AD ADIS16364BMLZ Six degrees of freedom inertial sensor Datasheet

FEATURES
Tri-axis, 14-bit digital gyroscope with digital range scaling
±75°/sec, ±150°/sec, ±300°/sec settings
Tri-axis, 14-bit digital accelerometer
±5 g measurement range
330 Hz bandwidth
180 ms start-up time
Factory-calibrated sensitivity, bias, and axial alignment
Digitally controlled bias calibration
Digitally controlled sample rate, up to 819.2 SPS
External clock input enables sample rates up to 1200 SPS
Digitally controlled filtering
Programmable condition monitoring
Auxiliary digital input/output
Digitally activated self-test
Programmable power management
Embedded temperature sensor
SPI-compatible serial interface
Auxiliary, 12-bit ADC input and DAC output
Single-supply operation: 4.75 V to 5.25 V
2000 g shock survivability
Operating temperature range: −40°C to +105°C
FUNCTIONAL BLOCK DIAGRAM
AUX_
ADC
AUX_
DAC
TEMPERATURE
SENSOR
CS
MEMS
ANGULAR RATE
SENSOR
TRI-AXIS MEMS
ACCELERATION
SENSOR
SCLK
SIGNAL
CONDITIONING
AND
CONVERSION
CALIBRATION
AND
DIGITAL
PROCESSING
OUTPUT
REGISTERS
AND SPI
INTERFACE
DIN
DOUT
ALARMS
SELF-TEST
DIGITAL
CONTROL
POWER
MANAGEMENT
VCC
GND
ADIS16364
ADIS16300
RST DIO1 DIO2 DIO3 DIO4
07842-001
Preliminary Technical Data
Six Degrees of Freedom Inertial Sensor
ADIS16364
Figure 1.
APPLICATIONS
Medical instrumentation
Robotics
Platform control
Navigation
GENERAL DESCRIPTION
The ADIS16364 iSensor® is a complete inertial system that
includes a tri-axis gyroscope and tri-axis accelerometer. Each
sensor in the ADIS16364 combines industry-leading iMEMS®
technology with signal conditioning that optimizes dynamic
performance.
The factory calibration characterizes each sensor for sensitivity,
bias, alignment, and linear acceleration (gyro bias). As a result,
each sensor has its own dynamic compensation for correction
formulas that provide accurate sensor measurements over a
temperature range of −40°C to +85°C.
The ADIS16364 provides a simple, cost-effective method for
integrating accurate, multi-axis, inertial sensing into industrial
systems, especially when compared with the complexity and
investment associated with discrete designs.
All necessary motion testing and calibration are part of the
production process at the factory, greatly reducing system
integration time. Tight orthogonal alignment simplifies inertial
frame alignment in navigation systems. An improved SPI
interface and register structure provide faster data collection and
configuration control. By using a compatible pinout and the
same package as the ADIS1635x family, systems that currently
use the ADIS1635x family can upgrade their performance with
minor firmware changes to accommodate scale factor
adjustments.
This compact module is approximately 23 mm × 23 mm × 23
mm and provides a flexible connector interface, which enables
multiple mounting orientation options.
Rev. PrA
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2008 Analog Devices, Inc. All rights reserved.
ADIS16364
Preliminary Technical Data
TABLE OF CONTENTS
Features .............................................................................................. 1
Reading Sensor Data.....................................................................9
Applications....................................................................................... 1
Device Configuration ...................................................................9
Functional Block Diagram .............................................................. 1
Burst Mode Data Collection ........................................................9
General Description ......................................................................... 1
Output Data Registers ............................................................... 11
Specifications..................................................................................... 3
Calibration................................................................................... 11
Timing Specifications .................................................................. 5
Operational Control................................................................... 12
Timing Diagrams.......................................................................... 5
Input/Output Functions ............................................................ 13
Absolute Maximum Ratings............................................................ 6
Diagnostics.................................................................................. 14
ESD Caution.................................................................................. 6
Outline Dimensions ....................................................................... 16
Pin Configuration and Function Descriptions............................. 7
Ordering Guide .......................................................................... 16
Typical Performance Characteristics ............................................. 8
Basic Operation................................................................................. 9
Rev. PrA | Page 2 of 16
Preliminary Technical Data
ADIS16364
SPECIFICATIONS
TA = −40°C to +85°C, VCC = 5.0 V, angular rate = 0°/sec, dynamic range = ±300°/sec, ±1 g, unless otherwise noted.
Table 1.
