Murata EUS34-096-NHCRVC Isolated bus converter Datasheet

EUS34-096
Isolated Bus Converter
INPUT CHARACTERISTICS
Conditions1
Parameter
Input voltage operating range
Min.
Typ.
Max.
38
48
55
VDC
60
VDC
Input voltage absolute
maximum
FEATURES
RoHS compliant
48 VIN, Isolated, 5:1 fixed conversion ratio
240W output at 38 VIN, 55ºC, 200 LFM
300W output at 48 VIN, 55ºC, 200 LFM
Industry standard 1/8 brick footprint
Remote enable (primary side, positive or
negative)
Over-temperature, over current protections
Direct parallel operation for higher power
DESCRIPTION
The EUS34-096 is a RoHS compliant fixed 5:1
ratio bus converter in an industry standard
eighth brick footprint to support Intermediate
Bus Architecture (IBA) for powering multiple
downstream non-isolated point-of-load (POL)
converters. The output is unregulated and the 5:1
fixed ratio is maintained between the input and
output voltages. It features input voltage range of
38V to 55V, and provides up to 300W @ 48Vin of
power. Typical efficiency of 9.6V module is 96%.
It can be parallel for more power.
Units
Input undervoltage lockout
Turn-on threshold
Turn-off threshold
Hysteresis voltage
34
32
35.5
33.5
2
36
34
VDC
VDC
VDC
Input overvoltage lockout
(latching type)
Turn-off threshold
57
58.5
59.5
VDC
Maximum input current
No-load input current
Disabled input current
Steady-state (34 A out)
Enabled state, no load (48 VIN)
Disabled state (48 VIN)
Input reflected ripple current
Measured into the input pin
Input capacitor 47μF type
Nichicon UPM1J470MPH or equivalant
6.7
100
7
Inrush current
Enable - negative logic version
Internal 27.4 KΩ
pulled-up to internal 5.0V
Resistance from enable pin
to -VIN
ADC
mA
mA
240
mA rms
51
A
On state range
-0.1
0.8
VDC
Off state range
2.4
15.0
VDC
With +VIN pin open, or tired to -VIN
TBD
KΩ
OUTPUT CHARACTERISTICS
Parameter
Conditions1
Min.
Typ.
Max.
Units
Output voltage set point
Output load regulation
VIN = 48V, IO = 0A
IO = 0 to 34A
VIN = 38 to 55V, IO = 0 to 34A,
Ta = 55ºC
20MHz bandwidth
Corresponding to PO = 240W
VIN = 48V, PO = 240W
9.40
9.50
0.4
9.60
VDC
V
11.0
Vdc
150
34
mV p-p
A
%
0.1
10
ms
10
150
±3
3
0
0
15
ms
ms
%VO
%
%
%
μF
Output voltage total regulation
2
Output ripple & noise
Output current operating range
Efficiency
From enable, <0.8V to VO> 10%
for VIN = 38V - 55V
Turn-on delay
3
Output voltage rise time
Start-up inhibit time
Transient response3
Current sharing accuracy
Output turn on overshoot
Output turn off undershoot
Maximum output capacitance
From 10% to 90%
Enabled: VIN applied to 90% VOUT
25% step, 1A/μs, ΔVO
At PO = 240W
7.0
50
0
96
10
3
3
3000
1 VIN = 48Vdc, Ta = 25ºC, Airflow = 200 LFM for all data unless otherwise noted.
2 Output Ripple Voltage and noise is specified when measured with a 10uF tantalum and a 1μF ceramic capacitor at the output pins.
3 During output voltage rise time (15 mS Max.), output power shall be limited to 50% constant power.
Transient response is specified with a 960μF capacitor at the output of the converter.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
EUS35-96.B01 Page 1 of 3
EUS34-096
Isolated Bus Converter
PROTECTION CHARACTERISTICS
Parameter
Output over-current shutdown
2
Over temperature shutdown3
Over temperature restart hysteresis
Conditions1
Min.
Typ.
Max.
