Dallas DS1339C-2 I2c serial real-time clock Datasheet

DS1339
I C Serial Real-Time Clock
2
www.maxim-ic.com
GENERAL DESCRIPTION
FEATURES
The DS1339 serial real-time clock (RTC) is a lowpower clock/date device with two programmable timeof-day alarms and a programmable square-wave
output. Address and data are transferred serially
2
through an I C* bus. The clock/date provides seconds,
minutes, hours, day, date, month, and year
information. The date at the end of the month is
automatically adjusted for months with fewer than 31
days, including corrections for leap year. The clock
operates in either the 24-hour or 12-hour format with
AM/PM indicator. The DS1339 has a built-in powersense circuit that detects power failures and
automatically switches to the backup supply,
maintaining time and date operation.
§
§
§
§
§
§
§
§
§
Real-Time Clock (RTC) Counts Seconds, Minutes,
Hours, Day, Date, Month, and Year with LeapYear Compensation Valid Up to 2100
Available in a Surface-Mount Package with an
Integrated Crystal (DS1339C)
2
I C Serial Interface
Two Time-of-Day Alarms
Programmable Square-Wave Output
Oscillator Stop Flag
Automatic Power-Fail Detect and Switch Circuitry
Trickle-Charge Capability
Underwriters Laboratory (UL) Recognized
APPLICATIONS
Pin Configurations appear at end of data sheet.
Handhelds (GPS, POS Terminals)
Consumer Electronics (Set-Top Box, Digital
Recording, Network Appliance)
Office Equipment (Fax/Printers, Copier)
Medical (Glucometer, Medicine Dispenser)
Telecommunications (Routers, Switches, Servers)
Other (Utility Meter, Vending Machine, Thermostat,
Modem)
*I2C is a trademark of Philips Corp. Purchase of I2C components
from Maxim Integrated Products, Inc., or one of its sublicensed
Associated Companies, conveys a license under the Philips I2C
Patent Rights to use these components in an I2C system, provided
that the system conforms to the I2C Standard Specification as
defined by Philips.
ORDERING INFORMATION
PART
DS1339C-2
DS1339C-2+
DS1339C-3
DS1339C-3+
DS1339C-33
DS1339C-33+
DS1339U-2
DS1339U-3
DS1339U-3+
DS1339U-33
DS1339U-33+
TEMP RANGE
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
VOLTAGE (V)
2.0
2.0
3.0
3.0
3.3
3.3
2.0
3.0
3.0
3.3
3.3
PIN-PACKAGE
16 SO (300 mils)
16 SO (300 mils)
16 SO (300 mils)
16 SO (300 mils)
16 SO (300 mils)
16 SO (300 mils)
8 mSOP
8 mSOP
8 mSOP
8 mSOP
8 mSOP
TOP MARK*
DS1339C-2
DS1339C-2
DS1339C-3
DS1339C-3
DS1339C-33
DS1339C-33
1339 ##-2
1339 ##-3
1339 ##-3
1339 ##-33
1339 ##-33
+ Denotes a lead-free/RoHS-compliant device.
## = second line, revision code
2 = 2.0V (VCC ±10%)
3 = 3.0V (VCC ±10%)
33 = 3.3V (VCC ±10%)
* A “+” on the top mark indicates a lead-free device.
1 of 18
REV: 071205
2
DS1339 I C Serial Real-Time Clock
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin Relative to Ground………………………………………………………………-0.3V to +6.0V
Operating Temperature Range…(Noncondensing)….…………………………………………………….-40°C to +85°C
Storage Temperature Range………………………………………………………………………………..-55°C to +125°C
Soldering Temperature Range………….See precautions in the Handling, PC Board Layout, and Assembly section.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is
not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED DC OPERATING CONDITIONS
(TA = -40°C to +85°C) (Note 1)
PARAMETER
Supply Voltage
Backup Supply Voltage
SYMBOL
VCC
CONDITIONS
MIN
TYP
MAX
DS1339-2
1.8
2.0
2.2
DS1339-3
2.7
3.0
3.3
DS1339-33
2.97
3.3
3.63
1.3
3.0
3.7
V
5.5
V
VBACKUP
UNITS
V
Pullup Resistor Voltage (SQW/INT,
SDA, SCL), VCC = 0V
VPU
Logic 1
VIH
0.7 x
VCC
VCC +
0.5
V
Logic 0
VIL
-0.5
+0.3 x
VCC
V
Power-Fail Voltage
VPF