Parameter
GYROSCOPES
Dynamic Range
Initial Sensitivity
Sensitivity Temperature Coefficient
Misalignment
Nonlinearity
Initial Bias Error
In-Run Bias Stability
Angular Random Walk
Bias Temperature Coefficient
Linear Acceleration Effect on Bias
Bias Voltage Sensitivity
Output Noise
Rate Noise Density
3 dB Bandwidth
Sensor Resonant Frequency
Self-Test Change in Output Response
ACCELEROMETERS
Dynamic Range
Initial Sensitivity
Initial Sensitivity Tolerance
Sensitivity Temperature Coefficient
Misalignment
Nonlinearity
Initial Bias Error
In-Run Bias Stability
Velocity Random Walk
Bias Temperature Coefficient
Bias Voltage Sensitivity
Output Noise
Noise Density
3 dB Bandwidth
Sensor Resonant Frequency
Self-Test Change in Output Response
TEMPERATURE SENSOR
Scale Factor
ADC INPUT
Resolution
Integral Nonlinearity
Differential Nonlinearity
Offset Error
Gain Error
Input Range
Input Capacitance
Test Conditions
TA = 25°C, dynamic range = ±300°/sec
TA = 25°C, dynamic range = ±150°/sec
TA = 25°C, dynamic range = ±75°/sec
Min
Typ
±300
0.0495
±375
0.05
0.025
0.0125
40
0.05
±0.5
0.1
±3
0.007
1.9
0.1
0.05
0.25
0.9
0.038
330
14.5
±1400
Reference to z-axis accelerometer, TA = 25°C
Axis-to-frame (package), TA = 25°C
Best fit straight line
TA = 25°C, ±1 σ
TA = 25°C, 1 σ, SMPL_PRD = 0x01
TA = 25°C, 1 σ, SMPL_PRD = 0x01
Any axis, 1 σ (MSC_CTRL, Bit 7 = 1)
VCC = 4.75 V to 5.25 V
TA = 25°C, ±300°/sec range, no filtering
TA = 25°C, f = 25 Hz, ±300°/sec, no filtering
±300°/sec range setting
Each axis
±696
Max
±2449
°/sec
°/sec/LSB
°/sec/LSB
°/sec/LSB
ppm/°C
Degrees
Degrees
% of FS
°/sec
°/sec
°/√hr
°/sec/°C
°/sec/g
°/sec/V
°/sec rms
°/sec/√Hz rms
Hz
kHz
LSB
180
g
mg/LSB
%
ppm/°C
Degrees
Degrees
% of FS
mg
mg
m/sec/√hr
mg/°C
mg/V
mg rms
mg/√Hz rms
Hz
kHz
LSB
0.0505
±5
25°C
1
±1
50
±0.25
±0.5
±0.3
±15
0.2
0.35
0.3
2.5
9
0.4
330
5.5
Axis-to-axis, TA = 25°C, Δ = 90° ideal
Axis-to-frame (package), TA = 25°C
Best fit straight line
TA = 25°C, ±1 σ
TA = 25°C, 1 σ
TA = 25°C, 1 σ
TA = 25°C, no filtering
TA = 25°C, no filtering
X-axis and y-axis
60
TA = 25°C output = 0x0000
0.14
°C/LSB
12
±2
±1
±4
±2
Bits
LSB
LSB
LSB
LSB
V
pF
0
During acquisition
+3.3
20
Rev. PrA | Page 3 of 16
Unit
ADIS16364
Parameter
DAC OUTPUT
Resolution
Relative Accuracy
Differential Nonlinearity
Offset Error
Gain Error
Output Range
Output Impedance
Output Settling Time
LOGIC INPUTS1
Input High Voltage, VINH
Input Low Voltage, VINL
Preliminary Technical Data
Test Conditions
5 kΩ/100 pF to GND
Min
Typ
12
±4
±1
±5
±0.5
For Code 101 to Code 4095
0
+3.3
2
10
2.0
0.8
0.55
CS signal to wake up from sleep mode
CS Wake-Up Pulse Width
Logic 1 Input Current, IINH
Logic 0 Input Current, IINL
All Pins Except RST
RST Pin
Input Capacitance, CIN
DIGITAL OUTPUTS1
Output High Voltage, VOH
Output Low Voltage, VOL
FLASH MEMORY
Data Retention3
FUNCTIONAL TIMES4
Power-On Start-up Time
Reset Recovery Time
Sleep Mode Recovery Time
Flash Memory Test Time
Automatic Self-Test Time
CONVERSION RATE
Clock Accuracy
Sync Input Clock
POWER SUPPLY
Power Supply Current
Max
20
VIH = 3.3 V
VIL = 0 V
ISOURCE = 1.6 mA
ISINK = 1.6 mA
Endurance2
TJ = 85°C
Time until data is available
Normal mode, SMPL_PRD ≤ 0x09
Low power mode, SMPL_PRD ≥ 0x0A
Normal mode, SMPL_PRD ≤ 0x09
Low power mode, SMPL_PRD ≥ 0x0A
Normal mode, SMPL_PRD ≤ 0x09
Low power mode, SMPL_PRD ≥ 0x0A
Normal mode, SMPL_PRD ≤ 0x09
Low power mode, SMPL_PRD ≥ 0x0A
SMPL_PRD = 0x01
SMPL_PRD = 0x01 to 0xFF
Operating voltage range, VCC
Low power mode at 25°C
Normal mode at 25°C
Sleep mode at 25°C
1
±0.2
±10
−40
−1
10
−60
2.4
0.4
10,000
20
180
250
60
130
4
9
17
90
12
0.413
4.75
5.0
24
49
500
Unit
Bits
LSB
LSB
mV
%
V
Ω
μs
V
V
V
μs
μA
μA
mA
pF
V
V
Cycles
Years
ms
ms
ms
ms
ms
819.2
±3
1.2
5.25
ms
ms
ms
SPS
%
kHz
V
mA
mA
μA
The digital I/O signals are driven by an internal 3.3 V supply, and the inputs are 5 V tolerant.
Endurance is qualified as per JEDEC Standard 22, Method A117, and measured at −40°C, +25°C, +85°C, and +125°C.
3
The retention lifetime equivalent is at a junction temperature (TJ) of 85°C as per JEDEC Standard 22, Method A117. Retention lifetime decreases with junction temperature.
4
These times do not include thermal settling and internal filter response times (330 Hz bandwidth), which may impact overall accuracy.
2
Rev. PrA | Page 4 of 16
Preliminary Technical Data
ADIS16364
TIMING SPECIFICATIONS
TA = 25°C, VCC = 5 V, unless otherwise noted.
Table 2.
Parameter
fSCLK
tSTALL
tREADRATE
tCS
tDAV
tDSU
tDHD
tSCLKR, tSCLKF
tDF, tDR
tSFS
t1
t2
t3
Normal Mode
(SMPL_PRD < 0x09)
Min1
Typ
Max
0.01
2.0
9
40
48.8
100
24.4
48.8
5
12.5
5
12.5
5
5
600
833
Description
Stall period between data
Read rate
Chip select to clock edge
DOUT valid after SCLK edge
DIN setup time before SCLK rising edge
DIN hold time after SCLK rising edge
SCLK rise/fall times
DOUT rise/fall times
CS high after SCLK edge
Input sync pulse width
Input sync to data ready output
Input sync period
Low Power Mode
(SMPL_PRD > 0x0A)
Min1
Typ
Max
0.01
0.3
75
100
48.8
100
24.4
48.8
5
12.5
5
12.5
5
Burst Mode
Min1
Typ Max
0.01
1.0
1/fSCLK
48.8
100
24.4
48.8
5
5
12.5
12.5
5
1
Guaranteed by design and characterization, but not tested in production.