Units
Auto-restart
Re-start rate
Auto-restart
38
40
TBD
135
10
42
A
ms
ºC
ºC
140
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Isolation voltage
Isolation resistance
Storage temperature range
Operating temperature range
Operating humidity
Thermal measurement location temperature3
Material flammability
Input to output
Input to output
Non-condensing
2250
10
-40
-40
10
MTBF
Non-condensing
See mechanical drawing for location
UL 94V-0
Calculated per Mil Spec 217 E, or Bellcore at Ta=30ºC
Demonstrated
Typ.
Max.
Units
125
85
90
130
VDC
MΩ
ºC
ºC
%
ºC
x106 Hrs
x106 Hrs
2
1.3
STANDARDS COMPLIANCE
Standards
UL/CSA 60950
Conditions4
Basic insulation
MANUFACTURING TESTING
Burn-in test
Parametric test
SAFETY CONSIDERATIONS
This series of converters are certified to the standards and extent listed in the ‘Standards Compliance’ section in the table above. If this product is built into
information technology equipment, the installation must comply with the above standard. Even though the product is safety certified to operate without an input
fuse, it is recommended that an input fuse of 12A (max.) is used.
The output of the converter (Vo+/Vo-) is considered to remain within SELV limits when the input to the converter meets SELV or TNV-2 requirements. The
converters and materials meet UL 94V-0 flammability ratings.
RoHS COMPLIANCE
The EUS34-096 converter is in compliance with the European Union Directive 2002/95/EC (RoHS) with respect to the
following substances: lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium, polybrominated biphenyls (PBB) and
polybrominated diphenyl ethers (PBDE).
For further information, please visit www.cd4power.com/rohs
1
2
3
4
VIN = 48Vdc, Ta = 25ºC, Airflow = 200 LFM for all data unless otherwise noted.
Input transient: if input voltage increases by 5V in 1μs, output over-current shut-down shall not be triggered (tested with Max. load and Max. output capacitance).
Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location.
See ‘Safety Considerations’ shown on page 4.
Derating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement Location temperature is below the maximum specified.
Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transversal to the unit).
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
EUS35-96.B01 Page 2 of 3
EUS34-096
Isolated Bus Converter
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
0.480
(12.19)
Max.
Ø0.040 ± 0.002 (1.02 ± 0.06)
(3X)
y
Ø0.062 ± 0.002 (1.57 ± 0.06)
(2X)
TML
2.28 (57.9)
0.14 (3.6)
0.300
(7.62)
0.300 (7.62)
PIN #4
PIN #3
0.45
(11.4)
0.90
(22.9)
PIN #2
PIN #1
Recommended
Footprint
Ø0.093 (2.36)
Ø0.060 (1.52)
PIN #5
Ø0.137 (3.48)
Ø0.105 (2.67)
0.300 (7.62)
0.300 (7.62)
2.000 (50.80)
Bottom view
Dimensions: 2.3 (58.4) L x 1.45 (36.83) W x 0.48 (12.19) H
All dimensions in inches (mm).
Tolerance: X.X (X.XX) ±0.5 (0.2), X.XX (X.XXX) ±0.25 (0.010).
Max. 0.480 (12.19) between highest component and mounting plane.
PIN CONNECTIONS
ORDERING INFORMATION
Pin
Assignment
1
2*
3
4
5
+VIN
ON/OFF
-VIN
-VOUT
+VOUT
EUS x x - y y y - N H z R v C
O u tp ut C urren t O u tp ut vo lta g e
34 = 34A
096 = 9.6V
Factory Internal Control Revision
(Not required when ordering)
E n a b le lo g ic
N = N e g ative lo g ic
P = P os itive log ic
* Referenced to Vi (-).
Positive logic: Floating = Enabled
Negative logic: Floating = Disabled
C = R oH S C o m p lia n t
H o rizo n ta l M o u n t
USA:
P in L e n g th
A = 0 .1 1 0 '' Reserved
B = 0 .1 4 5 ''
C = 0.2 0 0 ''
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada: Toronto, Tel: (866) 740-1232, email: [email protected]
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
Website: www.murata-ps.jp
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
04/18/08
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
EUS35-96.B01 Page 3 of 3
Similar pages