DS1339-2
1.58
1.70
1.80
DS1339-3
2.45
2.59
2.70
DS1339-33
2.70
2.85
2.97
MIN
TYP
MAX
UNITS
V
DC ELECTRICAL CHARACTERISTICS
(VCC = MIN to MAX, TA = -40°C to +85°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
Input Leakage
ILI
(Note 2)
1
mA
I/O Leakage
ILO
(Note 3)
1
mA
Logic 0 Out
VOL = 0.4V; VCC > VCC MIN (-3, -33);
VCC ≥ 2.0V (-2)
IOL
(Note 3)
3
mA
Logic 0 Out
VOL = 0.2 (VCC);
1.8V < VCC < 2.0V (DS1339-2)
IOL
(Note 3)
3
mA
Logic 0 Out
VOL = 0.2 (VCC);
1.3V < VCC < 1.8V (DS1339-2)
IOL
(Note 3)
250
mA
VCC Active Current
ICCA
(Note 4)
450
mA
VCC Standby Current
ICCS
(Note 5)
150
mA
2 of 18
80
2
DS1339 I C Serial Real-Time Clock
DC ELECTRICAL CHARACTERISTICS (continued)
(VCC = MIN to MAX, TA = -40°C to +85°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Trickle-Charger Resistor Register
10h = A5h, VCC = Typ, VBACKUP = 0V
R1
250
W
Trickle-Charger Resistor Register
10h = A6h, VCC = Typ, VBACKUP = 0V
R2
2000
W
Trickle-Charger Resistor Register
10h = A7h, VCC = Typ, VBACKUP = 0V
R3
4000
W
IBKLKG
25
100
nA
TYP
MAX
UNITS
VBACKUP Leakage Current
DC ELECTRICAL CHARACTERISTICS
(VCC = 0V, TA = -40°C to +85°C.) (Note 1)
PARAMETER
SYMBOL
VBACKUP Current EOSC = 0, SQW Off
IBKOSC
(Note 6)
400
700
nA
VBACKUP Current EOSC = 0, SQW On
IBKSQW
(Note 6)
600
1000
nA
IBKDR
(Note 6)
10
100
nA
VBACKUP Current EOSC = 1
CONDITIONS
3 of 18
MIN
2
DS1339 I C Serial Real-Time Clock
AC ELECTRICAL CHARACTERISTICS
(VCC = MIN to MAX, TA = -40°C to +85°C.) (Note 12)
PARAMETER
SYMBOL
SCL Clock Frequency
fSCL
Bus Free Time Between a STOP
and START Condition
tBUF
Hold Time (Repeated) START
Condition (Note 7)
tHD:STA
LOW Period of SCL Clock
tLOW
HIGH Period of SCL Clock
tHIGH
Setup Time for a Repeated
START Condition
tSU:STA
Data Hold Time (Notes 8, 9)
tHD:DAT
Data Setup Time (Note 10)
tSU:DAT
Rise Time of Both SDA and SCL
Signals (Note 11)
tR
Fall Time of Both SDA and SCL
Signals (Note 11)
tF
Setup Time for STOP Condition
tSU:STO
CONDITION
Fast mode
MIN
TYP
100
MAX
400
Standard mode
100
Fast mode
1.3
Standard mode
4.7
Fast mode
0.6
Standard mode
4.0
Fast mode
1.3
Standard mode
4.7
Fast mode
0.6
Standard mode
4.0
Fast mode
0.6
Standard mode
4.7
Fast mode
0
Standard mode
0
Fast mode
100
Standard mode
250
ms
ms
ms
ms
0.9
300
Standard mode
20 + 0.1CB
1000
Fast mode
20 + 0.1CB
300
Standard mode
20 + 0.1CB
300
Standard mode
4.0
Capacitive Load for Each Bus
Line (Note 11)
CB
I/O Capacitance (SDA, SCL)
CI/O
(Note 12)
Oscillator Stop Flag (OSF) Delay
tOSF
(Note 13)
4 of 18
ms
ns
20 + 0.1CB
0.6
kHz
ms
Fast mode
Fast mode
UNITS
ns
ns
ms
100
400
pF
10
pF
ms
2
DS1339 I C Serial Real-Time Clock
POWER-UP/DOWN CHARACTERISTICS
(TA = -40 C to +85°C) (Note 1, Figure 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
(Note 14)
TYP
MAX
UNITS
2
ms
Recovery at Power-Up
tREC
VCC Fall Time; VPF(MAX) to VPF(MIN)
tVCCF
300
ms
VCC Rise Time; VPF(MIN) to VPF(MAX)
tVCCR
0
ms
WARNING: Under no circumstances are negative undershoots, of any amplitude, allowed when device is in
battery-backup mode.
Note 1:
Limits at -40°C are guaranteed by design and are not production tested.
Note 2:
SCL only.
Note 3:
SDA and SQW/INT.
Note 4:
ICCA—SCL at fSC max, VIL = 0.0V, VIH = VCC, trickle charger disabled.
Note 5:
Specified with the I2C bus inactive, VIL = 0.0V, VIH = VCC, trickle charger disabled.
Note 6:
Using recommended crystal on X1 and X2.
Note 7:
After this period, the first clock pulse is generated.
Note 8:
A device must internally provide a hold time of at least 300ns for the SDA signal (referred to the VIHMIN of the SCL signal) to bridge
the undefined region of the falling edge of SCL.