TIMING DIAGRAMS
CS
tCS
tSFS
1
2
3
4
5
6
15
16
SCLK
tDAV
MSB
DB14
DB13
tDSU
DIN
W/R
A6
DB12
DB11
A4
A3
DB10
DB2
DB1
LSB
tDHD
A5
A2
D2
D1
07482-002
DOUT
LSB
Figure 2. SPI Timing and Sequence
tREADRATE
tSTALL
CS
07482-003
SCLK
Figure 3. Stall Time and Data Rate
t3
t2
t1
07482-004
SYNC
CLOCK (DIO4)
DATA
READY
Figure 4. Input Clock Timing Diagram
Rev. PrA | Page 5 of 16
Unit
MHz
μs
μs
ns
ns
ns
ns
ns
ns
ns
μs
μs
μs
ADIS16364
Preliminary Technical Data
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Acceleration
Any Axis, Unpowered
Any Axis, Powered
VCC to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
Analog Input to GND
Operating Temperature Range
Storage Temperature Range
1
Rating
2000 g
2000 g
−0.3 V to +6.0 V
−0.3 V to +5.3 V
−0.3 V to VCC + 0.3 V
−0.3 V to +3.6 V
−40°C to +105°C
−65°C to +125°C1, 2
Extended exposure to temperatures outside the specified temperature
range of −40°C to +85°C can adversely affect the accuracy of the factory
calibration. For best accuracy, store the parts within the specified operating
range of −40°C to +85°C.
2
Although the device is capable of withstanding short-term exposure to
150°C, long-term exposure threatens internal mechanical integrity.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 4. Package Characteristics
Package Type
24-Lead Module
ESD CAUTION
Rev. PrA | Page 6 of 16
θJA
39.8°C/W
θJC
14.2°C/W
Device Weight
16 grams
Preliminary Technical Data
ADIS16364
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
DIO3
SCLK
DIN
DIO1
DIO2
VCC
GND
GND
DNC
DNC
AUX_ADC
DNC
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
DIO4/CLKIN
DOUT
CS
RST
VCC
VCC
GND
DNC
DNC
AUX_DAC
DNC
DNC
TOP VIEW
(Not to Scale)
NOTES
1. CONNECTOR PINS ARE NOT VISIBLE FROM THE TOP VIEW.
2. THIS REPRESENTATION DISPLAYS THE TOP VIEW PINOUT
FOR THE MATING SOCKET CONNECTOR.
3. DNC = DO NOT CONNECT.
07570-005
ADIS16365
Figure 5. Pin Configuration
Figure 6. Axial Orientation
Table 5. Pin Function Descriptions
Pin No.
1
2
16, 17, 18, 19, 22, 23, 24
3
4
5
6
7
8
9
10, 11, 12
13, 14, 15
20
21
1
Mnemonic
DIO3
DIO4/CLKIN
DNC
SCLK
DOUT
DIN
CS
DIO1
RST
DIO2
VCC
GND
AUX_DAC
AUX_ADC
Type1
I/O
I/O
N/A
I
O
I
I
I/O
I
I/O
S
S
O
I
Description
Configurable Digital Input/Output.
Configurable Digital Input/Output or Sync Clock Input.
Do Not Connect.
SPI Serial Clock.
SPI Data Output. Clocks output on SCLK falling edge.
SPI Data Input. Clocks input on SCLK rising edge.
SPI Chip Select.
Configurable Digital Input/Output.
Reset.
Configurable Digital Input/Output.
Power Supply.
Power Ground.
Auxiliary, 12-Bit DAC Output.
Auxiliary, 12-Bit ADC Input.
S is supply, O is output, I is input, N/A is not applicable.
Rev. PrA | Page 7 of 16
ADIS16364
Preliminary Technical Data
TYPICAL PERFORMANCE CHARACTERISTICS
0.1
0.01
07482-007
ROOT ALLAN VARIANCE (°/sec)
1
0.001
0.1
1
10
100
INTEGRATION TIME (sec)
1k
10k
Figure 8. Accelerometer Allan Variance
Figure 7. Gyroscope Allan Variance
Rev. PrA | Page 8 of 16
Preliminary Technical Data
ADIS16364
BASIC OPERATION
I/O LINES ARE COMPATIBLE WITH
3.3V OR 5V LOGIC LEVELS
5V
VDD
10
SYSTEM
PROCESSOR
SPI MASTER
SS
6
11
12
ADIS16300
CS
3
SCLK
MOSI
5
DIN
MISO
4
DOUT
IRQ
7
DIO1
14
15
Figure 9. Electrical Hook-Up Diagram
Table 6. Generic Master Processor Pin Names and Functions
Pin Name
SS
IRQ
MOSI
MISO
SCLK
Function
Slave select
Interrupt request
Master output, slave input
Master input, slave output
Serial clock
Table 7. Generic Master Processor SPI Settings
Processor Setting
Master
SCLK Rate ≤ 2 MHz1
CPOL = 1
CPHA = 1
MSB-First
16-Bit
1
14
13
12
11
10
9
8
UPPER BYTE
7
6
5
4
3
LOWER BYTE
2
1
0
Figure 10. Output Register Bit Assignments
READING SENSOR DATA
Although the ADIS16364 produces data independently, it operates as a SPI slave device, which communicates with system
(master) processors using the 16-bit segments displayed in
Figure 11. Individual register reads require two 16-bit sequences.
