Purdy AND3222MST2 Lcd module Datasheet

Displays
AND3222MST2
6” FSTN LCD Module
The AND3222MST2 display is a compact, full dot matrix, with
“white page” appearance, LCD modules that have an on-board
LCD controller (SED1330) and display memory (RAM). The
AND3222MST2 can display TEXT information, numerals, letters
and symbols, as well as GRAPHIC patterns. These devices are
suitable for medical and measurement equipment, point-of-sale
terminals, protable equipment, and marine instrumentation.
Electrical/Optical Characteristics (Ta = 25°C)
• RoHS Compliant
Black and white ST (MST) transflective positive mode
Built-in CCFL backlight
Excellent readability and high-contrast ratio
320 (W) x 240 (H) dot graphic display
Built-in LCD controller (SED1330)
Wide operating temperature range (-20 to +70 ºC)
Available without controller (AND322MST-C)
6 o’clock viewing angle
Features
•
•
•
•
•
•
•
•
Item
Symbol
Condition
Power Supply
for Logic
VDD - VSS
–
Power Supply
for LCD Drive
VLCD - VSS
–
VIL
L level
0
–
0.6
V
VIH
H level
2.2
–
VDD
V
Ta = 0°C
–
22.7
–
VDD - VO
Ta = 25°C
–
24.3
–
–
25.8
–
IDD
34.9 31.3
–
IEE
VDD =5.0V
VDD - VO
=24.3V
CCFL Starting
Voltage
VFLS
CCFL Driving
Voltage
Input Voltage
Ta = 50°C
Mechanical Characteristics
Item
Specification
Unit
Outline
Dimensions
148.0 (W) x 120.2 (H) x 20.5 max (D)
mm
Number of
Pixels
320 (W) x 240 (H)
pixels
Active Area
120.14 (W) x 92.14 (H)
mm
Pixel Size
0.33 (W) x 0.33 (H)
mm
Pixel Pitch
0.36 (W) x 0.36 (H)
mm
1/240
–
SED1335
–
With
–
Duty
Controller
DC/DC Converter
Power Supply
Current for
LCM
VFLD
–
–
360
–
Vrms
CCFL Driving
Current
IFLD
–
5.0
–
mA
CCFL Driving
Frequency
fFL
VFLD
=450Vrms
fFL =30kHzV
15
30
85
KHz
CCFL
Saturation
Time
tSAT
Ta = 25°C
–
3
–
minut
Φ f (12 o’clock)
–
20
–
Φ b (6 o’clock)
When Cr ≥
1.4
–
40
–
–
30
–
–
30
–
–
175
–
–
170
–
–
64
–
Hz
–
4.5
–
–
600
650
–
cd/m2
Viewing Angle
Range
7.0
V
Power Supply for LCD
VDD - VLCD
0
30
V
Rise Time
Tr
VI
-0.3
VDD
V
Fall Time
Tf
CCFL Driving Voltage
VFL
0
500
Vrms
CCFL Input Current
IFL
–
7.0
mA
Tstg
-30
+80
ºC
Humidity
–
–
80
% RH
mA
Vrms
-0.3
ºC
V
–
VDD - VSS
+70
V
750
Power Supply for Logic
-20
-21.6 -22.1 -22.7
–
Unit
Top
V
–
Max.
Operating Temperature
5.5
–
Min.
Storage Temperature
5.0
3.6
Symbol
Input Voltage
4.5
Unit
–
Absolute Maximum Ratings
Item
Min. Typ. Max.
Φ l (9 o’clock)
Φ (3 o’clock)
Frame
Frequency
Frm
Contrast
Cr
Brightness of
Backlight
L
VDD - VO
=24.3V
Ta = 25°C
–
°
ms
Product specifications contained herein may be changed without prior notice.
It is therefore advisable to contact Purdy Electronics before proceeding with the design of equipment incorporating this product.
7/20/07
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected]
www.purdyelectronics.com
1
Displays
AND3222MST2
Dimensional Outline
Unit: mm
Standard Tolerance: 0.5mm
2
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected]
www.purdyelectronics.com
7/20/07
Displays
AND3222MST2
Timing Specifications
Item
Symbol
Min
Typ
Max
Unit
System Cycle Time
tCVC
425
–
–
ns
Address Set-up Time
tAW
30
–
–
ns
Address Hold Time
tAH
10
–
–
ns
Data Set-up Time
tDS
120
–
–
ns
Data Hold Time
tDH
10
–
–
ns
Output Disable Time
tOH
10
–
50
ns
AccessTime
tACC
Read
Enable Pulse Width
tEW
Write
–
–
120
ns
220
–
–
ns
220
–
–
ns
Timing Chart
Environmental Absolute Maximum Ratings
Normal Temperature
Item
Operating
Ambient Temperature
Humidity (without condensation)
Wide Temperature
Storage
Operating
Storage
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max
0 ºC
+50 ºC
-20 ºC
+70 ºC
-20 ºC
+70 ºC
-30 ºC
+80 ºC
See Notes 1, 3
See Notes 2, 4
See Notes 3, 4
See Notes 3, 5
NOTES:
1. Ta≤ 50 ºC: 80% RH max
Ta> 50 ºC: Absolute humidity must be lower than the humidity of 85%RH at 50 ºC
2. Ta at -20 ºC will be < 48 hrs at 0 ºC will be <120 hrs when humidity is higher than 75%.
3. Background color changes slightly depending on ambient temperature. This phenomenon is reversable.
4. Ta ≤ 70 ºC: 75RH max
Ta > 70 ºC: abosolute humidity must be lower than the humidity of 75%RH at 70 ºC.
5. Ta at -30 ºC will be <48hrs, at 80 ºC will be <120hrs when humidity is higher than 75%.
7/20/07
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected]
www.purdyelectronics.com
3
Displays
Power Supply
AND3222MST2
Connector Pin Assignment for Interface
Interface Pin Assignment
Terminal
No.
Symbol
Level
1
VSS
0V
Power Supply Ground
2
VDD
5V
Logic Supply Voltage
3
VO
–
Contrast Adjustment Voltage
4
/RD
L
Read Signal
5
/WR
L
6
Ao
H/L
7
DB0
H/L
8
DB1
H/L
9
DB2
H/L
10
DB3
H/L
11
DB4
H/L
12
DB5
H/L
13
DB6
H/L
14
DB7
H/L
15
/CS
L
Chip Signal
16
/RST
L
Reset Signal
17
VLCD
–
Power Supply for LCD
18
FG
–
For GND
19
NC
–
No Connection
20
NC
Function
Write Signal
Data Type Select
Data Bus Line
No Connection
Block Diagram
4
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected]
www.purdyelectronics.com
7/20/07