Note 9:
The maximum tHD:DAT need only be met if the device does not stretch the LOW period (tLOW) of the SCL signal.
Note 10:
A fast-mode device can be used in a standard-mode system, but the requirement tSU:DAT ³ to 250ns must then be met. This is
automatically the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW
period of the SCL signal, it must output the next data bit to the SDA line tR(MAX) + tSU:DAT = 1000 + 250 = 1250ns before the SCL line
is released.
Note 11:
CB—total capacitance of one bus line in pF.
Note 12:
Guaranteed by design. Not production tested.
Note 13:
The parameter tOSF is the period of time the oscillator must be stopped for the OSF flag to be set over the voltage range of 0.0V £
VCC £ VCCMAX and 1.3V £ VBACKUP £ 3.7V.
Note 14:
This delay applies only if the oscillator is running. If the oscillator is disabled or stopped, no power-up delay occurs.
Figure 1. Power-Up/Down Timing
VCC
V PF(MAX)
VPF(MIN)
t VCCR
t VCCF
tREC
INPUTS
DON'T CARE
RECOGNIZED
RECOGNIZED
HIGH-Z
OUTPUTS
VALID
VALID
5 of 18
2
DS1339 I C Serial Real-Time Clock
Figure 2. Timing Diagram
Figure 3. Block Diagram
1Hz/4.096kHz/8.192kHz/32.768kHz
X1
X2
"C" VERSION
ONLY
OSCILLATOR AND
DIVIDER
1Hz
VCC
VBACKUP
CONTROL
LOGIC
POWER
CONTROL
Dallas Semiconductor
ALARM,
TRICKLE
CHARGE, AND
CONTROL
REGISTERS
CLOCK AND
CALENDAR
REGISTERS
DS1339
SCL
SDA
MUX/
BUFFER
SERIAL BUS
INTERFACE AND
ADDRESS
REGISTER
USER BUFFER
(7 BYTES)
6 of 18
SQW/INT
2
DS1339 I C Serial Real-Time Clock
PIN DESCRIPTION
PIN
SO
mSOP
NAME
FUNCTION
Connections for Standard 32.768kHz Quartz Crystal. The internal oscillator
circuitry is designed for operation with a crystal having a specified load
capacitance (CL) of 6pF. An external 32.768kHz oscillator can also drive the
DS1339. In this configuration, the X1 pin is connected to the external oscillator
signal and the X2 pin is floated.
1
—
X1
2
—
X2
3
14
VBACKUP
4
15
GND
5
16
SDA
6
1
SCL
7
2
SQW/INT
8
3
VCC
Serial Data Input/Output. SDA is the input/output pin for the I C serial interface.
The SDA pin is an open-drain output and requires an external pullup resistor.
Serial Clock Input. SCL is used to synchronize data movement on the serial
interface.
Square-Wave/Interrupt Output. Programmable square-wave or interrupt output
signal. The SQW/INT pin is an open-drain output and requires an external pullup
resistor.
Power Supply. DC power is provided to the device on these pins.
—
4–13
N.C.
No Connection. These pins are unused and must be connected to ground.
For more information about crystal selection and crystal layout considerations,
refer to Application Note 58: Crystal Considerations with Dallas Real-Time
Clocks.
Secondary Power Supply. Supply voltage must be held between 1.3V and 3.7V
for proper operation. This pin can be connected to a primary cell, such as a
lithium button cell. Additionally, this pin can be connected to a rechargeable cell
or a super cap when used in conjunction with the trickle-charge feature. Diodes
should not be placed in series between the battery and the VBACKUP input, or
improper operation will result. UL recognized to ensure against reverse charging
current when used with a lithium battery If a back up supply is not required,
VBACKUP must be grounded.
Ground. DC power is provided to the device on these pins.
2
TYPICAL OPERATING CIRCUIT
VCC
VCC
CRYSTAL
VCC
RPU
RPU
1
6
X1
SCL
CPU
2
X2
8
VCC
SQW /INT
7
i
DS1339
5
SDA
V BACKUP
GND
3
4
7 of 18
2
DS1339 I C Serial Real-Time Clock
DETAILED DESCRIPTION
The DS1339 serial real-time clock (RTC) is a low-power clock/date device with two programmable time-of-day
2
alarms and a programmable square-wave output. Address and data are transferred serially through an I C bus.
The clock/date provides seconds, minutes, hours, day, date, month, and year information. The date at the end of
the month is automatically adjusted for months with fewer than 31 days, including corrections for leap year. The
clock operates in either the 24-hour or 12-hour format with AM/PM indicator. The DS1339 has a built-in powersense circuit that detects power failures and automatically switches to the backup supply, maintaining time and
date operation.