The first 16-bit sequence provides the read command bit (R/W
= 0) and the target register address (A6 … A0). The second
sequence transmits the register contents (D15 … D0) on the
DOUT line. For example, if DIN = 0x0A00, then the content of
XACCL_OUT shifts out on the DOUT line during the next 16-bit
sequence.
DEVICE CONFIGURATION
07482-009
13
15
The SPI operates in full duplex mode, which means that the master
processor can read the output data from DOUT while using the
same SCLK pulses to transmit the next target address on DIN.
SPI SLAVE
SCLK
Table 8 provides the lower byte address for each register, and
Figure 10 provides the generic bit assignments.
07482-110
The ADIS16364 is an autonomous sensor system that starts up
after it has a valid power supply voltage and begins producing
inertial measurement data at a sample rate of 819.2 SPS. After
each sample cycle, the sensor data loads into the output registers
and DIO1 pulses, providing a new data ready control signal for
driving system-level interrupt service routines. In a typical
system, a master processor accesses the output data registers
through the SPI interface, using the hook-up shown in Figure 9.
Table 6 provides a generic, functional description for each pin
on the master processor. Table 7 describes the typical master
processor settings normally found in a configuration register
and used for communicating with the ADIS16364.
Description
The ADIS16364 operates as a slave.
Normal mode, SMPL_PRD[7:0] ≤ 0x08.
Clock polarity.
Clock phase.
Bit sequence.
Shift register/data length.
For burst mode, SCLK rate ≤ 1 MHz. For low power mode, SCLK rate ≤ 300 kHz.
The user registers provide addressing for all input/output
operations on the SPI interface. Each 16-bit register has two
7-bit addresses: one for its upper byte and one for its lower byte.
The user register memory map (see Table 8) identifies configuration registers with either a W or R/W. Configuration commands
also use the bit sequence displayed in Figure 12. If the MSB is
equal to 1, the last eight bits (DC7 ... DC0) in the DIN sequence
load into the memory address associated with the address bits
(A5 ... A0). For example, if the DIN = 0xA11F, then 0x1F loads
into Address Location 0x26 (ALM_MAG1, upper byte) at the
conclusion of the data frame.
Most of the registers have a backup location in nonvolatile flash
memory. The master processor must manage the backup
function. Set GLOB_CMD[3] = 1 (DIN = 0xBE01) to execute a
manual flash update (backup) operation, which copies the user
registers into their respective flash memory locations. This
operation takes 50 ms and requires the power supply voltage
to be within the specified limit to complete properly. The
FLASH_CNT register provides a running count of these events
for managing the long-term reliability of the flash memory.
BURST MODE DATA COLLECTION
Burst mode data collection offers a more process-efficient
method for collecting data from the ADIS16364. In 10
sequential data cycles (each separated by one SCLK period), all
nine output registers clock out on DOUT. This sequence starts
when the DIN sequence is 0011 1110 0000 0000 (0x3E00). Next,
the contents of each output register are output from DOUT,
starting with SUPPLY_OUT and ending with AUX_ADC (see
Figure 12). The addressing sequence shown in Table 8 determines the order of the outputs in burst mode.
Rev. PrA | Page 9 of 16
ADIS16364
Preliminary Technical Data
Table 8. User Register Memory Map
Name
FLASH_CNT
SUPPLY_OUT
XGYRO_OUT
YGYRO_OUT
ZGYRO_OUT
XACCL_OUT
YACCL_OUT
ZACCL_OUT
XTEMP_OUT
YTEMP_OUT
ZTEMP_OUT
AUX_ADC
N/A
XXGYRO_OFF
YXGYRO_OFF
ZXGYRO_OFF
XACCL_OFF
YACCL_OFF
ZACCL_OFF
ALM_MAG1
ALM_MAG2
ALM_SMPL1
ALM_SMPL2
ALM_CTRL
AUX_DAC
GPIO_CTRL
MSC_CTRL
SMPL_PRD
SENS_AVG
SLP_CNT
DIAG_STAT
GLOB_CMD
1
R/W
R
R
R
R
R
R
R
R
R
R
R
R
N/A
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
W
R
W
Address1
0x00
0x02
0x04
0x06
0x08
0x0A
0x0C
0x0E
0x10
0x12
0x14
0x16
0x18
0x1A
0x1C
0x1E
0x20
0x22
0x24
0x26
0x28
0x2A
0x2C
0x2E
0x30
0x32
0x34
0x36
0x38
0x3A
0x3C
0x3E
Flash Backup
Yes
No
No
No
No
No
No
No
No
No
No
No
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
No
No
N/A
Default
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0006
0x0001
0x0402
0x0000
0x0000
0x0000
Function
Flash memory write count
Power supply measurement
X-axis gyroscope output
Y-axis gyroscope output
Z-axis gyroscope output
X-axis accelerometer output
Y-axis accelerometer output
Z-axis accelerometer output
X-axis gyroscope temperature measurement
Y-axis gyroscope temperature measurement
Z-axis gyroscope temperature measurement
Auxiliary ADC output
Reserved
X-axis gyroscope bias offset factor
Y-axis gyroscope bias offset factor
Z-axis gyroscope bias offset factor
X-axis acceleration bias offset factor
Y-axis acceleration bias offset factor
Z-axis acceleration bias offset factor
Alarm 1 amplitude threshold
Alarm 2 amplitude threshold
Alarm 1 sample size
Alarm 2 sample size
Alarm control
Auxiliary DAC data
Auxiliary digital input/output control
Miscellaneous control
Internal sample period (rate) control
Dynamic range/digital filter control
Sleep mode control
System status
System command
Bit Assignments
N/A
Table 9
Table 9
Table 9
Table 9
Table 9
Table 9
Table 9
Table 9
Table 9
Table 9
Table 9
N/A
Table 10
Table 10
Table 10
Table 11
Table 11
Table 11
Table 22
Table 22
Table 23
Table 23
Table 24
Table 18
Table 16
Table 17
Table 13
Table 15
Table 14
Table 21
Table 12
Each register contains two bytes. The address of the lower byte is displayed. The address of the upper byte is equal to the address of the lower byte, plus 1.
