AIMTEC AM40UW-4805SH30IZ 40watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM40UW-IZ
40Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
Models
Single output
Model
AM40UW-2403SIZ
AM40UW-2405SIZ
AM40UW-2412SIZ
AM40UW-2415SIZ
AM40UW-2424SIZ
AM40UW-4803SIZ
AM40UW-4805SIZ
AM40UW-4812SIZ
AM40UW-4815SIZ
AM40UW-4824SIZ
AM40UW-2403SH30IZ
AM40UW-2405SH30IZ
AM40UW-2412SH30IZ
AM40UW-2415SH30IZ
AM40UW-2424SH30IZ
AM40UW-4803SH30IZ
AM40UW-4805SH30IZ
AM40UW-4812SH30IZ
AM40UW-4815SH30IZ
AM40UW-4824SH30IZ
Models
Dual output
Model
AM40UW-2405DIZ
AM40UW-2412DIZ
AM40UW-2415DIZ
AM40UW-4805DIZ
AM40UW-4812DIZ
AM40UW-4815DIZ
AM40UW-2405DH30IZ
AM40UW-2412DH30IZ
AM40UW-2415DH30IZ
AM40UW-4805DH30IZ
AM40UW-4812DH30IZ
AM40UW-4815DH30IZ
Ultra-Wide Input 4:1 Range
1500 & 3000 VDC Isolation
Efficiency up to 83%
Regulated Output
Soft Start
•
•
•
•
Adjustable Output Voltage
Remote ON/OFF Function
Over Load, Voltage & Short Circuit Protection
Operating temperature -40oC to + 75oC
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
3.3
5
12
15
24
3.3
5
12
15
24
7
7
3
2.3
1.5
7
7
3
2.3
1.5
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
82
82
82
82
82
83
83
83
83
83
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±3.5
±1.5
±1.15
±3.5
±1.5
±1.15
3000
3000
3000
3000
3000
3000
80
80
80
81
81
81
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
9-36
9-36
9-36
18-75
18-75
18-75
3.3
5
12
15
24
3.3
5
12
15
24
±5
±12
±15
±5
±12
±15
7
7
3
2.3
1.5
7
7
3
2.3
1.5
±3.5
±1.5
±1.15
±3.5
±1.5
±1.15
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
82
82
82
82
82
83
83
83
83
83
80
80
80
81
81
81
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40UW-IZ
40Watt | DC-DC Converter
Input Specifications
Parameters
Nominal
Voltage range
24
48
Filter
Absolute Maximum Rating
Isolation Specifications
Parameters
Parameters
1500 or 3000
>1000
Conditions
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Voltage adjustment range
Minimum Load Current
General Specifications
Parameters
Conditions
Typical
Typical
100% load
F 051e R12.B
Maximum
Units
%
%
% of Vin
%
%
%/oC
mV p-p
% p-p Vout
%
% of Max
Maximum
Units
KHz
o
C
o
C
o
C
o
C
280
% RH
g
o
C
uS
Parameters
CE, (on 1500 VDC Isolation models only)
EMI - Conducted and radiated emission
www.aimtec.com
VDC
MOhm
95
Nickel – coated Copper with nonconductive base
65
2.00 x 2.00 x 0.40 inches
50.81 x 50.81 10.20 mm
>1 500 000 hrs ( MIL-HDBK-217 F at +25 oC)
50% load step change
VDC
Units
250
-40 to +85
-55 to +115
100
45
Free air convection
See chart below
Safety & EMC Specifications
Standards
VDC
Maximum
±2
Zener diode clamp
>110 FL
Continuous
Auto-Restart
±0.5
Iout=25% to 100%
±0.5
Iout=25% to 100%
±2
±0.05
20MHz Bandwidth (5 & 3.3Vout)
80
All other output models
1
±5
25
Ripple & Noise
Agency approvals
Typical
3 sec
500VDC
Output Specifications
Units
50
100
ON –TTL High or Open ; OFF – TTL Low or short
Conditions
Tested I/O voltage
Resistance
Maximum
9-36
18-75
π(Pi) Network
24
48
On/Off control
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Typical
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Tel: +1 514 620 2722
2 of 5
EN55022: 2010, class A
EN55024: 2010
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-6
IEC 61000-4-8
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40UW-IZ
40Watt | DC-DC Converter
Pin Out Specifications
Pin
1000 & 3000VDC
Single
+V Input
-V Input
On/Off Control
No pin
+V Output
-V Output
Trim
1
2
3
4
5
6
7
Dual
+V Input
-V Input
On/Off Control
+V Output
Common
-V Output
Trim
Dimensions
10.16
(0.40)
Bottom View
5
2
6
3
7
10.16
(0.40)
50.80
(2.00)
5.08
(0.20)
1
10.16
(0.40)
22.86
(0.90)
4
10.16
(0.40)
50.80
(2.00)
45.70
(1.80)
Printed Face
Dimensions mm (inch)
Case Tolerance: ±0.25mm (±0.02inch)
Pin Length Tolerence: ±0.05mm (±0.002inch)
5.60
(0.22)
Side View
1.00
(0.04)
Trimming
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40UW-IZ
40Watt | DC-DC Converter
Derating
Free Air Convection
45 º C
Output Power (%)
100
80
Safe Operating Area
60
40
35
20
75
0
- 40
- 20
0
20
40
60
80
100
Ambient Temperature º C
Control ON/OFF pin connection example
Single Output
Dual Output
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40UW-IZ
40Watt | DC-DC Converter
Digital Control Circuit:
Vpeak
Control
Voltage
On / Off Control
0.5mA
NPN
0V
Ra =
Vpeak – 0.6
DC/DC
Converter
-V input
0.5mA
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only