OPERATION
The DS1339 operates as a slave device on the serial bus. Access is obtained by implementing a START condition
and providing a device identification code followed by data. Subsequent registers can be accessed sequentially
until a STOP condition is executed. The device is fully accessible and data can be written and read when VCC is
greater than VPF. However, when VCC falls below VPF, the internal clock registers are blocked from any access. If
VPF is less than VBACKUP, the device power is switched from VCC to VBACKUP when VCC drops below VPF. If VPF is
greater than VBACKUP, the device power is switched from VCC to VBACKUP when VCC drops below VBACKUP. The
registers are maintained from the VBACKUP source until VCC is returned to nominal levels. The block diagram in
Figure 3 shows the main elements of the serial real-time clock.
OSCILLATOR CIRCUIT
The DS1339 uses an external 32.768kHz crystal. The oscillator circuit does not require any external resistors or
capacitors to operate. Table 1 specifies several crystal parameters for the external crystal. Figure 4 shows a
functional schematic of the oscillator circuit. The startup time is usually less than 1 second when using a crystal
with the specified characteristics.
8 of 18
2
DS1339 I C Serial Real-Time Clock
Table 1. Crystal Specifications*
PARAMETER
SYMBOL
Nominal Frequency
MIN
fO
TYP
MAX
32.768
Series Resistance
ESR
Load Capacitance
CL
kHz
45
6
UNITS
kW
pF
*The crystal, traces, and crystal input pins should be isolated from RF generating signals. Refer to
Application Note 58: Crystal Considerations for Dallas Real-Time Clocks for additional specifications.
Figure 4. Oscillator Circuit Showing Internal Bias Network
RTC
COUNTDOWN
CHAIN
CL1
CL2
RTC
REGISTERS
X2
X1
CRYSTAL
CLOCK ACCURACY
The accuracy of the clock is dependent upon the accuracy of the crystal and the accuracy of the match between
the capacitive load of the oscillator circuit and the capacitive load for which the crystal was trimmed. Additional
error is added by crystal frequency drift caused by temperature shifts. External circuit noise coupled into the
oscillator circuit may result in the clock running fast. Figure 5 shows a typical PC board layout for isolating the
crystal and oscillator from noise. Refer to Application Note 58: Crystal Considerations with Dallas Real-Time
Clocks for detailed information
DS1339C ONLY
The DS1339C integrates a standard 32,768Hz crystal in the package. Typical accuracy at nominal VCC and +25°C
is approximately 10ppm. Refer to Application Note 58 for information about crystal accuracy vs. temperature.
Figure 5. Typical PC Board Layout for Crystal
LOCAL GROUND PLANE (LAYER 2)
X1
CRYSTAL
X2
NOTE: AVOID ROUTING SIGNALS IN
THE CROSSHATCHED AREA (UPPER
LEFT-HAND QUADRANT) OF THE
PACKAGE UNLESS THERE IS A
GROUND PLANE BETWEEN THE
SIGNAL LINE AND THE PACKAGE.
GND
9 of 18
2
DS1339 I C Serial Real-Time Clock
ADDRESS MAP
Figure 6 shows the address map for the DS1339 registers. During a multibyte access, when the address pointer
2
reaches the end of the register space (10h), it wraps around to location 00h. On an I C START, STOP, or address
pointer incrementing to location 00h, the current time is transferred to a second set of registers. The time
information is read from these secondary registers, while the clock may continue to run. This eliminates the need
to re-read the registers in case of an update of the main registers during a read.
Figure 6. Timekeeper Registers
ADDRESS
BIT 7
BIT 6
00H
0
10 Seconds
01H
0
10 Minutes
02H
0
12/24
03H
04H
0
0
0
0
0
05H
Century
0
0
06H
BIT 5
AM/PM
10 Hour
BIT 4
BIT 3
BIT 2
FUNCTION
RANGE
Seconds
Seconds
00–59
Minutes
Minutes
00–59
Hour
Hours
10 Hour
0
BIT 1
0
Day
10 Date
10
Month
Month
Year
07H
A1M1
10 Seconds
Seconds
08H
A1M2
10 Minutes
Minutes
09H
A1M3
0AH
A1M4
0BH
A2M2
0CH
A2M3
AM/PM
10 Hour
DY/DT
10 Hour
10 Date
AM/PM
10 Hour
Alarm 1
Hours
Hour
Alarm 1
Day,
Alarm 1
Date
Alarm 2
Minutes
Day, Date
10 Minutes
12/24
Day
Date
Month/
Century
Year
Alarm 1
Seconds
Alarm 1
Minutes
Date
10 Year
12/24
BIT 0
Minutes
00–59
00–59
1–12 +
AM/PM
00–23
1-7, 1-31
00–59
Hour
Alarm 2
Hours
1–12 +
AM/PM
00–23
Day, Date
Alarm 2
Day,
Alarm 2
Date
1–7, 1–31
10 Hour
10 Date
1–12
+AM/PM
00–23
1–7
01–31
01–12 +
Century
00–99
0DH
A2M4
DY/DT
0EH
EOSC
0
0
RS2
RS1
INTCN
A2IE
A1IE
Control
0FH
OSF
0
0
0
0
0
A2F
A1F
10H
TCS3
TCS2
TCS1
TCS0
DS1
DS0
ROUT1
ROUT0
Status
Trickle
Charger
Note: Unless otherwise specified, the state of the registers are not defined when power is first applied or when VCC and VBACKUP falls below the
VBACKUP(MIN).