CS
SCLK
DOUT
R/W
D15
A6
A5
A4
A3
A2
A1
A0
DC7
DC6
DC5
DC4
DC3
DC2
DC1
DC0
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
R/W
D15
A6
A5
D14
D13
07482-111
DIN
NOTES
1. DOUT BITS ARE BASED ON THE PREVIOUS 16-BIT SEQUENCE (R = 0).
Figure 11. Output Register Bit Assignments
CS
1
2
3
4
5
9
GYRO_OUT
XACCL_OUT
YACCL_OUT
YINCL_OUT
10
SCLK
DOUT
0x3E00
PREVIOUS
DON’T CARE
SUPPLY_OUT
Figure 12. Burst Mode Read Sequence
Rev. PrA | Page 10 of 16
AUX_ADC
07482-012
DIN
Preliminary Technical Data
ADIS16364
VCC
Figure 6 provides the positive measurement direction for each
inertial sensor (gyroscope and accelerometers). Table 9 provides
the configuration and scale factor for each output data register
in the ADIS16364. All inertial sensor outputs are 14 bits in
length and are in twos complement format, which means that
0x0000 is equal to 0 LSB, 0x0001 is equal to +1 LSB, and 0x3FFF
is equal to −1 LSB. The following is an example of how to
calculate the sensor measurement from the XGYRO_OUT:
Rate = 0.05°/sec × (− 1206 ) = −60.3°/sec
Therefore, an XGYRO_OUT output of 0x3B4A corresponds to
a clockwise rotation about the z-axis (see Figure 6) of 60.3°/sec
when looking at the top of the package.
Table 9. Output Data Register Formats
1
2
Bits
12
14
14
14
14
14
14
12
12
12
12
Format
Binary, 5 V = 0x0814
Twos complement
Twos complement
Twos complement
Twos complement
Twos complement
Twos complement
Twos complement
Twos complement
Twos complement
Binary, 1 V = 0x04D9
Scale
2.42 mV
0.05°/sec
0.05°/sec
0.05°/sec
1 mg
1 mg
1 mg
0.14°C
0.14°C
0.14°C
0.81 mV
Assumes that the scaling is set to ± 300°/sec. This factor scales with the range.
Note that typically, +25°C, these registers read 0x0000.
Each output data register uses the bit assignments shown in
Figure 13. The ND flag indicates that unread data resides in the
output data registers. This flag clears and returns to 0 during an
output register read sequence. It returns to 1 after the next
internal sample updates the registers with new data. The EA flag
indicates that one of the error flags in the DIAG_STAT register
(see Table 21) is active (true). The remaining 14 bits are for data.
MSB FOR 12-BIT OUTPUT
07842-013
MSB FOR 14-BIT OUTPUT
ND EA
C1
D
R1 C2
Figure 14. Equivalent Analog Input Circuit
(Conversion Phase: Switch Open,
Track Phase: Switch Closed)
CALIBRATION
Manual Bias Calibration
XGYRO_OUT = 0x3B4A
0x000 − 0x33B4A = −0x04B6 = −(4 × 256 + 11 × 16 + 6)
− 0x04B6 = −1206 LSB
Register
SUPPLY_OUT
XGYRO_OUT1
YGYRO_OUT1
ZGYRO_OUT1
XACCL_OUT
YACCL_OUT
ZACCL_OUT
XTEMP_OUT2
YTEMP_OUT2
ZTEMP_OUT2
AUX_ADC
D
07842-011
OUTPUT DATA REGISTERS
The bias offset registers in Table 10 and Table 11 provide a manual
adjustment function for the output of each sensor. For example,
if XGYRO_OFF equals 0x1FF6, the XGYRO_OUT offset shifts
by −10 LSBs, or −0.125°/sec. The DIN command for the upper
byte is DIN = 0x9B1F; for the lower byte, DIN = 0x9AF6.
Table 10. XGYRO_OFF, YGYRO_OFF, ZGYRO_OFF
Bits
[15:13]
[12:0]
Description
Not used.
Data bits. Twos complement, 0.0125°/sec per LSB.
Typical adjustment range = ±50°/sec.
Table 11. XACCL_OFF, YACCL_OFF, ZACCL_OFF
Bits
[15:12]
[11:0]
Description
Not used.
Data bits, twos complement 1 mg/LSB.
Typical adjustment range = ±2 g.
Gyroscope Automatic Bias Null Calibration
Set GLOB_CMD[0] = 1 (DIN = 0xBE01) to execute this function,
which measures XGYRO_OUT and then loads XGYRO_OFF
with the opposite value to provide a quick bias calibration.
Then, all sensor data resets to 0, and the flash memory updates
automatically (50 ms). See Table 12.
Gyroscope Precision Automatic Bias Null Calibration
Set GLOB_CMD[4] = 1 (DIN = 0xBE10) to execute this
function, which takes the sensor offline for 30 sec while it
collects a set of XGYRO_OUT data and calculates a more
accurate bias correction factor. Once calculated, the correction
factor loads into XGYRO_OFF, all sensor data resets to 0, and
the flash memory updates automatically (50 ms). See Table 12.
Restoring Factory Calibration
Figure 13. Output Register Bit Assignments
Auxiliary ADC
The AUX_ADC register provides access to the auxiliary ADC
input channel. The ADC is a 12-bit successive approximation
converter, which has an equivalent input circuit to the one
in Figure 14. The maximum input range is +3.3 V. The ESD
protection diodes can handle 10 mA without causing irreversible
damage. The switch on-resistance (R1) has a typical value of
100 Ω. The sampling capacitor, C2, has a typical value of 16 pF.
