 7 7 3 2.3 1.5 7 7 3 2.3 1.5 ±3.5 ±1.5 ±1.15 ±3.5 ±1.5 ±1.15 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 82 82 82 82 82 83 83 83 83 83 80 80 80 81 81 81 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 1 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40UW-IZ 40Watt | DC-DC Converter Input Specifications Parameters Nominal Voltage range 24 48 Filter Absolute Maximum Rating Isolation Specifications Parameters Parameters 1500 or 3000 >1000 Conditions Voltage accuracy Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Voltage adjustment range Minimum Load Current General Specifications Parameters Conditions Typical Typical 100% load F 051e R12.B Maximum Units % % % of Vin % % %/oC mV p-p % p-p Vout % % of Max Maximum Units KHz o C o C o C o C 280 % RH g o C uS Parameters CE, (on 1500 VDC Isolation models only) EMI - Conducted and radiated emission www.aimtec.com VDC MOhm 95 Nickel – coated Copper with nonconductive base 65 2.00 x 2.00 x 0.40 inches 50.81 x 50.81 10.20 mm >1 500 000 hrs ( MIL-HDBK-217 F at +25 oC) 50% load step change VDC Units 250 -40 to +85 -55 to +115 100 45 Free air convection See chart below Safety & EMC Specifications Standards VDC Maximum ±2 Zener diode clamp >110 FL Continuous Auto-Restart ±0.5 Iout=25% to 100% ±0.5 Iout=25% to 100% ±2 ±0.05 20MHz Bandwidth (5 & 3.3Vout) 80 All other output models 1 ±5 25 Ripple & Noise Agency approvals Typical 3 sec 500VDC Output Specifications Units 50 100 ON –TTL High or Open ; OFF – TTL Low or short Conditions Tested I/O voltage Resistance Maximum 9-36 18-75 π(Pi) Network 24 48 On/Off control Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Typical Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Tel: +1 514 620 2722 2 of 5 EN55022: 2010, class A EN55024: 2010 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-6 IEC 61000-4-8 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40UW-IZ 40Watt | DC-DC Converter Pin Out Specifications Pin 1000 & 3000VDC Single +V Input -V Input On/Off Control No pin +V Output -V Output Trim 1 2 3 4 5 6 7 Dual +V Input -V Input On/Off Control +V Output Common -V Output Trim Dimensions 10.16 (0.40) Bottom View 5 2 6 3 7 10.16 (0.40) 50.80 (2.00) 5.08 (0.20) 1 10.16 (0.40) 22.86 (0.90) 4 10.16 (0.40) 50.80 (2.00) 45.70 (1.80) Printed Face Dimensions mm (inch) Case Tolerance: ±0.25mm (±0.02inch) Pin Length Tolerence: ±0.05mm (±0.002inch) 5.60 (0.22) Side View 1.00 (0.04) Trimming www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40UW-IZ 40Watt | DC-DC Converter Derating Free Air Convection 45 º C Output Power (%) 100 80 Safe Operating Area 60 40 35 20 75 0 - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C Control ON/OFF pin connection example Single Output Dual Output www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40UW-IZ 40Watt | DC-DC Converter Digital Control Circuit: Vpeak Control Voltage On / Off Control 0.5mA NPN 0V Ra = Vpeak – 0.6 DC/DC Converter -V input 0.5mA NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only