10 of 18
2
DS1339 I C Serial Real-Time Clock
TIME AND DATE OPERATION
The time and date information is obtained by reading the appropriate register bytes. Figure 6 shows the RTC
registers. The time and date are set or initialized by writing the appropriate register bytes. The contents of the time
and date registers are in the BCD format. The DS1339 can be run in either 12-hour or 24-hour mode. Bit 6 of the
hours register is defined as the 12- or 24-hour mode-select bit. When high, the 12-hour mode is selected. In the
12-hour mode, bit 5 is the AM/PM bit with logic high being PM. In the 24-hour mode, bit 5 is the second 10-hour bit
(20 to 23 hours). All hours values, including the alarms, must be re-entered whenever the 12/24-hour mode bit is
changed. The century bit (bit 7 of the month register) is toggled when the years register overflows from 99 to 00.
The day-of-week register increments at midnight. Values that correspond to the day of week are user-defined, but
must be sequential (i.e., if 1 equals Sunday, then 2 equals Monday and so on). Illogical time and date entries result
in undefined operation.
When reading or writing the time and date registers, secondary (user) buffers are used to prevent errors when the
internal registers update. When reading the time and date registers, the user buffers are synchronized to the
internal registers on any start or stop, and when the address pointer rolls over to zero. The countdown chain is
reset whenever the seconds register is written. Write transfers occurs on the acknowledge pulse from the device.
To avoid rollover issues, once the countdown chain is reset, the remaining time and date registers must be written
within one second. If enabled, the 1Hz square-wave output transitions high 500ms after the seconds data transfer,
provided the oscillator is already running.
ALARMS
The DS1339 contains two time of day/date alarms. Alarm 1 can be set by writing to registers 07h to 0Ah. Alarm 2
can be set by writing to registers 0Bh to 0Dh. The alarms can be programmed (by the Alarm Enable and INTCN
bits of the Control Register) to activate the SQW/INT output on an alarm match condition. Bit 7 of each of the time
of day/date alarm registers are mask bits (Table 2). When all the mask bits for each alarm are logic 0, an alarm
only occurs when the values in the timekeeping registers 00h to 06h match the values stored in the time of
day/date alarm registers. The alarms can also be programmed to repeat every second, minute, hour, day, or date.
Table 2 shows the possible settings. Configurations not listed in the table result in illogical operation.
The DY/DT bits (bit 6 of the alarm day/date registers) control whether the alarm value stored in bits 0 to 5 of that
register reflects the day of the week or the date of the month. If DY/DT is written to a logic 0, the alarm is the result
of a match with date of the month. If DY/DT is written to a logic 1, the alarm is the result of a match with day of the
week.
The device checks for an alarm match once per second. When the RTC register values match alarm register
settings, the corresponding Alarm Flag ‘A1F’ or ‘A2F’ bit is set to logic 1. If the corresponding Alarm Interrupt
Enable ‘A1IE’ or ‘A2IE’ is also set to logic 1 and the INTCN bit is set to logic 1, the alarm condition activates the
SQW/INT) signal. If the BBSQI bit is set to 1, the INT output activates while the part is being powered by VBACKUP.
The alarm output remains active until the alarm flag is cleared by the user.
11 of 18
2
DS1339 I C Serial Real-Time Clock
Table 2. Alarm Mask Bits
DY/DT
X
X
X
X
ALARM 1 REGISTER MASK BITS
(Bit 7)
A1M4
A1M3
A1M2
A1M1
1
1
1
1
1
1
1
0
1
1
0
0
1
0
0
0
0
0
0
0
0
1
0
0
0
0
ALARM 2 REGISTER MASK BITS
(Bit 7)
A2M4
A2M3
A2M2
1
1
1
1
1
0
1
0
0
0
0
0
0
0
0
DY/DT
X
X
X
0
1
ALARM RATE
Alarm once per second
Alarm when seconds match
Alarm when minutes and seconds match
Alarm when hours, minutes, and seconds match
Alarm when date, hours, minutes, and seconds
match
Alarm when day, hours, minutes, and seconds match
ALARM RATE
Alarm once per minute (00 sec. of every min.)
Alarm when minutes match
Alarm when hours and minutes match
Alarm when date, hours, and minutes match
Alarm when day, hours, and minutes match
SPECIAL-PURPOSE REGISTERS
The DS1339 has two additional registers (control and status) that control the RTC, alarms, and square-wave
output.