Set GLOB_CMD[1] = 1 (DIN = 0xBE02) to execute this function,
which resets each user calibration register (see Table 10 and
Table 11) to 0x0000, resets all sensor data to 0, and automatically updates the flash memory (50 ms). See Table 12.
Linear Acceleration Bias Compensation (Gyroscope)
Set MSC_CTRL[7] = 1 (DIN = 0xB486) to enable correction for
low frequency acceleration influences on gyroscope bias. Note
that the DIN sequence also preserves the factory default condition for the data ready function (see Table 17).
Rev. PrA | Page 11 of 16
ADIS16364
Preliminary Technical Data
OPERATIONAL CONTROL
Table 14. SLP_CNT
Global Commands
Bit
[15:9]
[8]
[7:0]
The GLOB_CMD register provides trigger bits for several useful
functions. Setting the assigned bit to 1 starts each operation,
which returns to the bit to 0 after completion. For example, set
GLOB_CMD[7] = 1 (DIN = 0xBE80) to execute a software
reset, which stops the sensor operation and runs the device
through its start-up sequence. This includes loading the control
registers with their respective flash memory locations prior to
producing new data. Reading the GLOB_CMD registers (DIN =
0x3E00) starts the burst mode read sequence.
Table 12. GLOB_CMD
Description
Not used
Software reset command
Not used
Precision autonull command
Flash update command
Auxiliary DAC data latch
Factory calibration restore command
Autonull command
Digital Filtering
A programmable low-pass filtering provides additional
opportunity for noise reduction on the inertial sensor outputs.
This filter contains two cascaded averaging filters that provide a
Bartlett window, FIR filter response (see Figure 15).
SENS_AVG[2:0] controls the number of taps in each averaging
stage. For example, SENS_AVG[2:0] = 110 sets each stage tap to
64.
0
–20
–40
MAGNITUDE (dB)
Internal Sample Rate
–60
–80
–100
The ADIS16364 performs best when the sample rate is set to the
factory default setting of 819.2 SPS. For applications that value
lower sample rates, the SMPL_PRD register controls the
ADIS16364 internal sample (see Table 13), and the following
relationship produces the sample rate:
–120
–140
0.001
0.1
1
Figure 15. Bartlett Window FIR Frequency Response
(Phase = M Samples)
Table 13. SMPL_PRD
[6:0]
0.01
FREQUENCY (f/fS)
tS = tB × NS + 1
Bit
[15:8]
[7]
N=2
N=4
N = 16
N = 64
Dynamic Range
Description
Not used
Time base (tB)
0 = 0.61035 ms, 1 = 18.921 ms
Increment setting (NS)
Internal sample period = tS = tB × NS + 1
For example, set SMPL_PRD[7:0] = 0x0A (DIN = 0xB60A) for
an internal sample period of 6.7 ms (sample rate = 149 SPS).
For systems that value lower sample rates, in-system characterization can help determine performance trade-offs.
Power Management
Setting SMPL_PRD ≥ 0x0A also sets the sensor in low power
mode. In addition to sensor performance, this mode also affects
SPI data rates (see Table 2). Two sleep mode options are listed
in Table 14. Set SLP_CNT[8] = 1 (DIN = 0xBB01) to start the
indefinite sleep mode, which requires CS assertion (high to low),
reset, or power cycle to wake-up. Set SLP_CNT[7:0] = 0x64
(DIN = 0xBA64) to put the ADIS16364 to sleep for 100 sec, as
an example of the programmable sleep time option.
There are three dynamic range settings for the gyroscope:
±75°/sec, ±150°/sec, and ±300°/sec. The lower dynamic range
settings (±75°/sec and ±150°/sec) limit the minimum filter tap
sizes to maintain the resolution as the measurement range
decreases. The recommended order for programming the
SENS_AVG register is upper byte (sensitivity), followed by
lower byte (filtering). For example, set SENS_AVG[10:8] = 010
(DIN = 0xB902) for a measurement range to ±150°/sec.
Table 15. SENS_AVG
Bits
[15:11]
[10:8]
Value
100
010
001
[7:3]
[2:0]
Rev. PrA | Page 12 of 16
Description
Not used
Measurement range (sensitivity) selection
±300°/sec (default condition)
±150°/sec, filter taps ≥ 4 (Bits[2:0] ≥ 0x02)
±75°/sec, filter taps ≥ 16 (Bits[2:0] ≥ 0x04)
Not used
Number of taps in each stage N = 2M
07570-010
Bits
[15:8]
[7]
[6:5]
[4]
[3]
[2]
[1]
[0]
Description
Not used
Indefinite sleep mode, set to 1
Programmable time bits, 0.5 sec/LSB
Preliminary Technical Data
ADIS16364
INPUT/OUTPUT FUNCTIONS
Table 17. MSC_CTRL
General-Purpose I/O
Bits
[15:12]
[11]
DIO1, DIO2, DIO3, and DIO4 are configurable, general-purpose
I/O lines that serve multiple purposes according to the following
control register priority: MSC_CTRL, ALM_CTRL, and
GPIO_CTRL. For example, set GPIO_CTRL = 0x080C (DIN =
0xB508, then 0xB40C) to set DIO1 and DIO2 as inputs and
DIO3 and DIO4 as outputs, with DIO3 set low and DIO4 set high.
[2]
[1]
[0]
[9]
[8]
Table 16. GPIO_CTRL
Bit
[15:12]
[11]
[10]
[9]
[8]
[7:4]
[3]
[10]
Description
Not used
General-Purpose I/O Line 4 (DIO4) data level
General-Purpose I/O Line 3 (DIO3) data level
General-Purpose I/O Line 2 (DIO2) data level
General-Purpose I/O Line 1 (DIO1) data level
Not used
General-Purpose I/O Line 4 (DIO4), direction control
1 = output, 0 = input
General-Purpose I/O Line 3 (DIO3), direction control
1 = output, 0 = input
General-Purpose I/O Line 2 (DIO2), direction control
1 = output, 0 = input
General-Purpose I/O Line 1 (DIO1), direction control
1 = output, 0 = input
Input Clock Configuration
The input clock configuration function allows for external
control over sampling in the ADIS16364. Set GPIO_CTRL[3] =
0 (DIN = 0x0B200) and SMPL_PRD[7:0] = 0x00 (DIN =
0xB600) to enable this function. See Table 2 and Figure 4 for
timing information.