CONTROL REGISTER (0Eh)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
EOSC
0
BBSQI
RS2
RS1
INTCN
A2IE
A1IE
Bit 7: Enable Oscillator (EOSC). This bit when set to logic 0 starts the oscillator. When this bit is set to a logic 1,
the oscillator is stopped. This bit is enabled (logic 0) when power is first applied.
Bit 5: Battery-Backed Square-Wave and Interrupt Enable (BBSQI). This bit when set to a logic 1 enables the
square wave or interrupt output when VCC is absent and the DS1339 is being powered by the VBACKUP pin. When
BBSQI is a logic 0, the SQW/INT pin goes high impedance when VCC falls below the power-fail trip point. This bit is
disabled (logic 0) when power is first applied.
Bits 4 and 3: Rate Select (RS2 and RS1). These bits control the frequency of the square-wave output when the
square wave has been enabled. The table below shows the square-wave frequencies that can be selected with the
RS bits. These bits are both set to logic 1 (32kHz) when power is first applied.
Square-Wave Output Frequency
RS2
RS1
0
0
1
1
0
1
0
1
SQUARE-WAVE
OUTPUT
FREQUENCY
1Hz
4.096kHz
8.192kHz
32.768kHz
12 of 18
2
DS1339 I C Serial Real-Time Clock
Bit 2: Interrupt Control (INTCN). This bit controls the relationship between the two alarms and the interrupt output
pins. When the INTCN bit is set to logic 1, a match between the timekeeping registers and the alarm 1 or alarm 2
registers activate the SQW/INT pin (provided that the alarm is enabled). When the INTCN bit is set to logic 0, a
square wave is output on the SQW/INT pin. This bit is set to logic 0 when power is first applied.
Bit 1: Alarm 2 Interrupt Enable (A2IE). When set to a logic 1, this bit permits the Alarm 2 Flag (A2F) bit in the
status register to assert SQW/INT (when INTCN = 1). When the A2IE bit is set to logic 0 or INTCN is set to logic 0,
the A2F bit does not initiate an interrupt signal. The A2IE bit is disabled (logic 0) when power is first applied.
Bit 0: Alarm 1 Interrupt Enable (A1IE). When set to logic 1, this bit permits the Alarm 1 Flag (A1F) bit in the
status register to assert SQW/INT (when INTCN = 1). When the A1IE bit is set to logic 0 or INTCN is set to logic 0,
the A1F bit does not initiate an interrupt signal. The A1IE bit is disabled (logic 0) when power is first applied.
STATUS REGISTER (0Fh)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
OSF
0
0
0
0
0
A2F
A1F
Bit 7: Oscillator Stop Flag (OSF). A logic 1 in this bit indicates that the oscillator either is stopped or was stopped
for some period of time and may be used to judge the validity of the clock and date data. This bit is edge triggered
and is set to logic 1 when the oscillator stops. The following are examples of conditions that can cause the OSF bit
to be set:
1) The first time power is applied.
2) The voltage on both VCC and VBACKUP are insufficient to support oscillation.
3) The EOSC bit is turned off.
4) External influences on the crystal (e.g., noise, leakage, etc.).
This bit remains at logic 1 until written to logic 0. This bit can only be written to a logic 0.
Bit 1: Alarm 2 Flag (A2F). A logic 1 in the Alarm 2 Flag bit indicates that the time matched the alarm 2 registers. If
the A2IE bit is a logic 1 and the INTCN bit is set to a logic 1, the SQW/INT pin is also asserted. A2F is cleared
when written to logic 0. This bit can only be written to logic 0. Attempting to write to logic 1 leaves the value
unchanged.
Bit 0: Alarm 1 Flag (A1F). A logic 1 in the Alarm 1 Flag bit indicates that the time matched the alarm 1 registers. If
the A1IE bit is a logic 1 and the INTCN bit is set to a logic 1, the SQW/INT pin is also asserted. A1F is cleared
when written to logic 0. This bit can only be written to logic 0. Attempting to write to logic 1 leaves the value
unchanged.
13 of 18
2
DS1339 I C Serial Real-Time Clock
TRICKLE CHARGER REGISTER (10h)
The simplified schematic in Figure 7 shows the basic components of the trickle charger. The trickle-charge select
(TCS) bits (bits 4 to 7) control the selection of the trickle charger. To prevent accidental enabling, only a pattern on
1010 enables the trickle charger. All other patterns disable the trickle charger. The trickle charger is disabled when
power is first applied. The diode-select (DS) bits (bits 2 and 3) select whether or not a diode is connected between
VCC and VBACKUP. The ROUT bits (bits 0 and 1) select the value of the resistor connected between VCC and VBACKUP.
Table 3 shows the bit values.
Table 3. Trickle Charger Register (10h)
BIT 7
TCS3
X
X
X
1
1
1
1
1
1
0
BIT 6
TCS2
X
X
X
0
0
0
0
0
0
0
BIT 5
TCS1
X
X
X
1
1
1
1
1
1
0
BIT 4
TCS0
X
X
X
0
0
0
0
0
0
0
BIT 3
DS1
0
1
X
0
1
0
1
0
1
0
BIT 2
DS0
0
1
X
1
0
1
0
1
0
0
BIT 1
ROUT1
X
X
0
0
0
1
1
1
1
0
BIT 0
ROUT0
X
X
0
1
1
0
0
1
1
0
FUNCTION
Disabled
Disabled
Disabled
No diode, 250W resistor
One diode, 250W resistor
No diode, 2kW resistor
One diode, 2kW resistor
No diode, 4kW resistor
One diode, 4kW resistor
Initial power-up values
The user determines diode and resistor selection according to the maximum current desired for battery or super
cap charging. The maximum charging current can be calculated as illustrated in the following example. Assume
that a 3.3V system power supply is applied to VCC and a super cap is connected to VBACKUP. Also assume that the
trickle charger has been enabled with a diode and resistor R2 between VCC and VBACKUP. The maximum current IMAX
would therefore be calculated as follows:
IMAX = (3.3V - diode drop) / R2 » (3.3V - 0.7V) / 2kW » 1.3mA
As the super cap or battery charges, the voltage drop between VCC and VBACKUP decreases and therefore the
charge current decreases.
14 of 18
2
DS1339 I C Serial Real-Time Clock
Figure 7. Programmable Trickle Charger
R1
VCC
250W
VBACKUP
R2
2kW
R3
4kW
1 OF 16 SELECT
NOTE: ONLY 1010 ENABLES CHARGER
TCS3
BIT 7
TCS2
BIT 6
TCS1
BIT 5
TCS0
BIT 4
1 OF 2
SELECT
DS1
BIT 3
1 OF 3
SELECT
DS0
BIT 2
ROUT1
BIT 1
ROUT0
BIT 0
TCS0-3 = TRICKLE CHARGER SELECT
= DIODE SELECT
DS0-1
ROUT0-1 = RESISTOR SELECT
TRICKLE CHARGE REGISTER
I2C SERIAL DATA BUS
2
The DS1339 supports the I C bus protocol. A device that sends data onto the bus is defined as a transmitter and a
device receiving data as a receiver. The device that controls the message is called a master. The devices that are
controlled by the master are referred to as slaves. The bus must be controlled by a master device that generates
the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. The DS1339
2
operates as a slave on the I C bus. Within the bus specifications, a standard mode (100kHz cycle rate) and a fast
mode (400kHz cycle rate) are defined. The DS1339 works in both modes. Connections to the bus are made via the
open-drain I/O lines SDA and SCL.
The following bus protocol has been defined (Figure 8):
§
§
Data transfer may be initiated only when the bus is not busy.
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data
line while the clock line is HIGH are interpreted as control signals.
Accordingly, the following bus conditions have been defined:
Bus not busy: Both data and clock lines remain HIGH.
Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is HIGH, defines a
START condition.
Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is HIGH,
defines the STOP condition.
Data valid: The state of the data line represents valid data when, after a START condition, the data line is stable
for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW
period of the clock signal. There is one clock pulse per bit of data.
15 of 18
2
DS1339 I C Serial Real-Time Clock
Each data transfer is initiated with a START condition and terminated with a STOP condition. The number of data
bytes transferred between START and STOP conditions is not limited, and is determined by the master device.
The information is transferred byte-wise and each receiver acknowledges with a ninth bit.
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the reception
of each byte. The master device must generate an extra clock pulse that is associated with this acknowledge bit.
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that
the SDA line is stable LOW during the HIGH period of the acknowledge related clock pulse. Of course, setup and
hold times must be taken into account. A master must signal an end of data to the slave by not generating an
acknowledge bit on the last byte that has been clocked out of the slave. In this case, the slave must leave the data
line HIGH to enable the master to generate the STOP condition.
Figure 8. Data Transfer on I2C Serial Bus
Depending upon the state of the R/W bit, two types of data transfer are possible:
1) Data transfer from a master transmitter to a slave receiver. The first byte transmitted by the master is the
slave address. Next follows a number of data bytes. The slave returns an acknowledge bit after each received
byte. Data is transferred with the most significant bit (MSB) first.
2) Data transfer from a slave transmitter to a master receiver. The first byte (the slave address) is transmitted
by the master. The slave then returns an acknowledge bit. This is followed by the slave transmitting a number
of data bytes. The master returns an acknowledge bit after all received bytes other than the last byte. At the
end of the last received byte, a “not acknowledge” is returned. The master device generates all of the serial
clock pulses and the START and STOP conditions. A transfer is ended with a STOP condition or with a
repeated START condition. Since a repeated START condition is also the beginning of the next serial transfer,
the bus is not released. Data is transferred with the most significant bit (MSB) first.