Data Ready I/O Indicator
The factory default sets DIO1 as a positive data ready indicator
signal. The MSC_CTRL[2:0] register provides configuration
options for changing this. For example, set MSC_CTRL[2:0] =
100 (DIN = 0xB404) to change the polarity of the data ready
signal for interrupt inputs that require negative logic inputs for
activation. The pulse width will be between 100 μs and 200 μs
over all conditions.
[7]
[6]
[5:3]
[2]
[1]
[0]
Description
Not used
Memory test (clears on completion)
1 = enabled, 0 = disabled
Internal self-test enable (clears on completion)
1 = enabled, 0 = disabled
Manual self-test, negative stimulus
1 = enabled, 0 = disabled
Manual self-test, positive stimulus
1 = enabled, 0 = disabled
Linear acceleration bias compensation for gyroscopes
1 = enabled, 0 = disabled
Linear accelerometer origin alignment
1 = enabled, 0 = disabled
Not used
Data ready enable
1 = enabled, 0 = disabled
Data ready polarity
1 = active high, 0 = active low
Data ready line select
1 = DIO2, 0 = DIO1
Auxiliary DAC
The 12-bit AUX_DAC line can drive its output to within 5 mV
of the ground reference when it is not sinking current. As the
output approaches 0 V, the linearity begins to degrade (~100 LSB
beginning point). As the sink current increases, the nonlinear
range increases. The DAC latch command moves the values of
the AUX_DAC register into the DAC input register, enabling
both bytes to take effect at the same time.
Table 18. AUX_DAC
Bit
[15:12]
[11:0]
Description
Not used
Data bits, scale factor = 0.8059 mV/code
Offset binary format, 0 V = 0 codes
Table 19. Setting AUX_DAC = 1 V
DIN
0xB0D9
0xB104
0xBE04
Rev. PrA | Page 13 of 16
Descripition
AUX_DAC[7:0] = 0xD9 (217 LSB).
AUX_DAC[15:8] = 0x04 (1024 LSB).
GLOB_CMD[2] = 1.
Move values into the DAC input register, resulting
in a 1 V output level.
ADIS16364
Preliminary Technical Data
DIAGNOSTICS
Status
Self-Test
The error flags provide indicator functions for common system
level issues. All of the flags clear (set to 0) after each DIAG_STAT
register read cycle. If an error condition remains, the error flag
returns to 1 during the next sample cycle. DIAG_STAT[1:0]
does not require a read of this register to return to 0. If the
power supply voltage goes back into range, these two flags clear
automatically.
Self-test offers the opportunity to verify the mechanical
integrity of each MEMS sensor. It applies an electrostatic force
to each sensor element, which results in mechanical displacement that simulates a response to actual motion. Table 1 lists
the expected response for each sensor, which provides pass/fail
criteria. Set MSC_CTRL[10] = 1 (DIN = 0xB504) to run the
internal self-test routine, which exercises all inertial sensors,
measures each response, makes pass/fail decisions, and reports
them to error flags in the DIAG_STAT register. MSC_CTRL[10]
resets itself to 0 after completing the routine. MSC_CTRL[9:8]
(DIN = 0xB502 or 0xB501) provides manual control over the
self-test function. Table 20 gives an example test flow for using
this option.
Table 20. Manual Self-Test Example Sequence
DIN
0xB601
0xB904
0xB802
0x0400
0x0600
0x0800
0x0A00
0xB502
0x0400
0xB501
0x0400
0x0600
0x0800
0x0A00
0xB500
Description
SMPL_PRD[7:0] = 0x01, sample rate = 819.2 SPS.
SENS_AVG[15:8] = 0x04, gyro range = ±300°/sec.
SENS_AVG[7:0] = 0x02, 4-tap averaging filter.
Delay = 50 ms.
Read XGYRO_OUT.
Read XACCL_OUT.
Read YACCL_OUT.
Read ZACCL_OUT.
MSC_CTRL[9] = 1, gyroscope negative self-test.
Delay = 50 ms.
Read XGYRO_OUT.
Determine whether the bias in the gyroscope
output changes according to the expectation set
in Table 2.
MSC_CTRL[9:8] = 01, gyroscope/accelerometer
positive self-test.
Delay = 50 ms.
Read XGYRO_OUT.
Read XACCL_OUT.
Read YACCL_OUT.
Read ZACCL_OUT
Determine whether the bias in the gyroscope and
accelerometers changed according to the expectation set in Table 2.
MSC_CTRL[15:8] = 0x00.
Zero motion provides results that are more reliable. The settings
in Table 20 are flexible and provide opportunity for optimization
around speed and noise influence. For example, lowering the
filtering taps decreases delay times but increases the opportunity
for noise influence.