The DS1339 can operate in the following two modes:
1) Slave Receiver Mode (Write Mode): Serial data and clock are received through SDA and SCL. After each
byte is received an acknowledge bit is transmitted. START and STOP conditions are recognized as the
beginning and end of a serial transfer. Address recognition is performed by hardware after reception of the
slave address and direction bit (Figure 9). The slave address byte is the first byte received after the START
condition is generated by the master. The slave address byte contains the 7-bit DS1339 address, which is
1101000, followed by the direction bit (R/W), which is 0 for a write. After receiving and decoding the slave
address byte the slave outputs an acknowledge on the SDA line. After the DS1339 acknowledges the slave
address + write bit, the master transmits a register address to the DS1339. This sets the register pointer on the
DS1339, with the DS1339 acknowledging the transfer. The master may then transmit zero or more bytes of
16 of 18
2
DS1339 I C Serial Real-Time Clock
data, with the DS1339 acknowledging each byte received. The address pointer increments after each data
byte is transferred. The master generates a STOP condition to terminate the data write.
2) Slave Transmitter Mode (Read Mode): The first byte is received and handled as in the slave receiver mode.
However, in this mode, the direction bit indicates that the transfer direction is reversed. Serial data is
transmitted on SDA by the DS1339 while the serial clock is input on SCL. START and STOP conditions are
recognized as the beginning and end of a serial transfer (Figure 10). The slave address byte is the first byte
received after the START condition is generated by the master. The slave address byte contains the 7-bit
DS1339 address, which is 1101000, followed by the direction bit (R/W), which is 1 for a read. After receiving
and decoding the slave address byte the slave outputs an acknowledge on the SDA line. The DS1339 then
begins to transmit data starting with the register address pointed to by the register pointer. If the register
pointer is not written to before the initiation of a read mode the first address that is read is the last one stored in
the register pointer. The address pointer is incremented after each byte is transferred. The DS1339 must
receive a “not acknowledge” to end a read.
slave address
S 1101000
R/W
Figure 9. Data Write—Slave Receiver Mode
0
register address (n)
A
XXXXXXXX
A
Data (n)
Data (n+1)
A
XXXXXXXX
S - START
XXXXXXXX
Data (n+x)
A
XXXXXXXX
P
DATA TRANSFERRED
A - ACKNOWLEDGE
(X+1 BYTES + ACKNOWLEDGE)
P - STOP
R/W - READ/WRITE OR DIRECTION BIT
slave address
S 1101000
R/W
Figure 10. Data Read—Slave Transmitter Mode
1
Data (n+1)
Data (n)
A
XXXXXXXX
A
Data (n+2)
A
XXXXXXXX
XXXXXXXX
Data (n+x)
A
XXXXXXXX
S - START
DATA TRANSFERRED
A - ACKNOWLEDGE
P - STOP
(X+1 BYTES + ACKNOWLEDGE)
/A - NOT ACKNOWLEDGE
R/W - READ/WRITE OR DIRECTION BIT
17 of 18
/A
2
DS1339 I C Serial Real-Time Clock
HANDLING, PC BOARD LAYOUT, AND ASSEMBLY
The DS1339C package contains a quartz tuning-fork crystal. Pick-and-place equipment may be used, but
precautions should be taken to ensure that excessive shocks are avoided. Ultrasonic cleaning should be avoided
to prevent damage to the crystal.
Avoid running signal traces under the package, unless a ground plane is placed between the package and the
signal line. All N.C. (no connect) pins must be connected to ground.
The SO package may be reflowed as long as the peak temperature does not exceed 240°C. Peak reflow
temperature (≥ 230°C) duration should not exceed 10 seconds, and the total time above 200°C should not exceed
40 seconds (30 seconds nominal). Exposure to reflow is limited to 2 times maximum.
Moisture-sensitive packages are shipped from the factory dry-packed. Handling instructions listed on the package
label must be followed to prevent damage during reflow. Refer to the IPC/JEDEC J-STD-020B standard for
moisture-sensitive device (MSD) classifications.
PIN CONFIGURATIONS
TOP VIEW
TOP VIEW
SCL
X1
X2
SQW/INT
VCC
DS1339
SQW/INT
VBACKUP
SCL
GND
SDA
SDA
mSOP
DS1339C
GND
VCC
VBACKUP
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
SO (300 mils)
CHIP INFORMATION
TRANSISTOR COUNT: 11,325
PROCESS: CMOS
THERMAL INFORMATION
PART
µSOP
SO
THETA-JA
(°C/W)
229
73
THETA-JC
(°C/W)
39
23
CONDITIONS
Typical
PACKAGE INFORMATION
For the latest package outline information, go to www.maxim-ic.com/DallasPackInfo.
18 of 18
Maxim/Dallas Semiconductor cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim/Dallas Semiconductor product.
No circuit patent licenses are implied. Maxim/Dallas Semiconductor reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2005 Maxim Integrated Products · Printed USA
are registered trademarks of Maxim Integrated Products, Inc., and Dallas Semiconductor Corporation.