Table 21. DIAG_STAT Bit Descriptions
Bit
[15]
[14]
[13]
[12]
[11]
[10]
[9]
[8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
Description
Z-axis accelerometer self-test failure (1 = fail, 0 = pass)
Y-axis accelerometer self-test failure (1 = fail, 0 = pass)
X-axis accelerometer self-test failure (1 = fail, 0 = pass)
X-axis gyroscope self-test failure (1 = fail, 0 = pass)
Y-axis gyroscope self-test failure (1 = fail, 0 = pass)
Z-axis gyroscope self-test failure (1 = fail, 0 = pass)
Alarm 2 status (1 = active, 0 = inactive)
Alarm 1 status (1 = active, 0 = inactive)
Not used
Flash test, checksum flag (1 = fail, 0 = pass)
Self-test diagnostic error flag (1 = fail, 0 = pass)
Sensor overrange (1 = fail, 0 = pass)
SPI communications failure (1 = fail, 0 = pass)
Flash update failed (1 = fail, 0 = pass)
Power supply above 5.25 V
1 = power supply ≥ 5.25 V, 0 = power supply ≤ 5.25 V
Power supply below 4.75 V
1 = power supply ≤ 4.75 V, 0 = power supply ≥ 4.75 V
Alarm Registers
The alarm function provides monitoring for two independent
conditions. The ALM_CTRL register provides control inputs
for data source, data filtering (prior to comparison), static
comparison, dynamic rate-of-change comparison, and output
indicator configurations. The ALM_MAGx registers establish the
trigger threshold and polarity configurations.
Table 25 gives an example of how to configure a static alarm.
The ALM_SMPLx registers provide the numbers of samples to
use in the dynamic rate-of-change configuration. The period
equals the number in the ALM_SMPLx register, multiplied by
the sample period time, established by the SMPL_PRD register.
See Table 26 for an example of how to configure the sensor for
this type of function.
Memory Test
Setting MSC_CTRL[11] = 1 (DIN = 0xB508) performs a
checksum verification of the flash memory locations. The
pass/fail criteria load into the DIAG_STAT[6] register.
Rev. PrA | Page 14 of 16
Preliminary Technical Data
ADIS16364
Table 22. ALM_MAG1, ALM_MAG2
Table 25. Alarm Configuration Example 1
Bit
[15]
DIN
0xAF55,
0xAE17
[14]
[13:0]
Description
Comparison polarity
1 = greater than, 0 = less than
Not used
Data bits that match the format of the trigger source
selection
Table 23. ALM_SMPL1, ALM_SMPL2
0xA783,
0xA641
Bit
[15:8]
[7:0]
0xA93C,
0xA8BF
Description
Not used
Data bits: number of samples (both 0x00 and 0x01 = 1)
Table 26. Alarm Configuration Example 2
Table 24. ALM_CTRL Bit Designations
Bits
[15:12]
Value
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
[11:8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
1
Description
ALM_CTRL = 0x5517.
Alarm 1 input = XACCL_OUT.
Alarm 2 input = XACCL_OUT.
Static level comparison, filtered data.
DIO2 output indicator, positive polarity.
ALM_MAG1 = 0x8341.
Alarm 1 is true if XACCL_OUT > 0.5 g.
ALM_MAG2= 0x3CBF.
Alarm 2 is true if XACCL_OUT < −0.5 g.
Description
Alarm 2 source selection
Disable
Power supply output
X-axis gyroscope output
Y-axis gyroscope output
Z-axis gyroscope output
X-axis accelerometer output
Y-axis accelerometer output
Z-axis accelerometer output
Gyroscope temperature output
X-axis inclinometer output
Y-axis inclinometer output
Auxiliary ADC input
Alarm 1 source selection (same as Alarm 2)
Rate of change (ROC) enable for Alarm 2
1 = rate of change, 0 = static level
Rate of change (ROC) enable for Alarm 1
1 = rate of change, 0 = static level
Not used
Comparison data filter setting1
1 = filtered data, 0 = unfiltered data
Not used
Alarm output enable
1 = enabled, 0 = disabled
Alarm output polarity
1 = active high, 0 = active low
Alarm output line select
1 = DIO2, 0 = DIO1
DIN
0xAF76,
0xAE87
0xB601
0xAB08
0xAC50
0xA783,
0xA641
0xA93C,
0xA8BE
Incline outputs always use filtered data in this comparison.
Rev. PrA | Page 15 of 16
Description
ALM_CTRL = 0x7687.
Alarm 1 input = ZACCL_OUT.
Alarm 2 input = YACCL_OUT.
Rate of change comparison, unfiltered data.
DIO2 output indicator, positive polarity.
SMPL_PRD = 0x0001.
Sample rate = 819.2 SPS.
ALM_SMPL1 = 0x0008.
Alarm 1 rate of change period = 9.77 ms.
ALM_SMPL2= 0x0050.
Alarm 2 rate of change period = 97.7 ms.
ALM_MAG1 = 0x8341.
Alarm 1 is true if XACCL_OUT > 0.5 g.
ALM_MAG2= 0x3CBE.
Alarm 2 is true if XACCL_OUT < −0.5 g.
ADIS16364
Preliminary Technical Data
OUTLINE DIMENSIONS
31.900
31.700
31.500
23.454
23.200
22.946
9.464
9.210
8.956
(2×)
2.382
BSC
17.41
17.21
17.01
(2×)
1.588
BSC
TOP VIEW
22.964
22.710
22.456
1.588
BSC
10.60
BSC
10.50
BSC
21.410
21.210
21.010
BOTTOM VIEW
5.20
5.00
4.80
(2×)
14.950
14.550
14.150
PIN 24
4.20
4.00
3.80
(2×)
0.05
BSC
PIN 1
7.18
BSC
1.00
BSC
2.00 BSC
12.10
BSC
FRONT VIEW
23.504
23.250
22.996
2.660
2.500
2.340
SIDE VIEW
4.330
BSC
DETAIL A
DETAIL A
1.00
BSC (22×)
1.65 BSC
14.00 BSC
011108-C
0.305
BSC (24×)
4.162 BSC
Figure 16. 24-Lead Module with Connector Interface
(ML-24-2)
Dimensions shown in millimeters
ORDERING GUIDE
Model
ADIS16364BMLZ1
ADIS16364/PCBZ1
1
Temperature Range
−40°C to +105°C
Package Description
24-Lead Module with Connector Interface
Interface Board
Z = RoHS Compliant Part.
©2008 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
PR07906-0-11/08(PrA)
Rev. PrA | Page 16 of 16
Package Option
ML-24-2